{"id":1613,"date":"2026-05-08T00:00:00","date_gmt":"2026-05-08T00:00:00","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1613"},"modified":"2026-09-15T01:55:35","modified_gmt":"2026-09-15T01:55:35","slug":"jdzx10-10-36-10brzl-10-voltage-transformer","status":"publish","type":"products","link":"https:\/\/yieou.com\/fr\/product\/jdzx10-10-36-10brzl-10-voltage-transformer\/","title":{"rendered":"Transformateur de tension JDZ(X)10-10-3,6\/10B(RZL-10)"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Transformateur de tension JDZ(X)10-10-3,6\/10B(RZL-10)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Section I : Pr\u00e9sentation du produit<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/fr\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">Le transformateur de tension JDZ(X)10-10-3,6\/10B(RZL-10)<\/a> est un transformateur de tension enti\u00e8rement ferm\u00e9, de type sec, en r\u00e9sine coul\u00e9e, con\u00e7u sp\u00e9cifiquement pour les syst\u00e8mes d'alimentation CA int\u00e9rieurs de 10 kV (Um=12 kV). Variante am\u00e9lior\u00e9e de la s\u00e9rie JDZ(X)10, il utilise une structure d'isolation int\u00e9grale en r\u00e9sine \u00e9poxy coul\u00e9e sous vide avec un dispositif de protection int\u00e9gr\u00e9 \u00e0 haute performance limitant le courant. Il est principalement utilis\u00e9 pour la mesure de tension, le comptage d'\u00e9nergie, la protection par relais et la surveillance d'isolement dans les r\u00e9seaux int\u00e9rieurs moyenne tension. <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a> (par exemple, s\u00e9rie KYN28), et est largement appliqu\u00e9 dans les syst\u00e8mes de distribution 10 kV, les postes de transformation sur poteau et les postes de coupure en anneau \u2014 adapt\u00e9 aux syst\u00e8mes de distribution n\u00e9cessitant une haute fiabilit\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Section II : Fonctionnalit\u00e9s cl\u00e9s du produit<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Isolation et performance \u00e9lectrique<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Isolation en r\u00e9sine \u00e9poxy coul\u00e9e enti\u00e8rement encapsul\u00e9e : L'ensemble de l'unit\u00e9 est form\u00e9 par coul\u00e9e sous vide avec de la r\u00e9sine \u00e9poxy, ne laissant aucun vide d'air interne. Les performances d'isolation sont excellentes, capables de supporter la tension de fonctionnement du syst\u00e8me de 12 kV ainsi que les tests de tenue en tension \u00e0 fr\u00e9quence industrielle et en tension de choc. La dur\u00e9e de vie de l'isolation est longue, sans risque de fuite ou de contamination par l'huile \u2014 adapt\u00e9e aux environnements de distribution int\u00e9rieurs sans huile.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Protection am\u00e9lior\u00e9e contre les surintensit\u00e9s : Le dispositif int\u00e9gr\u00e9 de protection \u00e0 haute performance contre les surintensit\u00e9s offre une capacit\u00e9 de tenue aux courts-circuits sup\u00e9rieure, emp\u00eachant efficacement les dommages aux \u00e9quipements caus\u00e9s par des courts-circuits ou des surintensit\u00e9s dans le circuit secondaire. Compar\u00e9 aux produits de type standard, il offre une r\u00e9ponse de protection plus rapide et une fiabilit\u00e9 accrue, am\u00e9liorant la stabilit\u00e9 op\u00e9rationnelle globale du syst\u00e8me.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Compatibilit\u00e9 avec de larges rapports de transformation : Prend en charge plusieurs rapports de transformation (par exemple, 10\/0,1 kV, 10\/0,1\/0,1 kV, etc.), capable de fournir simultan\u00e9ment plusieurs sorties secondaires pour la mesure, la protection et la surveillance d'isolement. Les classes de pr\u00e9cision sont personnalisables (0,2\/0,5\/1\/3P\/6P, etc.) pour r\u00e9pondre aux exigences multi-applications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conception \u00e0 faible d\u00e9charge partielle : La technologie de moulage avanc\u00e9e garantit un niveau de d\u00e9charge partielle \u226410pC, emp\u00eachant le vieillissement de l'isolation caus\u00e9 par des d\u00e9charges partielles \u00e0 long terme et am\u00e9liorant la fiabilit\u00e9 op\u00e9rationnelle \u00e0 long terme.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Caract\u00e9ristiques structurelles et d'installation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Construction \u00e9tanche \u00e0 sec : La construction moul\u00e9e int\u00e9grale ne pr\u00e9sente ni noyau de fer ni pi\u00e8ces sous tension expos\u00e9s. Indice de protection IP20, aucun risque d'incendie, structure compacte, faible encombrement, compatible avec les dimensions de montage des appareillages de commutation standard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conception \u00e0 double mod\u00e8le : JDZ10-10 est le type \u00e0 simple enroulement ; JDZX10-10 est le type avec un enroulement de tension r\u00e9siduelle (pour la surveillance de l'isolement). La s\u00e9lection peut \u00eatre faite de mani\u00e8re flexible en fonction des exigences du syst\u00e8me, compatible avec diff\u00e9rents types d'armoires et de sch\u00e9mas de protection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Marquages de borne clairs : Les bornes primaires haute tension sont clairement \u00e9tiquet\u00e9es ; les bornes secondaires sont prot\u00e9g\u00e9es par des couvercles transparents pour un c\u00e2blage pratique, \u00e9vitant les erreurs de c\u00e2blage et les courts-circuits tout en prot\u00e9geant efficacement contre les courts-circuits accidentels du circuit secondaire. La disposition des bornes est conforme aux normes de c\u00e2blage en armoire.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Montage flexible : La base de montage m\u00e9tallique inf\u00e9rieure est dot\u00e9e de trous de fixation, permettant une installation par boulonnage. Convient pour une installation horizontale dans des armoires int\u00e9rieures \u2014 robuste, avec une excellente r\u00e9sistance aux vibrations, facilitant un agencement compact dans l'armoire.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Fonctionnalit\u00e9s op\u00e9rationnelles et de maintenance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fonctionnement sans entretien : Construction s\u00e8che sans huile, sans risque de fuite ni d'incendie. Le corps moul\u00e9 en r\u00e9sine \u00e9poxy poss\u00e8de une r\u00e9sistance m\u00e9canique \u00e9lev\u00e9e, une r\u00e9sistance aux chocs et une r\u00e9sistance au vieillissement \u2014 sans entretien pendant le fonctionnement \u00e0 long terme, r\u00e9duisant les co\u00fbts d'exploitation et de maintenance, sans besoin de remplacement p\u00e9riodique des fusibles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fonctionnement \u00e0 large plage de temp\u00e9rature : Fonctionne dans une plage de temp\u00e9rature ambiante de -30\u00b0C \u00e0 +70\u00b0C. La r\u00e9sine \u00e9poxy conserve ses performances stables \u00e0 haute et basse temp\u00e9rature, sans risque de fragilisation ou de d\u00e9formation, ce qui la rend adapt\u00e9e \u00e0 diverses conditions climatiques r\u00e9gionales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conception haute fiabilit\u00e9 : Les enroulements sont r\u00e9alis\u00e9s en fil de cuivre \u00e9maill\u00e9 ; le noyau de fer est feuillet\u00e9 avec des t\u00f4les d'acier au silicium de haute qualit\u00e9, ce qui permet de faibles pertes de fonctionnement et une g\u00e9n\u00e9ration de chaleur minimale. L'unit\u00e9 r\u00e9siste aux surtensions, y compris les surtensions de commutation du syst\u00e8me et les surtensions impulsionnelles de foudre. Le dispositif de protection \u00e0 limitation de courant fonctionne de mani\u00e8re stable, garantissant une fonctionnalit\u00e9 de protection fiable.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Section III : Param\u00e8tres techniques (Sp\u00e9cifications typiques)<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Cat\u00e9gorie de param\u00e8tre<\/td><td>Article<\/td><td>Sp\u00e9cification technique<\/td><\/tr><tr><td>Param\u00e8tres \u00e9lectriques<\/td><td>Tension du syst\u00e8me<\/td><td>10 kV CA (Um=12 kV)<\/td><\/tr><tr><td><\/td><td>Fr\u00e9quence nominale<\/td><td>50 Hz<\/td><\/tr><tr><td><\/td><td>Tension primaire nominale<\/td><td>10 kV<\/td><\/tr><tr><td><\/td><td>Tension secondaire nominale<\/td><td>100 V (mesure\/protection) ; 100\/\u221a3 V (surveillance d'isolement, type JDZX) (personnalisable)<\/td><\/tr><tr><td><\/td><td>Courant nominal de sortie<\/td><td>3A \/ 6A \/ 10A (protection am\u00e9lior\u00e9e contre les surintensit\u00e9s)<\/td><\/tr><tr><td><\/td><td>Classe de pr\u00e9cision de mesure<\/td><td>0.2 \/ 0.5 \/ 1<\/td><\/tr><tr><td><\/td><td>Classe de pr\u00e9cision de protection<\/td><td>3P \/ 6P<\/td><\/tr><tr><td><\/td><td>Tension d'isolement \u00e0 fr\u00e9quence industrielle (borne haute tension)<\/td><td>42 kV \/ 1 min, sans claquage<\/td><\/tr><tr><td><\/td><td>Tension de tenue aux impulsions (cr\u00eate)<\/td><td>75 kV, pas de claquage<\/td><\/tr><tr><td><\/td><td>| Niveau de d\u00e9charge partielle<\/td><td>\u226410pC<\/td><\/tr><tr><td><\/td><td>| R\u00e9sistance d'isolement (HT vers BT et terre)<\/td><td>\u22651000M\u03a9<\/td><\/tr><tr><td>Param\u00e8tres structurels et mat\u00e9riels<\/td><td>Milieu isolant<\/td><td>Coul\u00e9e compl\u00e8te en r\u00e9sine \u00e9poxy<\/td><\/tr><tr><td><\/td><td>Classe de protection<\/td><td>IP20<\/td><\/tr><tr><td><\/td><td>M\u00e9thode de montage<\/td><td>Montage de boulon int\u00e9rieur de type poteau<\/td><\/tr><tr><td><\/td><td>Classe thermique de l'isolation<\/td><td>Classe B (130\u00b0C)<\/td><\/tr><tr><td>Param\u00e8tres environnementaux<\/td><td>Altitude applicable<\/td><td>\u22642000m (personnalisation pour haute altitude disponible)<\/td><\/tr><tr><td><\/td><td>Temp\u00e9rature ambiante de fonctionnement<\/td><td>-30\u00b0C \u00e0 +70\u00b0C<\/td><\/tr><tr><td><\/td><td>Temp\u00e9rature ambiante de stockage<\/td><td>-40\u00b0C \u00e0 +85\u00b0C<\/td><\/tr><tr><td><\/td><td>Humidit\u00e9 relative<\/td><td>\u226495 % (sans condensation)<\/td><\/tr><tr><td>Normes applicables<\/td><td>Normes nationales<\/td><td>GB 1207 Transformateurs de tension ; GB\/T 20840.1 Transformateurs de mesure \u2014 Partie 1 : Exigences g\u00e9n\u00e9rales ; GB\/T 20840.3 Transformateurs de mesure \u2014 Partie 3 : Exigences suppl\u00e9mentaires pour les transformateurs de tension inductifs<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Section IV : Port\u00e9e de l'application<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Classe de tension applicable : syst\u00e8mes d'alimentation CA int\u00e9rieurs de 10 kV (Um=12 kV).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sc\u00e9narios d'application typiques :<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mesure de tension, comptage d'\u00e9nergie et protection de relais dans les appareillages de commutation int\u00e9rieurs moyenne tension (s\u00e9rie KYN28) et les postes sur socle ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Syst\u00e8mes de distribution 10 kV dans les postes \u00e9lectriques, les entreprises industrielles et mini\u00e8res, les immeubles commerciaux et les parcs industriels ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Acquisition des signaux de surveillance, de contr\u00f4le et de protection de la tension dans les syst\u00e8mes d'automatisation de puissance ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Applications int\u00e9rieures de jeux de barres 10 kV n\u00e9cessitant une protection \u00e0 courant limit\u00e9 de haute fiabilit\u00e9, compatible avec les conceptions de jeux de barres compacts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Objectif fonctionnel : Abaisse proportionnellement la haute tension du syst\u00e8me \u00e0 une basse tension standard (100 V) pour fournir des signaux de tension aux instruments de mesure, aux dispositifs de protection et aux \u00e9quipements de commande, tout en assurant l'isolement \u00e9lectrique entre les syst\u00e8mes primaire et secondaire. Le dispositif de protection int\u00e9gr\u00e9 \u00e0 limitation de courant am\u00e9lior\u00e9e assure une protection contre les surintensit\u00e9s. Le type JDZX peut \u00e9galement servir de source de signal de tension pour les dispositifs de surveillance d'isolement afin de d\u00e9tecter les d\u00e9fauts \u00e0 la terre du syst\u00e8me.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Section V : Conditions de service<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Conditions normales de service<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude : \u22642000m ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temp\u00e9rature ambiante : -30\u00b0C \u00e0 +70\u00b0C, sans fluctuations de temp\u00e9rature s\u00e9v\u00e8res ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Humidit\u00e9 relative : \u226495 % (sans condensation) ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conditions environnementales : Absence de gaz corrosifs, de milieux inflammables ou explosifs, de vibrations ou de chocs importants, de poussi\u00e8re ou de brouillard salin significatifs ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Installation : Montage en int\u00e9rieur sur poteau, \u00e0 l'abri de la lumi\u00e8re directe du soleil, de la pluie et de la condensation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Conditions de service sp\u00e9ciales (personnalisation requise)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude sup\u00e9rieure \u00e0 2000m ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temp\u00e9rature ambiante en dehors de la plage de -30\u00b0C \u00e0 +70\u00b0C ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Environnements s\u00e9v\u00e8rement pollu\u00e9s, brouillard salin ou chimiquement corrosifs ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conditions de fonctionnement \u00e0 vibrations ou chocs \u00e9lev\u00e9s ;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ratios de tension non standard, classes de pr\u00e9cision ou exigences de dimensions de montage.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Section VI : Installation et entretien<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Exigences d'installation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Inspection avant installation : Inspectez l'apparence du transformateur de tension \u2014 le corps moul\u00e9 doit \u00eatre exempt de fissures, de vides et de dommages ; les marquages des bornes doivent \u00eatre clairs et tous les accessoires doivent \u00eatre pr\u00e9sents. V\u00e9rifiez que le mod\u00e8le, les sp\u00e9cifications, le rapport de tension, le courant nominal et les exigences de conception sont coh\u00e9rents, et confirmez que la fonction de protection am\u00e9lior\u00e9e de limitation de courant est intacte.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Montage m\u00e9canique : Positionnez le transformateur de tension \u00e0 l'emplacement d\u00e9sign\u00e9 dans l'armoire de commutation et fixez-le avec des boulons \u00e0 travers les trous de montage inf\u00e9rieurs. Assurez-vous que l'installation est ferme, sans jeu ni d\u00e9salignement ; la surface de montage doit \u00eatre plane pour \u00e9viter une charge excentrique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C\u00e2blage c\u00f4t\u00e9 primaire (haute tension) : Connectez les bornes haute tension conform\u00e9ment aux exigences de conception, en assurant des connexions serr\u00e9es avec un bon contact. Maintenez un d\u00e9gagement de s\u00e9curit\u00e9 ad\u00e9quat entre les fils haute tension et les parties mises \u00e0 la terre ou d'autres parties sous tension pour \u00e9viter les d\u00e9charges.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C\u00e2blage du c\u00f4t\u00e9 secondaire (BT) : Connectez les bornes basse tension selon leur marquage, avec un c\u00e2blage s\u00e9par\u00e9 pour les circuits de mesure, de protection et de surveillance d'isolement. Assurez un c\u00e2blage correct ; le circuit secondaire ne doit jamais \u00eatre en court-circuit et doit \u00eatre mis \u00e0 la terre de mani\u00e8re fiable (mise \u00e0 la terre \u00e0 point unique) pour \u00e9viter les surtensions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tests d'isolement : Apr\u00e8s l'installation, mesurez la r\u00e9sistance d'isolement du transformateur de tension (HT vers BT et \u00e0 la terre ; BT vers la terre) pour confirmer que les performances d'isolement r\u00e9pondent aux exigences. V\u00e9rifiez que le c\u00e2blage du circuit secondaire est correct, sans courts-circuits ni circuits ouverts.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Directives de maintenance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Inspectez p\u00e9riodiquement l'aspect du transformateur de tension \u2014 le corps moul\u00e9 doit \u00eatre exempt de fissures, de dommages et de traces de d\u00e9charge ; les bornes haute tension ne doivent pr\u00e9senter aucun jeu ni aucune oxydation ; les capots de protection des bornes secondaires doivent \u00eatre intacts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Inspecter p\u00e9riodiquement le serrage des connexions BT et HT, sans signe de surchauffe ou de d\u00e9coloration ; confirmer la fiabilit\u00e9 de la mise \u00e0 la terre du circuit BT, sans risque de court-circuit ou de circuit ouvert.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tester p\u00e9riodiquement la r\u00e9sistance d'isolement et le rapport de tension pour s'assurer que la pr\u00e9cision du comptage et de la protection r\u00e9pond aux exigences ; v\u00e9rifier \u00e9galement que la fonction de protection am\u00e9lior\u00e9e \u00e0 limitation de courant fonctionne correctement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nettoyez la poussi\u00e8re et les contaminants de la surface du transformateur ; emp\u00eachez les r\u00e9sidus d'huile ou les substances corrosives d'adh\u00e9rer ; gardez l'\u00e9quipement sec et propre.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En cas d'anomalies telles que fissures, d\u00e9charges, surchauffe, \u00e9cart de rapport de tension ou d\u00e9faillance de la fonction de protection, mettez imm\u00e9diatement hors tension pour inspection. Remplacez l'\u00e9quipement si n\u00e9cessaire. Le fonctionnement en conditions de d\u00e9faut est strictement interdit.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Section VII : Pr\u00e9cautions<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le bobinage secondaire ne doit jamais \u00eatre court-circuit\u00e9. Si un court-circuit du circuit secondaire se produit pendant le fonctionnement, le dispositif de protection am\u00e9lior\u00e9 \u00e0 limitation de courant s'activera pour prot\u00e9ger l'\u00e9quipement ; cependant, le d\u00e9faut doit n\u00e9anmoins \u00eatre investigu\u00e9 et \u00e9limin\u00e9 rapidement. Pendant la maintenance, le circuit secondaire doit \u00eatre de mani\u00e8re fiable ouvert et mis \u00e0 la terre.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c9vitez de heurter ou d'impacter le corps moul\u00e9 du transformateur de tension pendant l'installation afin d'\u00e9viter la fissuration de la r\u00e9sine \u00e9poxy et les dommages \u00e0 l'isolation, ce qui compromettrait les performances d'isolation de l'\u00e9quipement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le c\u00e2blage du c\u00f4t\u00e9 haute tension doit utiliser des fils isol\u00e9s d\u00e9di\u00e9s, en maintenant un d\u00e9gagement de s\u00e9curit\u00e9 ad\u00e9quat par rapport aux pi\u00e8ces mises \u00e0 la terre et aux autres pi\u00e8ces sous tension afin d'\u00e9viter les d\u00e9charges entre phases ou entre phase et terre.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La mise \u00e0 la terre de l'\u00e9quipement doit \u00eatre fiable ; le bornier de terre de base doit \u00eatre solidement connect\u00e9 \u00e0 la barre omnibus de terre de l'armoire pour assurer une mise \u00e0 la terre correcte de l'\u00e9quipement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pendant le stockage, conservez l'appareil dans un environnement sec, bien ventil\u00e9 et frais, \u00e0 l'abri de la lumi\u00e8re directe du soleil, des temp\u00e9ratures \u00e9lev\u00e9es, de l'humidit\u00e9 et de la compression m\u00e9canique, afin d'\u00e9viter le vieillissement ou la d\u00e9formation du corps moul\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'installation, la mise en service et la maintenance doivent \u00eatre effectu\u00e9es par du personnel qualifi\u00e9 en \u00e9lectricit\u00e9, dans le strict respect des proc\u00e9dures d'exploitation en mati\u00e8re de s\u00e9curit\u00e9 \u00e9lectrique.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Section VIII : Port\u00e9e standard de l'approvisionnement<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Num\u00e9ro d'article<\/th><th>Description<\/th><th>Objectif<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Transformateur de tension JDZ(X)10-10-3, 6\/10B (RZL-10) Corps<\/td><td>\u00c9quipement principal assurant la transformation de tension, l'isolement, une protection am\u00e9lior\u00e9e contre la limitation de courant et l'acquisition de signaux<\/td><\/tr><tr><td>2<\/td><td>Boulons et rondelles de montage<\/td><td>Pour la fixation m\u00e9canique du transformateur de tension<\/td><\/tr><tr><td>3<\/td><td>Couvercle de protection transparent du terminal secondaire<\/td><td>Prot\u00e8ge les bornes de c\u00e2blage basse tension contre les erreurs de c\u00e2blage et les courts-circuits<\/td><\/tr><tr><td>4<\/td><td>Manuel du produit<\/td><td>Guide d'installation, d'utilisation et de maintenance, incluant des instructions de protection am\u00e9lior\u00e9e contre la limitation de courant<\/td><\/tr><tr><td>5<\/td><td>Certificat de conformit\u00e9 produit et rapport d'essai en usine<\/td><td>Documentation sur la qualit\u00e9 et les performances du produit, y compris les donn\u00e9es de rapport de tension, d'erreur et de test de protection contre les surintensit\u00e9s<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Section IX : Normes et certifications applicables<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ce produit est conforme aux normes nationales suivantes : GB 1207 Transformateurs de tension, GB\/T 20840.1 Transformateurs de mesure \u2014 Partie 1 : Exigences g\u00e9n\u00e9rales, et GB\/T 20840.3 Transformateurs de mesure \u2014 Partie 3 : Exigences suppl\u00e9mentaires pour les transformateurs de tension inductifs. Le produit a pass\u00e9 des essais de type et ses performances r\u00e9pondent aux exigences op\u00e9rationnelles des r\u00e9seaux \u00e9lectriques int\u00e9rieurs de 10 kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Annexe : Sch\u00e9ma de principe du produit<\/p>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>JDZ(X)10-10-3\u30016\/10B(RZL-10) Voltage Transformer Section I: Product Overview The JDZ(X)10-10-3\u30016\/10B(RZL-10) voltage transformer is a fully-enclosed, dry-type, cast-resin voltage transformer designed specifically [&hellip;]<\/p>\n","protected":false},"featured_media":3040,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[30],"class_list":["post-1613","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-instrument-transformer-series"],"acf":{"products_imagines":[3040],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/products\/1613","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/3040"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/3040"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media?parent=1613"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/product_category?post=1613"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}