{"id":2780,"date":"2026-09-08T06:12:21","date_gmt":"2026-09-08T06:12:21","guid":{"rendered":"https:\/\/yieou.com\/?p=2780"},"modified":"2026-09-08T06:12:23","modified_gmt":"2026-09-08T06:12:23","slug":"separable-connector-transformer-elbow-bushing-fit","status":"publish","type":"post","link":"https:\/\/yieou.com\/ko\/separable-connector-transformer-elbow-bushing-fit\/","title":{"rendered":"\ubcc0\uc555\uae30 \ubd80\uc2f1 \uc778\uc11c\ud2b8\uc640 \ub85c\ub4dc \ube0c\ub808\uc774\ud06c \uc5d8\ubcf4\uc6b0\ub97c \ub9de\ucd94\ub294 \ubc29\ubc95"},"content":{"rendered":"<p class=\"wp-block-paragraph\">A transformer cable compartment can contain the correct voltage and current labels while still presenting a difficult elbow connection. The insert may sit farther forward than expected, the cable may pull the elbow away from its axis, or the exposed interface may belong to a different bushing construction. These details matter when a transformer manufacturer is approving an accessory assembly or a contractor is resolving a connection that will not seat correctly. Matching a Separable Connector loadbreak elbow starts at the transformer interface and continues through the installed position of the insert, the elbow contact and the supported cable.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Quick Answer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Match the loadbreak elbow to the exact interface provided by the transformer bushing insert, and match that insert separately to the transformer bushing well. Confirm the electrical ratings, mating geometry, contact arrangement and installed dimensions of both connections. Then verify that the elbow can reach its specified seated position without interference from the cabinet or sustained bending force from the cable. Similar appearance, a shared 200A label or partial engagement does not establish a complete match.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">At YIEOU, we manufacture medium-voltage cable accessories and match our <a href=\"https:\/\/yieou.com\/ko\/product_category\/american-cable-accessories\/\"><strong>\ubd84\ub9ac\ud615 \ucee4\ub125\ud130<\/strong><\/a> assemblies to transformer and cable requirements. Our JY ZT-15\/200 loadbreak elbow and JY DTT-15\/200 bushing insert are 15kV, 200A products relevant to this arrangement. The transformer well, selected variants and installation instructions determine the final assembly.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Identify the Transformer Bushing Construction First<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The word bushing can describe different equipment components. A bushing well accepts a separate insert, which then provides the interface for the elbow. An integral loadbreak bushing already incorporates the elbow connection interface. These constructions affect the required accessory parts and the position from which the elbow projects into the compartment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With a well-and-insert arrangement, there are two equipment-side connections to resolve. The insert attaches to the well, while the elbow mates with the insert. An elbow that matches the insert does not establish whether the insert belongs in that transformer well. Similarly, a compatible well connection does not establish the suitability of every Separable Connector elbow that resembles the selected model.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Our JY TGZ-200 casing seat is a bushing-well component used with matching inserts in pad-mounted transformers and related equipment. Our JY DTT-15\/200 insert threads into a compatible bushing well. The distinction helps define the Separable Connector assembly before an order contains either an unnecessary insert or an omitted equipment-side component.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For an existing transformer, begin with the bushing identification and equipment drawing. A photograph can help locate markings and identify the general construction, but dimensions hidden inside a well cannot be confirmed from a front view. For new transformers, the bushing specification and compartment drawing provide the basis for matching the accessories before the first assembly is built.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><a href=\"https:\/\/yieou.com\/ko\/product\/jy-tgz-200-15kv-24kv-200a-casing-seat\/\"><img decoding=\"async\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-TGZ-200-15kV24kV-200A-Casing-seat-1.png\" alt=\"JY TGZ-200 casing seat for a matching transformer bushing insert\"\/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Read the Mating Drawing as an Installed Assembly<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A catalogue outline gives the overall size of a component. A mating drawing establishes how two components meet. Both are useful, but they answer different questions. When reviewing a Separable Connector assembly, the installed position of the insert is as important as its overall length.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">On the well side, the review covers the specified connection to the well stud, the seating surfaces and the installed location of the insert. On the elbow side, it covers the interface profile, contact engagement and the position associated with full seating. These relationships belong to the defined interface system. Matching one accessible diameter does not verify the complete connection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The reference points on the drawings also need to agree. One drawing may show a dimension from the transformer mounting face, while another measures from the insert collar. Comparing those values directly can give a misleading estimate of available space. We normally relate the accessory dimensions to the equipment mounting plane so that the completed Separable Connector position can be understood inside the actual compartment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Table 1. What Each Drawing Confirms<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Drawing or detail<\/th><th>Main matching question<\/th><th>Practical result<\/th><\/tr><\/thead><tbody><tr><td>Transformer bushing identification<\/td><td>Is this a well or an integral interface?<\/td><td>Defines whether a separate insert is required.<\/td><\/tr><tr><td>Well and insert connection detail<\/td><td>Does the insert fit the specified well connection?<\/td><td>Establishes the equipment-side assembly.<\/td><\/tr><tr><td>Insert and elbow mating detail<\/td><td>Do the interface and contact arrangements correspond?<\/td><td>Defines the compatible elbow connection.<\/td><\/tr><tr><td>Installed assembly outline<\/td><td>Where does the seated elbow sit relative to the tank?<\/td><td>Reveals interference and cable alignment issues.<\/td><\/tr><tr><td>Cable entry and support layout<\/td><td>Can the cable reach that position without pulling the elbow sideways?<\/td><td>Establishes a workable cable route.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A short comparison of these Separable Connector drawings often resolves uncertainty more effectively than comparing several product photographs. Where a dimension or part identification is missing, we can identify the particular information needed to finish the match.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Keep Electrical Ratings Attached to the Exact Interface<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Electrical compatibility remains essential even when the proposed assembly appears to fit. The elbow, insert and equipment interface need compatible voltage classes and current ratings. The transformer connection requirement also includes the applicable insulation and short-circuit duties. A higher rating on one accessory does not raise the rating of the complete Separable Connector connection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For the 15kV, 200A arrangement discussed here, our JY ZT-15\/200 elbow and JY DTT-15\/200 insert provide a starting product combination. Their model names do not replace confirmation of the transformer well or the selected cable contact. If the project specifies a different voltage family, the entire mating arrangement needs review rather than substitution based on current alone.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For American-style systems, IEEE 386 addresses ratings, construction features and tests for separable insulated connector systems. A project specification should identify the applicable interface and requirements; a general reference to the standard does not identify every compatible product combination. The required edition and supporting documentation can be confirmed during project review.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A 600A deadbreak interface or a 630A European-style connection cannot be treated as an alternative mating surface for this 200A elbow. Nor does the loadbreak designation remove the need for rated operating conditions and the approved procedure. A Separable Connector used in a loadbreak assembly must have the appropriate operating function throughout the matched connection.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Distinguish Insert Installation from Elbow Seating<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The insert must be correctly installed in the well before Separable Connector elbow seating can be assessed. A loose, incorrectly positioned or unsuitable insert changes the interface presented to the elbow. Attempting to compensate at the cable end can conceal the original problem and leave the equipment-side attachment unresolved.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The JY DTT-15\/200 insert incorporates an internal tool feature for torque-controlled installation. That feature matters because attachment to the well is a defined mechanical connection. The specified tool and installation torque belong to the particular insert and well combination; there is no useful universal tightening value for every transformer bushing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This insert also incorporates a yellow latch indicator ring to help assess elbow seating. Its appearance must be interpreted using the instructions for the matched assembly. A visible ring is not a voltage indicator, and ring visibility alone cannot establish the condition of internal contacts, the cable termination or the transformer insulation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The Separable Connector review therefore separates two questions: whether the insert has been installed as specified, and whether the elbow has reached its required position on that insert. An apparent gap must be compared with the actual installation criteria. Assuming that all visible gaps are defects can be as misleading as accepting every connection that appears nearly seated.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><a href=\"https:\/\/yieou.com\/ko\/product\/jy-dtt-15-200-15kv-200abushing-insert\/\"><img decoding=\"async\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-DTT-15-200-15kV-200ABushing-Insert-2.png\" alt=\"JY DTT-15\/200 bushing insert sectional drawing\"\/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Resolve a Seating Problem Before Changing Parts<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">When an elbow will not seat, the observed symptom helps identify which part of the assembly deserves attention. The work belongs in an isolated, tested and grounded installation under the applicable procedure. Repeated force or trial insertion on energized equipment is not an appropriate method of identifying a Separable Connector mismatch.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Resistance early in the mating movement can justify reviewing the interface identification, surface condition and alignment. Difficulty nearer the expected seated position can also involve the probe or contact assembly, preparation dimensions or the installed position of the insert. The symptom alone does not prove a cause. Inspection and the product instructions determine what needs correction.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contamination, damaged mating surfaces or an unsuitable lubricant can interfere with a correctly specified pair. The prescribed cleaning method and compatible lubricant support the intended fit. Extra lubricant does not turn an incorrect interface into a compatible one, and modifying the rubber profile or contact to make the parts engage defeats the original product specification.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cable force introduces a separate problem. An elbow may align when the cable is supported, then tilt as that support changes. In that situation, changing the insert without addressing the cable route may leave the same difficulty. A Separable <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" target=\"_blank\" rel=\"noopener\">\ucee4\ub125\ud130<\/a> assembly needs a cable arrangement that allows the body to remain aligned after installation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A useful technical enquiry describes where the resistance appears, whether the cable is supported, which components are new and which remain installed, and the markings on both mating parts. This gives us a clearer basis for reviewing the connection than a request for an elbow that is simply longer, softer or easier to push.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Allow Room for the Fully Seated Elbow and Its Movement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The transformer compartment must accommodate more than the outline of the stationary elbow. The accessory also needs the access required by its installation and operating instructions. Nearby phase connections, the compartment door, barriers and cable supports can affect whether the specified movement is possible.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Consider a transformer fitted with a replacement well or an alternative approved insert. Even where the elbow interface remains compatible, a change in installed projection can move the cable connection toward the door or away from its support. The Separable Connector may therefore remain electrically suitable while the previous cable route becomes impractical.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The cable bend should allow the elbow to approach the insert along the required axis. A sharp change of direction immediately below the body can create sustained side loading. Cable support location, bending radius and available length all contribute to the final position. The accessory should not be used to pull a reluctant cable into the cabinet layout.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Operating access also depends on the position of the pulling eye and the tool approach. Our JY ZT-15\/200 elbow includes a reinforced pulling eye as part of its loadbreak construction. Its presence does not demonstrate that the installed Separable Connector can be operated within a particular enclosure. That depends on the equipment layout and the approved operating method.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For transformer production, checking one representative installed arrangement can reveal a door or support interference that separate component drawings missed. Any resulting change to the bushing projection, accessory selection or cable support then becomes part of the assembly specification.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For a three-phase transformer, review each phase position rather than assuming the centre connection represents the whole compartment. A side wall or divider can restrict one elbow even when the other two have adequate access. Likewise, a cable entry that is offset from the bushing axis may require a different support arrangement. This is a layout question to resolve around the approved accessories, without bending an insert or changing the intended mating direction.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There is also a difference between space available with the door open and space remaining after the compartment is closed. The final arrangement needs to accommodate the seated body, cable bend and any specified accessory clearances in both conditions. A dimensioned section through the compartment helps reveal these relationships when a front elevation shows the parts apparently fitting side by side.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><a href=\"https:\/\/yieou.com\/ko\/product\/jy-zt-15-200-15kv-200a-loadbreak-elbow-connector\/\"><img decoding=\"async\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-ZT-15-200-15kV-200A-Loadbreak-Elbow-Connector-2.png\" alt=\"JY ZT-15\/200 loadbreak elbow with pulling eye and grounding lead\"\/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Check the Cable End Without Losing the Equipment Reference<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Once the transformer side is established, the cable end still has to suit the selected elbow. The diameter over cable insulation determines the relevant body or adapter selection, while conductor material, cross-section and construction affect the contact. Cable sheath diameter answers a different question and cannot substitute for insulation diameter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Two cables with the same nominal cross-section can place different demands on a Separable Connector. Their insulation dimensions and stiffness may differ. One may fit the available cable route while the other requires a change to the support position. The bushing insert does not correct either a cable fit problem or insufficient bending space.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The elbow contact and probe also form a coordinated assembly. For our JY ZT-15\/200, the loadbreak probe includes an arc-follower tip. The correct parts and preparation dimensions belong to that elbow configuration. Combining parts from different kits because their threads appear to engage does not establish the required internal geometry.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In a transformer accessory schedule, it is useful to distinguish the equipment mating interface from the cable-specific elbow option. Several Separable Connector cable options may use the same confirmed equipment interface while requiring different contacts or body selections. This keeps the Separable Connector specification clear without assuming that every cable entry takes an identical kit.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Confirm One Transformer Connection Before Repeat Supply<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A practical Separable Connector assembly review brings together the transformer bushing identification, the proposed insert and elbow references, the cable data and the installed layout. At YIEOU, we support OEM transformer projects by matching our cable accessories to the specified equipment connection. Missing information can be resolved around the particular interface or dimension involved, without delaying an initial discussion until every project document is complete.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For an OEM transformer programme, a representative assembly can confirm physical access, the specified seating indication and cable alignment. Physical fit is only one part of acceptance. The required electrical documentation and tests remain separate from a mechanical trial, and an apparently successful insertion does not validate a different voltage or operating duty.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Once the combination is agreed, retain the exact well, insert, elbow and cable-contact references with the relevant drawing revisions. If the transformer bushing supplier, cable construction or compartment arrangement changes, the affected part of the Separable Connector assembly can then be reviewed without reopening every unchanged detail.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Our <a href=\"https:\/\/yieou.com\/ko\/product_category\/american-cable-accessories\/\"><strong>\ubd84\ub9ac\ud615 \ucee4\ub125\ud130<\/strong><\/a> range includes the loadbreak elbows, bushing inserts and related accessories used to build these connections. Send the transformer bushing reference, cable information and a compartment drawing or photograph, and we can help match the assembly and clarify the remaining details for quotation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Does every transformer need a separate bushing insert?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. A transformer with a compatible integral loadbreak bushing already provides the elbow interface. A well-and-insert construction requires the corresponding insert, so the equipment drawing determines the parts required for the Separable Connector assembly.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can matching overall dimensions prove that an elbow fits an insert?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. Overall dimensions help assess space, while the mating profile, contacts and installed seating position establish compatibility. The exact interface identification and assembly drawings remain necessary even when two components look alike.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What does the yellow ring on the JY DTT-15\/200 indicate?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">It is a latch indicator intended to help assess elbow installation. Interpret it according to the matched product instructions; it does not indicate whether the circuit is energized or verify the entire Separable Connector termination.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Should a difficult elbow connection receive more lubricant?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Only use the lubricant and application method specified for the product. Difficulty may involve identification, contamination, alignment, preparation or damaged parts, so additional lubricant is not a substitute for finding the cause.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can the same elbow remain suitable after changing the transformer well?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Possibly, if the replacement well and insert provide the confirmed interface and meet the electrical requirements. Recheck the installed projection and cable alignment because a change in equipment-side dimensions can affect how the Separable Connector fits inside the compartment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can a successful trial fit confirm loadbreak performance?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. A mechanical Separable Connector trial helps assess fit and access. Loadbreak capability depends on the rated, matched assembly and its specified operating conditions, with the required product documentation and approved operating procedure.<\/p>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>A transformer cable compartment can contain the correct voltage and current labels while still presenting a difficult elbow connection. The [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2781,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2780","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-2"],"acf":[],"_links":{"self":[{"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/posts\/2780","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/comments?post=2780"}],"version-history":[{"count":1,"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/posts\/2780\/revisions"}],"predecessor-version":[{"id":2782,"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/posts\/2780\/revisions\/2782"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/media\/2781"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/media?parent=2780"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/categories?post=2780"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yieou.com\/ko\/wp-json\/wp\/v2\/tags?post=2780"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}