{"id":684,"date":"2026-01-26T06:45:07","date_gmt":"2026-01-26T06:45:07","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=684"},"modified":"2026-09-16T02:07:01","modified_gmt":"2026-09-16T02:07:01","slug":"high-altitude-type-3av3-bushing","status":"publish","type":"products","link":"https:\/\/yieou.com\/it\/product\/high-altitude-type-3av3-bushing\/","title":{"rendered":"TG3-35Q\/290\u00d7290\u00d7528 (High-Altitude Type) 3AV3 Bushing (Power Frequency Withstand Voltage: 95kV\/1min; Partial Discharge: \u22645pC @ 40.5kV)"},"content":{"rendered":"<p class=\"wp-block-paragraph\">TG3-35Q\/260\u00d7260\u00d7450 Wall-Through Bushing<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Panoramica del prodotto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/it\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">La boccola passante a muro TG3-35Q\/260\u00d7260\u00d7450<\/a> \u00e8 un componente isolante in resina epossidica specificamente progettato per sistemi di alimentazione ad alta tensione da 35kV. \u00c8 utilizzato principalmente in centrali elettriche, sottostazioni e alta tensione <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a> armadi per consentire elementi conduttivi (<a href=\"https:\/\/en.wikipedia.org\/wiki\/Busbar\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Busbar\" target=\"_blank\" rel=\"noopener\">sbarre colletrici<\/a>\/copper bars) to pass through walls, partitions, or other grounded structures, while providing core functions of insulation support and electrical connection to ensure safe and stable operation of power systems.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Parametri Tecnici<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Parametro<\/th><th>Valore<\/th><\/tr><\/thead><tbody><tr><td>Tensione nominale<\/td><td>40.5kV (compatible with 35kV systems)<\/td><\/tr><tr><td>Frequenza nominale<\/td><td>15\u201360Hz<\/td><\/tr><tr><td>Corrente nominale<\/td><td>630A\u20133150A (customizable upon request)<\/td><\/tr><tr><td>Dimensioni complessive<\/td><td>260\u00d7260\u00d7450mm (mounting flange \u00d7 total height)<\/td><\/tr><tr><td>Dimensioni della flangia di montaggio<\/td><td>260mm \u00d7 260mm<\/td><\/tr><tr><td>Materiale<\/td><td>Epoxy resin, APG process<\/td><\/tr><tr><td>Colore<\/td><td>Red (natural epoxy resin color)<\/td><\/tr><tr><td>Tensione di tenuta a frequenza di rete (1 min)<\/td><td>95kV (dry condition)<\/td><\/tr><tr><td>Tensione di tenuta all'impulso atmosferico (picco)<\/td><td>185kV<\/td><\/tr><tr><td>Livello di scarica parziale<\/td><td>\u22645pC (at 1.1Um)<\/td><\/tr><tr><td>Distanza di isolamento superficiale<\/td><td>In accordance with GB\/T 311 and relevant standards<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Caratteristiche del prodotto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prestazioni di isolamento superiori<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Formed using the epoxy resin monolithic APG (Automatic Pressure Gelation) process, the structure is dense and void-free, yielding high electrical insulation strength that effectively withstands the risk of dielectric breakdown at the 35kV level.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Shed-type outer insulation design increases creepage distance and enhances resistance to pollution flashover and moisture, suitable for outdoor and heavily polluted environments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Reliable Mechanical Strength<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The epoxy resin matrix offers excellent impact and flexural resistance, capable of withstanding electromagnetic force impulses during busbar short-circuit events, with no tendency toward deformation or cracking under long-term operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Square flange mounting structure provides uniform load distribution, ensuring secure connection to the cabinet or wall with outstanding seismic performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Optimized Electric Field Design<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An internal shielding layer (optional) can be integrated to homogenize electric field distribution, suppress partial discharge, extend service life, and improve system operational stability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Smooth inner and outer surfaces with no sharp edges eliminate electric field concentration and reduce the risk of corona discharge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Forte Adattabilit\u00e0 Ambientale<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wide operating temperature range (\u221240\u00b0C to +120\u00b0C) with resistance to extreme temperatures and aging, enabling stable operation in outdoor, indoor, and high-altitude environments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Flame-retardant and chemically resistant; unaffected by biological factors such as mold and insects, making it suitable for complex industrial environments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Installazione e manutenzione convenienti<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Standardized flange dimensions and mounting hole patterns are directly compatible with mainstream 35kV high-voltage switchgear cabinets such as the KYN61-40.5.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Compact structure and lightweight design require no additional maintenance \u2014 only periodic cleaning of surface contamination is necessary.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ambito di applicazione<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Applicable to three-phase AC power systems with rated voltage of 10\u201335kV and frequency of 15\u201360Hz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Primary application scenarios:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Internal busbar wall-through connections in high-voltage switchgear cabinets (e.g., KYN61-40.5 type).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wall\/partition busbar penetrations in substations and distribution rooms.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Insulation support and conductive connections in box-type substations, ring main units, and similar distribution equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">35kV high-voltage power distribution systems in industrial enterprises, mines, petrochemical plants, and related sectors.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Condizioni operative<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">(I) Normal Service Environment<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ambient temperature: \u221240\u00b0C to +120\u00b0C (short-term withstand up to 155\u00b0C).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude: \u22643000m (derating or custom design required beyond this limit).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Relative humidity: daily average \u226495%, monthly average \u226490% (condensation-free conditions preferred).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pollution level: Class IV or below (enhanced creepage distance models required for heavily polluted environments).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Locations free from severe vibration, shock, and flammable\/explosive or strongly corrosive gases.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(II) Installation Requirements<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mounting orientation: vertical or horizontal installation is permissible; the flange face must be in full, flush contact with the wall or cabinet surface to ensure uniform load distribution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Conductive connection: when threading copper bars\/busbars through the interior, ensure uniform clearance between the conductor and the inner wall of the bushing to avoid localized stress concentration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sealing and protection: a sealing gasket must be installed between the flange and the mounting surface to prevent ingress of dust and moisture and to enhance insulation reliability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Safety clearance: after installation, minimum electrical clearances between live parts and grounded parts must comply with GB\/T 311 and other applicable standards.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Precauzioni<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Transport and Storage: avoid impacts and drops; store in a dry, well-ventilated environment free from corrosive gases to prevent surface moisture absorption and contamination.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pre-installation Inspection: verify that the product exterior is free from cracks and damage, that dimensions and mounting hole patterns match the installation site, and that electrical performance tests have been passed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Operational Maintenance: periodically clean surface contamination from the bushing; inspect flange connecting bolts for loosening; if partial discharge or surface tracking marks are detected, shut down immediately for inspection and repair.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Type Selection: select the appropriate model specification based on the system rated current, voltage class, and installation space to avoid overloading or dimensional incompatibility.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"366\" height=\"366\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-290\u00d7290\u00d7528-High-Altitude-Type-3AV3-Bushing.png\" alt=\"TG3-35Q-290\u00d7290\u00d7528-Tipo Alta Quota 3AV3-Bussola\" class=\"wp-image-685\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-290\u00d7290\u00d7528-High-Altitude-Type-3AV3-Bushing.png 366w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-290\u00d7290\u00d7528-High-Altitude-Type-3AV3-Bushing-300x300.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/TG3-35Q-290\u00d7290\u00d7528-High-Altitude-Type-3AV3-Bushing-150x150.png 150w\" sizes=\"(max-width: 366px) 100vw, 366px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>TG3-35Q\/260\u00d7260\u00d7450 Wall-Through Bushing Product Overview The TG3-35Q\/260\u00d7260\u00d7450 wall-through bushing is an epoxy resin insulating component specifically designed for 35kV high-voltage [&hellip;]<\/p>\n","protected":false},"featured_media":685,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[34],"class_list":["post-684","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-insulation-components-series"],"acf":{"products_imagines":[685,686],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/products\/684","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/media\/686"},{"embeddable":true,"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/media\/685"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/media\/685"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/media?parent=684"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/it\/wp-json\/wp\/v2\/product_category?post=684"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}