JZZV1-10 Two-Element Combined Metering Transformer

The JZZV1-10 Two-Element Combined Metering Transformer is an outdoor epoxy resin cast metering unit designed for 10 kV three-phase three-wire AC power systems with a maximum system voltage of 12 kV.

Share to:

Product Overview

The JZZV1-10 Two-Element Combined Metering Transformer is an outdoor epoxy resin cast metering unit designed for 10 kV three-phase three-wire AC power systems with a maximum system voltage of 12 kV.

Based on a two-element metering arrangement, the unit integrates voltage transformer and current transformer functions within a single device. It provides energy metering, voltage monitoring, current signal acquisition, and protection functions for three-phase three-wire systems.

The product is widely used for pole-mounted energy metering on outdoor 10 kV distribution lines and is a key metering device for outdoor medium-voltage power distribution systems.

Product Features

Insulation and Electrical Performance

  • Outdoor epoxy resin cast insulation:
    The complete unit is vacuum-cast using outdoor-grade epoxy resin. The solid insulation contains no internal air gaps and provides excellent dielectric performance.
  • Suitable for 12 kV systems:
    The unit can withstand the operating voltage, power-frequency withstand voltage, and lightning impulse withstand voltage requirements of 10 kV systems with a maximum system voltage of 12 kV.
  • Low partial discharge:
    Partial discharge is limited to no more than 10 pC, helping reduce insulation ageing and improve long-term operating reliability.
  • Oil-free outdoor construction:
    The dry-type unit contains no insulating oil, eliminating the risks of oil leakage, oil contamination, and oil-related fire hazards. It is suitable for outdoor environments exposed to sunlight, rain, humidity, and normal atmospheric pollution.
  • Integrated two-element metering arrangement:
    The unit is designed specifically for three-phase three-wire systems. It integrates two phase-current transformer elements and voltage transformer elements to acquire three-phase voltage and two-phase current signals.
  • Complete metering capability:
    The acquired voltage and current signals can be used for energy metering, power calculation, load monitoring, and electrical parameter acquisition.
  • Wide ratio range:
    A standard voltage ratio of 10/0.1 kV is available. Current ratios from 5/5 A to 2,000/5 A can be configured according to system load requirements.
  • High metering accuracy:
    Current transformer accuracy classes up to 0.2S and voltage transformer accuracy classes up to 0.2 are available. Accuracy classes of 0.5 and 1 can also be supplied according to application requirements.
  • High pollution-flashover resistance:
    The high-voltage side features a multi-shed insulation structure with an extended creepage distance, providing reliable resistance to surface flashover under humid and polluted outdoor conditions.

Structural and Installation Features

  • Fully enclosed outdoor dry-type structure:
    The complete unit is integrally cast with no exposed internal live components.
  • IP65 protection rating:
    The outdoor enclosure provides IP65 protection, helping prevent the ingress of dust, rainwater, and moisture.
  • Compact integrated design:
    Combining the voltage and current transformer functions within one unit reduces the number of separate devices, saves installation space, and simplifies on-site wiring.
  • Alternative to oil-immersed metering units:
    The dry-type construction can replace conventional oil-immersed metering boxes in suitable applications while eliminating oil maintenance and leakage risks.
  • Outdoor high-voltage terminals:
    The high-voltage side uses copper busbar-type terminals for convenient connection to outdoor distribution conductors.
  • Tin-plated terminal surfaces:
    The terminal contact surfaces are tin-plated to improve resistance to oxidation and corrosion in humid outdoor environments.
  • Waterproof secondary terminal box:
    The secondary terminals are housed inside an IP65 waterproof terminal box to protect the low-voltage circuits from rainwater and moisture.
  • Clearly identified terminals:
    High-voltage terminals are clearly marked, while the secondary voltage and current terminals are grouped separately to simplify wiring and reduce the risk of incorrect connections.
  • Flexible installation:
    The unit supports outdoor pole-mounted crossarm installation and indoor switchgear installation.
  • High mechanical stability:
    The mounting structure provides reliable resistance to vibration and wind loads and can withstand normal outdoor wind, rain, and snow when correctly installed.

Operation and Maintenance Features

  • Low-maintenance operation:
    The dry-type, oil-free construction eliminates oil leakage, oil replacement, and oil-related fire hazards.
  • High mechanical strength:
    The outdoor epoxy resin body provides reliable impact resistance, ageing resistance, and corrosion resistance.
  • Wide operating temperature range:
    The unit can operate at ambient temperatures from -40°C to +70°C. The epoxy resin maintains stable insulation and mechanical properties without becoming brittle or deformed.
  • Suitable for outdoor temperature variations:
    The product can withstand significant seasonal and day-to-night temperature changes.
  • High operational reliability:
    The voltage and current transformer elements use high-quality magnetic cores and winding materials, providing low operating losses and limited temperature rise.
  • Stable long-term accuracy:
    The unit is designed to maintain stable metering performance with minimal accuracy drift during long-term operation.
  • Overvoltage withstand capability:
    The product can withstand switching and lightning overvoltages within its specified insulation level.

Technical Specifications

Electrical Parameters

ParameterSpecification
Applicable System Voltage10 kV AC, Um = 12 kV
Rated Frequency50 Hz
Voltage Ratio10/0.1 kV, customizable
Current Ratio5/5 A to 2,000/5 A, customizable
Voltage Transformer Accuracy ClassClass 0.2 / 0.5 / 1
Current Transformer Accuracy ClassClass 0.2S / 0.5S / 0.5
Power-Frequency Withstand Voltage42 kV for 1 minute at the high-voltage terminal, without breakdown
Lightning Impulse Withstand Voltage75 kV peak, without breakdown
Partial Discharge≤10 pC
Insulation Resistance≥1,000 MΩ between high voltage, low voltage, and earth

Structural and Material Parameters

ParameterSpecification
Insulating MediumFully cast outdoor-grade epoxy resin
Protection RatingIP65
Installation TypeOutdoor pole-mounted crossarm installation or indoor switchgear installation
Thermal ClassClass B, 130°C

Environmental Parameters

ParameterSpecification
Installation Altitude≤2,000 m; high-altitude versions available
Operating Temperature-40°C to +70°C
Storage Temperature-40°C to +85°C
Relative Humidity≤95%, non-condensing

Applicable Standards

StandardDescription
GB 1207Voltage Transformers
GB 1208Current Transformers
GB/T 17215Electricity Metering Equipment
DL/T 448Technical Administrative Code for Electric Energy Metering

Applications

Applicable Power System

The JZZV1-10 Combined Metering Transformer is suitable for 10 kV three-phase three-wire AC power systems with a maximum system voltage of 12 kV.

Typical Applications

  • Pole-mounted energy metering on outdoor 10 kV distribution lines
  • Energy metering and load monitoring in indoor medium-voltage switchgear
  • Box-type substations
  • Switching and distribution stations
  • 10 kV distribution systems in industrial and mining enterprises
  • Commercial buildings and industrial parks
  • Energy data acquisition in power automation systems
  • Power monitoring, control, and load management systems

Main Functions

The combined metering transformer converts the system high voltage and primary current into standardized secondary signals:

  • Secondary voltage: 100 V
  • Secondary current: 5 A

These signals can be supplied to:

  • Three-phase three-wire energy meters
  • Metering instruments
  • Load-monitoring equipment
  • Power data acquisition devices
  • Energy management systems
  • Power automation equipment

The unit supports:

  • Energy metering
  • Power calculation
  • Load monitoring
  • Electrical parameter acquisition
  • Energy consumption analysis
  • Power management

It also provides electrical isolation between the primary power system and the secondary metering circuits, helping ensure the safe operation of connected metering and monitoring equipment.

Operating Conditions

Normal Operating Conditions

  • Installation altitude: no more than 2,000 m
  • Ambient temperature: -40°C to +70°C
  • Severe or sudden temperature changes should be avoided
  • Relative humidity: no more than 95%, non-condensing
  • The environment should be free from corrosive gases
  • Flammable or explosive substances are not permitted
  • Severe vibration and mechanical impact should be avoided
  • The outdoor unit can withstand normal sunlight, rain, frost, and wind exposure
  • Outdoor pole-mounted crossarm or indoor switchgear installation
  • Severe corrosion, salt spray, and heavy sand or dust conditions should be avoided unless a customized version is used

Special Operating Conditions

Customized products are required for:

  • Installation altitudes above 2,000 m
  • Ambient temperatures outside the range of -40°C to +70°C
  • Severe pollution or salt-spray environments
  • Chemically corrosive environments
  • Strong wind or severe sand and dust conditions
  • High-intensity ultraviolet exposure
  • Non-standard voltage ratios
  • Non-standard current ratios
  • Special mounting dimensions

Installation and Maintenance

Installation Requirements

  1. Pre-installation inspection:
    Inspect the combined metering transformer and confirm that the epoxy resin body is free from cracks, bubbles, mechanical damage, and other visible defects. Check that all terminal markings are clear and that the supplied accessories are complete. Verify that the model, specifications, voltage ratio, current ratio, and metering accuracy classes match the system design requirements.
  2. Mounting:
    Select a suitable crossarm and mounting bracket according to the installation arrangement. Secure the metering transformer in the specified position and confirm that there is no looseness, displacement, or uneven mechanical loading. The mounting surface should be level. Outdoor pole-mounted installations must meet the applicable wind-load and anti-overturning requirements.
  3. High-voltage-side connection:
    Connect the high-voltage terminals according to the system design. Ensure that all connections are securely tightened and provide reliable electrical contact. Maintain adequate electrical clearance between high-voltage conductors, earthed components, and other live parts. Outdoor connections must be protected against water ingress and corrosion. Conductive joint compound should be applied to the terminal contact surfaces where required to reduce oxidation.
  4. Secondary-side connection:
    Connect the voltage and current secondary terminals to the energy meter according to their markings. The current transformer secondary circuits must never be left open while the primary system is energized. The voltage transformer secondary circuits must never be short-circuited. The current secondary circuits must be reliably earthed at one point in accordance with the system design and applicable electrical safety requirements. Ensure that the waterproof secondary terminal box is correctly closed and sealed after wiring.
  5. Insulation inspection:
    After installation, measure the insulation resistance between:
    • High voltage and low voltage
    • High voltage and earth
    • Low voltage and earth
    Confirm that all secondary circuits are correctly connected and free from unintended open circuits or short circuits. Verify the energy meter connections and phase sequence before energizing the system.

Maintenance Requirements

  • Regularly inspect the epoxy resin body for cracks, mechanical damage, discharge marks, and contamination.
  • Check the high-voltage terminals for looseness, oxidation, corrosion, and abnormal heating.
  • Inspect the waterproofing and corrosion protection of outdoor connections.
  • Confirm that the secondary terminal box remains properly sealed.
  • Regularly inspect high-voltage and low-voltage connections for looseness, overheating, and discoloration.
  • Confirm that the current secondary circuits remain correctly connected and reliably earthed.
  • Periodically verify the metering accuracy and compare the energy meter readings with the specified error limits of the combined metering transformer.
  • Periodically test the insulation resistance and confirm that the insulation performance remains within the specified requirements.
  • Clean dust and contamination from the product surface.
  • Regularly clean the insulating sheds to reduce the risk of pollution flashover.
  • Prevent oil and corrosive substances from contacting the epoxy resin body.
  • If cracking, electrical discharge, overheating, or excessive metering error is detected, immediately de-energize and inspect the equipment. Replace the unit where necessary.

Precautions

  1. The current transformer secondary circuits must never be left open while the primary system is energized. The voltage transformer secondary circuits must never be short-circuited. Either condition may produce hazardous overvoltage or overcurrent and create a serious risk to equipment and personnel.
  2. During maintenance, the current secondary circuits must be securely short-circuited and earthed before disconnection. The voltage secondary circuits must be safely isolated before work begins.
  3. Avoid impact or collision with the epoxy resin body and high-voltage terminals during transportation and installation. Mechanical damage may reduce insulation performance and pollution-flashover resistance.
  4. Use suitable insulated conductors for high-voltage connections. Maintain adequate electrical clearance from earthed components and other live parts to prevent phase-to-phase or phase-to-earth discharge.
  5. Confirm the correct phase sequence during three-phase wiring. Incorrect phase connections may affect metering accuracy.
  6. The equipment must be reliably earthed. The grounding terminal on the base must be securely connected to the grounding busbar.
  7. Outdoor installations must comply with applicable lightning protection and earthing requirements.
  8. Outdoor connections must be properly protected against rainwater ingress and corrosion.
  9. Store the product in a dry, ventilated, and shaded environment. Avoid direct sunlight, high temperatures, moisture, compression, and mechanical impact.
  10. Installation, commissioning, and maintenance must be carried out by qualified electrical personnel in accordance with applicable electrical safety procedures.
  11. The combined metering transformer must pass verification by the relevant local metrology authority before being put into service where such verification is required.

Standard Supply List

No.ItemFunction
1JZZV1-10 Outdoor Two-Element Combined Metering TransformerMain device for voltage and current transformation, electrical isolation, and energy metering
2Mounting Brackets, Bolts, and WashersUsed to secure the metering transformer during installation
3Secondary Terminal Box and Terminal CoverProtect the low-voltage terminals against incorrect connection, short circuits, and water ingress
4Product Instruction ManualProvides installation, operation, maintenance, wiring, and outdoor mounting guidance
5Product Certificate, Factory Test Report, and Metrological Verification CertificateProvide product quality and performance documentation, including voltage-ratio, current-ratio, and accuracy test data

Applicable Standards and Certification

The product complies with the following standards:

  • GB 1207, Voltage Transformers
  • GB 1208, Current Transformers
  • GB/T 17215, Electricity Metering Equipment
  • DL/T 448, Technical Administrative Code for Electric Energy Metering

The product has passed the applicable type tests and metrological verification. Its performance meets the energy-metering requirements of 10 kV three-phase three-wire power systems.

JZZV1-10 Two-Element Combined Metering Transformer