{"id":1625,"date":"2026-05-08T00:00:00","date_gmt":"2026-05-08T00:00:00","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1625"},"modified":"2026-09-15T02:41:02","modified_gmt":"2026-09-15T02:41:02","slug":"three-phase-three-wire-dry-type-metering-unit","status":"publish","type":"products","link":"https:\/\/yieou.com\/pt\/product\/three-phase-three-wire-dry-type-metering-unit\/","title":{"rendered":"Unidade de Medi\u00e7\u00e3o Trif\u00e1sica de Tr\u00eas Fios Tipo Seco JLSZV-6\/10"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Vis\u00e3o Geral do Produto<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/pt\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">Unidade de Medi\u00e7\u00e3o Trif\u00e1sica de Tr\u00eas Fios Tipo Seco JLSZV-6\/10<\/a> \u00e9 um dispositivo integrado de medi\u00e7\u00e3o de alta tens\u00e3o projetado para sistemas de energia CA de 6 kV e 10 kV, internos e externos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fabricada atrav\u00e9s de um processo de fundi\u00e7\u00e3o a v\u00e1cuo com resina ep\u00f3xi, a unidade integra transformadores de tens\u00e3o e transformadores de corrente num \u00fanico corpo fundido, permitindo a aquisi\u00e7\u00e3o simult\u00e2nea de sinais de tens\u00e3o e corrente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c9 usado principalmente para medi\u00e7\u00e3o de energia, monitoramento de par\u00e2metros el\u00e9tricos e gerenciamento de carga em sistemas de distribui\u00e7\u00e3o trif\u00e1sicos de tr\u00eas fios. As aplica\u00e7\u00f5es t\u00edpicas incluem linhas de distribui\u00e7\u00e3o de 6 kV e 10 kV, subesta\u00e7\u00f5es compactas, esta\u00e7\u00f5es de manobra, empresas industriais e de minera\u00e7\u00e3o, edif\u00edcios comerciais e outros sistemas de energia de m\u00e9dia tens\u00e3o.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Caracter\u00edsticas do Produto<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Isolamento e Desempenho El\u00e9trico<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Isolamento em resina fundida integrada:<\/strong><br>Os componentes dos transformadores de tens\u00e3o e corrente s\u00e3o formados integralmente utilizando um processo de fundi\u00e7\u00e3o a v\u00e1cuo com resina ep\u00f3xi. O isolamento s\u00f3lido n\u00e3o cont\u00e9m vazios de ar internos e proporciona excelente desempenho diel\u00e9trico.<\/li>\n\n\n\n<li><strong>Alta capacidade de suportar isolamento:<\/strong><br>A unidade pode suportar os requisitos especificados de tens\u00e3o de suportabilidade \u00e0 frequ\u00eancia industrial e a impulsos de raio do sistema correspondente de 6 kV ou 10 kV.<\/li>\n\n\n\n<li><strong>Baixa descarga parcial:<\/strong><br>A descarga parcial \u00e9 limitada a no m\u00e1ximo 10 pC, ajudando a reduzir o envelhecimento do isolamento e a melhorar a confiabilidade operacional a longo prazo.<\/li>\n\n\n\n<li><strong>Constru\u00e7\u00e3o a seco sem \u00f3leo:<\/strong><br>O produto n\u00e3o cont\u00e9m \u00f3leo isolante, eliminando os riscos de vazamento de \u00f3leo, contamina\u00e7\u00e3o por \u00f3leo e perigos de inc\u00eandio relacionados ao \u00f3leo. \u00c9 adequado para sistemas de distribui\u00e7\u00e3o de energia sem \u00f3leo, tanto internos quanto externos.<\/li>\n\n\n\n<li><strong>Aquisi\u00e7\u00e3o simult\u00e2nea de tens\u00e3o e corrente:<\/strong><br>A unidade integra transformadores de tens\u00e3o trif\u00e1sicos e transformadores de corrente bif\u00e1sicos de acordo com um arranjo de medi\u00e7\u00e3o trif\u00e1sico de tr\u00eas fios. Ela adquire simultaneamente sinais de tens\u00e3o trif\u00e1sica e corrente bif\u00e1sica para medi\u00e7\u00e3o de energia, c\u00e1lculo de pot\u00eancia e monitoramento de carga.<\/li>\n\n\n\n<li><strong>Ampla faixa de propor\u00e7\u00e3o:<\/strong><br>Rela\u00e7\u00f5es de tens\u00e3o como 6\/0,1 kV e 10\/0,1 kV est\u00e3o dispon\u00edveis. Rela\u00e7\u00f5es de corrente de 5\/5 A a 2.000\/5 A podem ser configuradas de acordo com os requisitos de carga.<\/li>\n\n\n\n<li><strong>Alta precis\u00e3o de medi\u00e7\u00e3o:<\/strong><br>Transformadores de corrente com classes de precis\u00e3o at\u00e9 0,2S e transformadores de tens\u00e3o com classes de precis\u00e3o at\u00e9 0,2 est\u00e3o dispon\u00edveis. As classes 0,5 e 1 tamb\u00e9m podem ser fornecidas de acordo com os requisitos de medi\u00e7\u00e3o ou monitoramento.<\/li>\n\n\n\n<li><strong>Resist\u00eancia a descargas disruptivas por alta polui\u00e7\u00e3o:<\/strong><br>O lado de alta tens\u00e3o apresenta uma estrutura de isolamento multi-escudo com uma dist\u00e2ncia de escoamento estendida. Isso melhora a resist\u00eancia \u00e0 descarga superficial em ambientes \u00famidos, polu\u00eddos e expostos ao ar livre.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Estrutura e Caracter\u00edsticas de Instala\u00e7\u00e3o<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Estrutura integrada a seco:<\/strong><br>O conjunto completo de medi\u00e7\u00e3o est\u00e1 encapsulado num \u00fanico corpo de resina fundida, sem componentes internos sob tens\u00e3o expostos.<\/li>\n\n\n\n<li><strong>Vers\u00f5es internas e externas:<\/strong><br>Os modelos externos oferecem um \u00edndice de prote\u00e7\u00e3o IP65, enquanto os modelos internos oferecem um \u00edndice de prote\u00e7\u00e3o IP20.<\/li>\n\n\n\n<li><strong>Constru\u00e7\u00e3o compacta:<\/strong><br>A integra\u00e7\u00e3o dos transformadores de tens\u00e3o e corrente em uma \u00fanica unidade reduz o n\u00famero de componentes separados, economiza espa\u00e7o de instala\u00e7\u00e3o e simplifica a fia\u00e7\u00e3o no local.<\/li>\n\n\n\n<li><strong>Projeto de medi\u00e7\u00e3o trif\u00e1sica a tr\u00eas fios:<\/strong><br>A unidade utiliza um arranjo de medi\u00e7\u00e3o de dois elementos adequado para sistemas trif\u00e1sicos de tr\u00eas fios, incluindo sistemas com neutros n\u00e3o efetivamente aterrados.<\/li>\n\n\n\n<li><strong>Conex\u00e3o direta ao medidor:<\/strong><br>Os circuitos secund\u00e1rios podem ser conectados diretamente a um medidor de energia trif\u00e1sico de tr\u00eas fios compat\u00edvel, sem a necessidade de transformadores de instrumento adicionais.<\/li>\n\n\n\n<li><strong>Terminais claramente identificados:<\/strong><br>O lado de alta tens\u00e3o utiliza terminais dedicados ou placas de terminais. Os terminais de tens\u00e3o e corrente secund\u00e1rias s\u00e3o claramente marcados e agrupados separadamente para reduzir o risco de fia\u00e7\u00e3o incorreta.<\/li>\n\n\n\n<li><strong>Instala\u00e7\u00e3o flex\u00edvel:<\/strong><br>A unidade suporta montagem em poste externo, interna <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a> instala\u00e7\u00e3o e instala\u00e7\u00e3o em subesta\u00e7\u00f5es tipo caixa.<\/li>\n\n\n\n<li><strong>Alta estabilidade mec\u00e2nica:<\/strong><br>A estrutura de montagem oferece resist\u00eancia confi\u00e1vel a cargas de vibra\u00e7\u00e3o e vento quando instalada corretamente.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Funcionalidades de Opera\u00e7\u00e3o e Manuten\u00e7\u00e3o<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Opera\u00e7\u00e3o de baixa manuten\u00e7\u00e3o:<\/strong><br>O design seco e isento de \u00f3leo elimina vazamentos de \u00f3leo, substitui\u00e7\u00e3o de \u00f3leo e riscos de inc\u00eandio relacionados ao \u00f3leo.<\/li>\n\n\n\n<li><strong>Alta resist\u00eancia mec\u00e2nica:<\/strong><br>O corpo moldado em resina ep\u00f3xi oferece resist\u00eancia confi\u00e1vel a impactos, envelhecimento e corros\u00e3o.<\/li>\n\n\n\n<li><strong>Ampla faixa de temperatura operacional:<\/strong><br>A unidade pode operar em temperaturas ambientes de -40\u00b0C a +70\u00b0C. A resina ep\u00f3xi mant\u00e9m propriedades isolantes e mec\u00e2nicas est\u00e1veis sob condi\u00e7\u00f5es de alta e baixa temperatura.<\/li>\n\n\n\n<li><strong>Resist\u00eancia \u00e0s intemp\u00e9ries ao ar livre:<\/strong><br>Modelos externos podem suportar luz solar normal, chuva, geada, exposi\u00e7\u00e3o ao vento e varia\u00e7\u00e3o de temperatura.<\/li>\n\n\n\n<li><strong>Alta confiabilidade operacional:<\/strong><br>Os componentes dos transformadores de tens\u00e3o e corrente utilizam n\u00facleos magn\u00e9ticos e materiais de enrolamento de alta qualidade, proporcionando baixas perdas operacionais, eleva\u00e7\u00e3o limitada de temperatura e precis\u00e3o de medi\u00e7\u00e3o est\u00e1vel.<\/li>\n\n\n\n<li><strong>Precis\u00e3o est\u00e1vel a longo prazo:<\/strong><br>O produto foi projetado para minimizar a deriva de precis\u00e3o durante a opera\u00e7\u00e3o a longo prazo.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Par\u00e2metros El\u00e9tricos<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Par\u00e2metro<\/th><th>Especifica\u00e7\u00e3o<\/th><\/tr><\/thead><tbody><tr><td>Tens\u00e3o de Sistema Aplic\u00e1vel<\/td><td>6 kV \/ 10 kV CA, U = 7,2 kV \/ 12 kV<\/td><\/tr><tr><td>Frequ\u00eancia Nominal<\/td><td>50 Hz<\/td><\/tr><tr><td>Rela\u00e7\u00e3o de Tens\u00e3o<\/td><td>6\/0,1 kV ou 10\/0,1 kV, personaliz\u00e1vel<\/td><\/tr><tr><td>\u00cdndice de Liquidez Corrente<\/td><td>5\/5 A a 2.000\/5 A, personaliz\u00e1vel<\/td><\/tr><tr><td>Classe de Precis\u00e3o de Transformador de Tens\u00e3o<\/td><td>Classe 0,2 \/ 0,5 \/ 1<\/td><\/tr><tr><td>Classe de Precis\u00e3o de Transformador de Corrente<\/td><td>Classe 0,2S \/ 0,5S \/ 0,5<\/td><\/tr><tr><td>Tens\u00e3o Suport\u00e1vel de Frequ\u00eancia de Rede<\/td><td>28 kV por 1 minuto para modelos de 6 kV; 42 kV por 1 minuto para modelos de 10 kV, sem ruptura<\/td><\/tr><tr><td>Tens\u00e3o de Suporte a Impulso de Descarga Atmosf\u00e9rica<\/td><td>60 kV de pico para modelos de 6 kV; 75 kV de pico para modelos de 10 kV, sem ruptura<\/td><\/tr><tr><td>Descarga Parcial<\/td><td>\u226410 pC<\/td><\/tr><tr><td>Resist\u00eancia de Isolamento<\/td><td>\u22651,000 M\u03a9 between high voltage, low voltage, and earth<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Par\u00e2metros Estruturais e de Materiais<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Par\u00e2metro<\/th><th>Especifica\u00e7\u00e3o<\/th><\/tr><\/thead><tbody><tr><td>Meio Isolante<\/td><td>Fundi\u00e7\u00e3o integrada de resina ep\u00f3xi<\/td><\/tr><tr><td>Classifica\u00e7\u00e3o de Prote\u00e7\u00e3o<\/td><td>IP65 para modelos externos; IP20 para modelos internos<\/td><\/tr><tr><td>Tipo de Instala\u00e7\u00e3o<\/td><td>Montagem em poste, instala\u00e7\u00e3o de pain\u00e9is el\u00e9tricos internos ou instala\u00e7\u00e3o de subesta\u00e7\u00f5es tipo caixa<\/td><\/tr><tr><td>Classe T\u00e9rmica<\/td><td>Classe B, 130\u00b0C<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Par\u00e2metros Ambientais<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Par\u00e2metro<\/th><th>Especifica\u00e7\u00e3o<\/th><\/tr><\/thead><tbody><tr><td>Altitude de Instala\u00e7\u00e3o<\/td><td>\u22642.000 m; vers\u00f5es de alta altitude dispon\u00edveis<\/td><\/tr><tr><td>Temperatura de Opera\u00e7\u00e3o<\/td><td>-40\u00b0C a +70\u00b0C<\/td><\/tr><tr><td>Temperatura de Armazenamento<\/td><td>-40\u00b0C a +85\u00b0C<\/td><\/tr><tr><td>Umidade Relativa<\/td><td>\u226495%, sem condensa\u00e7\u00e3o<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Normas Aplic\u00e1veis<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Padr\u00e3o<\/th><th>Descri\u00e7\u00e3o<\/th><\/tr><\/thead><tbody><tr><td>GB 1207<\/td><td>Transformadores de Tens\u00e3o<\/td><\/tr><tr><td>GB 1208<\/td><td>Transformadores atuais<\/td><\/tr><tr><td>GB\/T 17215<\/td><td>Equipamento de Medi\u00e7\u00e3o de Eletricidade<\/td><\/tr><tr><td>DL\/T 448<\/td><td>C\u00f3digo T\u00e9cnico Administrativo para Medi\u00e7\u00e3o de Energia El\u00e9trica<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Aplica\u00e7\u00f5es<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Sistemas de Energia Aplic\u00e1veis<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A Unidade de Medi\u00e7\u00e3o JLSZV-6\/10 \u00e9 adequada para sistemas de energia CA trif\u00e1sicos e de tr\u00eas fios de 6 kV e 10 kV com tens\u00f5es m\u00e1ximas de sistema de 7,2 kV e 12 kV.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Aplica\u00e7\u00f5es T\u00edpicas<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Medi\u00e7\u00e3o de energia em postes em linhas de distribui\u00e7\u00e3o externas<\/li>\n\n\n\n<li>Medi\u00e7\u00e3o de energia e monitoramento de carga em pain\u00e9is de m\u00e9dia tens\u00e3o internos<\/li>\n\n\n\n<li>Subesta\u00e7\u00f5es tipo caixa<\/li>\n\n\n\n<li>Esta\u00e7\u00f5es de comuta\u00e7\u00e3o e distribui\u00e7\u00e3o<\/li>\n\n\n\n<li>Sistemas de distribui\u00e7\u00e3o de 6 kV e 10 kV em empreendimentos industriais e de minera\u00e7\u00e3o<\/li>\n\n\n\n<li>Edif\u00edcios comerciais e parques industriais<\/li>\n\n\n\n<li>Aquisi\u00e7\u00e3o de dados de energia em sistemas de automa\u00e7\u00e3o de energia<\/li>\n\n\n\n<li>Sistemas de monitoramento, controle e gerenciamento de carga de energia<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Fun\u00e7\u00f5es Principais<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A unidade de medi\u00e7\u00e3o converte a alta tens\u00e3o do sistema e a corrente prim\u00e1ria em sinais secund\u00e1rios padronizados:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tens\u00e3o de sa\u00edda: 100 V<\/li>\n\n\n\n<li>Sa\u00edda atual: 5 A<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Estes sinais podem ser fornecidos a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Medidores de energia trif\u00e1sicos de tr\u00eas fios<\/li>\n\n\n\n<li>Instrumentos de medi\u00e7\u00e3o<\/li>\n\n\n\n<li>Equipamento de monitoramento de energia<\/li>\n\n\n\n<li>Sistemas de gerenciamento de carga<\/li>\n\n\n\n<li>Dispositivos de aquisi\u00e7\u00e3o de dados<\/li>\n\n\n\n<li>Sistemas de automa\u00e7\u00e3o de energia<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A unidade suporta:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Medi\u00e7\u00e3o de energia<\/li>\n\n\n\n<li>C\u00e1lculo de pot\u00eancia<\/li>\n\n\n\n<li>Monitoramento de carga<\/li>\n\n\n\n<li>Aquisi\u00e7\u00e3o de par\u00e2metros el\u00e9tricos<\/li>\n\n\n\n<li>An\u00e1lise de consumo<\/li>\n\n\n\n<li>Gest\u00e3o de energia<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ele tamb\u00e9m fornece isolamento el\u00e9trico entre o sistema de energia prim\u00e1rio e os circuitos de medi\u00e7\u00e3o secund\u00e1rios, ajudando a proteger o equipamento conectado e o pessoal operacional.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Condi\u00e7\u00f5es de Opera\u00e7\u00e3o<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Condi\u00e7\u00f5es Normais de Opera\u00e7\u00e3o<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Altitude de instala\u00e7\u00e3o: n\u00e3o superior a 2.000 m<\/li>\n\n\n\n<li>Temperatura ambiente: -40\u00b0C a +70\u00b0C<\/li>\n\n\n\n<li>Mudan\u00e7as severas ou repentinas de temperatura devem ser evitadas<\/li>\n\n\n\n<li>Umidade relativa: n\u00e3o mais que 95%, sem condensa\u00e7\u00e3o<\/li>\n\n\n\n<li>O ambiente deve estar livre de gases corrosivos.<\/li>\n\n\n\n<li>Subst\u00e2ncias inflam\u00e1veis ou explosivas n\u00e3o s\u00e3o permitidas<\/li>\n\n\n\n<li>Vibra\u00e7\u00f5es severas e impactos mec\u00e2nicos devem ser evitados<\/li>\n\n\n\n<li>Modelos externos podem suportar exposi\u00e7\u00e3o normal \u00e0 luz solar, chuva, geada e vento.<\/li>\n\n\n\n<li>Instala\u00e7\u00e3o de quadros el\u00e9tricos em postes externos ou em ambientes internos<\/li>\n\n\n\n<li>Ambientes com corros\u00e3o severa, n\u00e9voa salina ou tempestades de areia devem ser evitados, a menos que um modelo personalizado seja utilizado.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Condi\u00e7\u00f5es Operacionais Especiais<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Produtos personalizados s\u00e3o necess\u00e1rios para:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Altitudes de instala\u00e7\u00e3o acima de 2.000 m<\/li>\n\n\n\n<li>Temperaturas ambientes fora da faixa de -40\u00b0C a +70\u00b0C<\/li>\n\n\n\n<li>Polui\u00e7\u00e3o severa ou ambientes com n\u00e9voa salina<\/li>\n\n\n\n<li>Ambientes quimicamente corrosivos<\/li>\n\n\n\n<li>Vento forte ou condi\u00e7\u00f5es severas de areia e poeira<\/li>\n\n\n\n<li>Exposi\u00e7\u00e3o ultravioleta de alta intensidade<\/li>\n\n\n\n<li>Rela\u00e7\u00f5es de tens\u00e3o n\u00e3o padronizadas<\/li>\n\n\n\n<li>R\u00e1cios de corrente n\u00e3o standard<\/li>\n\n\n\n<li>Dimens\u00f5es especiais de montagem<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Instala\u00e7\u00e3o e Manuten\u00e7\u00e3o<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Requisitos de Instala\u00e7\u00e3o<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Inspe\u00e7\u00e3o pr\u00e9-instala\u00e7\u00e3o:<\/strong><br>Inspecione a unidade de medi\u00e7\u00e3o e confirme que o corpo de resina ep\u00f3xi est\u00e1 livre de rachaduras, bolhas, danos mec\u00e2nicos e outros defeitos vis\u00edveis. Verifique se todas as marca\u00e7\u00f5es dos terminais est\u00e3o claras e se os acess\u00f3rios fornecidos est\u00e3o completos. Verifique se o modelo, a rela\u00e7\u00e3o de tens\u00e3o, a rela\u00e7\u00e3o de corrente e as classes de precis\u00e3o correspondem ao projeto do sistema e aos requisitos de medi\u00e7\u00e3o.<\/li>\n\n\n\n<li><strong>Montagem:<\/strong><br>Selecione um suporte de montagem adequado de acordo com o m\u00e9todo de instala\u00e7\u00e3o. Fixe a unidade de medi\u00e7\u00e3o na posi\u00e7\u00e3o e confirme que n\u00e3o h\u00e1 folgas, deslocamentos ou cargas mec\u00e2nicas irregulares. A posi\u00e7\u00e3o de montagem pode ser horizontal ou vertical de acordo com o projeto do produto. Instala\u00e7\u00f5es em postes devem atender aos requisitos especificados de carga de vento e anti-tombo.<\/li>\n\n\n\n<li><strong>Conex\u00e3o do lado de alta tens\u00e3o:<\/strong><br>Conecte os terminais de alta tens\u00e3o de acordo com o projeto do sistema. Certifique-se de que todas as conex\u00f5es estejam firmemente apertadas e proporcionem contato el\u00e9trico confi\u00e1vel. Mantenha folga el\u00e9trica adequada entre os condutores de alta tens\u00e3o, componentes aterrados e outras partes energizadas. As conex\u00f5es de alta tens\u00e3o externas devem ser devidamente protegidas contra entrada de \u00e1gua e corros\u00e3o.<\/li>\n\n\n\n<li><strong>Conex\u00e3o do lado secund\u00e1rio:<\/strong><br>Conecte os terminais secund\u00e1rios de tens\u00e3o e corrente ao medidor de energia de acordo com suas marca\u00e7\u00f5es. O circuito secund\u00e1rio do transformador de corrente nunca deve ser deixado aberto enquanto o circuito prim\u00e1rio estiver energizado. O circuito secund\u00e1rio do transformador de tens\u00e3o nunca deve ser curto-circuitado. O circuito secund\u00e1rio de corrente exigido deve ser aterrado de forma confi\u00e1vel em um ponto, de acordo com o projeto do sistema e os requisitos aplic\u00e1veis de seguran\u00e7a el\u00e9trica.<\/li>\n\n\n\n<li><strong>Inspe\u00e7\u00e3o de isolamento:<\/strong><br>Ap\u00f3s a instala\u00e7\u00e3o, me\u00e7a a resist\u00eancia de isolamento entre:<ul><li>Alta tens\u00e3o e baixa tens\u00e3o<\/li><li>Alta tens\u00e3o e terra<\/li><li>Baixa tens\u00e3o e terra<\/li><\/ul>Confirme que os circuitos secund\u00e1rios de tens\u00e3o e corrente est\u00e3o corretamente conectados e livres de curtos-circuitos ou circuitos abertos n\u00e3o intencionais. Verifique a fia\u00e7\u00e3o do medidor de energia e a sequ\u00eancia de fases antes de energizar o sistema.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Requisitos de Manuten\u00e7\u00e3o<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Inspecione regularmente o corpo da resina ep\u00f3xi quanto a rachaduras, danos mec\u00e2nicos, marcas de descarga e contamina\u00e7\u00e3o.<\/li>\n\n\n\n<li>Verifique os terminais de alta tens\u00e3o quanto a folga, oxida\u00e7\u00e3o, corros\u00e3o ou aquecimento anormal.<\/li>\n\n\n\n<li>Para modelos externos, inspecione a impermeabiliza\u00e7\u00e3o dos terminais e a prote\u00e7\u00e3o contra corros\u00e3o.<\/li>\n\n\n\n<li>Verifique regularmente todas as conex\u00f5es de alta e baixa tens\u00e3o quanto a folgas, superaquecimento e descolora\u00e7\u00e3o.<\/li>\n\n\n\n<li>Confirme que o circuito secund\u00e1rio atual permanece corretamente conectado e com aterramento confi\u00e1vel.<\/li>\n\n\n\n<li>Verifique periodicamente a precis\u00e3o da medi\u00e7\u00e3o comparando as leituras do medidor de energia com os limites de erro especificados da unidade de medi\u00e7\u00e3o.<\/li>\n\n\n\n<li>Teste periodicamente a resist\u00eancia de isolamento e confirme que o desempenho do isolamento permanece dentro dos requisitos especificados.<\/li>\n\n\n\n<li>Limpe a poeira e a contamina\u00e7\u00e3o da superf\u00edcie da unidade de medi\u00e7\u00e3o.<\/li>\n\n\n\n<li>Para modelos externos, limpe regularmente os abrigos isolantes para reduzir o risco de flashover por polui\u00e7\u00e3o.<\/li>\n\n\n\n<li>Evite que \u00f3leo e subst\u00e2ncias corrosivas entrem em contato com o corpo da resina ep\u00f3xi.<\/li>\n\n\n\n<li>Se for detectada trinca, descarga el\u00e9trica, superaquecimento ou erro excessivo de medi\u00e7\u00e3o, desenergize e inspecione o equipamento imediatamente. Substitua a unidade onde for necess\u00e1rio.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Precau\u00e7\u00f5es<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>O circuito secund\u00e1rio do transformador de corrente nunca deve ser deixado aberto enquanto o sistema prim\u00e1rio estiver energizado. O circuito secund\u00e1rio do transformador de potencial nunca deve ser curto-circuitado. Qualquer uma das condi\u00e7\u00f5es pode produzir sobretens\u00e3o ou sobrecorrente perigosas e criar um risco s\u00e9rio para equipamentos e pessoal.<\/li>\n\n\n\n<li>Durante a manuten\u00e7\u00e3o, o circuito secund\u00e1rio atual deve ser firmemente curto-circuitado e aterrado antes da desconex\u00e3o. O circuito secund\u00e1rio de tens\u00e3o deve ser isolado com seguran\u00e7a antes do in\u00edcio dos trabalhos.<\/li>\n\n\n\n<li>Evite impacto ou colis\u00e3o com o corpo da resina ep\u00f3xi e os terminais de alta tens\u00e3o durante o transporte e a instala\u00e7\u00e3o. Danos mec\u00e2nicos podem reduzir o desempenho de isolamento e a resist\u00eancia \u00e0 polui\u00e7\u00e3o-arco el\u00e9trico.<\/li>\n\n\n\n<li>Utilize condutores isolados adequados para conex\u00f5es de alta tens\u00e3o. Mantenha folga el\u00e9trica adequada em rela\u00e7\u00e3o a componentes aterrados e outras partes energizadas para evitar descargas entre fases ou entre fase e terra.<\/li>\n\n\n\n<li>Confirme a sequ\u00eancia de fases correta durante a fia\u00e7\u00e3o trif\u00e1sica. Conex\u00f5es de fase incorretas podem afetar a precis\u00e3o da medi\u00e7\u00e3o e a opera\u00e7\u00e3o do sistema.<\/li>\n\n\n\n<li>O equipamento deve ser aterrado de forma confi\u00e1vel. O terminal de aterramento na base deve estar firmemente conectado ao aterramento. <a href=\"https:\/\/en.wikipedia.org\/wiki\/Busbar\" target=\"_blank\" rel=\"noopener\">barramento<\/a>.<\/li>\n\n\n\n<li>Os modelos externos devem cumprir os requisitos aplic\u00e1veis de prote\u00e7\u00e3o contra raios e aterramento.<\/li>\n\n\n\n<li>Armazene o produto em ambiente seco, ventilado e sombreado. Evite luz solar direta, altas temperaturas, umidade, compress\u00e3o e impacto mec\u00e2nico.<\/li>\n\n\n\n<li>A instala\u00e7\u00e3o, a coloca\u00e7\u00e3o em funcionamento e a manuten\u00e7\u00e3o devem ser realizadas por pessoal el\u00e9trico qualificado, de acordo com os procedimentos de seguran\u00e7a el\u00e9trica aplic\u00e1veis.<\/li>\n\n\n\n<li>A unidade de medi\u00e7\u00e3o deve passar por verifica\u00e7\u00e3o pela autoridade metrol\u00f3gica local competente antes de ser colocada em servi\u00e7o, onde tal verifica\u00e7\u00e3o for exigida.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Lista de Suprimentos Padr\u00e3o<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>N\u00e3o.<\/th><th>Item<\/th><th>Fun\u00e7\u00e3o<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Unidade de Medi\u00e7\u00e3o Trif\u00e1sica de Tr\u00eas Fios Tipo Seco JLSZV-6\/10<\/td><td>Dispositivo principal para transforma\u00e7\u00e3o de tens\u00e3o e corrente, isolamento el\u00e9trico e medi\u00e7\u00e3o de energia<\/td><\/tr><tr><td>2<\/td><td>Suportes de Montagem, Parafusos e Arruelas<\/td><td>Usado para fixar a unidade de medi\u00e7\u00e3o durante a instala\u00e7\u00e3o<\/td><\/tr><tr><td>3<\/td><td>Tampa do Terminal Secund\u00e1rio<\/td><td>Protege os terminais de baixa tens\u00e3o e ajuda a prevenir conex\u00f5es incorretas ou curtos-circuitos<\/td><\/tr><tr><td>4<\/td><td>Manual de Instru\u00e7\u00f5es do Produto<\/td><td>Fornece orienta\u00e7\u00e3o sobre instala\u00e7\u00e3o, opera\u00e7\u00e3o, manuten\u00e7\u00e3o e fia\u00e7\u00e3o do circuito de medi\u00e7\u00e3o<\/td><\/tr><tr><td>5<\/td><td>Certificado de Produto, Relat\u00f3rio de Teste de F\u00e1brica e Certificado de Verifica\u00e7\u00e3o Metrol\u00f3gica<\/td><td>Fornece documenta\u00e7\u00e3o de qualidade e desempenho do produto, incluindo dados de teste de rela\u00e7\u00e3o de tens\u00e3o, rela\u00e7\u00e3o de corrente e precis\u00e3o.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Normas Aplic\u00e1veis e Certifica\u00e7\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O produto est\u00e1 em conformidade com as seguintes normas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GB 1207, <em>Transformadores de Tens\u00e3o<\/em><\/li>\n\n\n\n<li>GB 1208, <em>Transformadores atuais<\/em><\/li>\n\n\n\n<li>GB\/T 17215, <em>Equipamento de Medi\u00e7\u00e3o de Eletricidade<\/em><\/li>\n\n\n\n<li>DL\/T 448, <em>C\u00f3digo T\u00e9cnico Administrativo para Medi\u00e7\u00e3o de Energia El\u00e9trica<\/em><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">O produto passou nos testes de tipo aplic\u00e1veis e na verifica\u00e7\u00e3o metrol\u00f3gica. Seu desempenho atende aos requisitos de medi\u00e7\u00e3o de energia de sistemas de energia trif\u00e1sicos e de tr\u00eas fios de 6 kV e 10 kV.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"939\" height=\"738\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1.webp\" alt=\"JLSZV-6 10 Unidade de Medi\u00e7\u00e3o Trif\u00e1sica Tr\u00eas Fios Tipo Seco (1)\" class=\"wp-image-2586\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1.webp 939w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1-300x236.webp 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1-768x604.webp 768w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZV-6-10-Three-Phase-Three-Wire-Dry-Type-Metering-Unit1-15x12.webp 15w\" sizes=\"(max-width: 939px) 100vw, 939px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The JLSZV-6\/10 Three-Phase Three-Wire Dry-Type Metering Unit is an integrated high-voltage metering device designed for indoor and outdoor [&hellip;]<\/p>\n","protected":false},"featured_media":2585,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[30],"class_list":["post-1625","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-instrument-transformer-series"],"acf":{"products_imagines":[2585],"short_describe":"<p>The JLSZV-6\/10 Three-Phase Three-Wire Dry-Type Metering Unit is an integrated high-voltage metering device designed for indoor and outdoor 6 kV and 10 kV AC power systems.<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/products\/1625","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/media\/2585"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/media\/2585"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/media?parent=1625"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/product_category?post=1625"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}