{"id":1625,"date":"2026-05-08T00:00:00","date_gmt":"2026-05-08T00:00:00","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1625"},"modified":"2026-09-15T02:41:02","modified_gmt":"2026-09-15T02:41:02","slug":"three-phase-three-wire-dry-type-metering-unit","status":"publish","type":"products","link":"https:\/\/yieou.com\/fr\/product\/three-phase-three-wire-dry-type-metering-unit\/","title":{"rendered":"Unit\u00e9 de mesure triphas\u00e9e tri-fils de type sec JLSZV-6\/10"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Aper\u00e7u du produit<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/fr\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">L'unit\u00e9 de mesure triphas\u00e9e tri-fils de type sec JLSZV-6\/10<\/a> est un appareil de mesure int\u00e9gr\u00e9 haute tension con\u00e7u pour les syst\u00e8mes d'alimentation CA de 6 kV et 10 kV en int\u00e9rieur et en ext\u00e9rieur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fabriqu\u00e9e par un proc\u00e9d\u00e9 de coul\u00e9e sous vide en r\u00e9sine \u00e9poxy, l'unit\u00e9 int\u00e8gre des transformateurs de tension et des transformateurs de courant dans un corps moul\u00e9 unique, permettant l'acquisition simultan\u00e9e des signaux de tension et de courant.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il est principalement utilis\u00e9 pour le comptage d'\u00e9nergie, la surveillance des param\u00e8tres \u00e9lectriques et la gestion de la charge dans les r\u00e9seaux de distribution triphas\u00e9s \u00e0 trois fils. Les applications typiques comprennent les lignes de distribution de 6 kV et 10 kV, les postes de transformation compacts, les postes de coupure, les entreprises industrielles et mini\u00e8res, les immeubles commerciaux et autres syst\u00e8mes d'alimentation moyenne tension.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Caract\u00e9ristiques du produit<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Isolation et performance \u00e9lectrique<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Isolation en r\u00e9sine coul\u00e9e int\u00e9gr\u00e9e :<\/strong><br>Les composants des transformateurs de tension et de courant sont form\u00e9s de mani\u00e8re int\u00e9grale par un proc\u00e9d\u00e9 de coul\u00e9e sous vide en r\u00e9sine \u00e9poxy. L'isolation solide ne contient pas de vides d'air internes et offre d'excellentes performances di\u00e9lectriques.<\/li>\n\n\n\n<li><strong>Capacit\u00e9 de tenue d'isolement \u00e9lev\u00e9e.<\/strong><br>L'unit\u00e9 peut supporter les exigences sp\u00e9cifi\u00e9es en mati\u00e8re de tenue \u00e0 la tension de fr\u00e9quence industrielle et de tenue au choc de foudre des r\u00e9seaux 6 kV ou 10 kV correspondants.<\/li>\n\n\n\n<li><strong>Faible d\u00e9charge partielle :<\/strong><br>La d\u00e9charge partielle est limit\u00e9e \u00e0 10 pC maximum, contribuant \u00e0 r\u00e9duire le vieillissement de l'isolation et \u00e0 am\u00e9liorer la fiabilit\u00e9 op\u00e9rationnelle \u00e0 long terme.<\/li>\n\n\n\n<li><strong>Construction sans huile de type sec :<\/strong><br>Le produit ne contient pas d'huile isolante, \u00e9liminant ainsi les risques de fuite d'huile, de contamination par l'huile et d'incendie li\u00e9 \u00e0 l'huile. Il convient aux syst\u00e8mes de distribution d'\u00e9nergie sans huile, int\u00e9rieurs et ext\u00e9rieurs.<\/li>\n\n\n\n<li><strong>Acquisition simultan\u00e9e de la tension et du courant :<\/strong><br>L'unit\u00e9 int\u00e8gre des transformateurs de tension triphas\u00e9s et des transformateurs de courant biphas\u00e9s conform\u00e9ment \u00e0 un sch\u00e9ma de comptage triphas\u00e9 \u00e0 trois fils. Elle acquiert simultan\u00e9ment des signaux de tension triphas\u00e9e et de courant biphas\u00e9 pour le comptage d'\u00e9nergie, le calcul de puissance et la surveillance de charge.<\/li>\n\n\n\n<li><strong>Large plage de rapports :<\/strong><br>Des rapports de tension tels que 6\/0,1 kV et 10\/0,1 kV sont disponibles. Des rapports de courant de 5\/5 A \u00e0 2 000\/5 A peuvent \u00eatre configur\u00e9s selon les exigences de charge.<\/li>\n\n\n\n<li><strong>Pr\u00e9cision de mesure \u00e9lev\u00e9e :<\/strong><br>Des transformateurs de courant de classes de pr\u00e9cision jusqu'\u00e0 0,2S et des transformateurs de tension de classes de pr\u00e9cision jusqu'\u00e0 0,2 sont disponibles. Les classes 0,5 et 1 peuvent \u00e9galement \u00eatre fournies selon les exigences de mesurage ou de surveillance.<\/li>\n\n\n\n<li><strong>Haute r\u00e9sistance au pollution-flashover :<\/strong><br>Le c\u00f4t\u00e9 haute tension pr\u00e9sente une structure d'isolation \u00e0 plusieurs jupes avec une distance de fuite \u00e9tendue. Cela am\u00e9liore la r\u00e9sistance au claquage de surface dans les environnements ext\u00e9rieurs humides, pollu\u00e9s et expos\u00e9s.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Caract\u00e9ristiques structurelles et d'installation<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Structure int\u00e9gr\u00e9e de type sec :<\/strong><br>L'ensemble de mesure complet est enferm\u00e9 dans un corps unique en r\u00e9sine coul\u00e9e, sans composants internes sous tension expos\u00e9s.<\/li>\n\n\n\n<li><strong>Versions int\u00e9rieures et ext\u00e9rieures :<\/strong><br>Les mod\u00e8les d'ext\u00e9rieur offrent un indice de protection IP65, tandis que les mod\u00e8les d'int\u00e9rieur offrent un indice de protection IP20.<\/li>\n\n\n\n<li><strong>Construction compacte :<\/strong><br>L'int\u00e9gration des transformateurs de tension et de courant en une seule unit\u00e9 r\u00e9duit le nombre de composants distincts, \u00e9conomise de l'espace d'installation et simplifie le c\u00e2blage sur site.<\/li>\n\n\n\n<li><strong>Conception de mesure triphas\u00e9e trois fils :<\/strong><br>L'unit\u00e9 utilise un dispositif de mesure \u00e0 deux \u00e9l\u00e9ments adapt\u00e9 aux syst\u00e8mes triphas\u00e9s trois fils, y compris les syst\u00e8mes avec neutres non efficacement mis \u00e0 la terre.<\/li>\n\n\n\n<li><strong>Connexion directe au compteur :<\/strong><br>Les circuits secondaires peuvent \u00eatre connect\u00e9s directement \u00e0 un compteur d'\u00e9nergie triphas\u00e9 trois fils compatible sans n\u00e9cessiter de transformateurs de mesure suppl\u00e9mentaires.<\/li>\n\n\n\n<li><strong>Bornes clairement identifi\u00e9es :<\/strong><br>Le c\u00f4t\u00e9 haute tension utilise des bornes ou des plaques de bornes d\u00e9di\u00e9es. Les bornes de tension et de courant secondaires sont clairement marqu\u00e9es et regroup\u00e9es s\u00e9par\u00e9ment pour r\u00e9duire le risque de c\u00e2blage incorrect.<\/li>\n\n\n\n<li><strong>Installation flexible :<\/strong><br>L'unit\u00e9 prend en charge le montage sur poteau ext\u00e9rieur, en int\u00e9rieur <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a> installation, et installation \u00e0 l'int\u00e9rieur des postes de transformation de type cabine.<\/li>\n\n\n\n<li><strong>Haute stabilit\u00e9 m\u00e9canique :<\/strong><br>La structure de montage offre une r\u00e9sistance fiable aux vibrations et aux charges de vent lorsqu'elle est correctement install\u00e9e.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Fonctionnalit\u00e9s d'exploitation et de maintenance<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Fonctionnement \u00e0 faible entretien :<\/strong><br>La conception s\u00e8che et sans huile \u00e9limine les fuites d'huile, le remplacement de l'huile et les risques d'incendie li\u00e9s \u00e0 l'huile.<\/li>\n\n\n\n<li><strong>Haute r\u00e9sistance m\u00e9canique :<\/strong><br>Le corps moul\u00e9 en r\u00e9sine \u00e9poxy offre une r\u00e9sistance fiable aux chocs, au vieillissement et \u00e0 la corrosion.<\/li>\n\n\n\n<li><strong>Large plage de temp\u00e9ratures de fonctionnement :<\/strong><br>L'unit\u00e9 peut fonctionner \u00e0 des temp\u00e9ratures ambiantes comprises entre -40\u00b0C et +70\u00b0C. La r\u00e9sine \u00e9poxy maintient des propri\u00e9t\u00e9s d'isolation et m\u00e9caniques stables dans des conditions de haute et basse temp\u00e9rature.<\/li>\n\n\n\n<li><strong>R\u00e9sistance aux intemp\u00e9ries ext\u00e9rieures :<\/strong><br>Les mod\u00e8les d'ext\u00e9rieur peuvent r\u00e9sister \u00e0 une exposition normale au soleil, \u00e0 la pluie, au gel, au vent et aux variations de temp\u00e9rature.<\/li>\n\n\n\n<li><strong>Haute fiabilit\u00e9 op\u00e9rationnelle :<\/strong><br>Les transformateurs de tension et de courant utilisent des noyaux magn\u00e9tiques et des mat\u00e9riaux de bobinage de haute qualit\u00e9, offrant de faibles pertes de fonctionnement, une \u00e9l\u00e9vation de temp\u00e9rature limit\u00e9e et une pr\u00e9cision de mesure stable.<\/li>\n\n\n\n<li><strong>Pr\u00e9cision stable \u00e0 long terme :<\/strong><br>Le produit est con\u00e7u pour minimiser la d\u00e9rive de pr\u00e9cision lors d'un fonctionnement \u00e0 long terme.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Sp\u00e9cifications techniques<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Param\u00e8tres \u00e9lectriques<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Param\u00e8tre<\/th><th>Sp\u00e9cification<\/th><\/tr><\/thead><tbody><tr><td>Tension de syst\u00e8me applicable<\/td><td>6 kV \/ 10 kV CA, Um = 7,2 kV \/ 12 kV<\/td><\/tr><tr><td>Fr\u00e9quence nominale<\/td><td>50 Hz<\/td><\/tr><tr><td>Rapport de tension<\/td><td>6\/0,1 kV ou 10\/0,1 kV, personnalisable<\/td><\/tr><tr><td>Ratio de liquidit\u00e9 g\u00e9n\u00e9rale<\/td><td>De 5\/5 A \u00e0 2 000\/5 A, personnalisable<\/td><\/tr><tr><td>Classe de pr\u00e9cision du transformateur de tension<\/td><td>Classe 0,2 \/ 0,5 \/ 1<\/td><\/tr><tr><td>Classe de pr\u00e9cision actuelle du transformateur<\/td><td>Classe 0,2S \/ 0,5S \/ 0,5<\/td><\/tr><tr><td>Tension de tenue \u00e0 la fr\u00e9quence industrielle<\/td><td>28 kV pendant 1 minute pour les mod\u00e8les 6 kV ; 42 kV pendant 1 minute pour les mod\u00e8les 10 kV, sans claquage<\/td><\/tr><tr><td>Tension de tenue aux ondes de choc de foudre<\/td><td>60 kV cr\u00eate pour les mod\u00e8les 6 kV ; 75 kV cr\u00eate pour les mod\u00e8les 10 kV, sans claquage<\/td><\/tr><tr><td>D\u00e9charge partielle<\/td><td>\u226410 pC<\/td><\/tr><tr><td>R\u00e9sistance d'isolement<\/td><td>\u22651,000 M\u03a9 between high voltage, low voltage, and earth<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Param\u00e8tres structurels et mat\u00e9riels<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Param\u00e8tre<\/th><th>Sp\u00e9cification<\/th><\/tr><\/thead><tbody><tr><td>Milieu isolant<\/td><td>Coul\u00e9e \u00e9poxy int\u00e9gr\u00e9e<\/td><\/tr><tr><td>Indice de protection<\/td><td>IP65 pour les mod\u00e8les d'ext\u00e9rieur ; IP20 pour les mod\u00e8les d'int\u00e9rieur<\/td><\/tr><tr><td>Type d'installation<\/td><td>Montage sur poteau, installation de tableaux \u00e9lectriques en int\u00e9rieur ou installation de postes de transformation de type cabine<\/td><\/tr><tr><td>Classe thermique<\/td><td>Classe B, 130\u00b0C<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Param\u00e8tres environnementaux<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Param\u00e8tre<\/th><th>Sp\u00e9cification<\/th><\/tr><\/thead><tbody><tr><td>Installation Altitude<\/td><td>\u2264 2 000 m ; versions haute altitude disponibles<\/td><\/tr><tr><td>Temp\u00e9rature de fonctionnement<\/td><td>-40\u00b0C \u00e0 +70\u00b0C<\/td><\/tr><tr><td>Temp\u00e9rature de stockage<\/td><td>-40\u00b0C \u00e0 +85\u00b0C<\/td><\/tr><tr><td>Humidit\u00e9 relative<\/td><td>\u226495 %, sans condensation<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Normes applicables<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Standard<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td>GB 1207<\/td><td>Transformateurs de tension<\/td><\/tr><tr><td>GB 1208<\/td><td>Transformateurs actuels<\/td><\/tr><tr><td>GB\/T 17215<\/td><td>Compteurs \u00e9lectriques<\/td><\/tr><tr><td>DL\/T 448<\/td><td>Code technique administratif pour le mesurage de l'\u00e9nergie \u00e9lectrique<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Applications<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Syst\u00e8mes d'alimentation applicables<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L'unit\u00e9 de mesure JLSZV-6\/10 convient aux syst\u00e8mes d'alimentation CA triphas\u00e9s trois fils de 6 kV et 10 kV avec des tensions maximales de syst\u00e8me de 7,2 kV et 12 kV.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Applications typiques<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Compteurs d'\u00e9nergie mont\u00e9s sur poteau sur les lignes de distribution ext\u00e9rieures<\/li>\n\n\n\n<li>Mesure d'\u00e9nergie et surveillance de charge dans les appareillages de commutation int\u00e9rieurs moyenne tension<\/li>\n\n\n\n<li>Postes de transformation de type cabine<\/li>\n\n\n\n<li>Postes de commutation et de distribution<\/li>\n\n\n\n<li>Syst\u00e8mes de distribution 6 kV et 10 kV dans les entreprises industrielles et mini\u00e8res<\/li>\n\n\n\n<li>B\u00e2timents commerciaux et parcs industriels<\/li>\n\n\n\n<li>Acquisition de donn\u00e9es \u00e9nerg\u00e9tiques dans les syst\u00e8mes d'automatisation de puissance<\/li>\n\n\n\n<li>Syst\u00e8mes de surveillance, de contr\u00f4le et de gestion de la charge de puissance<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Fonctions principales<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L'unit\u00e9 de mesure convertit la haute tension du syst\u00e8me et le courant primaire en signaux secondaires normalis\u00e9s :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tension de sortie : 100 V<\/li>\n\n\n\n<li>Sortie actuelle : 5 A<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ces signaux peuvent \u00eatre fournis \u00e0 :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Compteurs d'\u00e9nergie triphas\u00e9s trois fils<\/li>\n\n\n\n<li>Instruments de mesure<\/li>\n\n\n\n<li>\u00c9quipement de surveillance de puissance<\/li>\n\n\n\n<li>Syst\u00e8mes de gestion de la charge<\/li>\n\n\n\n<li>Acquisition de donn\u00e9es<\/li>\n\n\n\n<li>Syst\u00e8mes d'automatisation de puissance<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L'unit\u00e9 prend en charge :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mesure d'\u00e9nergie<\/li>\n\n\n\n<li>Calcul de puissance<\/li>\n\n\n\n<li>Surveillance de la charge<\/li>\n\n\n\n<li>Acquisition de param\u00e8tres \u00e9lectriques<\/li>\n\n\n\n<li>Analyse de la consommation<\/li>\n\n\n\n<li>Gestion de l'\u00e9nergie<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Il assure \u00e9galement une isolation \u00e9lectrique entre le syst\u00e8me d'alimentation primaire et les circuits de mesure secondaires, contribuant ainsi \u00e0 prot\u00e9ger l'\u00e9quipement connect\u00e9 et le personnel d'exploitation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conditions d'exploitation<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Conditions normales de fonctionnement<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Altitude d'installation : pas plus de 2 000 m<\/li>\n\n\n\n<li>Temp\u00e9rature ambiante : -40\u00b0C \u00e0 +70\u00b0C<\/li>\n\n\n\n<li>Il faut \u00e9viter les changements de temp\u00e9rature brusques ou extr\u00eames.<\/li>\n\n\n\n<li>Humidit\u00e9 relative : 95 % maximum, sans condensation<\/li>\n\n\n\n<li>L'environnement doit \u00eatre exempt de gaz corrosifs<\/li>\n\n\n\n<li>Les substances inflammables ou explosives sont interdites<\/li>\n\n\n\n<li>Il faut \u00e9viter les vibrations fortes et les chocs m\u00e9caniques.<\/li>\n\n\n\n<li>Les mod\u00e8les d'ext\u00e9rieur peuvent r\u00e9sister \u00e0 une exposition normale au soleil, \u00e0 la pluie, au gel et au vent.<\/li>\n\n\n\n<li>Installation ext\u00e9rieure sur poteau ou int\u00e9rieure de postes de coupure<\/li>\n\n\n\n<li>Les environnements pr\u00e9sentant une corrosion s\u00e9v\u00e8re, des embruns salins ou des temp\u00eates de sable doivent \u00eatre \u00e9vit\u00e9s, sauf si un mod\u00e8le personnalis\u00e9 est utilis\u00e9.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Conditions d'exploitation sp\u00e9ciales<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les produits personnalis\u00e9s sont requis pour :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Altitudes d'installation sup\u00e9rieures \u00e0 2 000 m<\/li>\n\n\n\n<li>Temp\u00e9ratures ambiantes en dehors de la plage de -40\u00b0C \u00e0 +70\u00b0C<\/li>\n\n\n\n<li>Environnements de pollution s\u00e9v\u00e8re ou de brouillard salin<\/li>\n\n\n\n<li>Environnements chimiquement corrosifs<\/li>\n\n\n\n<li>Fort vent ou conditions de sable et de poussi\u00e8re s\u00e9v\u00e8res<\/li>\n\n\n\n<li>Exposition aux ultraviolets de haute intensit\u00e9<\/li>\n\n\n\n<li>Rapports de tension non standard<\/li>\n\n\n\n<li>Ratios de courant non standard<\/li>\n\n\n\n<li>Dimensions de montage sp\u00e9ciales<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Installation et entretien<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Exigences d'installation<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Inspection avant installation :<\/strong><br>Inspectez l'unit\u00e9 de mesure et v\u00e9rifiez que le corps en r\u00e9sine \u00e9poxy est exempt de fissures, de bulles, de dommages m\u00e9caniques et d'autres d\u00e9fauts visibles. V\u00e9rifiez que toutes les marques de bornes sont claires et que les accessoires fournis sont complets. V\u00e9rifiez que le mod\u00e8le, le rapport de tension, le rapport de courant et les classes de pr\u00e9cision correspondent \u00e0 la conception du syst\u00e8me et aux exigences de mesure.<\/li>\n\n\n\n<li><strong>Montage :<\/strong><br>S\u00e9lectionnez un support de montage appropri\u00e9 en fonction de la m\u00e9thode d'installation. Fixez l'unit\u00e9 de mesure en position et v\u00e9rifiez qu'il n'y a aucun jeu, d\u00e9placement ou charge m\u00e9canique in\u00e9gale. La position de montage peut \u00eatre horizontale ou verticale selon la conception du produit. Les installations sur poteau doivent satisfaire aux exigences sp\u00e9cifi\u00e9es en mati\u00e8re de charge de vent et de r\u00e9sistance au renversement.<\/li>\n\n\n\n<li><strong>Connexion c\u00f4t\u00e9 haute tension :<\/strong><br>Connectez les bornes haute tension conform\u00e9ment \u00e0 la conception du syst\u00e8me. Assurez-vous que toutes les connexions sont solidement serr\u00e9es et qu'elles assurent un contact \u00e9lectrique fiable. Maintenez un d\u00e9gagement \u00e9lectrique ad\u00e9quat entre les conducteurs haute tension, les composants mis \u00e0 la terre et les autres pi\u00e8ces sous tension. Les connexions haute tension ext\u00e9rieures doivent \u00eatre correctement prot\u00e9g\u00e9es contre l'infiltration d'eau et la corrosion.<\/li>\n\n\n\n<li><strong>Connexion secondaire :<\/strong><br>Connectez les bornes secondaires de tension et de courant au compteur d'\u00e9nergie conform\u00e9ment \u00e0 leur marquage. Le circuit secondaire du transformateur de courant ne doit jamais \u00eatre laiss\u00e9 ouvert lorsque le circuit primaire est sous tension. Le circuit secondaire du transformateur de tension ne doit jamais \u00eatre court-circuit\u00e9. Le circuit secondaire de courant requis doit \u00eatre mis \u00e0 la terre de mani\u00e8re fiable en un point, conform\u00e9ment \u00e0 la conception du syst\u00e8me et aux exigences de s\u00e9curit\u00e9 \u00e9lectrique applicables.<\/li>\n\n\n\n<li><strong>Inspection de l'isolation<\/strong><br>Apr\u00e8s l'installation, mesurez la r\u00e9sistance d'isolement entre :<ul><li>Haute tension et basse tension<\/li><li>Haute tension et terre<\/li><li>Basse tension et terre<\/li><\/ul>Confirmez que les circuits secondaires de tension et de courant sont correctement connect\u00e9s et exempts de courts-circuits ou de circuits ouverts involontaires. V\u00e9rifiez le c\u00e2blage du compteur d'\u00e9nergie et la s\u00e9quence de phase avant de mettre le syst\u00e8me sous tension.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Exigences de maintenance<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Inspectez r\u00e9guli\u00e8rement le corps en r\u00e9sine \u00e9poxy pour d\u00e9tecter les fissures, les dommages m\u00e9caniques, les traces de d\u00e9charge et la contamination.<\/li>\n\n\n\n<li>V\u00e9rifiez les bornes haute tension pour d\u00e9celer tout desserrage, oxydation, corrosion ou \u00e9chauffement anormal.<\/li>\n\n\n\n<li>Pour les mod\u00e8les ext\u00e9rieurs, inspectez l'\u00e9tanch\u00e9it\u00e9 des bornes et la protection contre la corrosion.<\/li>\n\n\n\n<li>V\u00e9rifiez r\u00e9guli\u00e8rement toutes les connexions haute et basse tension pour d\u00e9tecter tout desserrage, surchauffe et d\u00e9coloration.<\/li>\n\n\n\n<li>Confirmez que le circuit secondaire actuel reste correctement connect\u00e9 et mis \u00e0 la terre de mani\u00e8re fiable.<\/li>\n\n\n\n<li>V\u00e9rifiez p\u00e9riodiquement la pr\u00e9cision du comptage en comparant les relev\u00e9s du compteur d'\u00e9nergie avec les limites d'erreur sp\u00e9cifi\u00e9es de l'unit\u00e9 de mesure.<\/li>\n\n\n\n<li>Testez p\u00e9riodiquement la r\u00e9sistance d'isolement et confirmez que les performances d'isolement restent dans les limites sp\u00e9cifi\u00e9es.<\/li>\n\n\n\n<li>Nettoyez la poussi\u00e8re et la contamination de la surface de l'unit\u00e9 de mesure.<\/li>\n\n\n\n<li>Pour les mod\u00e8les ext\u00e9rieurs, nettoyez r\u00e9guli\u00e8rement les capots isolants pour r\u00e9duire le risque de d\u00e9faillance par pollution.<\/li>\n\n\n\n<li>Emp\u00eacher les huiles et les substances corrosives d'entrer en contact avec le corps en r\u00e9sine \u00e9poxy.<\/li>\n\n\n\n<li>En cas de craquement, de d\u00e9charge \u00e9lectrique, de surchauffe ou d'erreur de mesure excessive, coupez imm\u00e9diatement l'alimentation et inspectez l'\u00e9quipement. Remplacez l'unit\u00e9 si n\u00e9cessaire.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Pr\u00e9cautions<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Le circuit secondaire du transformateur de courant ne doit jamais \u00eatre laiss\u00e9 ouvert lorsque le syst\u00e8me primaire est sous tension. Le circuit secondaire du transformateur de tension ne doit jamais \u00eatre court-circuit\u00e9. L'une ou l'autre de ces conditions peut produire une surtension ou un surintensit\u00e9 dangereuse et cr\u00e9er un risque grave pour le mat\u00e9riel et le personnel.<\/li>\n\n\n\n<li>Lors de la maintenance, le circuit secondaire courant doit \u00eatre court-circuit\u00e9 et mis \u00e0 la terre de mani\u00e8re s\u00fbre avant d'\u00eatre d\u00e9connect\u00e9. Le circuit secondaire de tension doit \u00eatre isol\u00e9 en toute s\u00e9curit\u00e9 avant le d\u00e9but des travaux.<\/li>\n\n\n\n<li>\u00c9vitez tout impact ou collision avec le corps en r\u00e9sine \u00e9poxy et les bornes haute tension pendant le transport et l'installation. Les dommages m\u00e9caniques peuvent r\u00e9duire les performances d'isolation et la r\u00e9sistance au pollution-flashover.<\/li>\n\n\n\n<li>Utilisez des conducteurs isol\u00e9s appropri\u00e9s pour les connexions haute tension. Maintenez une distance d'isolement \u00e9lectrique ad\u00e9quate par rapport aux composants mis \u00e0 la terre et aux autres pi\u00e8ces sous tension pour \u00e9viter les d\u00e9charges entre phases ou entre phase et terre.<\/li>\n\n\n\n<li>Confirmez la s\u00e9quence de phase correcte lors du c\u00e2blage triphas\u00e9. Des connexions de phase incorrectes peuvent affecter la pr\u00e9cision du comptage et le fonctionnement du syst\u00e8me.<\/li>\n\n\n\n<li>L'\u00e9quipement doit \u00eatre mis \u00e0 la terre de mani\u00e8re fiable. La borne de mise \u00e0 la terre sur la base doit \u00eatre solidement connect\u00e9e \u00e0 la terre. <a href=\"https:\/\/en.wikipedia.org\/wiki\/Busbar\" target=\"_blank\" rel=\"noopener\">barre omnibus<\/a>.<\/li>\n\n\n\n<li>Les mod\u00e8les ext\u00e9rieurs doivent \u00eatre conformes aux exigences applicables en mati\u00e8re de protection contre la foudre et de mise \u00e0 la terre.<\/li>\n\n\n\n<li>Conserver le produit dans un environnement sec, ventil\u00e9 et \u00e0 l'abri de la lumi\u00e8re. \u00c9viter la lumi\u00e8re directe du soleil, les temp\u00e9ratures \u00e9lev\u00e9es, l'humidit\u00e9, la compression et les chocs m\u00e9caniques.<\/li>\n\n\n\n<li>L'installation, la mise en service et la maintenance doivent \u00eatre effectu\u00e9es par du personnel qualifi\u00e9 en \u00e9lectricit\u00e9, conform\u00e9ment aux proc\u00e9dures de s\u00e9curit\u00e9 \u00e9lectrique applicables.<\/li>\n\n\n\n<li>L'unit\u00e9 de mesure doit passer la v\u00e9rification par l'autorit\u00e9 locale de m\u00e9trologie comp\u00e9tente avant d'\u00eatre mise en service, lorsque cette v\u00e9rification est requise.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Liste d'approvisionnement standard<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Non.<\/th><th>Article<\/th><th>Fonction<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Unit\u00e9 de mesure triphas\u00e9e tri-fils de type sec JLSZV-6\/10<\/td><td>Dispositif principal pour la transformation de tension et de courant, l'isolation \u00e9lectrique et le comptage d'\u00e9nergie<\/td><\/tr><tr><td>2<\/td><td>Supports de montage, boulons et rondelles<\/td><td>Utilis\u00e9 pour fixer le compteur lors de l'installation<\/td><\/tr><tr><td>3<\/td><td>Couvercle de borne secondaire<\/td><td>Prot\u00e8ge les bornes basse tension et aide \u00e0 pr\u00e9venir les connexions incorrectes ou les courts-circuits<\/td><\/tr><tr><td>4<\/td><td>Manuel d'instructions du produit<\/td><td>Fournit des instructions pour l'installation, le fonctionnement, la maintenance et le c\u00e2blage des circuits de mesure<\/td><\/tr><tr><td>5<\/td><td>Certificat de produit, rapport d'essai d'usine et certificat de v\u00e9rification m\u00e9trologique<\/td><td>Fournit la documentation sur la qualit\u00e9 et les performances du produit, y compris les donn\u00e9es de test de rapport tension, rapport courant et pr\u00e9cision.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Normes applicables et certification<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le produit est conforme aux normes suivantes :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GB 1207, <em>Transformateurs de tension<\/em><\/li>\n\n\n\n<li>GB 1208, <em>Transformateurs actuels<\/em><\/li>\n\n\n\n<li>GB\/T 17215, <em>Compteurs \u00e9lectriques<\/em><\/li>\n\n\n\n<li>DL\/T 448, <em>Code technique administratif pour le mesurage de l'\u00e9nergie \u00e9lectrique<\/em><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Le produit a pass\u00e9 les essais de type applicables et la v\u00e9rification m\u00e9trologique. Ses performances r\u00e9pondent aux exigences de comptage d'\u00e9nergie des r\u00e9seaux \u00e9lectriques triphas\u00e9s trois fils de 6 kV et 10 kV.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"939\" height=\"738\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1.webp\" alt=\"JLSZV-6 10 Unit\u00e9 de comptage triphas\u00e9e tri-fils de type sec (1)\" class=\"wp-image-2586\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1.webp 939w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1-300x236.webp 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1-768x604.webp 768w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1-15x12.webp 15w\" sizes=\"(max-width: 939px) 100vw, 939px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The JLSZV-6\/10 Three-Phase Three-Wire Dry-Type Metering Unit is an integrated high-voltage metering device designed for indoor and outdoor [&hellip;]<\/p>\n","protected":false},"featured_media":2585,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[30],"class_list":["post-1625","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-instrument-transformer-series"],"acf":{"products_imagines":[2585],"short_describe":"<p>The JLSZV-6\/10 Three-Phase Three-Wire Dry-Type Metering Unit is an integrated high-voltage metering device designed for indoor and outdoor 6 kV and 10 kV AC power systems.<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/products\/1625","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/2585"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/2585"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media?parent=1625"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/product_category?post=1625"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}