{"id":676,"date":"2026-01-26T06:37:44","date_gmt":"2026-01-26T06:37:44","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=676"},"modified":"2026-09-16T02:09:34","modified_gmt":"2026-09-16T02:09:34","slug":"tg3-35q-260x260x395-3av3-bushing","status":"publish","type":"products","link":"https:\/\/yieou.com\/ar\/product\/tg3-35q-260x260x395-3av3-bushing\/","title":{"rendered":"TG3-35Q\/260x260x395 3AV3 \u0628\u0648\u0634\u064a\u0646\u062c (\u062c\u0647\u062f \u062a\u062d\u0645\u0644 \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a: 95 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a\/1 \u062f\u0642\u064a\u0642\u0629\u061b \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a: \u22645 \u0628\u064a\u0643\u0648 \u0643\u0648\u0644\u0648\u0645 @ 40.5 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a)"},"content":{"rendered":"<h3 class=\"wp-block-heading\">\u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0646\u062a\u062c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/ar\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">\u062c\u0644\u0628\u0629 \u0627\u0644\u062d\u0627\u0626\u0637 TG3-35Q\/260\u00d7260\u00d7395 3AV3<\/a> \u0647\u0648 \u0645\u0643\u0648\u0646 \u0639\u0627\u0632\u0644 \u0645\u0635\u0628\u0648\u0628 \u0645\u0646 \u0631\u0627\u062a\u0646\u062c \u0627\u0644\u0625\u064a\u0628\u0648\u0643\u0633\u064a \u0645\u0635\u0645\u0645 \u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0630\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a 35 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0648 40.5 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u064a\u064f\u0633\u062a\u062e\u062f\u0645 \u0628\u0634\u0643\u0644 \u0623\u0633\u0627\u0633\u064a \u062d\u064a\u062b \u062a\u0645\u0631 \u0627\u0644\u0645\u0648\u0635\u0644\u0627\u062a \u0627\u0644\u062d\u064a\u0629\u060c \u0645\u062b\u0644 \u0642\u0636\u0628\u0627\u0646 \u0627\u0644\u062a\u0648\u0635\u064a\u0644 \u0623\u0648 \u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a\u060c \u0639\u0628\u0631 \u0641\u0648\u0627\u0635\u0644 \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d\u060c \u0623\u0648 \u0627\u0644\u062c\u062f\u0631\u0627\u0646\u060c \u0623\u0648 \u0627\u0644\u0623\u0644\u0648\u0627\u062d \u0627\u0644\u0645\u0639\u062f\u0646\u064a\u0629\u060c \u0623\u0648 \u0627\u0644\u0647\u064a\u0627\u0643\u0644 \u0627\u0644\u0645\u0624\u0631\u0636\u0629 \u0627\u0644\u0623\u062e\u0631\u0649. \u062a\u0648\u0641\u0631 \u0627\u0644\u0628\u0637\u0627\u0646\u0629 \u0639\u0632\u0644\u0627\u064b \u0643\u0647\u0631\u0628\u0627\u0626\u064a\u064b\u0627 \u0645\u0648\u062b\u0648\u0642\u064b\u0627 \u0648\u062f\u0639\u0645\u064b\u0627 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u064b\u0627 \u0648\u062a\u064f\u0633\u062a\u062e\u062f\u0645 \u0639\u0644\u0649 \u0646\u0637\u0627\u0642 \u0648\u0627\u0633\u0639 \u0641\u064a \u0627\u0644\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0633\u062d\u0628 <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a>\u060c \u0644\u0648\u062d\u0627\u062a \u0627\u0644\u0645\u0641\u0627\u062a\u064a\u062d \u0639\u0627\u0644\u064a\u0629 \u0627\u0644\u062c\u0647\u062f \u0645\u0646 \u0637\u0631\u0627\u0632 KYN61\u060c \u0648\u0627\u0644\u0645\u062d\u0637\u0627\u062a \u0627\u0644\u0641\u0631\u0639\u064a\u0629\u060c \u0648\u0645\u0639\u062f\u0627\u062a \u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0637\u0627\u0642\u0629.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Manufactured using an integrated epoxy resin APG process, the product features an optimized multi-shed structure, excellent electrical insulation, high mechanical strength, and reliable environmental adaptability. It is one of the key insulating components used in 35 kV high-voltage equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0645\u0639\u0627\u0645\u0644<\/th><th>\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/th><\/tr><\/thead><tbody><tr><td>\u0645\u0648\u062f\u064a\u0644 \u0627\u0644\u0645\u0646\u062a\u062c<\/td><td>TG3-35Q\/260\u00d7260\u00d7395 3AV3<\/td><\/tr><tr><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646<\/td><td>40.5 kV, suitable for 35 kV systems<\/td><\/tr><tr><td>\u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0645\u0642\u0646\u0646<\/td><td>15\u201360 Hz<\/td><\/tr><tr><td>\u0623\u0628\u0639\u0627\u062f \u0627\u0644\u0634\u0641\u0629<\/td><td>260 \u00d7 260 mm<\/td><\/tr><tr><td>\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u0643\u0644\u064a<\/td><td>395 mm<\/td><\/tr><tr><td>\u0645\u0627\u062f\u0629<\/td><td>Glass-fibre-reinforced epoxy resin<\/td><\/tr><tr><td>Manufacturing Process<\/td><td>APG casting<\/td><\/tr><tr><td>Insulation Type<\/td><td>Indoor type; outdoor versions available upon request<\/td><\/tr><tr><td>\u062c\u0647\u062f \u062a\u062d\u0645\u0644 \u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/td><td>\u226595 kV for 1 minute under dry conditions<\/td><\/tr><tr><td>\u062c\u0647\u062f \u062a\u062d\u0645\u0644 \u0627\u0644\u0646\u0628\u0636\u0627\u062a \u0627\u0644\u0628\u0631\u0642\u064a\u0629<\/td><td>\u2265185 kV peak<\/td><\/tr><tr><td>\u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u062c\u0632\u0626\u064a<\/td><td>\u22645 pC at 1.1 \u00d7 Un<\/td><\/tr><tr><td>\u0627\u0644\u0641\u0626\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629<\/td><td>Class F, long-term operating temperature up to 155\u00b0C<\/td><\/tr><tr><td>\u062a\u0635\u0646\u064a\u0641 \u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0644\u0647\u0628<\/td><td>UL94 V-0<\/td><\/tr><tr><td>\u0645\u0633\u0627\u0641\u0629 \u0627\u0644\u0632\u062d\u0641<\/td><td>\u22651,000 mm, suitable for Pollution Level IV environments<\/td><\/tr><tr><td>\u0646\u0637\u0627\u0642 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/td><td>3,150\u20135,000 A; customizable<\/td><\/tr><tr><td>Seismic Resistance<\/td><td>Suitable for seismic intensity up to Level 8<\/td><\/tr><tr><td>Structural Type<\/td><td>Unshielded 3AV3 design<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0645\u0646\u062a\u062c<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Excellent Electrical Insulation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The bushing is manufactured from an epoxy resin matrix reinforced with alkali-free glass fibre. With a volume resistivity above 10\u00b9\u00b3 \u03a9\u00b7m and low dielectric loss, it provides reliable insulation against high voltages and helps reduce the risk of electrical breakdown and surface tracking.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The integrated APG moulding process produces a dense and uniform structure with fewer internal bubbles and voids, improving long-term dielectric performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Its multi-shed profile increases the creepage distance and improves resistance to pollution flashover, condensation, moisture, and dust accumulation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0642\u0648\u0629 \u0645\u064a\u0643\u0627\u0646\u064a\u0643\u064a\u0629 \u0639\u0627\u0644\u064a\u0629<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The one-piece cast structure provides a flexural strength of at least 300 MPa and reliable resistance to impact, vibration, and installation stress.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It can withstand electrodynamic forces generated by busbars during short-circuit conditions, helping prevent deformation, displacement, and cracking during operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The square flange structure ensures secure installation and good compatibility with high-voltage switchgear frames.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0642\u062f\u0631\u0629 \u0639\u0627\u0644\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u0643\u064a\u0641 \u0627\u0644\u0628\u064a\u0626\u064a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The product provides reliable performance across a wide temperature range and is resistant to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>High and low temperatures<\/li>\n\n\n\n<li>Electrical and thermal ageing<\/li>\n\n\n\n<li>Oil contamination<\/li>\n\n\n\n<li>Acids and alkalis<\/li>\n\n\n\n<li>Organic solvents<\/li>\n\n\n\n<li>Moisture and condensation<\/li>\n\n\n\n<li>Mould and insects<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The hydrophobic surface helps reduce moisture adhesion and lowers insulation risks in humid operating environments.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Safe and Reliable Design<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The low-partial-discharge structure helps maintain uniform electric field distribution and reduces the risk of accelerated insulation ageing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The smooth internal and external surfaces contain no sharp edges, helping prevent electric field concentration and corona discharge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The product is designed to comply with GB\/T 11022, GB\/T 3906, and other applicable standards. CCC-certified configurations can be provided according to product and project requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The 3AV3 series uses an unshielded design, providing straightforward installation and compatibility with mainstream 35 kV withdrawable switchgear configurations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The TG3-35Q\/260\u00d7260\u00d7395 3AV3 Wall Bushing is suitable for three-phase AC power systems with rated voltages of 35 kV or 40.5 kV and frequencies from 15 to 60 Hz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u062a\u0634\u0645\u0644 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Busbar passage insulation in KYN61 high-voltage switchgear<\/li>\n\n\n\n<li>Withdrawable high-voltage switchgear<\/li>\n\n\n\n<li>Switchgear partition and wall penetrations<\/li>\n\n\n\n<li>Busbar connections between transformers and switchgear<\/li>\n\n\n\n<li>Substation power distribution equipment<\/li>\n\n\n\n<li>High-voltage distribution rooms in industrial facilities<\/li>\n\n\n\n<li>Power plants and utility power distribution systems<\/li>\n\n\n\n<li>Busbar and conductor insulation support<\/li>\n\n\n\n<li>35 kV vacuum circuit breakers<\/li>\n\n\n\n<li>Disconnectors and isolating switches<\/li>\n\n\n\n<li>Current transformers and other high-voltage components<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Standard Operating Environment<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Condition<\/th><th>Requirement<\/th><\/tr><\/thead><tbody><tr><td>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629<\/td><td>-40\u00b0C to +40\u00b0C for indoor models<\/td><\/tr><tr><td>Customized Outdoor Temperature<\/td><td>-40\u00b0C to +80\u00b0C<\/td><\/tr><tr><td>Installation Altitude<\/td><td>\u22641,000 m<\/td><\/tr><tr><td>Monthly Average Relative Humidity<\/td><td>\u226490% at 25\u00b0C<\/td><\/tr><tr><td>\u062a\u0643\u062b\u0641<\/td><td>Not permitted under normal operating conditions<\/td><\/tr><tr><td>Frost Formation<\/td><td>Not permitted<\/td><\/tr><tr><td>Seismic Intensity<\/td><td>\u2264Level 8<\/td><\/tr><tr><td>\u0645\u0648\u0642\u0639 \u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/td><td>Indoor; outdoor versions available<\/td><\/tr><tr><td>Corrosive or Flammable Gases<\/td><td>Not permitted<\/td><\/tr><tr><td>Severe Dust or Salt Spray<\/td><td>Special configuration required<\/td><\/tr><tr><td>Frequent Severe Vibration<\/td><td>Not permitted<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">High-Altitude Conditions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For installations above 1,000 metres, the effects of reduced air insulation and heat dissipation should be considered.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As a general selection reference, the rated current may need to be reduced by approximately 10% for each additional 1,000 metres of altitude. Alternatively, a reinforced high-altitude version can be customized.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The final derating factor should be confirmed according to the complete switchgear design and applicable technical requirements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Heavily Polluted Environments<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For areas exposed to severe dust, salt spray, conductive pollution, or high humidity, the following customized options are available:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Extended creepage distance<\/li>\n\n\n\n<li>Additional or enlarged sheds<\/li>\n\n\n\n<li>RTV anti-pollution flashover coating<\/li>\n\n\n\n<li>Enhanced sealing structure<\/li>\n\n\n\n<li>Customized insulation profile<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Low-Temperature Conditions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A cold-resistant epoxy resin formulation can be selected to maintain mechanical strength and insulation performance at temperatures down to -40\u00b0C.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u062a\u062b\u0628\u064a\u062a<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Flange Installation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The flange must fit closely against the switchgear panel, wall, or mounting partition.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">All mounting bolts should be tightened evenly according to the specified torque. Uneven or excessive tightening may produce local stress and damage the epoxy resin structure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Conductor Alignment<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The conductive rod or busbar must be installed coaxially with the inner opening of the bushing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Incorrect alignment may cause mechanical stress, uneven electrical clearances, or electric field distortion.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do not force an oversized or misaligned conductor through the bushing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Surface Cleaning<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before installation, clean the bushing surface thoroughly and remove:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dust<\/li>\n\n\n\n<li>Oil<\/li>\n\n\n\n<li>Moisture<\/li>\n\n\n\n<li>Metal particles<\/li>\n\n\n\n<li>Packaging residue<\/li>\n\n\n\n<li>Other contaminants<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The insulating surface must remain clean and dry to maintain reliable dielectric performance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0627\u0644\u062e\u0644\u0648\u0635 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">After installation, check the clearance between the conductor, bushing, grounded metal parts, and adjacent electrical components.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The completed assembly must meet the insulation coordination and minimum electrical clearance requirements of the 35 kV system.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Inspection and Maintenance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Regularly inspect the bushing for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Surface cracks<\/li>\n\n\n\n<li>Electrical tracking marks<\/li>\n\n\n\n<li>Carbonization<\/li>\n\n\n\n<li>Contamination accumulation<\/li>\n\n\n\n<li>Moisture or condensation<\/li>\n\n\n\n<li>Mechanical deformation<\/li>\n\n\n\n<li>Loose mounting bolts<\/li>\n\n\n\n<li>Abnormal partial discharge<\/li>\n\n\n\n<li>Arc or corona damage<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Clean the surface using a dry, soft, lint-free cloth. Do not use abrasive tools, metal brushes, or corrosive solvents.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An insulation preventive test is recommended every three to five years, depending on the operating conditions and maintenance plan. Typical tests may include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Power-frequency withstand voltage testing<\/li>\n\n\n\n<li>Partial discharge measurement<\/li>\n\n\n\n<li>Insulation resistance testing<\/li>\n\n\n\n<li>Visual inspection of the insulating surface<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Do not hang heavy objects from the bushing or apply additional mechanical loads that are not included in the equipment design.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Stop operation and replace the bushing immediately if severe cracking, electrical tracking, carbonization, deformation, or abnormal partial discharge is detected.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0648\u0635\u0641 \u0627\u0644\u0646\u0645\u0648\u0630\u062c<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0631\u0645\u0632<\/th><th>\u0648\u0635\u0641<\/th><\/tr><\/thead><tbody><tr><td>TG3<\/td><td>Epoxy resin wall bushing series<\/td><\/tr><tr><td>35Q<\/td><td>Rated for 35 kV systems; Q indicates indoor configuration<\/td><\/tr><tr><td>260\u00d7260<\/td><td>Flange mounting dimensions in millimetres<\/td><\/tr><tr><td>395<\/td><td>Overall height in millimetres<\/td><\/tr><tr><td>3AV3<\/td><td>Unshielded structural configuration for 35 kV withdrawable switchgear<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Selection Recommendations<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For rated currents above 5,000 A, a customized version with a larger internal diameter, optimized conductor structure, or integrated shielding can be supplied.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Outdoor installation requires an outdoor-type version, normally identified by the suffix <strong>\u0648<\/strong>, together with a suitable weather-resistant shed and rain-protection structure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For Pollution Level IV or more demanding environments, a model with an extended creepage distance is recommended, such as the <strong>TG3-35Q\/260\u00d7260\u00d7450<\/strong> configuration.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"387\" height=\"387\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-260x260x395-3AV3-Bushing.png\" alt=\"TG3-35Q-260x260x395-3AV3-\u0628\u0648\u0634\u0646\u062c\" class=\"wp-image-677\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-260x260x395-3AV3-Bushing.png 387w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-260x260x395-3AV3-Bushing-300x300.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-260x260x395-3AV3-Bushing-150x150.png 150w\" sizes=\"(max-width: 387px) 100vw, 387px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The TG3-35Q\/260\u00d7260\u00d7395 3AV3 Wall Bushing is an epoxy resin cast insulating component designed for 35 kV and 40.5 [&hellip;]<\/p>\n","protected":false},"featured_media":677,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[34],"class_list":["post-676","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-insulation-components-series"],"acf":{"products_imagines":[677,678],"short_describe":"<p>The TG3-35Q\/260&times;260&times;395 3AV3 Wall Bushing is an epoxy resin cast insulating component designed for 35 kV and 40.5 kV high-voltage power systems.<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/products\/676","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/media\/678"},{"embeddable":true,"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/media\/677"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/media\/677"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/media?parent=676"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/ar\/wp-json\/wp\/v2\/product_category?post=676"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}