{"id":1124,"date":"2026-01-29T02:08:36","date_gmt":"2026-01-29T02:08:36","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1124"},"modified":"2026-10-09T05:09:50","modified_gmt":"2026-10-09T05:09:50","slug":"wireless-temperature-measurement-device-series","status":"publish","type":"products","link":"https:\/\/yieou.com\/pt\/product\/wireless-temperature-measurement-device-series\/","title":{"rendered":"Dispositivo de Medi\u00e7\u00e3o de Temperatura Sem Fio S\u00e9rie"},"content":{"rendered":"<h3 class=\"wp-block-heading\">Vis\u00e3o Geral do Produto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dispositivo de Medi\u00e7\u00e3o de Temperatura Sem Fio S\u00e9rie refere-se a uma fam\u00edlia de produtos projetados para monitorar a temperatura em v\u00e1rios pontos sem a necessidade de fia\u00e7\u00e3o f\u00edsica entre o sensor e a unidade de coleta ou exibi\u00e7\u00e3o de dados. Esses sistemas s\u00e3o cruciais para o monitoramento de equipamentos el\u00e9tricos, processos industriais e condi\u00e7\u00f5es ambientais onde solu\u00e7\u00f5es com fio tradicionais s\u00e3o impratic\u00e1veis, inseguras ou muito caras.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Resumo do Produto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Short-circuit Alarm Indication: The short-circuit sensor detects the line current during operation and sends an alarm signal when a short-circuit fault occurs on the line and meets the short-circuit judgment criteria.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Grounding Alarm Indication: The grounding sensor detects the zero-sequence current of the line during operation and sends an alarm signal when a grounding fault occurs on the line and the grounding fault current exceeds the <strong>set alarm current value<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Over-temperature Alarm Indication: The temperature sensor detects the temperature of the cable near the cable head during operation and transmits the data to the host via optical fiber in a very short time. When the cable temperature reaches or exceeds the <strong>set alarm temperature value<\/strong>, the host sends an alarm signal and closes the contact.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The 2-in-1 sensor for temperature and current display monitors the temperature and current of the monitoring point during operation, and transmits the data to the host via optical fiber at a certain frequency. After receiving the signal, the host displays the data on the LCD screen (Realize page-up and page-down to check the current and temperature of each phase via operation and key pressing). (Current display is an <strong>optional function<\/strong>.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Two-remote Communication: After the indicator generates short-circuit and grounding alarm signals, it can output and transmit the fault status remotely via RS485 communication cable; in the fault-free state, the line load current and the temperature of the monitoring point are regularly reported to the upper computer via RS485 cable. (Optional function.)<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Par\u00e2metros T\u00e9cnicos<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Item<\/th><th>Par\u00e2metro<\/th><\/tr><\/thead><tbody><tr><td>Short-circuit Alarm<\/td><td>50~1000A (factory configurable), tolerance \u00b15%; factory setting: 600A<\/td><\/tr><tr><td>Short-circuit Overcurrent Response Time<\/td><td>0.03~5S (factory configurable); factory setting: 0.2S<\/td><\/tr><tr><td>Grounding Alarm<\/td><td>10~100A (factory configurable), tolerance \u00b110%; factory setting: 20A<\/td><\/tr><tr><td>Grounding Overcurrent Response Time<\/td><td>0.03~5S (factory configurable); factory setting: 0.2S<\/td><\/tr><tr><td>Over-temperature Alarm<\/td><td>20~80\u00b0C (field configurable), tolerance \u00b11\u00b0C; factory setting: 80\u00b0C<\/td><\/tr><tr><td>Auto-reset Time<\/td><td>7S~48h (factory configurable); factory setting: 8h<\/td><\/tr><tr><td>Standby Current of the Whole Unit<\/td><td>\u2264 5\u03bcA<\/td><\/tr><tr><td>Indicator Protection Class<\/td><td>Host IP40; Sensor IP65<\/td><\/tr><tr><td>Short-circuit &amp; Grounding Protection Contact Capacity<\/td><td>230V\/AC-0.1A, 30V\/DC-1A<\/td><\/tr><tr><td>Over-temperature Trip Contact Capacity<\/td><td>230V\/AC-0.1A, 30V\/DC-1A<\/td><\/tr><tr><td>Over-temperature Alarm<\/td><td>Relay output for 3 cycles (2S per cycle, set 750mS, reset 1250mS)<\/td><\/tr><tr><td>Maximum Withstand Current of Short-circuit Current Sensor<\/td><td>31.5kA\/4S<\/td><\/tr><tr><td>Ambiente Operacional<\/td><td>-25\u00b0C ~ +75\u00b0C; relative humidity: \u2264 95%; waterproof, acid-proof, salt-fog resistant<\/td><\/tr><tr><td>Escopo da Aplica\u00e7\u00e3o<\/td><td>In systems with voltage level below 20kV<\/td><\/tr><\/tbody><\/table><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview Wireless Temperature Measurement Device Series refers to a family of products designed to monitor temperature at various points [&hellip;]<\/p>\n","protected":false},"featured_media":1125,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[13],"class_list":["post-1124","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-quick-plug-series"],"acf":{"products_imagines":[1125],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/products\/1124","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/media\/1125"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/media\/1125"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/media?parent=1124"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/product_category?post=1124"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}