{"id":611,"date":"2026-01-26T05:15:25","date_gmt":"2026-01-26T05:15:25","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=611"},"modified":"2026-09-14T01:48:44","modified_gmt":"2026-09-14T01:48:44","slug":"ch3-24kv-225-630-1600a-contact-box","status":"publish","type":"products","link":"https:\/\/yieou.com\/it\/product\/ch3-24kv-225-630-1600a-contact-box\/","title":{"rendered":"Scatola contatti CH3-24kV\/225 630-1600A per quadri MT estraibili (centrati)"},"content":{"rendered":"<h3 class=\"wp-block-heading\">Panoramica del prodotto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/it\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">La scatola contatti CH3-24kV\/225 630-1600A per quadri di manovra estraibili a montaggio centrale<\/a> \u00e8 fabbricato utilizzando un processo di resina epossidica APG (Automatic Pressure Gelation) con una struttura di stampaggio a gel di pressione. \u00c8 un dispositivo di connessione isolante dedicato per estraibili di tipo carrello classe 24kV <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a>principalmente applicato in quadri di manovra estraibili a montaggio centrale di classe 24 kV. Il dispositivo svolge le funzioni di isolamento e transizione di connessione, fornendo un'efficace protezione isolante per i contatti interni del quadro di manovra. \u00c8 adatto per applicazioni di trasmissione di potenza a corrente media, garantendo il funzionamento sicuro e stabile dei sistemi di potenza elettrica.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ambito di applicazione<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Questa scatola di contatti \u00e8 applicabile a quadri estraibili di tipo carrellato classe 24kV ed \u00e8 comunemente utilizzata in sistemi di distribuzione elettrica, sottostazioni industriali, sale di distribuzione di edifici di grandi dimensioni, sistemi di distribuzione di imprese minerarie e industriali e installazioni elettriche simili. Funziona come componente di isolamento protettivo e di transizione di connessione per i contatti interni del quadro, fornendo una garanzia di isolamento affidabile per la commutazione e l'isolamento dei circuiti ad alta tensione, e soddisfacendo i requisiti di trasmissione di potenza a corrente media.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Condizioni operative<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L'altitudine di installazione non deve superare i 1000 m sul livello del mare;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura dell'aria ambiente: da -10\u00b0C a +40\u00b0C; l'umidit\u00e0 relativa non deve superare il 95% a 20\u00b0C;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il sito di installazione deve essere privo di gas, vapori, polvere e altri mezzi esplosivi o corrosivi che potrebbero degradare significativamente le prestazioni isolanti della scatola di contatto;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il dispositivo deve essere installato in luoghi privi di forti vibrazioni e urti meccanici, per garantirne l'integrit\u00e0 strutturale;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Adatto per installazione interna; compatibile con configurazioni di montaggio su barra DIN standard.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Caratteristiche del prodotto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prestazioni di isolamento superiori: Formato utilizzando il processo di resina epossidica APG, il prodotto presenta eccellenti propriet\u00e0 isolanti, isolando efficacemente i circuiti ad alta tensione e prevenendo rischi di dispersione e cortocircuito, con elevata resistenza alle sovratensioni impulsive.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Struttura robusta e durevole: la costruzione monolitica stampata garantisce un'elevata resistenza meccanica, in grado di sopportare sollecitazioni meccaniche ed elettriche all'interno del quadro elettrico, con conseguente prolungamento della vita utile;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Controllo accurato dell'aumento di temperatura: Durante il funzionamento continuo a corrente nominale, l'aumento di temperatura all'uscita del terminale non supera i 65\u00b0C, garantendo efficacemente un funzionamento sicuro dell'apparecchiatura e prevenendo guasti causati da un eccessivo aumento di temperatura;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Installazione semplice: dimensioni di montaggio standardizzate compatibili con quadri elettrici convenzionali a 24 kV montati centralmente, che facilitano l'installazione e la sostituzione in loco;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Resistenza alla corrosione e all'ossidazione: Il materiale in resina epossidica offre un'eccellente resistenza alla corrosione e all'ossidazione, consentendo prestazioni affidabili in un'ampia gamma di ambienti elettrici difficili.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eccellente finitura superficiale: superficie liscia e priva di bave per una comoda installazione, con buone caratteristiche ignifughe e resistenti all'usura.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Parametri Tecnici<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Parametro<\/th><th>Specifiche<\/th><\/tr><\/thead><tbody><tr><td>Tensione nominale<\/td><td>24 kV<\/td><\/tr><tr><td>Corrente nominale<\/td><td>630 A \u2013 1600 A<\/td><\/tr><tr><td>Tensione di tenuta alla frequenza di rete<\/td><td>55 kV \/ 1 min<\/td><\/tr><tr><td>Tensione di tenuta all'impulso atmosferico<\/td><td>125 kV<\/td><\/tr><tr><td>Temperatura di Transizione Vetrosa<\/td><td>\u2265 105\u00b0C<\/td><\/tr><tr><td>Distanza di isolamento superficiale<\/td><td>520 mm<\/td><\/tr><tr><td>Distanza tra i centri di montaggio<\/td><td>225 mm<\/td><\/tr><tr><td>Limite di aumento della temperatura<\/td><td>Aumento della temperatura dell'uscita del terminale non superiore a 65\u00b0C alla corrente nominale<\/td><\/tr><tr><td>Materiale<\/td><td>Alloggiamento in resina epossidica + contatti in lega di rame<\/td><\/tr><tr><td>Grado di Protezione Ingressi<\/td><td>IP67<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"324\" height=\"324\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CH3-24kV-225-630-1600A-Contact-Box-for-Withdrawable-Medium-Voltage-Center-mounted-Switchgear.png\" alt=\"Scatola contatti CH3-24kV-225-630-1600A\" class=\"wp-image-612\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CH3-24kV-225-630-1600A-Contact-Box-for-Withdrawable-Medium-Voltage-Center-mounted-Switchgear.png 324w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CH3-24kV-225-630-1600A-Contact-Box-for-Withdrawable-Medium-Voltage-Center-mounted-Switchgear-300x300.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CH3-24kV-225-630-1600A-Contact-Box-for-Withdrawable-Medium-Voltage-Center-mounted-Switchgear-150x150.png 150w\" sizes=\"(max-width: 324px) 100vw, 324px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The CH3-24kV\/225 630-1600A contact box for withdrawable centrally-mounted switchgear is manufactured using an epoxy resin APG (Automatic Pressure [&hellip;]<\/p>\n","protected":false},"featured_media":612,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[34],"class_list":["post-611","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-insulation-components-series"],"acf":{"products_imagines":[612,613],"short_describe":"<p><span style=\"color: #334155; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif; font-size: 16px; white-space: pre-wrap;\">The CH3-24kV\/225 630-1600A contact box for withdrawable centrally-mounted switchgear is manufactured using an epoxy resin APG (Automatic Pressure Gelation) process with a pressure gel molding structure.<\/span><\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/products\/611","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/media\/613"},{"embeddable":true,"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/media\/612"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/media\/612"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/media?parent=611"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/product_category?post=611"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}