{"id":785,"date":"2026-01-26T08:30:45","date_gmt":"2026-01-26T08:30:45","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=785"},"modified":"2026-05-09T00:00:00","modified_gmt":"2026-05-09T00:00:00","slug":"jv2-10-lower-insulating-cover","status":"publish","type":"products","link":"https:\/\/yieou.com\/es\/product\/jv2-10-lower-insulating-cover\/","title":{"rendered":"JV2-10 Lower Insulating Cover"},"content":{"rendered":"2026-01-26 08:13:18&#8242;, &#8221;, 773, &#8216;https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CG5-10Q-100\u00d7140-145-150-170-Indoor-High-Voltage-Voltage-Presence-Indicating-Device-Sensor-Dedicated-for-Earthing-Switches.png&#8217;, 0, &#8216;attachment&#8217;, &#8216;image\/png&#8217;, 0),\n(775, 2, &#8216;2026-01-26 08:13:15&#8217;, &#8216;2026-01-26 08:13:15&#8217;, &#8221;, &#8216;CG5-10Q 100\u00d7140 (145, 150, 170) Indoor High-Voltage Voltage Presence Indicating Device Sensor (Dedicated for Earthing Switches)1&#8217;, &#8221;, &#8216;inherit&#8217;, &#8216;open&#8217;, &#8216;closed&#8217;, &#8221;, &#8216;cg5-10q-100&#215;140-145-150-170-indoor-high-voltage-voltage-presence-indicating-device-sensor-dedicated-for-earthing-switches1&#8217;, &#8221;, &#8221;, &#8216;2026-01-26 08:13:15&#8217;, &#8216;2026-01-26 08:13:15&#8217;, &#8221;, 773, &#8216;https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CG5-10Q-100\u00d7140-145-150-170-Indoor-High-Voltage-Voltage-Presence-Indicating-Device-Sensor-Dedicated-for-Earthing-Switches1.png&#8217;, 0, &#8216;attachment&#8217;, &#8216;image\/png&#8217;, 0),\n(776, 2, &#8216;2026-01-26 08:15:25&#8217;, &#8216;2026-01-26 08:15:25&#8217;, &#8216;\n\n\n<p class=\"wp-block-paragraph\">CG3-10Q\/85\u00d7170 Indoor High-Voltage Live Display Device Sensor (High-Altitude Type)<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Descripci\u00f3n general del producto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The CG3-10Q\/85\u00d7170 Indoor High-Voltage Live Display Device Sensor (including the 160 and 170 High-Altitude types) is a core component designed specifically for 10kV-class indoor high-voltage electrical systems. Manufactured using epoxy resin integral casting, it delivers outstanding insulation performance, mechanical strength, and environmental adaptability. Suitable for special operating conditions including high-altitude environments, it is used in conjunction with high-voltage live display devices to provide real-time monitoring of energized status in high-voltage circuits and to issue safety warnings. It serves as a critical safety component for high-voltage switchgear, ring main units, and similar equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Caracter\u00edsticas del producto<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Aislamiento y Rendimiento El\u00e9ctrico<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Produced via an integral vacuum epoxy casting process with no air gaps or voids, ensuring stable insulation performance capable of withstanding the rated voltage and transient overvoltages of 10kV systems with adequate insulation margin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Stable capacitance characteristics ensure high compatibility with live display devices, enabling accurate detection of energized status in high-voltage circuits with no risk of false or missed indications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Meets high-altitude design requirements with an optimized insulation structure for low-pressure, high-elevation environments, preventing corona discharge, flashover, and other insulation faults.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mechanical and Structural Characteristics<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Integrated shed design increases creepage distance and enhances resistance to pollution-induced flashover and moisture ingress, suitable for complex indoor environments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">High mechanical strength with resistance to impact and vibration; capable of withstanding mechanical stresses during switchgear transportation, installation, and operation without risk of cracking or deformation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Compact structure with easy installation; compatible with standard 10kV indoor high-voltage switchgear mounting dimensions, offering strong interchangeability.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Adaptabilidad ambiental<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Excellent weathering resistance; operates across a wide temperature range of -40\u00b0C to +70\u00b0C with no degradation in insulation or mechanical performance at temperature extremes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Resistant to moisture, mold, and salt fog; capable of long-term stable operation in high-humidity and dusty indoor environments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">High-altitude type products are optimized for elevations of 3,000 m to 5,000 m, meeting insulation and operational requirements under low atmospheric pressure conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Seguridad y Fiabilidad<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fully insulated construction with no exposed live parts, eliminating the risk of electric shock and ensuring safe operation and maintenance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Long service life, maintenance-free, with no long-term aging or performance degradation, ensuring high reliability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Complies with national standards for high-voltage electrical equipment; validated through type testing; safety-compliant.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Par\u00e1metros t\u00e9cnicos<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Alcance de la aplicaci\u00f3n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Applicable voltage level: 10kV (7.2kV to 12kV) indoor high-voltage AC systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Applicable equipment: Indoor high-voltage switchgear (KYN28, XGN, etc.), ring main units, compact substations, high-voltage busbar compartments, and other 10kV indoor high-voltage electrical equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Escenarios aplicables:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conventional indoor high-voltage distribution rooms and substations;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">High-altitude regions (3,000 m to 5,000 m): indoor high-voltage power stations, industrial and mining enterprise distribution systems;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">High-voltage distribution systems operating in harsh indoor environments with high humidity, heavy dust, or extreme temperatures;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Indoor high-voltage distribution equipment at new energy (photovoltaic, wind power) step-up stations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Functional pairing: Used in conjunction with high-voltage live display devices to monitor the energized status of high-voltage circuits, provide interlocking control, prevent misoperation, and ensure safe operation and maintenance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Condiciones de operaci\u00f3n<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Condiciones de Operaci\u00f3n Normal<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude: Standard type \u22642,000 m; High-Altitude type: 3,000 m to 5,000 m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ambient temperature: -40\u00b0C to +70\u00b0C; daily average temperature \u2264+35\u00b0C;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Relative humidity: daily average relative humidity \u226495%; monthly average relative humidity \u226490% (at 25\u00b0C);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Environmental conditions: free from severe pollution, corrosive gases, flammable or explosive media, and violent vibration or shock;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Installation method: vertically mounted inside the switchgear with reliable connection to the high-voltage busbar\/conductor.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Condiciones de Operaci\u00f3n Especiales (Requiere Personalizaci\u00f3n)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude exceeding 5,000 m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura ambiente fuera del rango de -40\u00b0C a +70\u00b0C;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Entornos severamente contaminados, con niebla salina o qu\u00edmicamente corrosivos;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Heavy vibration or high-impact conditions;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Non-vertical installation orientations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Instalaci\u00f3n y Mantenimiento<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Requisitos de instalaci\u00f3n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before installation, inspect the product for cracks, damage, and voids; verify that the insulation surface is undamaged;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mount vertically inside the switchgear; secure the base reliably with bolts to ensure firm installation;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Connect the top terminal reliably to the high-voltage busbar\/conductor; verify that contact resistance meets requirements;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The wiring between the sensor and the live display device must be shielded and insulated to prevent interference;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Despu\u00e9s de la instalaci\u00f3n, realice pruebas de resistencia de aislamiento y pruebas de tensi\u00f3n de resistencia a frecuencia de potencia antes de la puesta en servicio.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Requisitos de mantenimiento<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Periodically inspect the product exterior for cracks, discharge marks, and accumulated contamination;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Periodically perform insulation resistance testing and power-frequency withstand voltage testing to verify insulation integrity;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clean the product surface to remove dust and contamination; keep the insulation surface dry and clean;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If abnormalities such as cracks, damage, or discharge are detected, immediately take the unit out of service and replace it.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Precauciones<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Installation, commissioning, and maintenance must be performed by qualified electrical personnel; operation by unqualified individuals is strictly prohibited;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before installation or maintenance, ensure the high-voltage circuit is completely de-energized and that all safety precautions are in place;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">High-Altitude type products must not be used at elevations outside their design range, as this may cause insulation failure;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Unauthorized disassembly or modification of the product will void the warranty and safety certification;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">During transportation and storage, protect the product from moisture, vibration, and mechanical impact to prevent insulation damage.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Descripci\u00f3n del modelo<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Normas y Certificaciones Aplicables<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Applicable standards: GB\/T 11022 Common Specifications for High-Voltage Switchgear and Controlgear Standards; GB\/T 3906 3.6kV to 40.5kV AC Metal-Enclosed Switchgear and Controlgear; DL\/T 538 High-Voltage Live Display Devices; and others.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The product has passed type testing conducted by the National High-Voltage Electrical Equipment Quality Supervision and Inspection Center and complies with national electrical safety standards.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Servicio postventa<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Per\u00edodo de garant\u00eda del producto: 18 meses a partir de la fecha de env\u00edo, o 12 meses a partir de la fecha de puesta en marcha, lo que ocurra primero;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Free repair or replacement for quality-related failures during the warranty period;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Technical support, installation guidance, and customization services are available.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Notas del documento<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The technical parameters in this manual are based on standard operating conditions. For special operating conditions, customization based on actual requirements is necessary. The product technical agreement and type test report shall serve as the final reference.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ap\u00e9ndice: Dibujo del esquema del producto<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Categor\u00eda de Par\u00e1metro<\/th><th>Art\u00edculo<\/th><th>Especificaci\u00f3n T\u00e9cnica<\/th><\/tr><\/thead><tbody><tr><td>Par\u00e1metros El\u00e9ctricos Nominal<\/td><td>Tensi\u00f3n nominal (Un)<\/td><td>10kV<\/td><\/tr><tr><td>Frecuencia nominal (fn)<\/td><td>50 Hz<\/td><\/tr><tr><td>| Rated Capacitance<\/td><td>10~30pF (customizable to match the paired live display device)<\/td><\/tr><tr><td>| Tensi\u00f3n de Soporte a Frecuencia de Potencia<\/td><td>42kV\/1min (no breakdown, no flashover)<\/td><\/tr><tr><td>| Tensi\u00f3n de resistencia al impulso de rayo<\/td><td>75kV (peak, no breakdown, no flashover)<\/td><\/tr><tr><td>Structural Parameters<\/td><td>Modelo<\/td><td>CG3-10Q\/85\u00d7170 (160 and 170 High-Altitude types)<\/td><\/tr><tr><td>| Body Diameter<\/td><td>85mm<\/td><\/tr><tr><td>| Overall Height<\/td><td>170mm (160 type: 160mm)<\/td><\/tr><tr><td>| Number of Sheds<\/td><td>5 sheds (standard configuration, customizable)<\/td><\/tr><tr><td>| M\u00e9todo de Instalaci\u00f3n<\/td><td>Base bolt-fixed; top terminal connection<\/td><\/tr><tr><td>Par\u00e1metros Ambientales<\/td><td>Altitud aplicable<\/td><td>Standard type: \u22642,000 m; High-Altitude type: 3,000 m to 5,000 m<\/td><\/tr><tr><td>Temperatura ambiente<\/td><td>-40\u00b0C a +70\u00b0C<\/td><\/tr><tr><td>Humedad Relativa<\/td><td>\u226495% (a 25\u00b0C)<\/td><\/tr><tr><td>| Calificaci\u00f3n S\u00edsmica<\/td><td>Octavo grado<\/td><\/tr><tr><td>Materiales y Proceso<\/td><td>Material del cuerpo<\/td><td>Epoxy resin (EPOXY)<\/td><\/tr><tr><td>Color<\/td><td>Red (standard; customizable)<\/td><\/tr><tr><td>| Clasificaci\u00f3n de Protecci\u00f3n<\/td><td>IP65<\/td><\/tr><tr><td>Normas aplicables<\/td><td><\/td><td>GB\/T 11022, GB\/T 3906, DL\/T 538, etc.<\/td><\/tr><tr><td>Modelo<\/td><td>Significado<\/td><\/tr><tr><td>CG3<\/td><td>Indoor high-voltage live display device sensor series<\/td><\/tr><tr><td>10Q<\/td><td>Rated voltage 10kV; indoor type (Q denotes indoor)<\/td><\/tr><tr><td>85\u00d7170<\/td><td>Body diameter 85mm; overall height 170mm<\/td><\/tr><tr><td>160\/170 High-Altitude Type<\/td><td>Overall height 160mm\/170mm; designed for high-altitude environments<\/td><\/tr><\/tbody><\/table><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>2026-01-26 08:13:18&#8242;, &#8221;, 773, &#8216;https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CG5-10Q-100\u00d7140-145-150-170-Indoor-High-Voltage-Voltage-Presence-Indicating-Device-Sensor-Dedicated-for-Earthing-Switches.png&#8217;, 0, &#8216;attachment&#8217;, &#8216;image\/png&#8217;, 0), (775, 2, &#8216;2026-01-26 08:13:15&#8217;, &#8216;2026-01-26 08:13:15&#8217;, &#8221;, &#8216;CG5-10Q 100\u00d7140 (145, 150, [&hellip;]<\/p>\n","protected":false},"featured_media":786,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[15],"class_list":["post-785","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-casing-series"],"acf":{"products_imagines":[786,787],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/es\/wp-json\/wp\/v2\/products\/785","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/es\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/es\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/es\/wp-json\/wp\/v2\/media\/787"},{"embeddable":true,"href":"https:\/\/yieou.com\/es\/wp-json\/wp\/v2\/media\/786"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/es\/wp-json\/wp\/v2\/media\/786"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/es\/wp-json\/wp\/v2\/media?parent=785"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/es\/wp-json\/wp\/v2\/product_category?post=785"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}