{"id":1551,"date":"2026-05-08T00:00:00","date_gmt":"2026-05-08T00:00:00","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1551"},"modified":"2026-09-09T07:19:15","modified_gmt":"2026-09-09T07:19:15","slug":"35kv-line-suspension-arrester","status":"publish","type":"products","link":"https:\/\/yieou.com\/pl\/product\/35kv-line-suspension-arrester\/","title":{"rendered":"Odgromnik wisz\u0105cy linii 35kV"},"content":{"rendered":"<p class=\"wp-block-paragraph\">35kV Line-Suspended Surge <a href=\"https:\/\/en.wikipedia.org\/wiki\/Lightning_arrester\" target=\"_blank\" rel=\"noopener\">Arrester<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Przegl\u0105d produktu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/pl\/products\/\">Odgromnik wisz\u0105cy linii 35kV<\/a> (Model HY(YH)5WS-51\/134, HY(YH)5WX-54\/142) is a gapless metal oxide surge <a href=\"https:\/\/en.wikipedia.org\/wiki\/Lightning_arrester\" target=\"_blank\" rel=\"noopener\">odgromnik<\/a> designed specifically for 35kV overhead lines. It features a silicone rubber composite housing and a suspension-type mounting structure, allowing direct installation on 35kV overhead lines. The arrester effectively limits lightning overvoltages and switching overvoltages to protect the insulation of lines and distribution equipment from damage.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cechy produktu<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Wydajno\u015b\u0107 elektryczna i ochronna<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wysokowydajne warystory tlenku cynku o doskona\u0142ych charakterystykach napi\u0119ciowo-pr\u0105dowych zapewniaj\u0105 niskie napi\u0119cie szcz\u0105tkowe i du\u017c\u0105 zdolno\u015b\u0107 przenoszenia pr\u0105du, skutecznie ograniczaj\u0105c przepi\u0119cia od wy\u0142adowa\u0144 atmosferycznych i \u0142\u0105czeniowe na liniach napowietrznych 35kV, zapobiegaj\u0105c uszkodzeniu izolacji.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Szybka pr\u0119dko\u015b\u0107 reakcji umo\u017cliwia natychmiastowe dzia\u0142anie po pojawieniu si\u0119 przepi\u0119cia, sprawnie odprowadzaj\u0105c pr\u0105d udarowy i zapobiegaj\u0105c jego przedostaniu si\u0119 do urz\u0105dze\u0144 linii. Wydajno\u015b\u0107 ochrony jest stabilna i niezawodna.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Doskona\u0142e nieliniowe charakterystyki napi\u0119ciowo-pr\u0105dowe skutkuj\u0105 ekstremalnie niskim pr\u0105dem up\u0142ywu i niskim rozpraszaniem mocy przy normalnym napi\u0119ciu roboczym. W warunkach przepi\u0119cia urz\u0105dzenie szybko przewodzi i automatycznie przywraca sw\u00f3j stan izolacyjny po roz\u0142adowaniu pr\u0105du \u2013 bezobs\u0142ugowo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cechy konstrukcyjne i bezpiecze\u0144stwa<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Integralna obudowa z kompozytu gumy silikonowej jest bezszwowa i pozbawiona pustych przestrzeni, co zapewnia doskona\u0142e w\u0142a\u015bciwo\u015bci uszczelniaj\u0105ce, skutecznie zapobiegaj\u0105c przenikaniu wilgoci i zanieczyszcze\u0144 do wn\u0119trza oraz chroni\u0105c warystory przed uszkodzeniami spowodowanymi wilgoci\u0105.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zintegrowana konstrukcja modu\u0142owa zawiera wbudowany zacisk do monta\u017cu zawieszenia, kompatybilny z izolatorami napowietrznymi, nie wymagaj\u0105cy dodatkowego wyposa\u017cenia pomocniczego i nadaj\u0105cy si\u0119 do instalacji napowietrznej.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wbudowany zacisk uziemiaj\u0105cy mo\u017cna pod\u0142\u0105czy\u0107 bezpo\u015brednio do licznika iskiernika lub do ziemi, co umo\u017cliwia wygodn\u0105 instalacj\u0119 bez ryzyka pora\u017cenia pr\u0105dem i zapewnia bezpiecze\u0144stwo personelu obs\u0142ugi i konserwacji.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bezszwowa konstrukcja eliminuje pr\u0105d pe\u0142zaj\u0105cy o cz\u0119stotliwo\u015bci sieciowej podczas pracy, usuwaj\u0105c ryzyko eksplozji lub po\u017caru spowodowane pr\u0105dem pe\u0142zaj\u0105cym o cz\u0119stotliwo\u015bci sieciowej i zapewniaj\u0105c wysoki poziom bezpiecze\u0144stwa operacyjnego.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Odporno\u015b\u0107 na czynniki \u015brodowiskowe i pogodowe<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Doskona\u0142a odporno\u015b\u0107 na warunki atmosferyczne w szerokim zakresie temperatur od -40\u00b0C do +90\u00b0C. Obudowa z gumy silikonowej zachowuje swoj\u0105 elastyczno\u015b\u0107 i w\u0142a\u015bciwo\u015bci izolacyjne zar\u00f3wno w wysokich, jak i niskich temperaturach, bez ryzyka p\u0119kania lub krucho\u015bci, co czyni j\u0105 odpowiedni\u0105 do zastosowa\u0144 na napowietrznych liniach energetycznych na zewn\u0105trz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Odporna na wilgo\u0107, wod\u0119, zanieczyszczenia i mg\u0142\u0119 soln\u0105, co umo\u017cliwia d\u0142ugoterminow\u0105 stabiln\u0105 prac\u0119 w trudnych warunkach, takich jak wilgotno\u015b\u0107, g\u0119sty py\u0142 i nadmorska bryza solna. Niewra\u017cliwa na erozj\u0119 spowodowan\u0105 deszczem i kondensacj\u0105. Silna hydrofobowo\u015b\u0107 powierzchni gumy silikonowej skutecznie zapobiega przeskoku iskry powierzchniowej.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Odporny na starzenie, promieniowanie UV i ozon, o \u017cywotno\u015bci przekraczaj\u0105cej 20 lat. Bezobs\u0142ugowa praca obni\u017ca d\u0142ugoterminowe koszty eksploatacji i konserwacji.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cechy mechaniczne i kompatybilno\u015bci<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wysoka wytrzyma\u0142o\u015b\u0107 mechaniczna z doskona\u0142\u0105 odporno\u015bci\u0105 na uderzenia i wibracje. Odgromnik jest w stanie wytrzyma\u0107 napr\u0119\u017cenia mechaniczne spowodowane wibracjami wywo\u0142ywanymi przez wiatr oraz impulsami pr\u0105du piorunowego bez deformacji lub uszkodze\u0144. Klasa odporno\u015bci sejsmicznej: 8.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kompatybilny z napowietrznymi liniami 35kV; mo\u017cna go instalowa\u0107 bezpo\u015brednio na izolatorach wisz\u0105cych linii, charakteryzuj\u0105c si\u0119 szerok\u0105 uniwersalno\u015bci\u0105, dostosowuj\u0105c si\u0119 do r\u00f3\u017cnych typ\u00f3w s\u0142up\u00f3w i konfiguracji izolator\u00f3w wisz\u0105cych.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kompaktowy rozmiar i lekka konstrukcja. Wisz\u0105ca konstrukcja monta\u017cowa umo\u017cliwia wygodn\u0105 instalacj\u0119 bez skomplikowanych procedur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Parametry techniczne<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Kategoria parametr\u00f3w<\/td><td>Przedmiot<\/td><td>HY(YH)5WS-51\/134<\/td><\/tr><tr><td>Znamionowe parametry elektryczne<\/td><td>Napi\u0119cie systemowe (Un)<\/td><td>35kV<\/td><\/tr><tr><td><\/td><td>Napi\u0119cie znamionowe ogranicznika (Ur, warto\u015b\u0107 skuteczna)<\/td><td>51kV<\/td><\/tr><tr><td><\/td><td>Ci\u0105g\u0142e napi\u0119cie pracy (Uc, warto\u015b\u0107 skuteczna)<\/td><td>40,8 kV<\/td><\/tr><tr><td><\/td><td>Napi\u0119cie odniesienia DC 1mA (minimum)<\/td><td>73 kV<\/td><\/tr><tr><td><\/td><td>| Maximum Residual Voltage under Steep Current Impulse (peak)<\/td><td>154 kV<\/td><\/tr><tr><td><\/td><td>Maksymalne napi\u0119cie szcz\u0105tkowe przy udarze pr\u0105du piorunowego (warto\u015b\u0107 szczytowa)<\/td><td>134 kV<\/td><\/tr><tr><td><\/td><td>Maksymalne napi\u0119cie szcz\u0105tkowe przy pr\u0105dzie impulsowym prze\u0142\u0105czeniowym (warto\u015b\u0107 szczytowa)<\/td><td>114 kV<\/td><\/tr><tr><td><\/td><td>| 2000\u03bcs Square Wave Current Withstand Capability<\/td><td>400A<\/td><\/tr><tr><td><\/td><td>4\/10 Wysokonapi\u0119ciowa zdolno\u015b\u0107 udarowa<\/td><td>65 kA<\/td><\/tr><tr><td><\/td><td>Maksymalny pr\u0105d up\u0142ywu przy 0,75-krotno\u015bci napi\u0119cia referencyjnego DC<\/td><td>50\u03bcA<\/td><\/tr><tr><td><\/td><td>Droga pe\u0142zania<\/td><td>1175 mm<\/td><\/tr><tr><td>Parametry strukturalne i materia\u0142owe<\/td><td>Materia\u0142y g\u0142\u00f3wne<\/td><td>Tlenek cynku (rdze\u0144), guma silikonowa (obudowa), mied\u017a cynowana (zaciski)<\/td><\/tr><tr><td><\/td><td>Stopie\u0144 ochrony IP<\/td><td>IP65<\/td><\/tr><tr><td><\/td><td>Typ konstrukcji<\/td><td>Beziskrowy ogranicznik przepi\u0119\u0107 z tlenku metalu<\/td><\/tr><tr><td><\/td><td>Metoda monta\u017cu<\/td><td>Typ zawieszenia, kompatybilny z izolatorami kulowo-gniazdowymi nr 16<\/td><\/tr><tr><td><\/td><td>Specyfikacja zacisku uziemiaj\u0105cego<\/td><td>Gwint M10 (kompatybilny z uziemieniem przeciwnym lub bezpo\u015brednim)<\/td><\/tr><tr><td><\/td><td>Wymiary ca\u0142kowite<\/td><td>Ca\u0142kowita d\u0142ugo\u015b\u0107 1000 mm<\/td><\/tr><tr><td>Parametry \u015brodowiskowe<\/td><td>Wysoko\u015b\u0107 stosowania<\/td><td>\u22642000 m (dost\u0119pna personalizacja dla du\u017cych wysoko\u015bci)<\/td><\/tr><tr><td><\/td><td>Temperatura otoczenia<\/td><td>-40\u00b0C do +90\u00b0C (praca), -40\u00b0C do +70\u00b0C (przechowywanie)<\/td><\/tr><tr><td><\/td><td>Wilgotno\u015b\u0107 wzgl\u0119dna<\/td><td>\u2264100% (bez kondensacji)<\/td><\/tr><tr><td><\/td><td>Klasa odporno\u015bci sejsmicznej<\/td><td>Klasa 8<\/td><\/tr><tr><td>Stosowane normy<\/td><td><\/td><td>GB 11032 Bezprzerwowe odgromniki tlenkowe metalu; DL\/T 804 Wytyczne dotycz\u0105ce stosowania odgromnik\u00f3w tlenkowych metalu dla system\u00f3w elektroenergetycznych pr\u0105du przemiennego<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Aplikacje<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Napi\u0119cie znamionowe: 35 kV AC napowietrznych sieci dystrybucyjnych.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mo\u017cliwe scenariusze:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ochrona odgromowa napowietrznych linii dystrybucyjnych 35kV<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ochrona odgromowa izolator\u00f3w wisz\u0105cych i osprz\u0119tu napowietrznych linii elektroenergetycznych;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ochrona odgromowa napowietrznych linii 35kV w miejskich sieciach dystrybucyjnych, przedsi\u0119biorstwach przemys\u0142owych i g\u00f3rniczych oraz w podstacjach transformatorowych nowych \u017ar\u00f3de\u0142 energii (fotowoltaicznych\/wiatrowych);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zabezpieczenie przeciwprzepi\u0119ciowe dla napowietrznych linii 35kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cel funkcjonalny: Ograniczenie przepi\u0119\u0107 atmosferycznych i \u0142\u0105czeniowych, odprowadzenie pr\u0105du piorunowego do ziemi oraz ochrona izolacji napowietrznych linii 35kV i urz\u0105dze\u0144 przed uszkodzeniem, zapobieganie przeskoku po izolatorach i przebiciom urz\u0105dze\u0144 spowodowanym przepi\u0119ciami, zapewniaj\u0105c tym samym bezpieczn\u0105 i stabiln\u0105 prac\u0119 napowietrznych system\u00f3w dystrybucyjnych.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Warunki pracy<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Warunki normalnej pracy<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wysoko\u015b\u0107: \u22642000m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura otoczenia: od -40\u00b0C do +90\u00b0C; temperatura pracy urz\u0105dzenia zgodnie z odpowiednimi normami;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wilgotno\u015b\u0107 wzgl\u0119dna: \u2264100% (bez kondensacji);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Warunki \u015brodowiskowe: wolne od gaz\u00f3w korozyjnych, palnych i wybuchowych oraz silnych wibracji lub wstrz\u0105s\u00f3w (kompatybilne z wibracjami indukowanymi przez wiatr na liniach);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Metoda instalacji: monta\u017c za pomoc\u0105 zacisku zawieszenia w po\u0142\u0105czeniu z izolatorami linii napowietrznej; zacisk uziemiaj\u0105cy pod\u0142\u0105czony do licznika iskiernika lub bezpo\u015brednio do ziemi; przestrze\u0144 instalacyjna musi spe\u0142nia\u0107 wymagania dotycz\u0105ce odleg\u0142o\u015bci pe\u0142zania.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Specjalne Warunki Operacyjne (Wymagana personalizacja)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wysoko\u015b\u0107 przekraczaj\u0105ca 2000 m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura otoczenia poza zakresem od -40\u00b0C do +90\u00b0C;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Silnie zanieczyszczone, mg\u0142a solna lub \u015brodowiska o agresywnym dzia\u0142aniu chemicznym;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Warunki silnego wiatru lub silnych wibracji;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Niestandardowe konfiguracje izolator\u00f3w lub specjalne wymagania dotycz\u0105ce obci\u0105\u017calno\u015bci pr\u0105dowej.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Instalacja i konserwacja<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Wymagania instalacyjne<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Przed instalacj\u0105 nale\u017cy sprawdzi\u0107 wygl\u0105d produktu: obudowa z gumy silikonowej musi by\u0107 wolna od p\u0119kni\u0119\u0107, uszkodze\u0144 i pustych przestrzeni; zaciski monta\u017cowe i uziemiaj\u0105ce musz\u0105 by\u0107 nienaruszone, bez korozji i deformacji.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clean the mounting terminal and the overhead line insulator string surface, removing grease, dust, and foreign matter to ensure the mating surfaces are dry and clean. Check the grounding resistance of the earthing system to confirm it meets requirements (\u22644\u03a9 for 35kV systems).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Przymocuj zacisk zawieszenia odgromnika do izolatora \u0142a\u0144cuchowego linii napowietrznej, pod\u0142\u0105cz zacisk uziemiaj\u0105cy do licznika odgromnika lub bezpo\u015brednio do ziemi i dokr\u0119\u0107 wszystkie po\u0142\u0105czenia z okre\u015blon\u0105 si\u0142\u0105. Po instalacji sprawd\u017a, czy odgromnik jest bezpieczny i prawid\u0142owo wyr\u00f3wnany.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po zako\u0144czeniu instalacji przeprowadzi\u0107 pr\u00f3b\u0119 rezystancji izolacji. Odgromnik mo\u017ce by\u0107 pod napi\u0119ciem dopiero po pomy\u015blnym przej\u015bciu tej pr\u00f3by.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Wymagania konserwacyjne<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Okresowo sprawdzaj wygl\u0105d produktu: obudowa z gumy silikonowej musi by\u0107 wolna od p\u0119kni\u0119\u0107, uszkodze\u0144, \u015blad\u00f3w wy\u0142adowa\u0144 i nagromadzonego zanieczyszczenia; po\u0142\u0105czenia zacisk\u00f3w monta\u017cowych i uziemiaj\u0105cych musz\u0105 by\u0107 mocne i nie poluzowane; po\u0142\u0105czenia systemu uziemienia musz\u0105 by\u0107 niezawodne i wolne od korozji.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okresowo testuj rezystancj\u0119 izolacji i pr\u0105d up\u0142ywu, aby zweryfikowa\u0107, czy parametry spe\u0142niaj\u0105 wymagania i aby wykry\u0107 potencjalne usterki w odpowiednim czasie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wyczy\u015b\u0107 powierzchni\u0119 produktu, aby usun\u0105\u0107 nagromadzony kurz i zanieczyszczenia, utrzymuj\u0105c powierzchni\u0119 gumy silikonowej such\u0105 i czyst\u0105, zapobiegaj\u0105c korozji spowodowanej przez t\u0142uszcz lub substancje chemiczne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">W przypadku zaobserwowania jakichkolwiek nieprawid\u0142owo\u015bci \u2013 w tym p\u0119kni\u0119\u0107, uszkodze\u0144, wy\u0142adowa\u0144 lub rezystancji izolacji przekraczaj\u0105cej okre\u015blone limity \u2013 nale\u017cy natychmiast wycofa\u0107 urz\u0105dzenie z eksploatacji i je wymieni\u0107. U\u017cywanie urz\u0105dzenia ze znanymi wadami jest surowo zabronione.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u015arodki ostro\u017cno\u015bci<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Instalacja, uruchomienie i konserwacja tego produktu musz\u0105 by\u0107 przeprowadzane wy\u0142\u0105cznie przez wykwalifikowanych elektryk\u00f3w posiadaj\u0105cych uprawnienia do prac w sieciach \u015bredniego napi\u0119cia. Obs\u0142uga przez osoby nieposiadaj\u0105ce odpowiednich kwalifikacji jest surowo zabroniona.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Produkt ten musi by\u0107 u\u017cywany w po\u0142\u0105czeniu z liniami napowietrznymi i izolatorami odpowiadaj\u0105cymi danemu poziomowi napi\u0119cia. Surowo zabrania si\u0119 stosowania niezgodnego sprz\u0119tu o r\u00f3\u017cnych poziomach napi\u0119cia lub specyfikacjach, poniewa\u017c mo\u017ce to prowadzi\u0107 do awarii ochrony i incydent\u00f3w bezpiecze\u0144stwa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nieautoryzowane demontowanie lub modyfikowanie tego produktu jest surowo zabronione; spowoduje to uniewa\u017cnienie gwarancji i gwarancji bezpiecze\u0144stwa. U\u017cywanie niedozwolonych narz\u0119dzi do si\u0142owego monta\u017cu lub demonta\u017cu element\u00f3w przy\u0142\u0105czeniowych jest surowo zabronione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podczas instalacji nale\u017cy uwa\u017ca\u0107, aby nie uszkodzi\u0107 obudowy z gumy silikonowej. Wszystkie punkty po\u0142\u0105cze\u0144 musz\u0105 by\u0107 dokr\u0119cone z okre\u015blon\u0105 si\u0142\u0105, aby zapobiec przegrzaniu lub wy\u0142adowaniu z powodu s\u0142abego kontaktu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podczas przechowywania produkt nale\u017cy trzyma\u0107 w suchym, przewiewnym i ch\u0142odnym miejscu, z dala od bezpo\u015bredniego \u015bwiat\u0142a s\u0142onecznego, wysokich temperatur, wilgoci i nacisku mechanicznego. Kontakt z ostrymi przedmiotami, kt\u00f3re mog\u0142yby uszkodzi\u0107 obudow\u0119 z gumy silikonowej, jest surowo zabroniony.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podczas eksploatacji rezystancja uziemienia systemu uziemiaj\u0105cego musi by\u0107 okresowo sprawdzana w celu zapewnienia niezawodnego uziemienia i zapobiegania awariom ochrony spowodowanym niewystarczaj\u0105cym uziemieniem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Oznaczenie modelu<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Identyfikator modelu<\/td><td>Znaczenie<\/td><\/tr><tr><td>HY(YH)<\/td><td>Oznaczenie serii dla odgromnik\u00f3w metalowo-tlenkowych w obudowach kompozytowych<\/td><\/tr><tr><td>5<\/td><td>Nominal discharge current class (5kA)<\/td><\/tr><tr><td>W<\/td><td>Oznaczenie konstrukcji bezszwowej<\/td><\/tr><tr><td>S\/X<\/td><td>Oznaczenie typu linii \/ typu zawieszenia<\/td><\/tr><tr><td>35kV<\/td><td>Napi\u0119cie znamionowe systemu, napowietrzny system dystrybucyjny 35kV<\/td><\/tr><tr><td>51\/134, 54\/142<\/td><td>Napi\u0119cie znamionowe ogranicznika \/ napi\u0119cie szcz\u0105tkowe udaru piorunowego (warto\u015b\u0107 szczytowa)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Stosowane normy i certyfikaty<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Norma mi\u0119dzynarodowa: IEC 60099-4 Ograniczniki przepi\u0119\u0107 \u2014 Cz\u0119\u015b\u0107 4: Ograniczniki przepi\u0119\u0107 tlenkowych bez szczelin dla system\u00f3w pr\u0105du przemiennego;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Normy krajowe: GB 11032 Beziskrowe metalowo-tlenkowe ograniczniki przepi\u0119\u0107 pr\u0105du przemiennego, DL\/T 804 Wytyczne dotycz\u0105ce stosowania metalowo-tlenkowych ogranicznik\u00f3w przepi\u0119\u0107 w systemach elektroenergetycznych pr\u0105du przemiennego;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Produkt przeszed\u0142 testy typu przeprowadzone przez Krajowe Centrum Nadzoru i Inspekcji Jako\u015bci Wysokonapi\u0119ciowego Sprz\u0119tu Elektrycznego i jest zgodny z krajowymi normami przemys\u0142u energetycznego.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Obs\u0142uga posprzeda\u017cna<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Okres gwarancji na produkt: 18 miesi\u0119cy od daty produkcji lub 12 miesi\u0119cy od daty uruchomienia, w zale\u017cno\u015bci od tego, co nast\u0105pi wcze\u015bniej;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Produkty z wadami jako\u015bciowymi b\u0119d\u0105 naprawiane lub wymieniane bezp\u0142atnie w okresie gwarancyjnym;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dost\u0119pne s\u0105 us\u0142ugi wsparcia technicznego, wskaz\u00f3wki dotycz\u0105ce instalacji oraz us\u0142ugi dostosowywania (specjalne specyfikacje i adaptacje do specjalnych warunk\u00f3w pracy).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zawiadomienie o dokumencie<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Parametry techniczne zawarte w niniejszej instrukcji opieraj\u0105 si\u0119 na standardowych warunkach pracy. Specjalne warunki pracy wymagaj\u0105 dostosowania do rzeczywistych potrzeb. Umowa techniczna produktu i protok\u00f3\u0142 z bada\u0144 typu stanowi\u0105 ostateczne odniesienie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Za\u0142\u0105cznik: Schemat pogl\u0105dowy produktu<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"318\" height=\"405\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/HY5WS-35kV-1.png\" alt=\"Odgromnik wisz\u0105cy linii 35kV\" class=\"wp-image-998\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/HY5WS-35kV-1.png 318w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/HY5WS-35kV-1-236x300.png 236w\" sizes=\"(max-width: 318px) 100vw, 318px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>35kV Line-Suspended Surge Arrester Product Overview 35kV line suspension arrester (Model HY(YH)5WS-51\/134, HY(YH)5WX-54\/142) is a gapless metal oxide surge arrester [&hellip;]<\/p>\n","protected":false},"featured_media":997,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[16],"class_list":["post-1551","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-lightning-arrester-series"],"acf":{"products_imagines":[997,998,999],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/products\/1551","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/media\/999"},{"embeddable":true,"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/media\/998"},{"embeddable":true,"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/media\/997"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/media\/997"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/media?parent=1551"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/product_category?post=1551"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}