{"id":416,"date":"2026-01-23T06:53:21","date_gmt":"2026-01-23T06:53:21","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=416"},"modified":"2026-09-10T01:32:51","modified_gmt":"2026-09-10T01:32:51","slug":"eco-integrated-node-switchgear-quick-connectors","status":"publish","type":"products","link":"https:\/\/yieou.com\/pl\/product\/eco-integrated-node-switchgear-quick-connectors\/","title":{"rendered":"Szybkoz\u0142\u0105czki do rozdzielnic zintegrowanych ekologicznie 15kV"},"content":{"rendered":"<p class=\"wp-block-paragraph\">15kV Ekologiczny W\u0119ze\u0142 Zintegrowany <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">Rozdzielnica<\/a> Szybkoz\u0142\u0105czki<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Przegl\u0105d produktu<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/pl\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">The 15kV Eco-Integrated Node Switchgear Quick Connectors<\/a> are dedicated quick-connection devices designed specifically for 10kV\/15kV eco-friendly gas (nitrogen\/dry air) insulated integrated node switchgear. They enable rapid mating between switchgear and bypass cables\/transfer equipment, supporting live-line bypass operations, emergency power supply, and other scenarios where energized switchgear interface connections must be made without de-energization. These connectors are core accessory components for live-line operations on eco-friendly medium-voltage switchgear.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Cechy produktu<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Wydajno\u015b\u0107 elektryczna i izolacyjna<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Employing an insulation structure design dedicated to eco-friendly switchgear, compatible with nitrogen\/dry air insulating environments, the <a href=\"https:\/\/en.wikipedia.org\/wiki\/Quick_connect_fitting\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Quick_connect_fitting\" target=\"_blank\" rel=\"noopener\">\u0142\u0105czniki<\/a> exhibit excellent insulation performance. They can withstand the rated system voltage of 15kV as well as transient overvoltages, meeting the operational requirements of a maximum working voltage of 17.5kV, with partial discharge level \u226410pC (at 1.5U\u2080).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wbudowany wewn\u0119trzny rdze\u0144 przewodz\u0105cy z miedzi o wysokiej czysto\u015bci zapewnia wyj\u0105tkow\u0105 przewodno\u015b\u0107 elektryczn\u0105 i niezwykle niski op\u00f3r styku, zdolny do przenoszenia pr\u0105d\u00f3w znamionowych 250A\/630A bez nagrzewania lub utleniania podczas d\u0142ugotrwa\u0142ej pracy, spe\u0142niaj\u0105c wymagania zasilaczy awaryjnych o du\u017cym nat\u0119\u017ceniu pr\u0105du.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zintegrowana struktura optymalizacji pola elektrycznego i tarcze izolacyjne r\u00f3wnomiernie rozk\u0142adaj\u0105 pole elektryczne na styku i skutecznie t\u0142umi\u0105 wy\u0142adowania niezupe\u0142ne. Z\u0142\u0105cza zapewniaj\u0105 r\u00f3wnie\u017c doskona\u0142\u0105 szczelno\u015b\u0107 gazow\u0105, zapobiegaj\u0105c wyciekom przyjaznego dla \u015brodowiska gazu ze stacji rozdzielczych, bez ryzyka erozji elektrycznej lub przebicia dielektrycznego podczas d\u0142ugotrwa\u0142ej pracy, zapewniaj\u0105c stabiln\u0105 i niezawodn\u0105 wydajno\u015b\u0107 elektryczn\u0105 i uszczelniaj\u0105c\u0105.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cechy konstrukcyjne i bezpiecze\u0144stwa<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Standaryzowany projekt interfejsu \u015bci\u015ble przestrzega norm bran\u017cowych dla przyjaznych dla \u015brodowiska zintegrowanych rozdzielnic zespolonych i jest uniwersalnie wymienny z dedykowanymi interfejsami g\u0142\u00f3wnych przyjaznych dla \u015brodowiska rozdzielnic gazowych 15kV, oferuj\u0105c siln\u0105 kompatybilno\u015b\u0107.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Monolityczna konstrukcja modu\u0142owa zawiera mechanizm szybkiego blokowania, kt\u00f3ry nie wymaga dodatkowych narz\u0119dzi, umo\u017cliwiaj\u0105c szybkie \u0142\u0105czenie urz\u0105dze\u0144 rozdzielczych i obej\u015bciowych oraz znacz\u0105co skracaj\u0105c cykl budowy prac pod napi\u0119ciem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dwufunkcyjna konstrukcja integruje samopozycjonuj\u0105ce zabezpieczenie przed wysuni\u0119ciem oraz uszczelnienie gazowe. Po ca\u0142kowitym zainstalowaniu interfejsu mechanizm automatycznie blokuje si\u0119, jednocze\u015bnie zapewniaj\u0105c skuteczne uszczelnienie ekologicznego gazu wewn\u0105trz rozdzielnicy, zapobiegaj\u0105c luzowaniu si\u0119, przesuni\u0119ciu i wyciekom gazu podczas pracy, co zwi\u0119ksza bezpiecze\u0144stwo systemu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pe\u0142na ochrona izolacyjna zapewnia wysok\u0105 wytrzyma\u0142o\u015b\u0107 izolacji zewn\u0119trznej, umo\u017cliwiaj\u0105c bezpo\u015bredni kontakt z obudow\u0105 podczas pracy pod napi\u0119ciem bez ryzyka pora\u017cenia pr\u0105dem, co gwarantuje bezpiecze\u0144stwo personelu obs\u0142uguj\u0105cego i konserwuj\u0105cego.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Odporno\u015b\u0107 na czynniki \u015brodowiskowe i pogodowe<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Doskona\u0142a odporno\u015b\u0107 na warunki atmosferyczne umo\u017cliwia adaptacj\u0119 do szerokiego zakresu temperatur od -40\u00b0C do +90\u00b0C. Przewodz\u0105cy rdze\u0144 wewn\u0119trzny i elementy izolacyjne nie wykazuj\u0105 degradacji, p\u0119kania ani krucho\u015bci w ekstremalnych temperaturach, co czyni z\u0142\u0105cza odpowiednimi do ekologicznych rozdzielnic zar\u00f3wno wewn\u0105trz, jak i na zewn\u0105trz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Odporne na wilgo\u0107, wodoodporne, odporne na zanieczyszczenia i mg\u0142\u0119 soln\u0105 ze stopniem ochrony IP67, z\u0142\u0105cza dzia\u0142aj\u0105 niezawodnie przez d\u0142ugi czas w trudnych warunkach, takich jak wilgotna, zapylona i s\u0142ona atmosfera, bez podatno\u015bci na korozj\u0119 spowodowan\u0105 deszczem lub kondensacj\u0105. S\u0105 jednocze\u015bnie kompatybilne ze \u015brodowiskami izolowanymi azotem\/suchym powietrzem, bez ryzyka wycieku gazu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">W\u0142a\u015bciwo\u015bci przeciwstarzeniowe i antykorozyjne zapewnia cynowanie\/srebrzenie wewn\u0119trznego rdzenia przewodz\u0105cego, zapobiegaj\u0105ce utlenianiu i korozji, podczas gdy elementy izolacyjne wykonane s\u0105 z materia\u0142\u00f3w odpornych na ekologiczne gazy. \u017bywotno\u015b\u0107 przekracza 10 lat przy bezobs\u0142ugowej pracy, redukuj\u0105c d\u0142ugoterminowe koszty eksploatacji i konserwacji.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cechy mechaniczne i kompatybilno\u015bci<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wysoka wytrzyma\u0142o\u015b\u0107 mechaniczna z odporno\u015bci\u0105 na uderzenia i wibracje pozwala z\u0142\u0105czom wytrzyma\u0107 napr\u0119\u017cenia mechaniczne napotykane podczas transportu, instalacji i eksploatacji, bez ryzyka deformacji lub uszkodzenia, co czyni je odpowiednimi do z\u0142o\u017conych warunk\u00f3w pracy w terenie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kompatybilne z dedykowanymi interfejsami ekologicznych rozdzielnic zintegrowanych 10kV\/15kV, pier\u015bcieniowych jednostek g\u0142\u00f3wnych izolowanych azotem, kompaktowych stacji transformatorowych izolowanych suchym powietrzem i podobnych urz\u0105dze\u0144, z\u0142\u0105cza oferuj\u0105 du\u017c\u0105 uniwersalno\u015b\u0107 i mog\u0105 by\u0107 stosowane w po\u0142\u0105czeniu z popularnymi kablami obej\u015bciowymi, kablami przej\u015bciowymi i urz\u0105dzeniami odga\u0142\u0119\u017anymi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Modu\u0142owa konstrukcja umo\u017cliwia wielokrotne wk\u0142adanie i wyjmowanie, zapewniaj\u0105c wygodn\u0105 konserwacj\u0119 i zmniejszaj\u0105c koszty inwestycji w sprz\u0119t do prac pod napi\u0119ciem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Parametry techniczne<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Kategoria parametr\u00f3w<\/td><td>Przedmiot<\/td><td>Specyfikacja<\/td><\/tr><tr><td>Znamionowe parametry elektryczne<\/td><td>Napi\u0119cie systemowe (Un)<\/td><td>10kV\/15kV<\/td><\/tr><tr><td><\/td><td>Napi\u0119cie znamionowe (Ue)<\/td><td>15 kV<\/td><\/tr><tr><td><\/td><td>Maksymalne napi\u0119cie pracy (Um)<\/td><td>17,5 kV<\/td><\/tr><tr><td><\/td><td>Cz\u0119stotliwo\u015b\u0107 znamionowa (fn)<\/td><td>50 Hz\/60 Hz<\/td><\/tr><tr><td><\/td><td>Napi\u0119cie probiercze cz\u0119stotliwo\u015bci sieciowej<\/td><td>42kV\/5min (test na sucho), bez przebicia, bez przeskok\u00f3w<\/td><\/tr><tr><td><\/td><td>Napi\u0119cie udarowe<\/td><td>95kV (szczytowe), bez przebicia, bez przeskok\u00f3w<\/td><\/tr><tr><td><\/td><td>Poziom wy\u0142adowa\u0144 niezupe\u0142nych<\/td><td>\u226410pC (przy 1,5U\u2080)<\/td><\/tr><tr><td><\/td><td>Pr\u0105d znamionowy<\/td><td>250A\/630A (do wyboru)<\/td><\/tr><tr><td><\/td><td>Znamionowy pr\u0105d zwarciowy<\/td><td>20kA\/2s, 25kA\/2s (wybieralne)<\/td><\/tr><tr><td><\/td><td>Rezystancja kontaktowa<\/td><td>\u226420\u03bc\u03a9<\/td><\/tr><tr><td>Parametry strukturalne i materia\u0142owe<\/td><td>Materia\u0142 korpusu g\u0142\u00f3wnego<\/td><td>Mied\u017a cynowana\/srebrzona (przewodz\u0105cy rdze\u0144 wewn\u0119trzny), ekologiczny materia\u0142 izolacyjny odporny na gaz (elementy izolacyjne), stal nierdzewna (mechanizm blokuj\u0105cy\/ko\u0142nierz)<\/td><\/tr><tr><td><\/td><td>Ocena ochrony<\/td><td>IP67<\/td><\/tr><tr><td><\/td><td>Standard interfejsu<\/td><td>Kompatybilny z dedykowanymi interfejsami przyjaznych dla \u015brodowiska zintegrowanych rozdzielnic z wy\u0142\u0105cznikami 15kV, zgodny ze standardami bran\u017cowymi<\/td><\/tr><tr><td><\/td><td>Kompatybilny sprz\u0119t<\/td><td>Przyjazne dla \u015brodowiska zintegrowane rozdzielnice s\u0142upowe 10kV\/15kV, rozdzielnice pier\u015bcieniowe izolowane azotem\/suchym powietrzem, kable obej\u015bciowe, kable prze\u0142\u0105czeniowe itp.<\/td><\/tr><tr><td><\/td><td>Wydajno\u015b\u0107 uszczelnienia<\/td><td>Kompatybilny ze \u015brodowiskami izolowanymi azotem\/suchym powietrzem; brak ryzyka wycieku gazu<\/td><\/tr><tr><td>Parametry \u015brodowiskowe<\/td><td>Wysoko\u015b\u0107 stosowania<\/td><td>\u22642000 m (dost\u0119pna personalizacja dla du\u017cych wysoko\u015bci)<\/td><\/tr><tr><td><\/td><td>Temperatura otoczenia<\/td><td>-40\u00b0C do +90\u00b0C (praca), -40\u00b0C do +70\u00b0C (przechowywanie)<\/td><\/tr><tr><td><\/td><td>Wilgotno\u015b\u0107 wzgl\u0119dna<\/td><td>\u2264100% (bez kondensacji)<\/td><\/tr><tr><td><\/td><td>Ocena sejsmiczna<\/td><td>Klasa 8<\/td><\/tr><tr><td>Stosowane normy<\/td><td><\/td><td>GB\/T 12706, DL\/T 1476 Przepisy bada\u0144 zapobiegawczych dla narz\u0119dzi i sprz\u0119tu elektrycznego, DL\/T 814 Terminal automatyki dystrybucyjnej, GB 3906 Rozdzielnice i aparatura sterownicza metalowo-uskokowe pr\u0105du przemiennego 3,6 kV ~ 40,5 kV<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Zakres zastosowania<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Napi\u0119cia znamionowe: systemy elektroenergetyczne \u015bredniego napi\u0119cia 10kV\/15kV AC, kompatybilne z ekologicznymi rozdzielnicami gazowymi o maksymalnym napi\u0119ciu pracy 17,5kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mo\u017cliwe scenariusze zastosowania:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Konserwacja pod napi\u0119ciem i modernizacja przyjaznych dla \u015brodowiska zintegrowanych rozdzielnic z\u0142\u0105czowych 10kV\/15kV oraz rozdzielnic pier\u015bcieniowych izolowanych azotem\/suchym powietrzem, umo\u017cliwiaj\u0105ca szybkie po\u0142\u0105czenie mi\u0119dzy rozdzielnic\u0105 a kablami obej\u015bciowymi w celu utworzenia tymczasowych obwod\u00f3w zasilania obej\u015bciowego;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Operacje obej\u015bcia pod napi\u0119ciem na miejskich sieciach dystrybucyjnych, ekologiczne rozdzielnice sieci dystrybucyjnych, systemy dystrybucyjne przedsi\u0119biorstw przemys\u0142owych i g\u00f3rniczych oraz ekologiczne urz\u0105dzenia rozdzielcze nowych \u017ar\u00f3de\u0142 energii (fotowoltaika\/energia wiatrowa) stacji podwy\u017cszaj\u0105cych napi\u0119cie;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zasilanie awaryjne i prace pod napi\u0119ciem przy ekologicznych rozdzielnicach w pomieszczeniach rozdzielczych wewn\u0119trznych\/zewn\u0119trznych, stacjach transformatorowych kompaktowych i podobnych instalacjach.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cel funkcjonalny: Zapewnienie izolacji i po\u0142\u0105czenia przewodz\u0105cego mi\u0119dzy przyjaznymi dla \u015brodowiska zintegrowanymi rozdzielnicami modu\u0142owymi a urz\u0105dzeniami do pracy w obej\u015bciu, przy jednoczesnym zachowaniu szczelno\u015bci azotu\/suchego powietrza wewn\u0105trz rozdzielnicy, oferuj\u0105c bezpieczne i niezawodne rozwi\u0105zanie po\u0142\u0105czeniowe dla operacji obej\u015bcia pod napi\u0119ciem na rozdzielnicach przyjaznych dla \u015brodowiska system\u00f3w dystrybucyjnych \u015bredniego napi\u0119cia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Warunki pracy<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Warunki normalnej pracy<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wysoko\u015b\u0107: \u22642000m<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura otoczenia: od -40\u00b0C do +90\u00b0C; temperatura pracy urz\u0105dzenia zgodna z odpowiednimi normami<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wilgotno\u015b\u0107 wzgl\u0119dna: \u2264100% (bez kondensacji)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Warunki \u015brodowiskowe: wolne od gaz\u00f3w korozyjnych, materia\u0142\u00f3w \u0142atwopalnych\/wybuchowych oraz silnych wibracji lub wstrz\u0105s\u00f3w<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Metoda instalacji: Monta\u017c ko\u0142nierzowy do ekologicznego interfejsu rozdzielnicy, z przeciwleg\u0142ym ko\u0144cem bezpo\u015brednio pod\u0142\u0105czonym do interfejsu urz\u0105dzenia obej\u015bciowego. Dopuszczalne s\u0105 zar\u00f3wno poziome, jak i pionowe orientacje monta\u017cu; przestrze\u0144 instalacyjna musi uwzgl\u0119dnia\u0107 operacje pod\u0142\u0105czania\/od\u0142\u0105czania oraz wymagania monta\u017cu ko\u0142nierzowego.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Specjalne Warunki Operacyjne (Wymagana personalizacja)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wysoko\u015b\u0107 przekraczaj\u0105ca 2000 m<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura otoczenia poza zakresem od -40\u00b0C do +90\u00b0C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Silnie zanieczyszczone, s\u0142one lub chemicznie korozyjne \u015brodowiska<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Warunki pracy o wysokim poziomie wibracji lub du\u017cym obci\u0105\u017ceniu udarowym<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Niestandardowe konfiguracje interfejsu lub specjalne wymagania dotycz\u0105ce pr\u0105du<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Instalacja i konserwacja<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Wymagania instalacyjne<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Przed instalacj\u0105 nale\u017cy sprawdzi\u0107 wygl\u0105d produktu pod k\u0105tem p\u0119kni\u0119\u0107, uszkodze\u0144 i pustek; upewni\u0107 si\u0119, \u017ce elementy izolacyjne nie s\u0105 uszkodzone. Sprawdzi\u0107, czy przewodz\u0105cy rdze\u0144 wewn\u0119trzny, mechanizm blokuj\u0105cy i elementy uszczelniaj\u0105ce s\u0105 wolne od rdzy i deformacji, czy mechanizm blokuj\u0105cy dzia\u0142a p\u0142ynnie i niezawodnie, a elementy uszczelniaj\u0105ce nie wykazuj\u0105 oznak starzenia ani pogorszenia stanu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clean the inner surface of the eco-friendly switchgear interface and the <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" target=\"_blank\" rel=\"noopener\">z\u0142\u0105cze<\/a> surface, removing grease, dust, and foreign matter, and ensure the interface is dry and clean. Clean the bypass equipment interface surface, removing grease, dust, and foreign matter, and ensure the interface is dry and clean.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Na\u0142\u00f3\u017c r\u00f3wnomiern\u0105 warstw\u0119 dedykowanego smaru silikonowego na zewn\u0119trzn\u0105 powierzchni\u0119 styku z\u0142\u0105cza, aby zapobiec uszkodzeniu warstwy izolacyjnej i element\u00f3w uszczelniaj\u0105cych podczas monta\u017cu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zabezpiecz z\u0142\u0105cze do przyjaznego dla \u015brodowiska interfejsu rozdzielnicy za pomoc\u0105 ko\u0142nierza, dokr\u0119caj\u0105c \u015bruby z okre\u015blon\u0105 si\u0142\u0105. Niezawodnie pod\u0142\u0105cz przeciwleg\u0142y koniec z\u0142\u0105cza do interfejsu urz\u0105dzenia obej\u015bciowego, upewniaj\u0105c si\u0119 o pe\u0142nym osadzeniu, a nast\u0119pnie w\u0142\u0105cz mechanizm blokuj\u0105cy zapobiegaj\u0105cy wycofaniu. Po instalacji sprawd\u017a, czy nie ma luz\u00f3w ani niewsp\u00f3\u0142osiowo\u015bci.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po zako\u0144czeniu instalacji nale\u017cy przeprowadzi\u0107 pomiar rezystancji izolacji, pr\u00f3b\u0119 napi\u0119ciow\u0105 cz\u0119stotliwo\u015bci\u0105 sieciow\u0105 oraz pr\u00f3b\u0119 szczelno\u015bci gazowej; urz\u0105dzenie mo\u017ce zosta\u0107 oddane do eksploatacji dopiero po pomy\u015blnym przej\u015bciu wszystkich pr\u00f3b.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Wymagania konserwacyjne<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Okresowo sprawdzaj wygl\u0105d produktu pod k\u0105tem p\u0119kni\u0119\u0107, uszkodze\u0144, \u015blad\u00f3w wy\u0142adowa\u0144 i nagromadzenia zanieczyszcze\u0144; upewnij si\u0119, \u017ce po\u0142\u0105czenia z interfejsem rozdzielnicy i interfejsem urz\u0105dzenia obej\u015bciowego s\u0105 pewne i nie ma luz\u00f3w; sprawd\u017a, czy \u015bruby ko\u0142nierzy nie wykazuj\u0105 luz\u00f3w ani korozji, a elementy uszczelniaj\u0105ce nie wykazuj\u0105 starzenia ani pogorszenia stanu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okresowo testuj rezystancj\u0119 izolacji i rezystancj\u0119 stykow\u0105, a jednocze\u015bnie sprawdzaj ci\u015bnienie gazu wewn\u0105trz rozdzielnicy, aby zapewni\u0107 zgodno\u015b\u0107 parametr\u00f3w z wymaganiami i wykry\u0107 potencjalne usterki w odpowiednim czasie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wyczy\u015b\u0107 powierzchni\u0119 produktu i styki, usuwaj\u0105c kurz i zanieczyszczenia; utrzymuj powierzchnie izolacyjne w stanie suchym i czystym, unikaj\u0105c korozji spowodowanej przez t\u0142uszcz i substancje chemiczne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Je\u015bli produkt wykazuje anomalie, takie jak p\u0119kanie, uszkodzenie, wy\u0142adowanie, przegrzewanie, rezystancja styku poza specyfikacj\u0105 lub wyciek gazu, nale\u017cy go natychmiast wycofa\u0107 z eksploatacji i wymieni\u0107; eksploatacja wadliwej jednostki jest surowo zabroniona.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Operacje pod\u0142\u0105czania\/od\u0142\u0105czania interfejs\u00f3w musz\u0105 by\u0107 wykonywane za pomoc\u0105 dedykowanych narz\u0119dzi izolacyjnych; r\u0119czna obs\u0142uga pod napi\u0119ciem interfejs\u00f3w go\u0142ymi r\u0119kami jest surowo zabroniona, a podczas wszystkich operacji nale\u017cy \u015bci\u015ble przestrzega\u0107 przepis\u00f3w bezpiecze\u0144stwa dystrybucji.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u015arodki ostro\u017cno\u015bci<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Produkt musi by\u0107 instalowany, uruchamiany i konserwowany przez wykwalifikowanych elektryk\u00f3w posiadaj\u0105cych uprawnienia do pracy pod napi\u0119ciem w sieciach \u015bredniego napi\u0119cia; obs\u0142uga przez osoby nieposiadaj\u0105ce kwalifikacji jest surowo zabroniona.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Produkt musi by\u0107 u\u017cywany w po\u0142\u0105czeniu z przyjaznym dla \u015brodowiska osprz\u0119tem prze\u0142\u0105czaj\u0105cym i urz\u0105dzeniami do pracy obej\u015bciowej o odpowiednich specyfikacjach. U\u017cywanie z urz\u0105dzeniami o innych znamionowych napi\u0119ciach lub pr\u0105dach jest surowo zabronione, poniewa\u017c mo\u017ce to prowadzi\u0107 do awarii izolacji, incydent\u00f3w bezpiecze\u0144stwa lub wycieku gazu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nieautoryzowane rozbieranie lub modyfikowanie produktu jest zabronione i spowoduje utrat\u0119 gwarancji oraz certyfikatu bezpiecze\u0144stwa. U\u017cywanie niededykowanych narz\u0119dzi do si\u0142owego monta\u017cu lub demonta\u017cu z\u0142\u0105czy i ko\u0142nierzy jest surowo zabronione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podczas instalacji surowo zabrania si\u0119 uszkadzania powierzchni izolacyjnych i element\u00f3w uszczelniaj\u0105cych. Smar silikonowy musi by\u0107 na\u0142o\u017cony r\u00f3wnomiernie, aby nie pogorszy\u0107 parametr\u00f3w izolacji i skuteczno\u015bci uszczelnienia. \u015aruby mocuj\u0105ce ko\u0142nierz musz\u0105 by\u0107 dokr\u0119cone z okre\u015blon\u0105 si\u0142\u0105, aby zapobiec poluzowaniu, kt\u00f3re mog\u0142oby prowadzi\u0107 do przemieszczenia zacisk\u00f3w, rozlu\u017anienia styku lub wycieku gazu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podczas przechowywania produkt nale\u017cy trzyma\u0107 w suchym, przewiewnym i ch\u0142odnym miejscu, chroni\u0107 przed bezpo\u015brednim dzia\u0142aniem promieni s\u0142onecznych, wysok\u0105 temperatur\u0105, wilgoci\u0105 i \u015bciskaniem. Kategorycznie zabrania si\u0119 kontaktu z ostrymi przedmiotami, kt\u00f3re mog\u0142yby uszkodzi\u0107 elementy izolacyjne i uszczelniaj\u0105ce.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podczas wykonywania operacji pod\u0142\u0105czania\/od\u0142\u0105czania na aktywnych interfejsach nale\u017cy \u015bci\u015ble przestrzega\u0107 przepis\u00f3w bezpiecze\u0144stwa dystrybucji, wdro\u017cy\u0107 odpowiednie \u015brodki ochrony bezpiecze\u0144stwa i surowo zabrania si\u0119 nieautoryzowanych operacji.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Oznaczenie modelu<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Identyfikator modelu<\/th><th>Opis<\/th><\/tr><\/thead><tbody><tr><td>15 kV<\/td><td>Napi\u0119cie znamionowe systemu; napi\u0119cie znamionowe 15kV, maksymalne napi\u0119cie robocze 17,5kV<\/td><\/tr><tr><td>Szybkoz\u0142\u0105czki do rozdzielnic zintegrowanych z ekologicznych w\u0119z\u0142\u00f3w<\/td><td>Szybkoz\u0142\u0105czki do ekologicznych rozdzielnic zintegrowanych, stosowane do szybkiego \u0142\u0105czenia ekologicznych rozdzielnic gazowych z urz\u0105dzeniami do pracy obej\u015bciowej<\/td><\/tr><tr><td>250A\/630A<\/td><td>Pr\u0105d znamionowy; kompatybilny odpowiednio z obci\u0105\u017ceniami pr\u0105dowymi 250A\/630A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Stosowane normy i certyfikaty<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Normy mi\u0119dzynarodowe: IEC 60840 Kable zasilaj\u0105ce z izolacj\u0105 ekstrudowan\u0105 i ich akcesoria dla napi\u0119\u0107 znamionowych powy\u017cej 30 kV (Um=36 kV) do 150 kV (Um=170 kV \u2014 Metody bada\u0144 i wymagania; IEC 62271-200 Rozdzielnice i urz\u0105dzenia sterownicze wysokonapi\u0119ciowe \u2014 Cz\u0119\u015b\u0107 200: Metalowe rozdzielnice i urz\u0105dzenia sterownicze pr\u0105du przemiennego dla napi\u0119\u0107 znamionowych powy\u017cej 1 kV i do 52 kV w\u0142\u0105cznie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Normy krajowe: GB\/T 12706 Kable zasilaj\u0105ce z izolacj\u0105 wyt\u0142aczan\u0105 i ich akcesoria dla napi\u0119\u0107 znamionowych od 1 kV (Um=1,2 kV) do 35 kV (Um=40,5 kV); GB 3906 Rozdzielnice i urz\u0105dzenia sterownicze metalowo-obudowane pr\u0105du przemiennego 3,6 kV\u201340,5 kV; DL\/T 1476 Przepisy bada\u0144 zapobiegawczych dla narz\u0119dzi i urz\u0105dze\u0144 bezpiecze\u0144stwa elektrycznego.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Produkt przeszed\u0142 badania typu przeprowadzone przez Krajowe Centrum Nadzoru i Kontroli Jako\u015bci Wysokonapi\u0119ciowego Sprz\u0119tu Elektrycznego i jest zgodny z krajowymi normami przemys\u0142u energetycznego.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Obs\u0142uga posprzeda\u017cna<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Okres gwarancji na produkt: 18 miesi\u0119cy od daty produkcji lub 12 miesi\u0119cy od daty uruchomienia, w zale\u017cno\u015bci od tego, co nast\u0105pi wcze\u015bniej.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">W okresie gwarancji produkty z wadami jako\u015bciowymi s\u0105 naprawiane lub wymieniane bezp\u0142atnie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zapewniamy wsparcie techniczne, pomoc w instalacji oraz us\u0142ugi dostosowania (specjalne specyfikacje i adaptacje do specjalnych warunk\u00f3w pracy).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Informacja o dokumentacji<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Parametry techniczne zawarte w niniejszej instrukcji opieraj\u0105 si\u0119 na standardowych warunkach pracy. Specjalne warunki pracy wymagaj\u0105 dostosowania do rzeczywistych potrzeb. Umowa techniczna produktu i protok\u00f3\u0142 z bada\u0144 typu stanowi\u0105 ostateczne, wi\u0105\u017c\u0105ce odniesienie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Za\u0142\u0105cznik: Schemat pogl\u0105dowy produktu<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"440\" height=\"461\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/15kV-Eco-Integrated-Node-Switchgear-Quick-Connectors.png\" alt=\"15kV-Eco-Integrated-Node-Switchgear-Quick-Connectors\" class=\"wp-image-418\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/15kV-Eco-Integrated-Node-Switchgear-Quick-Connectors.png 440w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/15kV-Eco-Integrated-Node-Switchgear-Quick-Connectors-286x300.png 286w\" sizes=\"(max-width: 440px) 100vw, 440px\" \/><\/figure>\n\n\n\n<p class=\"sg-ai-highlighted-block wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>15kV Eco-Integrated Node Switchgear Quick Connectors Product Overview The 15kV Eco-Integrated Node Switchgear Quick Connectors are dedicated quick-connection devices designed [&hellip;]<\/p>\n","protected":false},"featured_media":418,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[13],"class_list":["post-416","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-quick-plug-series"],"acf":{"products_imagines":[418],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/products\/416","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/media\/418"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/media\/418"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/media?parent=416"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/pl\/wp-json\/wp\/v2\/product_category?post=416"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}