{"id":542,"date":"2026-01-26T01:29:31","date_gmt":"2026-01-26T01:29:31","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=542"},"modified":"2026-09-10T05:48:49","modified_gmt":"2026-09-10T05:48:49","slug":"fully-cold-shrink-three-core-indoor-terminal-3","status":"publish","type":"products","link":"https:\/\/yieou.com\/fr\/product\/fully-cold-shrink-three-core-indoor-terminal-3\/","title":{"rendered":"8.7\/15kV Fully Cold-Shrink Three-Core Indoor Terminal"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>I. Aper\u00e7u du produit<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/fr\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">Le terminal int\u00e9rieur 8,7\/15 kV \u00e0 trois conducteurs enti\u00e8rement r\u00e9tractable \u00e0 froid<\/a> est un accessoire r\u00e9tractable \u00e0 froid sp\u00e9cialement con\u00e7u pour les terminaisons int\u00e9rieures de c\u00e2bles d'alimentation triphas\u00e9s de 8,7\/15 kV <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_cable\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_cable\" target=\"_blank\" rel=\"noopener\">c\u00e2bles<\/a>Fabriqu\u00e9 en caoutchouc de silicone, il utilise son propre r\u00e9tr\u00e9cissement \u00e9lastique pour assurer l'isolation, l'\u00e9tanch\u00e9it\u00e9 et la protection du terminal de c\u00e2ble. Aucun outil de chauffage n'est requis et l'installation est pratique. Il est largement utilis\u00e9 dans les sc\u00e9narios de terminaux int\u00e9rieurs pour les c\u00e2bles d'alimentation 10 kV afin d'assurer le fonctionnement s\u00fbr et stable du terminal de c\u00e2ble.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II. Caract\u00e9ristiques du produit<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Isolation et propri\u00e9t\u00e9s \u00e9lectriques<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fabriqu\u00e9 en caoutchouc de silicone de haute qualit\u00e9, il poss\u00e8de d'excellentes propri\u00e9t\u00e9s d'isolation et peut supporter efficacement la tension de service du syst\u00e8me 8,7\/15 kV. Ses performances de tenue en tension \u00e0 fr\u00e9quence industrielle et en tension de choc r\u00e9pondent aux normes industrielles, garantissant la s\u00e9curit\u00e9 d'isolation des terminaisons de c\u00e2bles.<\/li>\n\n\n\n<li>Gr\u00e2ce \u00e0 sa propre structure de contr\u00f4le de contrainte, il peut distribuer efficacement et uniform\u00e9ment le champ \u00e9lectrique \u00e0 l'extr\u00e9mit\u00e9 du c\u00e2ble, \u00e9viter les d\u00e9charges partielles caus\u00e9es par la concentration du champ \u00e9lectrique et am\u00e9liorer la fiabilit\u00e9 op\u00e9rationnelle \u00e0 long terme de l'extr\u00e9mit\u00e9.<\/li>\n\n\n\n<li>Apr\u00e8s r\u00e9tr\u00e9cissement \u00e0 froid et r\u00e9traction, il peut s'ajuster \u00e9troitement au corps du c\u00e2ble pour former une structure d'\u00e9tanch\u00e9it\u00e9 continue et fiable, emp\u00eachant l'humidit\u00e9, la poussi\u00e8re et l'huile de p\u00e9n\u00e9trer dans le terminal du c\u00e2ble. Il offre d'excellentes performances d'\u00e9tanch\u00e9it\u00e9 \u00e0 l'humidit\u00e9, d'imperm\u00e9abilit\u00e9 et d'anti-salissure, ainsi qu'une protection IP68.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Caract\u00e9ristiques d'installation et de construction<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Gr\u00e2ce \u00e0 sa conception enti\u00e8rement r\u00e9tractable, il ne n\u00e9cessite aucune flamme nue ni aucun outil de chauffage. L'installation s'effectue par la r\u00e9traction \u00e9lastique du diam\u00e8tre pr\u00e9-expans\u00e9, rendant le processus d'installation s\u00fbr et pratique, sans risque d'incendie. Il convient aux sc\u00e9narios de construction sp\u00e9ciaux tels que les applications int\u00e9rieures et antid\u00e9flagrantes.<\/li>\n\n\n\n<li>L'ensemble complet comprend tous les accessoires n\u00e9cessaires \u00e0 la fabrication des bornes (tubes isolants, tubes de contrainte, mastic, outils d'installation, etc.), \u00e9liminant ainsi le besoin de pi\u00e8ces suppl\u00e9mentaires pendant la construction, raccourcissant consid\u00e9rablement le temps de fabrication des bornes et r\u00e9duisant les co\u00fbts de construction.<\/li>\n\n\n\n<li>Apr\u00e8s l'installation, le terminal pr\u00e9sente un aspect net et esth\u00e9tique, sans les probl\u00e8mes de r\u00e9tr\u00e9cissement in\u00e9gal, de bulles ou de d\u00e9formation courants avec les produits thermor\u00e9tractables. Il pr\u00e9sente une bonne constance et facilite la maintenance et l'inspection ult\u00e9rieures.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. R\u00e9sistance environnementale et aux intemp\u00e9ries<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Gr\u00e2ce \u00e0 son excellente r\u00e9sistance aux intemp\u00e9ries, il peut s'adapter \u00e0 une large plage de temp\u00e9ratures allant de -40\u2103 \u00e0 +90\u2103. L'\u00e9lasticit\u00e9 et les propri\u00e9t\u00e9s isolantes du caoutchouc de silicone ne diminuent pas sous les hautes et basses temp\u00e9ratures, et il n'y a aucun risque de fissuration, de fragilisation ou de d\u00e9formation. Il convient \u00e0 une vari\u00e9t\u00e9 de sc\u00e9narios int\u00e9rieurs.<\/li>\n\n\n\n<li>Il r\u00e9siste au vieillissement, aux rayons ultraviolets et \u00e0 la corrosion par l'ozone, avec une dur\u00e9e de vie de plus de 20 ans. Il ne n\u00e9cessite aucun entretien et r\u00e9duit les co\u00fbts d'exploitation et de maintenance ult\u00e9rieurs.<\/li>\n\n\n\n<li>Il r\u00e9siste \u00e0 la corrosion chimique, peut s'adapter aux environnements humides et poussi\u00e9reux, ne pr\u00e9sente aucun risque de corrosion ou de d\u00e9gradation, et convient aux entreprises industrielles et mini\u00e8res, aux immeubles commerciaux et \u00e0 d'autres sc\u00e9narios.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Caract\u00e9ristiques m\u00e9caniques et d'adaptation<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Les mat\u00e9riaux en caoutchouc de silicone ont une r\u00e9sistance m\u00e9canique \u00e9lev\u00e9e, sont r\u00e9sistants \u00e0 la d\u00e9chirure et \u00e0 la traction, et peuvent supporter les contraintes m\u00e9caniques pendant la construction et l'exploitation sans risque de rupture ou de fissuration.<\/li>\n\n\n\n<li>Il est compatible avec les c\u00e2bles d'alimentation tripolaires 8,7\/15 kV, couvrant les sp\u00e9cifications de section courantes, et poss\u00e8de une grande polyvalence, ce qui le rend adapt\u00e9 aux sc\u00e9narios d'installation tels que les armoires de commutation int\u00e9rieures, les salles de distribution d'\u00e9nergie et les sous-stations pr\u00e9fabriqu\u00e9es.<\/li>\n\n\n\n<li>Le terminal a une structure compacte et une petite taille, ce qui le rend adapt\u00e9 \u00e0 une installation dans des espaces int\u00e9rieurs restreints sans aucune limitation d'espace.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>III. Param\u00e8tres techniques<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Cat\u00e9gories de param\u00e8tres<\/td><td>projet<\/td><td>Indicateurs techniques<\/td><\/tr><tr><td>Param\u00e8tres \u00e9lectriques<\/td><td>Tension syst\u00e8me applicable<\/td><td>8,7\/15 kV CA<\/td><\/tr><tr><td>&nbsp;<\/td><td>Tension nominale<\/td><td>15 kV<\/td><\/tr><tr><td>&nbsp;<\/td><td>Tension de tenue \u00e0 la fr\u00e9quence industrielle (5 min)<\/td><td>42 kV, sans claquage<\/td><\/tr><tr><td>&nbsp;<\/td><td>R\u00e9sistance aux chocs (pic)<\/td><td>95 kV, sans claquage<\/td><\/tr><tr><td>&nbsp;<\/td><td>R\u00e9sistance d'isolement<\/td><td>\u22651000M\u03a9<\/td><\/tr><tr><td>&nbsp;<\/td><td>Quantit\u00e9 de d\u00e9charge partielle<\/td><td>\u22645pC (\u00e0 1,5 fois la tension nominale)<\/td><\/tr><tr><td>Param\u00e8tres structurels et mat\u00e9riels<\/td><td>Mati\u00e8re principale<\/td><td>caoutchouc de silicone<\/td><\/tr><tr><td>&nbsp;<\/td><td>Nombre de conducteurs de c\u00e2ble applicables<\/td><td>Trois conducteurs<\/td><\/tr><tr><td>&nbsp;<\/td><td>Section de c\u00e2ble applicable<\/td><td>25mm\u00b2~400mm\u00b2 (s\u00e9lectionner selon les sp\u00e9cifications)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Niveau de protection<\/td><td>IP68<\/td><\/tr><tr><td>&nbsp;<\/td><td>Forme structurelle<\/td><td>Terminal int\u00e9rieur enti\u00e8rement r\u00e9frig\u00e9r\u00e9 (ensemble complet)<\/td><\/tr><tr><td>Param\u00e8tres environnementaux<\/td><td>Altitude applicable<\/td><td>\u22642000m (Personnalisation disponible pour les hautes altitudes)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Temp\u00e9rature ambiante<\/td><td>-40\u2103\/+90\u2103 (temp\u00e9rature de fonctionnement), -40\u2103\/+70\u2103 (temp\u00e9rature de stockage)<\/td><\/tr><tr><td>&nbsp;<\/td><td>humidit\u00e9 relative<\/td><td>\u2264100 % (sans condensation)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Niveau de r\u00e9sistance sismique<\/td><td>Niveau 8<\/td><\/tr><tr><td>Normes de mise en \u0153uvre<\/td><td>&nbsp;<\/td><td>GB\/T 12706 \u00ab C\u00e2bles d'\u00e9nergie isol\u00e9s extrud\u00e9s et leurs accessoires pour tensions nominales de 1 kV (Um=1,2 kV) \u00e0 35 kV (Um=40,5 kV) \u00bb et IEC 60840 \u00ab M\u00e9thodes d'essai et exigences pour les c\u00e2bles d'\u00e9nergie isol\u00e9s extrud\u00e9s et leurs accessoires pour tensions nominales de 30 kV (Um=36 kV) et sup\u00e9rieures \u00e0 150 kV (Um=170 kV) \u00bb.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IV. Liste des composants du produit<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Num\u00e9ro de s\u00e9rie<\/td><td>nom<\/td><td>utiliser<\/td><\/tr><tr><td>01<\/td><td>Corps isolant de terminal r\u00e9tractable \u00e0 froid<\/td><td>Isolation et protection principales pour les bornes de c\u00e2ble<\/td><\/tr><tr><td>02<\/td><td>Tube isolant r\u00e9tractable \u00e0 froid<\/td><td>Protection de la couche d'isolation de phase du c\u00e2ble et isolation<\/td><\/tr><tr><td>03<\/td><td>Tube thermor\u00e9tractable \u00e0 froid<\/td><td>\u00c9tanch\u00e9it\u00e9 et imperm\u00e9abilisation des terminaisons de c\u00e2bles<\/td><\/tr><tr><td>04<\/td><td>Gants de branchement \u00e0 trois conducteurs<\/td><td>Isolation et \u00e9tanch\u00e9it\u00e9 au niveau du branchement triphas\u00e9 du c\u00e2ble<\/td><\/tr><tr><td>05\/06<\/td><td>Bo\u00eete d'accessoires d'installation (colle d'\u00e9tanch\u00e9it\u00e9\/agent de nettoyage)<\/td><td>Nettoyer la surface du c\u00e2ble et sceller l'interface du terminal<\/td><\/tr><tr><td>07<\/td><td>Anneau de pression en m\u00e9tal<\/td><td>Borne et corps de c\u00e2ble fixes<\/td><\/tr><tr><td>08<\/td><td>Bande de cuivre tress\u00e9e<\/td><td>Connexion de mise \u00e0 la terre du terminal de c\u00e2ble<\/td><\/tr><tr><td>09<\/td><td>Ruban isolant\/Ruban semi-conducteur<\/td><td>Contr\u00f4le du champ \u00e9lectrique et assistance \u00e0 l'isolation de terminal de c\u00e2ble<\/td><\/tr><tr><td>10<\/td><td>Instructions d'installation\/carte de processus<\/td><td>Fabrication et construction de terminaux : directives<\/td><\/tr><tr><td>11<\/td><td>Papier de verre\/Chiffon de nettoyage<\/td><td>Meulage et nettoyage de surface de c\u00e2ble<\/td><\/tr><tr><td>12<\/td><td>Ruban isolant \/ Ruban semi-conducteur<\/td><td>Isolation de l'interface terminale et contr\u00f4le du champ \u00e9lectrique<\/td><\/tr><tr><td>13<\/td><td>Gants\/lunettes de protection<\/td><td>Protection de la s\u00e9curit\u00e9 sur les chantiers<\/td><\/tr><tr><td>14<\/td><td>Outils d'installation (m\u00e8tre ruban, cutter, pince \u00e0 d\u00e9nuder, etc.)<\/td><td>D\u00e9nudage de c\u00e2ble et pose de cosses<\/td><\/tr><tr><td>15<\/td><td>Certificat de qualit\u00e9\/Rapport d'inspection<\/td><td>Documents de certification de la qualit\u00e9 des produits<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>V. Champ d'application<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Niveau de tension applicable<\/strong> : Syst\u00e8me de c\u00e2ble d'alimentation AC 8,7\/15 kV.<\/li>\n\n\n\n<li><strong>Sc\u00e9narios applicables<\/strong> :<\/li>\n\n\n\n<li>Fabrication de terminaisons int\u00e9rieures pour c\u00e2bles d'alimentation tripolaires 10 kV ;<\/li>\n\n\n\n<li>Bornes de c\u00e2bles pour applications int\u00e9rieures telles que les salles de distribution d'\u00e9nergie, les armoires de commutation, les sous-stations pr\u00e9fabriqu\u00e9es, les entreprises industrielles et mini\u00e8res, et les b\u00e2timents commerciaux ;<\/li>\n\n\n\n<li>Bornes de c\u00e2ble pour sc\u00e9narios de construction sp\u00e9ciaux tels que les environnements antid\u00e9flagrants et ininflammables ;<\/li>\n\n\n\n<li>Bornes de c\u00e2ble int\u00e9rieures dans des environnements humides et poussi\u00e9reux.<\/li>\n\n\n\n<li><strong>Fonction et application<\/strong> : Assure l'isolation, le contr\u00f4le du champ \u00e9lectrique, l'\u00e9tanch\u00e9it\u00e9 et la protection des terminaisons int\u00e9rieures des c\u00e2bles d'alimentation tripolaires 8,7\/15 kV, emp\u00eache l'humidit\u00e9 et la poussi\u00e8re de p\u00e9n\u00e9trer dans les terminaisons du c\u00e2ble, assure une r\u00e9partition uniforme du champ \u00e9lectrique aux terminaisons, garantit un fonctionnement s\u00fbr et stable des terminaisons du c\u00e2ble, et \u00e9vite les fuites, les courts-circuits, les d\u00e9clenchements intempestifs dus \u00e0 une d\u00e9faillance de l'isolation de la terminaison, \u00e0 une concentration du champ \u00e9lectrique, \u00e0 une mauvaise \u00e9tanch\u00e9it\u00e9.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VI. Conditions d'utilisation<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Conditions normales de fonctionnement<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Altitude : \u22642000m ;<\/li>\n\n\n\n<li>Temp\u00e9rature ambiante : -40\u2103 \u00e0 +90\u2103 ; la temp\u00e9rature de fonctionnement du c\u00e2ble ne doit pas d\u00e9passer la temp\u00e9rature de fonctionnement admissible \u00e0 long terme du conducteur.<\/li>\n\n\n\n<li>Humidit\u00e9 relative : \u2264100 % (sans condensation) ;<\/li>\n\n\n\n<li>Conditions environnementales : pas de gaz corrosifs, pas de milieux inflammables ou explosifs, pas de vibrations ou de chocs importants.<\/li>\n\n\n\n<li>M\u00e9thode d'installation : installation par r\u00e9treint \u00e0 froid. Il suffit de retirer le fil de support central pour terminer le r\u00e9treint. L'espace d'installation doit respecter les exigences du rayon de courbure du terminal de c\u00e2ble.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Conditions d'utilisation sp\u00e9ciales (personnalisation requise)<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>L'altitude d\u00e9passe 2000m.<\/li>\n\n\n\n<li>La temp\u00e9rature ambiante d\u00e9passe la plage de -40\u2103 \u00e0 +90\u2103.<\/li>\n\n\n\n<li>Environnements s\u00e9v\u00e8rement pollu\u00e9s, soumis aux embruns salins et chimiquement corrosifs ;<\/li>\n\n\n\n<li>Conditions de fortes vibrations et de chocs importants.<\/li>\n\n\n\n<li>Sc\u00e9narios n\u00e9cessitant des sections de c\u00e2ble non standard et des niveaux de protection sp\u00e9ciaux.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VII. Installation et entretien<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Exigences d'installation<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Avant l'installation, v\u00e9rifiez l'aspect du produit. Les bornes en caoutchouc de silicone doivent \u00eatre exemptes de fissures, de dommages et de bulles. Les fils du noyau de support doivent \u00eatre intacts et exempts de d\u00e9formation. Tous les accessoires doivent \u00eatre complets et non endommag\u00e9s.<\/li>\n\n\n\n<li>Coupez le c\u00e2ble conform\u00e9ment au processus de fabrication des terminaux de c\u00e2ble. La longueur de coupe doit respecter les sp\u00e9cifications du terminal. \u00c9vitez d'endommager la couche d'isolation du c\u00e2ble pendant le processus de coupe. Apr\u00e8s la coupe, utilisez un agent de nettoyage pour nettoyer la surface du c\u00e2ble afin d'\u00e9liminer l'huile, la poussi\u00e8re et les r\u00e9sidus de la couche semi-conductrice, et assurez-vous que la surface est s\u00e8che et propre.<\/li>\n\n\n\n<li>Installez le manchon de branche r\u00e9tractable \u00e0 froid, le tube isolant, le tube de contrainte et le corps de borne en s\u00e9quence. Apr\u00e8s avoir ajust\u00e9 la position, retirez lentement le fil du noyau de support pour que la borne se r\u00e9tracte uniform\u00e9ment, en veillant \u00e0 ce que chaque composant s'ajuste parfaitement au corps du c\u00e2ble sans aucun d\u00e9calage, bulle d'air ou pli.<\/li>\n\n\n\n<li>Apr\u00e8s l'installation, connectez la bande de cuivre de mise \u00e0 la terre conform\u00e9ment aux exigences du processus, v\u00e9rifiez que la connexion de mise \u00e0 la terre du terminal est fiable et confirmez que le terminal se r\u00e9tracte uniform\u00e9ment, sans dommages ni espaces, et que l'installation est termin\u00e9e.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Exigences de maintenance<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Inspectez r\u00e9guli\u00e8rement l'apparence du terminal. Le terminal en caoutchouc de silicone doit \u00eatre exempt de fissures, de dommages, de marques de d\u00e9charge et d'accumulation de salet\u00e9. Le terminal doit s'ajuster fermement au c\u00e2ble, sans jeu ni espace.<\/li>\n\n\n\n<li>Testez r\u00e9guli\u00e8rement la r\u00e9sistance d'isolement et la d\u00e9charge partielle du terminal pour vous assurer que les performances r\u00e9pondent aux exigences et pour identifier rapidement les dangers potentiels d'isolement.<\/li>\n\n\n\n<li>Nettoyez la surface du terminal pour enlever la poussi\u00e8re et la salet\u00e9, gardez la surface du terminal s\u00e8che et propre, et \u00e9vitez la corrosion par l'huile et les produits chimiques.<\/li>\n\n\n\n<li>Si une borne pr\u00e9sente des anomalies telles que des fissures, des dommages, une d\u00e9charge ou une r\u00e9sistance d'isolement excessive, elle doit \u00eatre remplac\u00e9e rapidement. L'utilisation avec des d\u00e9fauts est strictement interdite.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VIII. Pr\u00e9cautions<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Le produit doit \u00eatre install\u00e9, d\u00e9bogu\u00e9 et entretenu par du personnel d'\u00e9lectricit\u00e9 professionnel qualifi\u00e9 dans la fabrication de terminaisons de c\u00e2bles haute tension. L'utilisation par du personnel non professionnel est strictement interdite.<\/li>\n\n\n\n<li>Le produit doit \u00eatre utilis\u00e9 avec des c\u00e2bles d'alimentation de 8,7\/15 kV de section transversale et de nombre de conducteurs correspondants. Il est strictement interdit d'utiliser des c\u00e2bles de sp\u00e9cifications diff\u00e9rentes, sous peine de provoquer une d\u00e9faillance d'isolation et d'\u00e9tanch\u00e9it\u00e9 et de causer des accidents de s\u00e9curit\u00e9.<\/li>\n\n\n\n<li>Le produit ne doit pas \u00eatre d\u00e9mont\u00e9 ou modifi\u00e9 sans autorisation, faute de quoi la garantie et la garantie de s\u00e9curit\u00e9 seront perdues. Il est strictement interdit d'\u00e9tirer ou de couper l'extr\u00e9mit\u00e9 de force afin d'\u00e9viter d'endommager le mat\u00e9riau en caoutchouc de silicone.<\/li>\n\n\n\n<li>Lors de l'installation, les c\u00e2bles doivent \u00eatre d\u00e9nud\u00e9s et les composants install\u00e9s conform\u00e9ment aux exigences du processus afin d'\u00e9viter d'endommager la couche d'isolation du c\u00e2ble. Les fils du noyau de support doivent \u00eatre tir\u00e9s lentement pour \u00e9viter une contraction in\u00e9gale ou un d\u00e9salignement aux bornes.<\/li>\n\n\n\n<li>Lors du stockage, il doit \u00eatre plac\u00e9 dans un environnement sec, ventil\u00e9 et frais, en \u00e9vitant la lumi\u00e8re directe du soleil, les temp\u00e9ratures \u00e9lev\u00e9es, l'humidit\u00e9 et la compression. Il est strictement interdit de le mettre en contact avec des objets pointus susceptibles d'endommager le terminal. Le fil de noyau de support doit \u00eatre maintenu intact pour \u00e9viter toute d\u00e9formation.<\/li>\n\n\n\n<li>En cours d'utilisation, l'\u00e9tat du terminal doit \u00eatre v\u00e9rifi\u00e9 r\u00e9guli\u00e8rement pour \u00e9viter toute pression ext\u00e9rieure ou collision, et pour pr\u00e9venir les dommages au terminal ou une d\u00e9faillance d'\u00e9tanch\u00e9it\u00e9.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IX. Description du mod\u00e8le<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Identification du mod\u00e8le<\/td><td>sens<\/td><\/tr><tr><td>8,7\/15 kV<\/td><td>Tension nominale du syst\u00e8me applicable : c\u00e2ble d'alimentation 8,7\/15 kV<\/td><\/tr><tr><td>R\u00e9tr\u00e9cissement \u00e0 froid total<\/td><td>Marquages de m\u00e9thode d'installation, conception enti\u00e8rement r\u00e9tractable.<\/td><\/tr><tr><td>Trois conducteurs<\/td><td>Compatible avec les marquages du nombre de conducteurs, c\u00e2ble \u00e0 trois conducteurs<\/td><\/tr><tr><td>Int\u00e9rieur<\/td><td>Identification de la sc\u00e8ne d'installation, terminal int\u00e9rieur<\/td><\/tr><tr><td>XXmm\u00b2<\/td><td>Compatible avec les marquages de section de c\u00e2ble, tels que 70 mm\u00b2, 120 mm\u00b2, 240 mm\u00b2, 400 mm\u00b2, etc.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">X<strong>Normes de mise en \u0153uvre et certification<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Norme internationale : CEI 60840 \u00ab M\u00e9thodes d'essai et exigences pour les c\u00e2bles d'\u00e9nergie isol\u00e9s extrud\u00e9s et leurs accessoires pour des tensions assign\u00e9es de 30 kV (Um = 36 kV) et au-dessus jusqu'\u00e0 150 kV (Um = 170 kV) \u00bb ;<\/li>\n\n\n\n<li>Norme nationale : GB\/T 12706 \u00ab C\u00e2bles d'\u00e9nergie \u00e0 isolation extrud\u00e9e et leurs accessoires pour tensions assign\u00e9es de 1 kV (Um=1,2 kV) \u00e0 35 kV (Um=40,5 kV) \u00bb ;<\/li>\n\n\n\n<li>Le produit a pass\u00e9 le test de type du Centre national de supervision et d'inspection de la qualit\u00e9 des fils et c\u00e2bles et r\u00e9pond aux normes nationales de l'industrie de l'\u00e9lectricit\u00e9.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>XI. Service apr\u00e8s-vente<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>P\u00e9riode de garantie du produit : 18 mois \u00e0 compter de la date de fabrication, ou 12 mois \u00e0 compter de la date de mise en service (le premier terme \u00e9chu).<\/li>\n\n\n\n<li>Pendant la p\u00e9riode de garantie, les produits seront r\u00e9par\u00e9s ou remplac\u00e9s gratuitement en cas de probl\u00e8mes de qualit\u00e9.<\/li>\n\n\n\n<li>Nous fournissons un support technique, des conseils d'installation et des services personnalis\u00e9s (adaptation \u00e0 des sp\u00e9cifications et conditions de travail sp\u00e9ciales).<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Description du document<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les param\u00e8tres techniques de ce manuel sont bas\u00e9s sur des conditions de fonctionnement standard. Les conditions de fonctionnement sp\u00e9ciales doivent \u00eatre personnalis\u00e9es en fonction des besoins r\u00e9els. Les sp\u00e9cifications finales seront soumises \u00e0 l'accord technique du produit et au rapport d'essai de type.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Annexe : Sch\u00e9ma de pr\u00e9sentation du produit<\/strong><strong><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1002\" height=\"657\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/8.7-15kV-fully-cold-shrinkable-three-core-indoor-terminal.png\" alt=\"terminal int\u00e9rieur r\u00e9tractable \u00e0 froid pour trois conducteurs\" class=\"wp-image-543\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/8.7-15kV-fully-cold-shrinkable-three-core-indoor-terminal.png 1002w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/8.7-15kV-fully-cold-shrinkable-three-core-indoor-terminal-300x197.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/8.7-15kV-fully-cold-shrinkable-three-core-indoor-terminal-768x504.png 768w\" sizes=\"(max-width: 1002px) 100vw, 1002px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>I. Product Overview The 8.7\/15kV fully cold-shrink three-core indoor terminal is a cold-shrink accessory specifically designed for indoor terminals of [&hellip;]<\/p>\n","protected":false},"featured_media":543,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[17],"class_list":["post-542","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-cold-shrinkable-cable-series"],"acf":{"products_imagines":[543,544],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/products\/542","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/544"},{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/543"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media\/543"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/media?parent=542"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/fr\/wp-json\/wp\/v2\/product_category?post=542"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}