{"id":397,"date":"2026-01-23T06:21:56","date_gmt":"2026-01-23T06:21:56","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=397"},"modified":"2026-09-09T03:26:48","modified_gmt":"2026-09-09T03:26:48","slug":"bypass-operation-equipment-adapter-cable-4","status":"publish","type":"products","link":"https:\/\/yieou.com\/pt\/product\/bypass-operation-equipment-adapter-cable-4\/","title":{"rendered":"Equipamento de Opera\u00e7\u00e3o de Bypass de 15kV \u2014 Cabo Adaptador (Cabe\u00e7a em T + Conex\u00e3o R\u00e1pida)"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Vis\u00e3o Geral do Produto<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/pt\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">The 15kV Bypass Operation Equipment \u2014 Adapter Cable (T-head + quick-connect)<\/a> is a dedicated connection <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_cable\" target=\"_blank\" rel=\"noopener\">cable<\/a> designed specifically for live-line bypass operations on 10kV\/15kV medium-voltage distribution systems. One end features a T-type front-access <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" target=\"_blank\" rel=\"noopener\">conector<\/a> that plugs directly into the front-access receptacles of ring main units, cable branch boxes, and other distribution equipment; the other end features a quick-disconnect interface that connects directly to bypass quick-connect devices, forming a temporary bypass power circuit. It is a critical piece of equipment for live-line operations on medium-voltage distribution systems.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Caracter\u00edsticas do Produto<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Desempenho El\u00e9trico e de Isolamento<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Constru\u00eddo com cabo isolado de alta resist\u00eancia com classifica\u00e7\u00e3o de 15kV. O condutor \u00e9 fio de cobre tran\u00e7ado de alta pureza com excelente condutividade e baixa resist\u00eancia de contato. Capaz de transportar correntes nominais de 200A\/630A com eleva\u00e7\u00e3o t\u00e9rmica m\u00ednima durante a opera\u00e7\u00e3o cont\u00ednua, e exibe forte resist\u00eancia \u00e0 corros\u00e3o e oxida\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A camada de isolamento \u00e9 feita de borracha EPDM (mon\u00f4mero de etileno propileno dieno) de alto desempenho com propriedades de isolamento superiores. Ela suporta a tens\u00e3o nominal de um sistema de 15kV, bem como sobretens\u00f5es transit\u00f3rias, atendendo ao requisito operacional de uma tens\u00e3o m\u00e1xima de trabalho de 17,5kV, com descarga parcial n\u00e3o excedendo 10pC (a 1,5U\u2080).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Uma camada de blindagem semicondutora integrada distribui o campo el\u00e9trico uniformemente, suprimindo eficazmente a descarga parcial. O cabo est\u00e1 livre de risco de eros\u00e3o el\u00e9trica e falha durante a opera\u00e7\u00e3o a longo prazo, com desempenho de isolamento est\u00e1vel e confi\u00e1vel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A superf\u00edcie do cabo \u00e9 tratada com um processo especializado que proporciona alta resistividade superficial e forte hidrofobicidade, prevenindo eficazmente o flashover superficial causado por condensa\u00e7\u00e3o e contamina\u00e7\u00e3o, aumentando assim a confiabilidade do isolamento em ambientes agressivos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Estrutura e Seguran\u00e7a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">As duas extremidades apresentam designs de interface diferentes: uma extremidade \u00e9 um conector frontal tipo T compat\u00edvel com recept\u00e1culos frontais de equipamentos de distribui\u00e7\u00e3o; a outra extremidade \u00e9 uma interface de desconex\u00e3o r\u00e1pida que se conecta e desconecta diretamente com dispositivos de conex\u00e3o r\u00e1pida de bypass sem a necessidade de ferramentas adicionais, permitindo uma instala\u00e7\u00e3o conveniente e reduzindo significativamente o tempo de constru\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A constru\u00e7\u00e3o selada integrada incorpora elementos de veda\u00e7\u00e3o dedicados nas interfaces, proporcionando prote\u00e7\u00e3o \u00e0 prova de umidade, \u00e0 prova d'\u00e1gua e \u00e0 prova de polui\u00e7\u00e3o com classifica\u00e7\u00e3o de prote\u00e7\u00e3o de ingresso IP67, adequada para opera\u00e7\u00e3o est\u00e1vel a longo prazo em ambientes \u00famidos, empoeirados, externos e outros ambientes hostis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Estrutura integrada de aterramento\/equipotencializa\u00e7\u00e3o permite aterramento confi\u00e1vel, dissipando eficazmente tens\u00f5es induzidas e correntes de falha para aumentar a seguran\u00e7a do sistema.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Constru\u00e7\u00e3o totalmente isolada com alta resist\u00eancia de isolamento externo permite que a carca\u00e7a seja tocada diretamente durante a opera\u00e7\u00e3o sem risco de choque el\u00e9trico, garantindo a seguran\u00e7a do pessoal de opera\u00e7\u00e3o e manuten\u00e7\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Resist\u00eancia Ambiental e Clim\u00e1tica<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Excelente resist\u00eancia \u00e0s intemp\u00e9ries, adequada para uma ampla faixa de temperatura de -40\u00b0C a +90\u00b0C. A camada isolante e o desempenho do condutor n\u00e3o se degradam em temperaturas extremas, sem risco de rachaduras ou fragiliza\u00e7\u00e3o, tornando-o adequado para aplica\u00e7\u00f5es externas e internas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 prova de umidade, \u00e0 prova d'\u00e1gua, \u00e0 prova de polui\u00e7\u00e3o e resistente \u00e0 n\u00e9voa salina, capaz de opera\u00e7\u00e3o est\u00e1vel a longo prazo em ambientes \u00famidos, empoeirados, com n\u00e9voa salina e outros ambientes hostis, sem ser afetado por chuva ou condensa\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Antienvelhecimento, resistente a UV e \u00e0 corros\u00e3o por oz\u00f4nio, com vida \u00fatil superior a 10 anos, opera\u00e7\u00e3o sem manuten\u00e7\u00e3o e custos operacionais e de manuten\u00e7\u00e3o reduzidos a longo prazo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Caracter\u00edsticas Mec\u00e2nicas e de Compatibilidade<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Alta resist\u00eancia mec\u00e2nica com resist\u00eancia a for\u00e7as de tra\u00e7\u00e3o, flex\u00e3o e impacto. Capaz de suportar tens\u00f5es de tra\u00e7\u00e3o e flex\u00e3o encontradas durante opera\u00e7\u00f5es de campo sem risco de deforma\u00e7\u00e3o ou danos, adequado para condi\u00e7\u00f5es de trabalho complexas no local.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tanto o conector de acesso frontal tipo T quanto a interface de desconex\u00e3o r\u00e1pida adotam designs padronizados que s\u00e3o universalmente intercambi\u00e1veis com equipamentos de distribui\u00e7\u00e3o convencionais e dispositivos de conex\u00e3o r\u00e1pida de bypass, oferecendo forte compatibilidade.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O design modular permite configura\u00e7\u00e3o flex\u00edvel com base nos requisitos operacionais, compat\u00edvel com equipamentos de distribui\u00e7\u00e3o e cabos de bypass de diferentes especifica\u00e7\u00f5es, proporcionando forte versatilidade.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Par\u00e2metros T\u00e9cnicos<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Categoria de Par\u00e2metro<\/td><td>Item<\/td><td>Especifica\u00e7\u00e3o T\u00e9cnica<\/td><\/tr><tr><td>Par\u00e2metros El\u00e9tricos Nominais<\/td><td>Tens\u00e3o do Sistema (Un)<\/td><td>10kV\/15kV<\/td><\/tr><tr><td><\/td><td>Tens\u00e3o Nominal (Ue)<\/td><td>15kV<\/td><\/tr><tr><td><\/td><td>| Tens\u00e3o M\u00e1xima de Trabalho (Um)<\/td><td>17,5kV<\/td><\/tr><tr><td><\/td><td>Frequ\u00eancia Nominal (fn)<\/td><td>50Hz\/60Hz<\/td><\/tr><tr><td><\/td><td>| Tens\u00e3o de Suporte \u00e0 Frequ\u00eancia de Rede<\/td><td>42kV\/5min (seco), sem ruptura, sem centelhamento<\/td><\/tr><tr><td><\/td><td>| Tens\u00e3o de Suporte a Impulsos de Raio<\/td><td>95kV (pico), sem ruptura, sem flashover<\/td><\/tr><tr><td><\/td><td>Descarga Parcial<\/td><td>\u226410pC (a 1.5U\u2080)<\/td><\/tr><tr><td><\/td><td>| Classe de Corrente Nominal<\/td><td>200A\/630A (selecion\u00e1vel)<\/td><\/tr><tr><td><\/td><td>Corrente Nominal de Curto-Circuito<\/td><td>20kA\/2s, 25kA\/2s (selecion\u00e1vel)<\/td><\/tr><tr><td><\/td><td>Resist\u00eancia de Contato<\/td><td>\u226450\u03bc\u03a9<\/td><\/tr><tr><td>Par\u00e2metros Estruturais e de Materiais<\/td><td>Materiais Principais<\/td><td>Fio de cobre nu (condutor), borracha EPDM (camada isolante), cobre estanhado (conector frontal tipo T\/interface de conex\u00e3o r\u00e1pida)<\/td><\/tr><tr><td><\/td><td>| Grau de Prote\u00e7\u00e3o de Entrada<\/td><td>IP67<\/td><\/tr><tr><td><\/td><td>| Padr\u00e3o de Interface<\/td><td>Conector frontal tipo T em uma extremidade, interface de desconex\u00e3o r\u00e1pida na outra, em conformidade com os padr\u00f5es da ind\u00fastria para equipamentos de opera\u00e7\u00e3o de bypass<\/td><\/tr><tr><td><\/td><td>Equipamento Compat\u00edvel<\/td><td>Unidades de anel de 10kV\/15kV, recept\u00e1culos de acesso frontal para caixas de deriva\u00e7\u00e3o de cabos, dispositivos de conex\u00e3o r\u00e1pida para opera\u00e7\u00e3o de bypass<\/td><\/tr><tr><td>Par\u00e2metros Ambientais<\/td><td>Altitude Aplic\u00e1vel<\/td><td>\u22642000m (vers\u00e3o para alta altitude dispon\u00edvel mediante solicita\u00e7\u00e3o)<\/td><\/tr><tr><td><\/td><td>| Temperatura Ambiente<\/td><td>-40\u00b0C a +90\u00b0C (opera\u00e7\u00e3o), -40\u00b0C a +70\u00b0C (armazenamento)<\/td><\/tr><tr><td><\/td><td>Umidade Relativa<\/td><td>\u2264100% (sem condensa\u00e7\u00e3o)<\/td><\/tr><tr><td><\/td><td>| Classifica\u00e7\u00e3o S\u00edsmica<\/td><td>8\u00aa s\u00e9rie<\/td><\/tr><tr><td>Normas Aplic\u00e1veis<\/td><td><\/td><td>GB\/T 12706, DL\/T 1476 Regulamentos de Teste Preventivo para Ferramentas e Instrumentos de Seguran\u00e7a El\u00e9trica, DL\/T 814 Terminal de Automa\u00e7\u00e3o de Distribui\u00e7\u00e3o<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Aplica\u00e7\u00f5es<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Classe de Tens\u00e3o Aplic\u00e1vel: Sistemas de distribui\u00e7\u00e3o de m\u00e9dia tens\u00e3o CA de 10kV\/15kV; compat\u00edvel com equipamentos de distribui\u00e7\u00e3o classificados para uma tens\u00e3o m\u00e1xima de trabalho de 17,5kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cen\u00e1rios Operacionais Aplic\u00e1veis:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Manuten\u00e7\u00e3o em linha viva e opera\u00e7\u00f5es de retrofit em unidades de anel de 10kV\/15kV, caixas de deriva\u00e7\u00e3o de cabos e outros equipamentos de distribui\u00e7\u00e3o, servindo como conex\u00e3o adaptadora entre equipamentos de distribui\u00e7\u00e3o e cabos de bypass;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Opera\u00e7\u00f5es de bypass em linha viva em cabos de rede de distribui\u00e7\u00e3o urbana, sistemas de distribui\u00e7\u00e3o de energia de empresas industriais e de minera\u00e7\u00e3o, e equipamentos de distribui\u00e7\u00e3o de esta\u00e7\u00f5es elevadoras de nova energia (fotovoltaica\/e\u00f3lica);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fonte de alimenta\u00e7\u00e3o tempor\u00e1ria de bypass para equipamentos de distribui\u00e7\u00e3o em salas de distribui\u00e7\u00e3o internas\/externas, t\u00faneis de servi\u00e7os p\u00fablicos subterr\u00e2neos, t\u00faneis de cabos e outras instala\u00e7\u00f5es multisscen\u00e1rio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prop\u00f3sito Funcional: Estabelecer isolamento isolado e conex\u00e3o condutiva entre os recept\u00e1culos de acesso frontal de equipamentos de distribui\u00e7\u00e3o e cabos de bypass, permitindo opera\u00e7\u00f5es de bypass em linha viva, garantindo o fornecimento cont\u00ednuo de energia aos clientes durante a manuten\u00e7\u00e3o e moderniza\u00e7\u00e3o de equipamentos de distribui\u00e7\u00e3o, e fornecendo uma solu\u00e7\u00e3o de conex\u00e3o segura e confi\u00e1vel para opera\u00e7\u00f5es em linha viva em sistemas de distribui\u00e7\u00e3o de m\u00e9dia tens\u00e3o.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Condi\u00e7\u00f5es de Opera\u00e7\u00e3o<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Condi\u00e7\u00f5es Normais de Opera\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude: \u22642000m<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura ambiente: -40\u00b0C a +90\u00b0C; a temperatura de opera\u00e7\u00e3o do equipamento deve estar em conformidade com as normas relevantes<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Umidade relativa: \u2264100% (sem condensa\u00e7\u00e3o)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Condi\u00e7\u00f5es ambientais: livre de gases corrosivos, meios inflam\u00e1veis\/explosivos e vibra\u00e7\u00f5es ou choques severos<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00e9todo de instala\u00e7\u00e3o: o conector tipo T de acesso frontal conecta-se diretamente ao recept\u00e1culo de acesso frontal do equipamento de distribui\u00e7\u00e3o; a interface de conex\u00e3o r\u00e1pida conecta-se diretamente \u00e0 interface do dispositivo de bypass; ambas as instala\u00e7\u00f5es horizontal e vertical s\u00e3o permitidas; o espa\u00e7o de instala\u00e7\u00e3o deve atender aos requisitos operacionais<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Condi\u00e7\u00f5es Operacionais Especiais (Requer Personaliza\u00e7\u00e3o)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude superior a 2000m<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura ambiente fora da faixa de -40\u00b0C a +90\u00b0C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ambientes severamente polu\u00eddos, com n\u00e9voa salina ou quimicamente corrosivos<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Condi\u00e7\u00f5es operacionais de alta vibra\u00e7\u00e3o ou alto impacto<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Especifica\u00e7\u00f5es de interface n\u00e3o padr\u00e3o ou requisitos especiais de comprimento de cabo<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Classifica\u00e7\u00f5es de corrente especiais ou requisitos de capacidade de condu\u00e7\u00e3o de corrente<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Instala\u00e7\u00e3o e Manuten\u00e7\u00e3o<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Requisitos de Instala\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Antes da instala\u00e7\u00e3o, inspecione a apar\u00eancia do produto quanto a rachaduras, danos e vazios, e verifique se a superf\u00edcie do isolamento est\u00e1 intacta. Verifique se o conector frontal tipo T e a interface de conex\u00e3o r\u00e1pida est\u00e3o \u00edntegros, livres de ferrugem e deforma\u00e7\u00e3o, e se o mecanismo de travamento funciona de forma suave e confi\u00e1vel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Limpe a parede interna do recept\u00e1culo de acesso frontal do equipamento de distribui\u00e7\u00e3o e a superf\u00edcie do conector de acesso frontal tipo T para remover graxa, poeira e mat\u00e9ria estranha, garantindo que as interfaces estejam secas e limpas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aplique uma camada uniforme de graxa lubrificante de silicone dedicada \u00e0s superf\u00edcies externas do conector de acesso frontal tipo T e da interface de conex\u00e3o r\u00e1pida para evitar danos \u00e0 camada isolante durante a instala\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Insira lentamente o conector tipo T de acesso frontal no recept\u00e1culo de acesso frontal do equipamento de distribui\u00e7\u00e3o, garantindo que esteja totalmente encaixado, e ent\u00e3o acione o mecanismo de travamento anti-retirada. Conecte a interface de conex\u00e3o r\u00e1pida \u00e0 interface do dispositivo de bypass firmemente, garantindo que esteja totalmente encaixada, e ent\u00e3o acione o mecanismo de travamento anti-retirada. Ap\u00f3s a instala\u00e7\u00e3o, verifique se n\u00e3o h\u00e1 folga ou desalinhamento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ap\u00f3s a conclus\u00e3o da instala\u00e7\u00e3o, realize testes de resist\u00eancia de isolamento e testes de tens\u00e3o suport\u00e1vel em frequ\u00eancia industrial. O equipamento s\u00f3 poder\u00e1 ser energizado ap\u00f3s a aprova\u00e7\u00e3o nesses testes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Requisitos de Manuten\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Inspecione periodicamente a apar\u00eancia do cabo quanto a rachaduras, danos, marcas de descarga e ac\u00famulo de contamina\u00e7\u00e3o. Verifique se o conector frontal tipo T est\u00e1 firmemente encaixado no recept\u00e1culo do equipamento de distribui\u00e7\u00e3o sem folgas, e se a conex\u00e3o da interface de engate r\u00e1pido ao dispositivo de bypass \u00e9 confi\u00e1vel e livre de ferrugem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Teste periodicamente a resist\u00eancia de isolamento para verificar a conformidade de desempenho e para detectar falhas potenciais em tempo h\u00e1bil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Limpe a superf\u00edcie e as interfaces do cabo para remover poeira e contamina\u00e7\u00e3o, mantendo as superf\u00edcies de isolamento secas e limpas, e protegendo-as contra graxa e corros\u00e3o qu\u00edmica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se forem encontradas fissuras, danos, descargas, sobreaquecimento ou outras anomalias no cabo ou nas interfaces, retire imediatamente o equipamento de servi\u00e7o e substitua-o. \u00c9 estritamente proibido operar equipamento defeituoso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As opera\u00e7\u00f5es de conex\u00e3o\/desconex\u00e3o de interfaces devem ser realizadas com ferramentas de opera\u00e7\u00e3o isoladas dedicadas. A opera\u00e7\u00e3o manual de interfaces energizadas \u00e9 estritamente proibida. Todas as opera\u00e7\u00f5es devem cumprir rigorosamente os regulamentos de seguran\u00e7a de distribui\u00e7\u00e3o de energia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Precau\u00e7\u00f5es<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Este produto deve ser instalado, comissionado e mantido por pessoal el\u00e9trico qualificado e com certifica\u00e7\u00e3o v\u00e1lida para trabalhos em m\u00e9dia tens\u00e3o em linha viva. A opera\u00e7\u00e3o por pessoal n\u00e3o qualificado \u00e9 estritamente proibida.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este produto deve ser utilizado em conjunto com equipamentos de distribui\u00e7\u00e3o e dispositivos de opera\u00e7\u00e3o de bypass da especifica\u00e7\u00e3o correspondente. \u00c9 estritamente proibido o cruzamento de equipamentos de diferentes classes de tens\u00e3o ou diferentes classifica\u00e7\u00f5es de corrente, pois isso resultar\u00e1 em falha de isolamento e incidentes de seguran\u00e7a.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O cabo n\u00e3o deve ser desmontado ou modificado sem autoriza\u00e7\u00e3o, pois isso anula a garantia e a garantia de seguran\u00e7a. O uso de ferramentas n\u00e3o dedicadas para instalar ou remover as interfaces \u00e0 for\u00e7a \u00e9 estritamente proibido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Durante a instala\u00e7\u00e3o, \u00e9 estritamente proibido danificar a superf\u00edcie de isolamento. Deve ser aplicada graxa lubrificante de silicone uniformemente para evitar comprometer o desempenho do isolamento e a efic\u00e1cia da veda\u00e7\u00e3o. As interfaces devem estar totalmente travadas na posi\u00e7\u00e3o para evitar mau contato que leve a superaquecimento ou descarga.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Durante o armazenamento, o produto deve ser mantido em ambiente seco, ventilado e fresco, longe da luz solar direta, altas temperaturas, umidade e compress\u00e3o. O contato com objetos pontiagudos que possam danificar a camada isolante \u00e9 estritamente proibido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ao conectar ou desconectar interfaces energizadas, os regulamentos de seguran\u00e7a de distribui\u00e7\u00e3o de energia devem ser rigorosamente observados, e todas as medidas de prote\u00e7\u00e3o de seguran\u00e7a necess\u00e1rias devem estar em vigor. Opera\u00e7\u00f5es n\u00e3o autorizadas s\u00e3o estritamente proibidas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Designa\u00e7\u00e3o do Modelo<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Identificador do Modelo<\/th><th>Significado<\/th><\/tr><\/thead><tbody><tr><td>15kV<\/td><td>Classe de tens\u00e3o do sistema aplic\u00e1vel; tens\u00e3o nominal 15kV, tens\u00e3o m\u00e1xima de trabalho 17,5kV<\/td><\/tr><tr><td>Conector Frontal + Conex\u00e3o R\u00e1pida<\/td><td>Configura\u00e7\u00e3o da interface; um terminal conector tipo T de acesso frontal, um terminal de interface de desconex\u00e3o r\u00e1pida<\/td><\/tr><tr><td>Cabo Adaptador<\/td><td>Cabo de transi\u00e7\u00e3o usado para conex\u00e3o entre o recept\u00e1culo de acesso frontal do equipamento de distribui\u00e7\u00e3o e os dispositivos de opera\u00e7\u00e3o de bypass<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Normas e Certifica\u00e7\u00f5es Aplic\u00e1veis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Norma Internacional: IEC 60840 M\u00e9todos de Ensaio e Requisitos para Cabos de Pot\u00eancia com Isolamento Extrudido e Seus Acess\u00f3rios para Tens\u00f5es Nominais Acima de 30kV (Um=36kV) at\u00e9 150kV (Um=170kV)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Normas Nacionais: GB\/T 12706 Cabos de Pot\u00eancia com Isolamento Extrudido e seus Acess\u00f3rios para Tens\u00f5es Nominais de 1kV (Um=1,2kV) at\u00e9 35kV (Um=40,5kV), DL\/T 1476 Regulamentos de Teste Preventivo para Ferramentas e Instrumentos de Seguran\u00e7a em Energia El\u00e9trica, DL\/T 814 Terminal de Automa\u00e7\u00e3o de Distribui\u00e7\u00e3o<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O produto passou por testes de tipo realizados pelo Centro Nacional de Supervis\u00e3o e Inspe\u00e7\u00e3o de Qualidade de Ferramentas e Instrumentos de Seguran\u00e7a de Energia El\u00e9trica e est\u00e1 em conformidade com os padr\u00f5es nacionais da ind\u00fastria de energia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Servi\u00e7o P\u00f3s-Venda<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per\u00edodo de garantia do produto: 18 meses a partir da data de fabrica\u00e7\u00e3o, ou 12 meses a partir da data de comissionamento, o que ocorrer primeiro.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Durante o per\u00edodo de garantia, defeitos no produto devido a problemas de qualidade ser\u00e3o reparados ou substitu\u00eddos gratuitamente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Suporte t\u00e9cnico, orienta\u00e7\u00e3o de instala\u00e7\u00e3o e servi\u00e7os de personaliza\u00e7\u00e3o est\u00e3o dispon\u00edveis (especifica\u00e7\u00f5es especiais e adapta\u00e7\u00f5es para condi\u00e7\u00f5es operacionais especiais).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aviso de Documenta\u00e7\u00e3o<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Os par\u00e2metros t\u00e9cnicos neste manual s\u00e3o baseados em condi\u00e7\u00f5es operacionais padr\u00e3o. Condi\u00e7\u00f5es operacionais especiais exigem personaliza\u00e7\u00e3o de acordo com os requisitos reais. O acordo t\u00e9cnico do produto e o relat\u00f3rio de teste de tipo servir\u00e3o como refer\u00eancia final e autoritativa.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ap\u00eandice: Desenho do Esbo\u00e7o do Produto<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"444\" height=\"447\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/Adapter-cable-T-head-quick-connect.png\" alt=\"adapter-cable-t-head-quick-connect\" class=\"wp-image-398\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/Adapter-cable-T-head-quick-connect.png 444w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/Adapter-cable-T-head-quick-connect-298x300.png 298w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/Adapter-cable-T-head-quick-connect-150x150.png 150w\" sizes=\"(max-width: 444px) 100vw, 444px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The 15kV Bypass Operation Equipment \u2014 Adapter Cable (T-head + quick-connect) is a dedicated connection cable designed specifically [&hellip;]<\/p>\n","protected":false},"featured_media":398,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[13],"class_list":["post-397","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-quick-plug-series"],"acf":{"products_imagines":[398],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/products\/397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/media\/398"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/media\/398"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/media?parent=397"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/pt\/wp-json\/wp\/v2\/product_category?post=397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}