Product Overview
The JY PT-15/200A PT Connector, also known as an elbow connector, is a fully-shielded separable cable connector designed for 15kV (compatible with 10kV systems) voltage transformer (PT) or transformer terminations rated at 200A. Manufactured using EPDM rubber integral injection molding, it features fully-insulated, fully-sealed, and touchsafe construction. It is primarily used for connecting voltage transformers and power transformers in European-style ring main units and cable branch boxes, providing safe and reliable electrical connections and protection for power distribution systems.
Product Features
Insulation and Electrical Performance
Manufactured from premium EPDM rubber by integral injection molding, the connector offers excellent insulation performance capable of withstanding the operating voltage of 15kV systems. Power frequency withstand voltage and impulse withstand voltage performance comply with industry standards, ensuring safe electrical connections.
Built-in semiconducting shielding layer provides uniform electric field distribution, eliminates partial discharge risk caused by electric field concentration, and enhances long-term operational reliability.
Fully-sealed construction with IP67 protection rating effectively prevents ingress of moisture, dust, and oil, making it suitable for harsh environments such as high humidity and heavy dust conditions, ensuring stable electrical connections.
Installation and Construction Features
Separable plug-in design enables convenient installation without special tools. Direct connection to equipment via standardized interfaces allows fast construction, significantly reducing installation time and lowering construction costs.
Standardized interface is compatible with 15kV/200A European-style distribution equipment, voltage transformers, and power transformers, offering strong universality and good interchangeability for easy equipment maintenance and capacity expansion.
Fully-insulated, touchsafe construction ensures the connector surface is at ground potential after installation, with no exposed live parts, eliminating the need for additional insulation protection and ensuring the safety of operations and maintenance personnel.
Environmental and Weather Resistance
Excellent weatherability accommodates a wide operating temperature range of -40°C to +90°C. Rubber elasticity and insulation performance show no degradation at high or low temperatures, with no risk of cracking, embrittlement, or deformation, making it suitable for both indoor and outdoor applications.
Anti-aging, UV-resistant, and ozone-resistant, with a service life exceeding 20 years. Maintenance-free operation reduces long-term operations and maintenance costs.
Chemical corrosion resistance allows use in harsh environments including high humidity, heavy dust, salt fog, and mild acid-alkali conditions, with no risk of corrosion or degradation, suitable for industrial and mining enterprises and coastal regions.
Mechanical and Safety Features
High mechanical strength of the rubber material provides tear and tensile resistance, capable of withstanding mechanical stresses during construction and operation without risk of damage or cracking.
Designed with anti-misoperation and electric shock protection features. Automatic grounding upon full installation ensures a touchsafe connector surface with high safety, suitable for distribution scenarios with frequent personnel contact.
Compact structure and small form factor accommodate installation in confined spaces without spatial constraints.
Technical Parameters
| Parameter Category | Item | Technical Specification |
| Electrical Parameters | Applicable System Voltage | 15kV AC (compatible with 10kV distribution systems) |
| | Rated Current | 200A | |
| | Power Frequency Withstand Voltage (5 min) | 42kV, no breakdown | |
| | Impulse Withstand Voltage (peak) | 95kV, no breakdown | |
| | Insulation Resistance | ≥1000MΩ | |
| | Partial Discharge Level | ≤5pC (at 1.5 times rated voltage) | |
| Structural and Material Parameters | Body Material | Ethylene Propylene Diene Monomer rubber (EPDM) |
| | Applicable Cable Cross-Section | 16mm² to 95mm² (select by specification) | |
| | Protection Rating | IP67 | |
| | Construction Type | Fully-shielded separable elbow-type (PT) connector | |
| Environmental Parameters | Applicable Altitude | ≤2000m (high-altitude customization available) |
| | Ambient Temperature | -40°C to +90°C (operating); -40°C to +70°C (storage) | |
| | Relative Humidity | ≤100% (non-condensing) | |
| | Seismic Rating | Grade 8 | |
| Applicable Standards | GB/T 12706, IEC 60840, GB/T 11022 Common specifications for high-voltage switchgear and controlgear standards |
Application Scope
Applicable voltage class: 15kV AC power systems (compatible with 10kV distribution systems).
Application scenarios:
Connection of voltage transformers (PT) in European-style ring main units and cable branch boxes;
Low-voltage side or metering circuit connections of compact substations and power transformers;
10kV cable distribution systems in urban distribution networks, industrial and mining enterprises, and commercial buildings;
Cable termination connections for various indoor and outdoor scenarios;
Distribution scenarios with frequent personnel contact where high safety requirements apply.
Functional purpose: Provides safe and reliable electrical connections for 15kV/200A voltage transformers, power transformers, and European-style distribution equipment. With fully-insulated, fully-sealed, and touchsafe construction, it ensures safe and stable operation of power distribution systems and prevents safety incidents caused by insulation failure, inadequate sealing, or electric shock hazards.
Operating Conditions
Normal Operating Conditions
Altitude: ≤2000m;
Ambient temperature: -40°C to +90°C; cable operating temperature shall not exceed the conductor’s maximum continuous permissible operating temperature;
Relative humidity: ≤100% (non-condensing);
Environmental conditions: free from corrosive gases, flammable and explosive media, and severe vibration and shock;
Installation method: plug-in installation with direct connection to equipment via standardized interfaces; installation space must meet the connector’s minimum bending radius requirements.
Special Operating Conditions (Customization Required)
Altitude exceeding 2000m;
Ambient temperature outside the range of -40°C to +90°C;
Severe pollution, salt fog, or chemical corrosion environments;
High vibration or high shock duty;
Non-standard cable cross-sections or special protection class requirements.
Installation and Maintenance
Installation Requirements
Before installation, inspect the product appearance to confirm the connector is free of cracks, damage, and voids, and that all accessories are complete and undamaged.
Strip the cable in accordance with the process requirements; the strip length must comply with the connector specification. Avoid damaging the cable insulation during stripping. After stripping, clean the cable surface to remove oil, dust, and contaminants, ensuring the surface is dry and clean.
After crimping the cable conductor onto the terminal lug, insert it into the connector body and adjust the position to ensure reliable connection. Then insert the connector directly into the equipment interface and verify full engagement.
After installation, verify the connector connection is secure with no looseness or misalignment, and that the grounding connection is sound. Confirm everything is correct before completing installation.
Maintenance Requirements
Periodically inspect the connector appearance for cracks, damage, discharge marks, or contamination accumulation. Verify the connector is tightly seated on the equipment with no looseness or gaps.
Periodically test connector insulation resistance and contact resistance to ensure performance meets requirements and to identify potential defects in a timely manner.
Clean the connector surface to remove accumulated dust and contaminants, keeping the surface dry and clean, and preventing corrosion from oil or chemical substances.
If abnormalities such as cracks, damage, discharge, insulation resistance out of specification, or contact resistance out of specification are found, replace the connector immediately. Operation with known defects is strictly prohibited.
Precautions
The product must be installed, commissioned, and maintained by qualified personnel holding high-voltage electrical installation certifications. Operation by unqualified personnel is strictly prohibited.
The product must be used with 15kV/200A power cables, European-style distribution equipment, and voltage transformers of matching specifications. Mismatching cables or equipment of different specifications is strictly prohibited, as it will result in connection failure and safety incidents.
Unauthorized disassembly or modification of the product is prohibited; doing so will void the warranty and safety assurance. Forcible stretching or cutting of the connector is strictly prohibited to avoid damaging the rubber material.
During installation, cable stripping and terminal crimping must be performed in accordance with process requirements to avoid damaging the cable insulation. Ensure the connector is fully installed and the connection is reliable.
During storage, the product must be kept in a dry, ventilated, and cool environment, away from direct sunlight, high temperatures, moisture, and compression. Contact with sharp objects that may damage the connector is strictly prohibited.
During operation, periodically inspect the connector condition. Protect the connector from external mechanical force, compression, and impact to prevent damage or seal failure.
Model Designation
| Model Identifier | Meaning |
| JY | Manufacturer identifier (Jieyi) |
| PT | Product type identifier (Voltage Transformer / Elbow Connector) |
| 15 | Applicable system voltage class, 15kV (compatible with 10kV systems) |
| 200A | Rated current, 200A |
| PT Connector / Elbow Connector | Product type designation, fully-shielded separable elbow-type (PT) connector |
Applicable Standards and Certifications
International standard: IEC 60840 Test methods and requirements for power cables with extruded insulation and their accessories for rated voltages above 30kV (Um=36kV) up to 150kV (Um=170kV);
National standards: GB/T 12706 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV); GB/T 11022 Common specifications for high-voltage switchgear and controlgear standards;
The product has passed type testing by the National Wire and Cable Quality Supervision and Inspection Center and complies with national electric power industry standards.
After-Sales Service
Product warranty period: 18 months from the date of shipment, or 12 months from the date of commissioning, whichever comes first;
Free repair or replacement for product quality issues occurring within the warranty period;
Technical support, installation guidance, and customization services (special specifications and special duty adaptations) are available.
Document Notes
The technical parameters in this manual are based on standard operating conditions. Special operating conditions require customization according to actual requirements. The product technical agreement and type test report shall prevail as the final reference.
Appendix: Product Outline Drawing