{"id":378,"date":"2026-01-23T05:25:26","date_gmt":"2026-01-23T05:25:26","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=378"},"modified":"2026-09-15T07:06:52","modified_gmt":"2026-09-15T07:06:52","slug":"jy-nz-3540-5-35kv-inner-cone-plug-in-terminal","status":"publish","type":"products","link":"https:\/\/yieou.com\/fr\/product\/jy-nz-3540-5-35kv-inner-cone-plug-in-terminal\/","title":{"rendered":"JY NZ-35(40.5)-\u25a1 Borne \u00e0 c\u00f4ne int\u00e9rieur enfichable 35kV"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>I. Aper\u00e7u du produit<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/fr\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">Le terminal \u00e0 c\u00f4ne int\u00e9rieur enfichable JY NZ-35 (40,5)-\u25a1 35kV<\/a> est d\u00e9tachable <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_cable\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_cable\" target=\"_blank\" rel=\"noopener\">cable <\/a>terminal sp\u00e9cialement con\u00e7u pour les syst\u00e8mes de distribution d'\u00e9nergie \u00e0 haute tension de 35 kV (Um=40,5 kV). Il est dot\u00e9 d'une structure interne \u00e0 c\u00f4ne enfichable et peut \u00eatre utilis\u00e9 directement avec des douilles isol\u00e9es \u00e0 c\u00f4ne interne #1\/#2\/#3. Cela permet l'isolement di\u00e9lectrique, la connexion conductrice et la protection d'\u00e9tanch\u00e9it\u00e9 entre les c\u00e2bles et les \u00e9quipements de distribution d'\u00e9nergie.<a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a>, postes de coupure, postes pr\u00e9fabriqu\u00e9s). Aucun traitement de gaz ou d'huile isolante sur site n'est requis. Il est facile \u00e0 installer et tr\u00e8s efficace \u00e0 entretenir, ce qui en fait un composant cl\u00e9 dans la construction d'interfaces de c\u00e2bles d\u00e9tachables pour les syst\u00e8mes de distribution d'\u00e9nergie haute tension.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II. Caract\u00e9ristiques du produit<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Propri\u00e9t\u00e9s \u00e9lectriques et d'isolation<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fabriqu\u00e9 en <strong>haute puret\u00e9<\/strong> <strong>silicone<\/strong> <strong>caoutchouc<\/strong> Gr\u00e2ce au moulage par injection int\u00e9gral, il est sans soudure et sans espace d'air, avec d'excellentes performances d'isolation. Il peut supporter la tension nominale du syst\u00e8me de 35 kV et les surtensions de courte dur\u00e9e, et r\u00e9pondre aux exigences de fonctionnement de la tension de travail maximale de 40,5 kV. Il dispose d'une marge d'isolation suffisante et d'une d\u00e9charge partielle \u226410 pC (1,5 U\u2080).<\/li>\n\n\n\n<li>Gr\u00e2ce \u00e0 une structure optimis\u00e9e du champ \u00e9lectrique int\u00e9gr\u00e9 et \u00e0 une couche de contr\u00f4le de contrainte, le champ \u00e9lectrique est uniform\u00e9ment r\u00e9parti, supprimant efficacement les d\u00e9charges partielles. Il n'y a aucun risque de corrosion \u00e9lectrolytique ou de claquage lors d'un fonctionnement \u00e0 long terme, et les performances d'isolation sont stables et fiables.<\/li>\n\n\n\n<li>Les inserts conducteurs en cuivre\/aluminium int\u00e9gr\u00e9s offrent une excellente conductivit\u00e9, une faible r\u00e9sistance de contact et la capacit\u00e9 de supporter le courant nominal correspondant. Ils g\u00e9n\u00e8rent \u00e9galement peu de chaleur lors d'un fonctionnement \u00e0 long terme et poss\u00e8dent une forte r\u00e9sistance \u00e0 la corrosion et \u00e0 l'oxydation.<\/li>\n\n\n\n<li>La surface isolante est trait\u00e9e par un proc\u00e9d\u00e9 sp\u00e9cial, ce qui lui conf\u00e8re une r\u00e9sistivit\u00e9 de surface \u00e9lev\u00e9e et une forte hydrophobicit\u00e9. Cela emp\u00eache efficacement les surtensions de surface caus\u00e9es par la condensation et la salet\u00e9, am\u00e9liorant ainsi la fiabilit\u00e9 de l'isolation dans des environnements difficiles.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Caract\u00e9ristiques structurelles et de s\u00e9curit\u00e9<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La conception de l'interface enfichable conique interne normalis\u00e9e est strictement conforme aux normes GB\/T 12706 et IEC 60840, et est interchangeable avec les douilles isol\u00e9es coniques internes 1#\/2#\/3#, offrant une forte compatibilit\u00e9 et une grande adaptabilit\u00e9 aux diff\u00e9rentes sp\u00e9cifications des interfaces des \u00e9quipements de distribution d'\u00e9nergie.<\/li>\n\n\n\n<li>Gr\u00e2ce \u00e0 sa conception structurelle int\u00e9gr\u00e9e, l'extr\u00e9mit\u00e9 avant pr\u00e9sente une interface conique interne, tandis que l'extr\u00e9mit\u00e9 arri\u00e8re est un terminal de connexion de c\u00e2ble. Lors de l'installation, il peut \u00eatre directement ins\u00e9r\u00e9 dans la douille correspondante sans n\u00e9cessiter d'outils suppl\u00e9mentaires, ce qui rend l'installation sur site pratique et raccourcit consid\u00e9rablement le cycle de construction.<\/li>\n\n\n\n<li>La conception emp\u00eache les erreurs d'insertion et de connexion. La taille de l'interface est adapt\u00e9e de mani\u00e8re unique et ne peut \u00eatre utilis\u00e9e qu'avec des prises des sp\u00e9cifications correspondantes, ce qui emp\u00eache l'utilisation d'accessoires de sp\u00e9cifications diff\u00e9rentes. Elle dispose d'une structure de positionnement et de verrouillage int\u00e9gr\u00e9e pour \u00e9viter le desserrage et la chute apr\u00e8s l'installation.<\/li>\n\n\n\n<li>Avec une structure enti\u00e8rement isol\u00e9e et tactile, et une forte isolation ext\u00e9rieure, le bo\u00eetier ext\u00e9rieur peut \u00eatre touch\u00e9 directement pendant le fonctionnement sans risque de choc \u00e9lectrique, garantissant la s\u00e9curit\u00e9 du personnel de maintenance.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. R\u00e9sistance environnementale et aux intemp\u00e9ries<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Il pr\u00e9sente une excellente r\u00e9sistance aux intemp\u00e9ries et peut s'adapter \u00e0 une large plage de temp\u00e9ratures, de -40\u2103 \u00e0 +90\u2103. L'\u00e9lasticit\u00e9 et les propri\u00e9t\u00e9s isolantes du caoutchouc ne diminuent pas sous les hautes et basses temp\u00e9ratures, et il n'y a aucun risque de fissuration ou de fragilisation. Il convient \u00e0 divers sc\u00e9narios ext\u00e9rieurs et int\u00e9rieurs.<\/li>\n\n\n\n<li>\u00c9tanche \u00e0 l'humidit\u00e9, \u00e0 l'eau, aux taches et aux embruns salins, avec un indice de protection IP67, il peut fonctionner de mani\u00e8re stable pendant longtemps dans des environnements difficiles tels que les conditions humides, poussi\u00e9reuses et d'embruns salins, et ne craint ni la pluie ni la condensation.<\/li>\n\n\n\n<li>Il est r\u00e9sistant au vieillissement, aux rayons ultraviolets et \u00e0 la corrosion par l'ozone, avec une dur\u00e9e de vie de plus de 30 ans. Il ne n\u00e9cessite aucun entretien et r\u00e9duit les co\u00fbts d'exploitation et de maintenance ult\u00e9rieurs.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4. Caract\u00e9ristiques m\u00e9caniques et d'adaptation<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Il poss\u00e8de une r\u00e9sistance m\u00e9canique \u00e9lev\u00e9e, r\u00e9siste aux chocs et aux vibrations, et peut supporter les contraintes m\u00e9caniques lors du transport, de l'installation et de l'exploitation sans risque de d\u00e9formation ou de dommage. Son niveau de r\u00e9sistance sismique atteint le niveau 8.<\/li>\n\n\n\n<li>Disponible en trois tailles : n\u00b01, n\u00b02 et n\u00b03, adapt\u00e9es aux \u00e9quipements de distribution d'\u00e9nergie et aux c\u00e2bles de diff\u00e9rents niveaux de tension et de courant, offrant une grande polyvalence.<\/li>\n\n\n\n<li>La conception modulaire permet un remplacement individuel en mode plug-and-play, permettant la maintenance des accessoires sans coupure de courant, am\u00e9liorant ainsi consid\u00e9rablement l'efficacit\u00e9 op\u00e9rationnelle et r\u00e9duisant les pertes dues aux coupures de courant.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>III. Param\u00e8tres techniques<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Cat\u00e9gories de param\u00e8tres<\/td><td>projet<\/td><td>Indicateurs techniques<\/td><\/tr><tr><td>Param\u00e8tres \u00e9lectriques nominal<\/td><td>Tension nominale du syst\u00e8me (Un)<\/td><td>35 kV<\/td><\/tr><tr><td>&nbsp;<\/td><td>Tension nominale (Ue)<\/td><td>35 kV<\/td><\/tr><tr><td>&nbsp;<\/td><td>Tension de service maximale (Um)<\/td><td>40,5 kV<\/td><\/tr><tr><td>&nbsp;<\/td><td>Fr\u00e9quence nominale (fn)<\/td><td>50Hz\/60Hz<\/td><\/tr><tr><td>&nbsp;<\/td><td>Tension de tenue \u00e0 la fr\u00e9quence industrielle<\/td><td>95 kV\/5 min (essai \u00e0 sec), pas de claquage, pas de d\u00e9charge disruptive<\/td><\/tr><tr><td>&nbsp;<\/td><td>Tension de tenue \u00e0 la foudre<\/td><td>200 kV (valeur de cr\u00eate), pas de claquage, pas de d\u00e9charge disruptive<\/td><\/tr><tr><td>&nbsp;<\/td><td>Quantit\u00e9 de d\u00e9charge partielle<\/td><td>\u226410pC (inf\u00e9rieur \u00e0 1,5U\u2080)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Courant nominal<\/td><td>630A\/1250A (plusieurs sp\u00e9cifications disponibles)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Courant de courte dur\u00e9e admissible<\/td><td>20 kA\/2 s, 25 kA\/2 s, 31,5 kA\/2 s (facultatif)<\/td><\/tr><tr><td>&nbsp;<\/td><td>R\u00e9sistance de contact<\/td><td>\u226450\u03bc\u03a9<\/td><\/tr><tr><td>Param\u00e8tres structurels et mat\u00e9riels<\/td><td>Mati\u00e8re principale<\/td><td>Caoutchouc EPDM (monom\u00e8re d'\u00e9thyl\u00e8ne propyl\u00e8ne di\u00e8ne) (couche isolante), cuivre\/aluminium \u00e9tam\u00e9 (inserts conducteurs)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Niveau de protection<\/td><td>IP67<\/td><\/tr><tr><td>&nbsp;<\/td><td>Interface standard<\/td><td>Interface conique interne, conforme aux normes GB\/T 12706 et IEC 60840.<\/td><\/tr><tr><td>&nbsp;<\/td><td>Sp\u00e9cifications de la s\u00e9rie<\/td><td>1#, 2#, 3# (adapt\u00e9 \u00e0 diff\u00e9rents courants\/sections de c\u00e2ble)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Douille assortie<\/td><td>1#\/2#\/3# Douille isol\u00e9e \u00e0 c\u00f4ne interne<\/td><\/tr><tr><td>Param\u00e8tres environnementaux<\/td><td>Altitude applicable<\/td><td>\u22642000m (Personnalisation disponible pour les hautes altitudes)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Temp\u00e9rature ambiante<\/td><td>-40\u2103\/+90\u2103 (temp\u00e9rature de fonctionnement), -40\u2103\/+70\u2103 (temp\u00e9rature de stockage)<\/td><\/tr><tr><td>&nbsp;<\/td><td>humidit\u00e9 relative<\/td><td>\u2264100 % (sans condensation)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Niveau de r\u00e9sistance sismique<\/td><td>Niveau 8<\/td><\/tr><tr><td>Normes de mise en \u0153uvre<\/td><td>&nbsp;<\/td><td>GB\/T 12706, IEC 60840, GB\/T 11022, DL\/T 404<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IV. Champ d'application<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Niveau de tension applicable<\/strong> : Syst\u00e8me de distribution d'\u00e9nergie haute tension 35kV AC, compatible avec les \u00e9quipements de distribution d'\u00e9nergie ayant une tension de fonctionnement maximale de 40,5kV.<\/li>\n\n\n\n<li><strong>Sc\u00e9narios d'\u00e9quipement applicables<\/strong> :<\/li>\n\n\n\n<li>Les interfaces d'entr\u00e9e et de sortie de c\u00e2ble des \u00e9quipements de distribution d'\u00e9nergie tels que les appareillages de commutation 35 kV, les postes de coupure et les postes de transformation pr\u00e9fabriqu\u00e9s sont utilis\u00e9es conjointement avec les douilles isol\u00e9es \u00e0 c\u00f4ne int\u00e9rieur #1\/#2\/#3 ;<\/li>\n\n\n\n<li>Lignes de c\u00e2bles 35 kV pour r\u00e9seaux de distribution d'\u00e9nergie urbains, syst\u00e8mes de distribution d'\u00e9nergie pour entreprises industrielles et mini\u00e8res, et interfaces d'\u00e9quipement de distribution d'\u00e9nergie pour postes de rel\u00e8vement de nouvelles \u00e9nergies (photovolta\u00efque\/\u00e9olien) ;<\/li>\n\n\n\n<li>Installation de terminaisons de c\u00e2bles pour \u00e9quipements de distribution d'\u00e9nergie haute tension dans divers sc\u00e9narios tels que les salles de distribution d'\u00e9nergie int\u00e9rieures\/ext\u00e9rieures, les tunnels de services publics souterrains et les tunnels de c\u00e2bles.<\/li>\n\n\n\n<li><strong>Fonction et application<\/strong> Pour r\u00e9aliser l'isolation, la connexion conductrice et la protection d'\u00e9tanch\u00e9it\u00e9 des c\u00e2bles de 35 kV et des \u00e9quipements de distribution d'\u00e9nergie, sans n\u00e9cessiter de traitement de gaz ou d'huile isolante sur site, et pour fournir une solution de terminal de c\u00e2ble d\u00e9tachable s\u00fbre, fiable et facile \u00e0 installer pour les syst\u00e8mes de distribution d'\u00e9nergie haute tension.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>V. Conditions d'utilisation<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Conditions normales de fonctionnement<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Altitude : \u22642000m ;<\/li>\n\n\n\n<li>Temp\u00e9rature ambiante : -40\u2103~+90\u2103 ; la temp\u00e9rature de fonctionnement de l'\u00e9quipement est conforme aux normes pertinentes.<\/li>\n\n\n\n<li>Humidit\u00e9 relative : \u2264100 % (sans condensation) ;<\/li>\n\n\n\n<li>Conditions environnementales : pas de gaz corrosifs, pas de milieux inflammables ou explosifs, pas de vibrations ou de chocs importants.<\/li>\n\n\n\n<li>M\u00e9thode d'installation : Ins\u00e9rer directement dans la douille isol\u00e9e \u00e0 c\u00f4ne int\u00e9rieur correspondante. L'installation horizontale ou verticale est acceptable. L'espace d'installation doit r\u00e9pondre aux exigences d'insertion et de retrait.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Conditions d'utilisation sp\u00e9ciales (personnalisation requise)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>L'altitude d\u00e9passe 2000m.<\/li>\n\n\n\n<li>La temp\u00e9rature ambiante d\u00e9passe la plage de -40\u2103 \u00e0 +90\u2103.<\/li>\n\n\n\n<li>Environnements s\u00e9v\u00e8rement pollu\u00e9s, soumis aux embruns salins et chimiquement corrosifs ;<\/li>\n\n\n\n<li>Conditions de fortes vibrations et de chocs importants.<\/li>\n\n\n\n<li>Sections de c\u00e2bles non standard et sp\u00e9cifications d'interface sp\u00e9ciales.<\/li>\n\n\n\n<li>Exigences de mise \u00e0 la terre sp\u00e9ciales et niveaux de pollution \u00e9lev\u00e9s.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VI. Installation et entretien<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Exigences d'installation<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Avant l'installation, inspectez l'aspect du produit pour d\u00e9tecter fissures, dommages, bulles et surfaces d'isolation intactes ; v\u00e9rifiez que les inserts conducteurs sont intacts, exempts de rouille et de d\u00e9formation.<\/li>\n\n\n\n<li>Nettoyez la paroi int\u00e9rieure de la douille isol\u00e9e \u00e0 c\u00f4ne int\u00e9rieur correspondante et la surface de l'interface du terminal pour \u00e9liminer l'huile, la poussi\u00e8re et les corps \u00e9trangers, et assurez-vous que l'interface est s\u00e8che et propre.<\/li>\n\n\n\n<li>Appliquez une graisse de silicone lubrifiante d\u00e9di\u00e9e uniform\u00e9ment sur la paroi ext\u00e9rieure de l'interface du terminal pour \u00e9viter d'endommager la couche isolante pendant l'installation.<\/li>\n\n\n\n<li>Ins\u00e9rez lentement le terminal dans la prise correspondante pour vous assurer qu'il est bien en place, verrouillez le dispositif de positionnement anti-d\u00e9gagement et v\u00e9rifiez qu'il n'y a aucun jeu ni inclinaison apr\u00e8s l'installation.<\/li>\n\n\n\n<li>Apr\u00e8s l'installation, des tests de r\u00e9sistance d'isolement et de tenue en tension \u00e0 fr\u00e9quence industrielle sont effectu\u00e9s. Ce n'est qu'apr\u00e8s avoir r\u00e9ussi ces tests que l'\u00e9quipement peut \u00eatre mis en service.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Exigences de maintenance<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Inspectez r\u00e9guli\u00e8rement l'aspect du terminal pour vous assurer qu'il n'y a pas de fissures, de marques de d\u00e9charge ou d'accumulation de salet\u00e9, que la connexion \u00e0 la prise est s\u00fbre et non l\u00e2che, et que les joints ne sont pas vieillis ou endommag\u00e9s.<\/li>\n\n\n\n<li>Testez r\u00e9guli\u00e8rement la r\u00e9sistance d'isolement pour vous assurer que les performances r\u00e9pondent aux exigences et pour d\u00e9tecter les d\u00e9fauts potentiels en temps voulu.<\/li>\n\n\n\n<li>Nettoyez la surface du terminal pour enlever la poussi\u00e8re et la salet\u00e9, gardez la surface isolante s\u00e8che et propre, et \u00e9vitez la corrosion par l'huile et les produits chimiques.<\/li>\n\n\n\n<li>En cas d'anomalies telles que fissures, dommages, d\u00e9charges ou surchauffe au niveau du terminal ou de sa prise, l'utilisation doit cesser imm\u00e9diatement et il doit \u00eatre remplac\u00e9. L'utilisation avec des d\u00e9fauts est strictement interdite.<\/li>\n\n\n\n<li>Des outils isol\u00e9s sp\u00e9ciaux doivent \u00eatre utilis\u00e9s pour brancher et d\u00e9brancher les bornes. Il est strictement interdit de manipuler des bornes sous tension \u00e0 mains nues. Les r\u00e9glementations de s\u00e9curit\u00e9 de la distribution d'\u00e9nergie doivent \u00eatre strictement respect\u00e9es pendant l'op\u00e9ration.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VII. Pr\u00e9cautions<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Le produit doit \u00eatre install\u00e9, d\u00e9bogu\u00e9 et entretenu par du personnel d'\u00e9lectricit\u00e9 professionnel poss\u00e9dant des qualifications en construction de distribution d'\u00e9nergie haute tension. L'utilisation par du personnel non professionnel est strictement interdite.<\/li>\n\n\n\n<li>Le produit doit \u00eatre utilis\u00e9 avec une douille \u00e0 c\u00f4ne int\u00e9rieur isol\u00e9e de sp\u00e9cification correspondante. Il est strictement interdit d'utiliser des douilles de niveaux de tension ou de sp\u00e9cifications diff\u00e9rentes, sous peine de provoquer une d\u00e9faillance d'isolation et des accidents de s\u00e9curit\u00e9.<\/li>\n\n\n\n<li>Les terminaux ne doivent pas \u00eatre d\u00e9mont\u00e9s ou modifi\u00e9s sans autorisation, faute de quoi la garantie et la garantie de s\u00e9curit\u00e9 seront perdues. Il est strictement interdit d'utiliser des outils non sp\u00e9cialis\u00e9s pour les installer ou les d\u00e9monter de force.<\/li>\n\n\n\n<li>Lors de l'installation, il est strictement interdit d'endommager la surface isolante. La graisse de silicone lubrifiante doit \u00eatre appliqu\u00e9e uniform\u00e9ment afin de ne pas affecter les performances d'isolation et l'effet d'\u00e9tanch\u00e9it\u00e9.<\/li>\n\n\n\n<li>Lors du stockage, il doit \u00eatre plac\u00e9 dans un environnement sec, ventil\u00e9 et frais, en \u00e9vitant la lumi\u00e8re directe du soleil, les temp\u00e9ratures \u00e9lev\u00e9es, l'humidit\u00e9 et la compression. Il est strictement interdit de le mettre en contact avec des objets pointus susceptibles d'endommager la couche isolante.<\/li>\n\n\n\n<li>Lors du branchement ou du d\u00e9branchement de terminaux sous tension, il est essentiel de respecter strictement les r\u00e9glementations de s\u00e9curit\u00e9 de la distribution d'\u00e9nergie, de prendre les pr\u00e9cautions de s\u00e9curit\u00e9 appropri\u00e9es et d'interdire strictement toute op\u00e9ration non autoris\u00e9e.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VIII. Description du mod\u00e8le<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Identification du mod\u00e8le<\/td><td>sens<\/td><\/tr><tr><td>JY<\/td><td>Code de la s\u00e9rie de produits<\/td><\/tr><tr><td>Nouvelle-Z\u00e9lande<\/td><td>Code de la s\u00e9rie de bornes enfichables \u00e0 c\u00f4ne interne<\/td><\/tr><tr><td>35 (40.5)<\/td><td>Tensions nominales du syst\u00e8me applicables : tension nominale 35 kV, tension de fonctionnement maximale 40,5 kV.<\/td><\/tr><tr><td>\u25a1<\/td><td>S\u00e9rie de sp\u00e9cifications (1#\/2#\/3#, adapt\u00e9e \u00e0 diff\u00e9rents calibres de courant\/section de c\u00e2ble)<\/td><\/tr><tr><td>Borne \u00e0 c\u00f4ne int\u00e9rieur 35 kV<\/td><td>Terminaison de c\u00e2ble interne \u00e0 c\u00f4ne enfichable 35 kV, qui peut \u00eatre directement branch\u00e9e et install\u00e9e avec la douille interne \u00e0 c\u00f4ne correspondante.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IX. Normes de mise en \u0153uvre et certification<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Norme internationale : CEI 60840 \u00ab M\u00e9thodes d'essai et exigences pour les c\u00e2bles d'\u00e9nergie isol\u00e9s extrud\u00e9s et leurs accessoires pour des tensions assign\u00e9es de 30 kV et au-dessus (Um = 36 kV) jusqu'\u00e0 150 kV (Um = 170 kV) \u00bb ;<\/li>\n\n\n\n<li>Normes nationales : GB\/T 12706 \u00ab C\u00e2bles d'\u00e9nergie isol\u00e9s extrud\u00e9s et leurs accessoires pour des tensions nominales de 1 kV (Um=1,2 kV) \u00e0 35 kV (Um=40,5 kV) \u00bb, GB\/T 11022 \u00ab Exigences techniques communes pour les normes de jeux de barres et d'appareillage de commutation haute tension \u00bb, DL\/T 404 \u00ab Jeux de barres et appareillage de commutation sous enveloppe m\u00e9tallique pour courant alternatif de 3,6 kV \u00e0 40,5 kV \u00bb ;<\/li>\n\n\n\n<li>Le produit a pass\u00e9 le test de type du Centre national de surveillance et d'inspection de la qualit\u00e9 des appareils \u00e9lectriques haute tension et est conforme aux normes nationales de s\u00e9curit\u00e9 \u00e9lectrique.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>10. Service apr\u00e8s-vente<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>P\u00e9riode de garantie du produit : 18 mois \u00e0 compter de la date de fabrication, ou 12 mois \u00e0 compter de la date de mise en service (le premier terme \u00e9chu).<\/li>\n\n\n\n<li>Pendant la p\u00e9riode de garantie, les produits seront r\u00e9par\u00e9s ou remplac\u00e9s gratuitement en cas de probl\u00e8mes de qualit\u00e9.<\/li>\n\n\n\n<li>Nous fournissons un support technique, des conseils d'installation et des services personnalis\u00e9s (adaptation \u00e0 des sp\u00e9cifications et conditions de travail sp\u00e9ciales).<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Description du document<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les param\u00e8tres techniques de ce manuel sont bas\u00e9s sur des conditions de fonctionnement standard. Les conditions de fonctionnement sp\u00e9ciales doivent \u00eatre personnalis\u00e9es en fonction des besoins r\u00e9els. Les sp\u00e9cifications finales seront soumises \u00e0 l'accord technique du produit et au rapport d'essai de type.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Annexe : Sch\u00e9ma de pr\u00e9sentation du produit<\/strong><strong><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"299\" height=\"300\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-NZ-3540.5-35kV-inner-cone-plug-in-terminal-1.png\" alt=\"JY-NZ-3540.5-35kV-douille int\u00e9rieure\" class=\"wp-image-383\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-NZ-3540.5-35kV-inner-cone-plug-in-terminal-1.png 299w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-NZ-3540.5-35kV-inner-cone-plug-in-terminal-1-150x150.png 150w\" sizes=\"(max-width: 299px) 100vw, 299px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>I. Product Overview The JY NZ-35 (40.5)-\u25a1 35kV inner cone plug-in terminal is a detachable cable terminal specifically designed for [&hellip;]<\/p>\n","protected":false},"featured_media":383,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[12],"class_list":["post-378","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-inner-cone-series"],"acf":{"products_imagines":[381,382,383],"short_describe":"<p><strong>replacement<\/strong> (1) 35kV inner cone socket, (2) copper contact finger, (3) 35kV inner cone plug-in terminal, (4) inner cone socket mounting plate, (5) inner cone protective shell, (6) semiconductive tape with steps, (7) protective sleeve, (8) power cable<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/products\/378","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/383"},{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/382"},{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/381"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/383"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media?parent=378"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/product_category?post=378"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}