{"id":673,"date":"2026-01-26T06:35:11","date_gmt":"2026-01-26T06:35:11","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=673"},"modified":"2026-09-16T02:07:41","modified_gmt":"2026-09-16T02:07:41","slug":"tg3-35q-260x260x450-bushing","status":"publish","type":"products","link":"https:\/\/yieou.com\/ar\/product\/tg3-35q-260x260x450-bushing\/","title":{"rendered":"TG3-35Q\/260x260x450 \u062c\u0644\u0628\u0629 (\u062c\u0647\u062f \u062a\u062d\u0645\u0644 \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a: 95 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a\/1 \u062f\u0642\u064a\u0642\u0629\u061b \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a: \u22645 \u0628\u064a\u0643\u0648 \u0643\u0648\u0644\u0648\u0645 @ 40.5 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a)"},"content":{"rendered":"<h3 class=\"wp-block-heading\">\u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0646\u062a\u062c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/ar\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">\u062c\u0644\u0628\u0629 \u0627\u0644\u062d\u0627\u0626\u0637 TG3-35Q\/260\u00d7260\u00d7450<\/a> \u0647\u0648 \u0645\u0643\u0648\u0646 \u0639\u0627\u0632\u0644 \u0645\u0646 \u0631\u0627\u062a\u0646\u062c \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a \u0645\u0635\u0645\u0645 \u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a 35 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It allows live conductors, such as busbars and copper bars, to pass safely through walls, partitions, switchgear panels, and other grounded structures. The bushing provides electrical insulation, mechanical support, and a stable passage for conductor connections, helping ensure the safe and reliable operation of high-voltage power systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0645\u0646\u0627\u0633\u0628 \u0644\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0641\u064a \u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629\u060c \u0648\u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629\u060c \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a>\u060c \u0648\u063a\u0631\u0641 \u0627\u0644\u062a\u0648\u0632\u064a\u0639\u060c \u0648\u063a\u064a\u0631\u0647\u0627 \u0645\u0646 \u0627\u0644\u062a\u0631\u0643\u064a\u0628\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u062a\u0648\u0633\u0637.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0645\u0639\u0627\u0645\u0644<\/th><th>\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/th><\/tr><\/thead><tbody><tr><td>\u0645\u0648\u062f\u064a\u0644 \u0627\u0644\u0645\u0646\u062a\u062c<\/td><td>TG3-35Q\/260\u00d7260\u00d7450<\/td><\/tr><tr><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646<\/td><td>40.5 kV, suitable for 35 kV systems<\/td><\/tr><tr><td>\u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0645\u0642\u0646\u0646<\/td><td>15\u201360 Hz<\/td><\/tr><tr><td>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/td><td>630\u20133150 A, customizable upon request<\/td><\/tr><tr><td>\u0627\u0644\u0623\u0628\u0639\u0627\u062f \u0627\u0644\u0643\u0644\u064a\u0629<\/td><td>260 \u00d7 260 \u00d7 450 mm<\/td><\/tr><tr><td>Mounting Flange Size<\/td><td>260 \u00d7 260 mm<\/td><\/tr><tr><td>\u0645\u0627\u062f\u0629<\/td><td>Epoxy resin manufactured by APG process<\/td><\/tr><tr><td>Colour<\/td><td>Red<\/td><\/tr><tr><td>\u062c\u0647\u062f \u062a\u062d\u0645\u0644 \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/td><td>95 kV for 1 minute under dry conditions<\/td><\/tr><tr><td>\u062c\u0647\u062f \u062a\u062d\u0645\u0644 \u0627\u0644\u0646\u0628\u0636\u0627\u062a \u0627\u0644\u0628\u0631\u0642\u064a\u0629<\/td><td>185 kV peak<\/td><\/tr><tr><td>\u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a<\/td><td>\u22645 pC at 1.1 Um<\/td><\/tr><tr><td>\u0645\u0633\u0627\u0641\u0629 \u0627\u0644\u0632\u062d\u0641<\/td><td>Complies with the applicable requirements of GB\/T 311 and related standards<\/td><\/tr><tr><td>Optional Configuration<\/td><td>Integrated internal shielding layer<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0645\u0646\u062a\u062c<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Excellent Electrical Insulation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The wall bushing is manufactured through an integrated epoxy resin Automatic Pressure Gelation process. The dense moulded structure helps minimize internal bubbles, voids, and other insulation defects.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Its high dielectric strength provides reliable resistance to electrical breakdown in 35 kV power systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The external shed structure increases the creepage distance and improves resistance to surface tracking, moisture, contamination, and flashover.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0642\u0648\u0629 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0645\u0648\u062b\u0648\u0642\u0629<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The epoxy resin body provides good resistance to impact, bending, cracking, and mechanical deformation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It can withstand the electrodynamic forces generated by busbars during short-circuit conditions, helping maintain conductor alignment and structural stability during long-term operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The square mounting flange distributes mechanical loads evenly and provides a firm connection to switchgear panels, walls, or equipment partitions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Optimized Electric Field Distribution<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">An internal shielding layer can be integrated according to application requirements. The shielding structure helps distribute the electric field more evenly, reduce local electric field concentration, and suppress partial discharge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The smooth internal and external surfaces contain no sharp edges, helping reduce corona discharge and improve long-term insulation reliability.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0642\u062f\u0631\u0629 \u0639\u0627\u0644\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u0643\u064a\u0641 \u0627\u0644\u0628\u064a\u0626\u064a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The epoxy resin material provides resistance to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>High and low temperatures<\/li>\n\n\n\n<li>Electrical ageing<\/li>\n\n\n\n<li>Moisture<\/li>\n\n\n\n<li>Chemical corrosion<\/li>\n\n\n\n<li>Mould and fungal growth<\/li>\n\n\n\n<li>Insects and other biological influences<\/li>\n\n\n\n<li>Common industrial contaminants<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The product can be used in indoor, outdoor, high-altitude, and industrial power distribution environments, subject to the selected creepage distance and installation configuration.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u062a\u0631\u0643\u064a\u0628 \u0648\u0635\u064a\u0627\u0646\u0629 \u0645\u0631\u064a\u062d\u0629<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The standardized flange dimensions and mounting-hole arrangement allow the bushing to be installed in compatible 35 kV switchgear, including KYN61-40.5 and similar cabinet structures.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Its compact and lightweight design simplifies installation. Under normal operating conditions, routine maintenance is limited mainly to surface cleaning and connection inspection.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The TG3-35Q\/260\u00d7260\u00d7450 Wall Bushing is suitable for three-phase AC power systems with rated voltages from 10 to 35 kV and frequencies from 15 to 60 Hz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u062a\u0634\u0645\u0644 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Busbar passage connections inside high-voltage switchgear<\/li>\n\n\n\n<li>KYN61-40.5 and similar 35 kV switchgear<\/li>\n\n\n\n<li>Busbar connections through substation walls and partitions<\/li>\n\n\n\n<li>Power distribution room wall penetrations<\/li>\n\n\n\n<li>Box-type substations<\/li>\n\n\n\n<li>\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u062d\u0644\u0642\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/li>\n\n\n\n<li>Busbar and conductor insulation support<\/li>\n\n\n\n<li>Industrial high-voltage distribution systems<\/li>\n\n\n\n<li>Mining power distribution systems<\/li>\n\n\n\n<li>Petrochemical electrical installations<\/li>\n\n\n\n<li>Power stations and substations<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The bushing can be used wherever a live conductor must pass through a grounded wall, metal panel, equipment partition, or insulating barrier.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Normal Environmental Conditions<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Condition<\/th><th>Requirement<\/th><\/tr><\/thead><tbody><tr><td>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629<\/td><td>-40\u00b0C to +120\u00b0C<\/td><\/tr><tr><td>Short-Term Temperature Resistance<\/td><td>Up to +155\u00b0C<\/td><\/tr><tr><td>Installation Altitude<\/td><td>\u22643,000 m<\/td><\/tr><tr><td>Daily Average Relative Humidity<\/td><td>\u226495%<\/td><\/tr><tr><td>Monthly Average Relative Humidity<\/td><td>\u226490%<\/td><\/tr><tr><td>Pollution Level<\/td><td>Up to Level IV<\/td><\/tr><tr><td>\u0628\u064a\u0626\u0629 \u0627\u0644\u062a\u062b\u0628\u064a\u062a<\/td><td>Free from severe vibration, impact, explosive substances, and strongly corrosive gases<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">For installations above 3,000 metres, equipment derating, insulation coordination adjustment, or a customized bushing may be required.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For heavily polluted environments, a model with an increased creepage distance should be selected.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u062b\u0628\u064a\u062a<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Installation Direction<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The wall bushing can be installed vertically or horizontally.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The flange surface must fit closely against the switchgear panel, wall, or mounting partition. All fastening points should be tightened evenly to avoid mechanical stress and deformation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Conductor Installation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When inserting a copper bar or busbar through the bushing, maintain an even clearance between the conductor and the inner surface.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The conductor must be correctly centred to prevent localized mechanical stress and uneven electric field distribution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do not force an oversized or misaligned conductor through the bushing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sealing and Protection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Install a suitable sealing gasket between the flange and the mounting surface.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The seal helps prevent dust, moisture, and contaminants from entering the equipment compartment and improves long-term insulation reliability.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0627\u0644\u062e\u0644\u0648\u0635 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">After installation, verify the clearance between live conductors and grounded structures.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The completed assembly must meet the minimum electrical clearance and insulation coordination requirements specified in GB\/T 311 and other applicable standards.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Fastening Requirements<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Use suitable mounting bolts and tighten them according to the equipment assembly specifications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Excessive tightening may damage the epoxy resin flange, while insufficient tightening may result in vibration, loosening, or uneven mechanical loading.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Inspection and Maintenance<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">\u0641\u062d\u0635 \u0645\u0627 \u0642\u0628\u0644 \u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before installation, confirm that:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The model and dimensions match the equipment design<\/li>\n\n\n\n<li>The flange dimensions and mounting holes are compatible<\/li>\n\n\n\n<li>The surface is clean and dry<\/li>\n\n\n\n<li>No cracks, chips, deformation, or impact damage are present<\/li>\n\n\n\n<li>The internal passage is free from foreign objects<\/li>\n\n\n\n<li>Required electrical inspection results are acceptable<\/li>\n\n\n\n<li>The conductor size matches the internal opening<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Do not install a bushing with visible damage or suspected insulation defects.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Routine Inspection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">During scheduled equipment maintenance:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Clean contamination from the insulating surface<\/li>\n\n\n\n<li>Check the flange mounting bolts for looseness<\/li>\n\n\n\n<li>Inspect the surface for cracks or deformation<\/li>\n\n\n\n<li>Check for electrical tracking marks<\/li>\n\n\n\n<li>Check for carbonization or arc damage<\/li>\n\n\n\n<li>Inspect for abnormal partial discharge<\/li>\n\n\n\n<li>Confirm that the conductor remains correctly positioned<\/li>\n\n\n\n<li>Check the condition of the flange sealing gasket<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Use a clean, dry, soft cloth for routine cleaning. Do not use corrosive solvents, metal tools, or abrasive cleaning materials.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Replacement Conditions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Stop operation and inspect or replace the wall bushing immediately if any of the following conditions are found:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Visible cracks<\/li>\n\n\n\n<li>Severe surface damage<\/li>\n\n\n\n<li>Carbonization<\/li>\n\n\n\n<li>Electrical tracking<\/li>\n\n\n\n<li>Arc erosion<\/li>\n\n\n\n<li>Abnormal partial discharge<\/li>\n\n\n\n<li>Mechanical deformation<\/li>\n\n\n\n<li>Loose or damaged conductor connections<\/li>\n\n\n\n<li>Significant deterioration of insulation performance<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u0627\u062d\u062a\u064a\u0627\u0637\u0627\u062a \u0627\u0644\u0633\u0644\u0627\u0645\u0629<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Avoid impact, dropping, compression, and improper stacking during transportation.<\/li>\n\n\n\n<li>Store the product in a dry, ventilated environment free from corrosive gases.<\/li>\n\n\n\n<li>Protect the insulating surface from moisture, oil, dust, and mechanical damage.<\/li>\n\n\n\n<li>Do not drill, cut, grind, or otherwise modify the bushing without technical approval.<\/li>\n\n\n\n<li>Do not install or remove the product while the equipment is energized.<\/li>\n\n\n\n<li>Disconnect and isolate all power sources before installation or maintenance.<\/li>\n\n\n\n<li>Confirm that the circuit is de-energized and properly grounded before work begins.<\/li>\n\n\n\n<li>Installation and maintenance must be carried out by qualified electrical personnel.<\/li>\n\n\n\n<li>Stop operation immediately if partial discharge, tracking marks, cracks, or other insulation abnormalities are detected.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Selection and Ordering Information<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When selecting the TG3-35Q\/260\u00d7260\u00d7450 Wall Bushing, confirm the following information:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>System rated voltage<\/li>\n\n\n\n<li>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/li>\n\n\n\n<li>Conductor or busbar dimensions<\/li>\n\n\n\n<li>Installation direction<\/li>\n\n\n\n<li>Mounting flange dimensions<\/li>\n\n\n\n<li>Available installation space<\/li>\n\n\n\n<li>Required creepage distance<\/li>\n\n\n\n<li>Environmental pollution level<\/li>\n\n\n\n<li>Installation altitude<\/li>\n\n\n\n<li>Need for an internal shielding layer<\/li>\n\n\n\n<li>Indoor or outdoor operating conditions<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Customized rated current, conductor openings, creepage distances, shielding structures, and mounting dimensions are available according to project requirements.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"384\" height=\"384\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-260x260x450-Bushing.png\" alt=\"TG3-35Q-260x260x450-\u062c\u0644\u0628\u0629\" class=\"wp-image-674\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-260x260x450-Bushing.png 384w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-260x260x450-Bushing-300x300.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-260x260x450-Bushing-150x150.png 150w\" sizes=\"(max-width: 384px) 100vw, 384px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The TG3-35Q\/260\u00d7260\u00d7450 Wall Bushing is an epoxy resin insulating component designed for 35 kV high-voltage power systems. It [&hellip;]<\/p>\n","protected":false},"featured_media":674,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[34],"class_list":["post-673","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-insulation-components-series"],"acf":{"products_imagines":[674,675],"short_describe":"<p>The TG3-35Q\/260&times;260&times;450 Wall Bushing is an epoxy resin insulating component designed for 35 kV high-voltage power systems.<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/products\/673","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/media\/675"},{"embeddable":true,"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/media\/674"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/media\/674"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/media?parent=673"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/product_category?post=673"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}