{"id":1612,"date":"2026-05-08T00:00:00","date_gmt":"2026-05-08T00:00:00","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1612"},"modified":"2026-09-15T01:51:22","modified_gmt":"2026-09-15T01:51:22","slug":"jdzx10-10-36-10arel-10-voltage-transformer","status":"publish","type":"products","link":"https:\/\/yieou.com\/pt_br\/product\/jdzx10-10-36-10arel-10-voltage-transformer\/","title":{"rendered":"Transformador de Tens\u00e3o JDZ(X)10-10-3,6\/10A (REL-10)"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Transformador de Tens\u00e3o JDZ(X)10-10-3,6\/10A (REL-10)<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vis\u00e3o Geral do Produto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/pt_br\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">O transformador de tens\u00e3o JDZ(X)10-10-3,6\/10A(REL-10)<\/a> \u00e9 um transformador de tens\u00e3o totalmente fechado, tipo seco, encapsulado em resina, projetado para sistemas de energia CA internos de 10kV (Um=12kV). Ele emprega uma estrutura de isolamento integral de resina ep\u00f3xi fundida a v\u00e1cuo com um resistor dedicado limitador de corrente embutido. A unidade serve a m\u00faltiplas fun\u00e7\u00f5es, incluindo medi\u00e7\u00e3o de tens\u00e3o, medi\u00e7\u00e3o de energia, prote\u00e7\u00e3o de rel\u00e9 e substitui\u00e7\u00e3o de fus\u00edveis. \u00c9 usado principalmente em m\u00e9dia tens\u00e3o interna <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a> (por exemplo, s\u00e9rie KYN28) para monitoramento de tens\u00e3o, supervis\u00e3o de isolamento e aquisi\u00e7\u00e3o de sinais de prote\u00e7\u00e3o, e \u00e9 amplamente aplicado em sistemas de distribui\u00e7\u00e3o de 10kV, subesta\u00e7\u00f5es pr\u00e9-fabricadas e unidades de anel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Principais Recursos do Produto<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Isolamento e Desempenho El\u00e9trico<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Isolamento Totalmente Encapsulado em Resina Ep\u00f3xi: A unidade inteira \u00e9 formada por fundi\u00e7\u00e3o a v\u00e1cuo com resina ep\u00f3xi, resultando em um interior sem vazios e com excelente desempenho de isolamento. Suporta a tens\u00e3o de opera\u00e7\u00e3o do sistema de 12kV e passa nos testes de tens\u00e3o suportada em frequ\u00eancia industrial e de impulso. O isolamento tem longa vida \u00fatil, sem risco de vazamento ou contamina\u00e7\u00e3o por \u00f3leo, tornando-o adequado para aplica\u00e7\u00f5es de distribui\u00e7\u00e3o interna sem \u00f3leo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prote\u00e7\u00e3o Integrada de Limita\u00e7\u00e3o de Corrente: O resistor de limita\u00e7\u00e3o de corrente embutido substitui fus\u00edveis convencionais para fornecer prote\u00e7\u00e3o contra sobrecorrente para o transformador de tens\u00e3o, evitando danos por curtos-circuitos no circuito secund\u00e1rio ou eventos de sobrecorrente, melhorando a confiabilidade operacional do sistema e simplificando o projeto do circuito secund\u00e1rio dentro do painel de manobra.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Compatibilidade com Ampla Rela\u00e7\u00e3o de Tens\u00e3o: Suporta m\u00faltiplas rela\u00e7\u00f5es de tens\u00e3o (por exemplo, 10\/0,1kV, 10\/0,1\/0,1kV, etc.) com sa\u00eddas secund\u00e1rias multi-tap simult\u00e2neas para medi\u00e7\u00e3o, prote\u00e7\u00e3o e supervis\u00e3o de isolamento. As classes de precis\u00e3o s\u00e3o personaliz\u00e1veis (0,2\/0,5\/1 \/ 3P\/6P, etc.) para atender a diversos requisitos de aplica\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Projeto de Baixa Descarga Parcial: O processo avan\u00e7ado de fundi\u00e7\u00e3o garante um n\u00edvel de descarga parcial \u226410pC, prevenindo o envelhecimento do isolamento causado pela atividade de descarga parcial a longo prazo e melhorando a confiabilidade operacional a longo prazo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Caracter\u00edsticas Estruturais e de Instala\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Constru\u00e7\u00e3o Totalmente Fechada a Seco: A estrutura fundida integralmente n\u00e3o possui n\u00facleo exposto ou partes energizadas, com grau de prote\u00e7\u00e3o IP20, sem risco de inc\u00eandio, dimens\u00f5es compactas, ocupando pouco espa\u00e7o e compat\u00edvel com as dimens\u00f5es de instala\u00e7\u00e3o de quadros el\u00e9tricos padr\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Design de Modelo Duplo: JDZ10-10 \u00e9 do tipo de enrolamento \u00fanico; JDZX10-10 \u00e9 do tipo de enrolamento de tens\u00e3o residual (para supervis\u00e3o de isolamento). Os modelos podem ser selecionados de forma flex\u00edvel com base nos requisitos do sistema para acomodar diferentes tipos de pain\u00e9is e esquemas de prote\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Identifica\u00e7\u00e3o Clara de Terminais: Terminais prim\u00e1rios de alta tens\u00e3o s\u00e3o claramente rotulados; terminais secund\u00e1rios s\u00e3o protegidos por tampas transparentes para fia\u00e7\u00e3o conveniente, prevenindo fia\u00e7\u00e3o incorreta e curtos-circuitos, ao mesmo tempo que protegem contra curtos-circuitos acidentais no circuito secund\u00e1rio. O layout dos terminais est\u00e1 em conformidade com os padr\u00f5es de fia\u00e7\u00e3o interna de pain\u00e9is de manobra.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Instala\u00e7\u00e3o Flex\u00edvel: A base de montagem met\u00e1lica inferior inclui furos de fixa\u00e7\u00e3o para suportar instala\u00e7\u00e3o aparafusada. Compat\u00edvel com montagem horizontal em pain\u00e9is el\u00e9tricos internos, proporciona instala\u00e7\u00e3o segura com excelente resist\u00eancia \u00e0 vibra\u00e7\u00e3o para arranjos de pain\u00e9is compactos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Recursos Operacionais e de Manuten\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Opera\u00e7\u00e3o sem Manuten\u00e7\u00e3o: A constru\u00e7\u00e3o seca e isenta de \u00f3leo elimina vazamentos e riscos de inc\u00eandio. O corpo fundido em resina ep\u00f3xi possui alta resist\u00eancia mec\u00e2nica, resist\u00eancia ao impacto e resist\u00eancia ao envelhecimento, permitindo opera\u00e7\u00e3o de longo prazo sem manuten\u00e7\u00e3o, reduzindo custos de O&amp;M e eliminando a necessidade de substitui\u00e7\u00e3o peri\u00f3dica de fus\u00edveis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ampla Faixa de Temperatura de Opera\u00e7\u00e3o: Adequado para temperaturas ambientes de -30\u00b0C a +70\u00b0C. O desempenho da resina ep\u00f3xi permanece est\u00e1vel em temperaturas extremas, sem risco de fragiliza\u00e7\u00e3o ou deforma\u00e7\u00e3o, acomodando diversas condi\u00e7\u00f5es clim\u00e1ticas regionais.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Projeto de Alta Confiabilidade: Enrolamentos s\u00e3o feitos com fio de cobre esmaltado; o n\u00facleo \u00e9 laminado a partir de chapas de a\u00e7o sil\u00edcio de alta qualidade. A unidade opera com baixas perdas e baixa gera\u00e7\u00e3o de calor, suporta sobretens\u00f5es de comuta\u00e7\u00e3o do sistema e sobretens\u00f5es de impulso de raio, e incorpora um resistor limitador de corrente est\u00e1vel para garantir um desempenho de prote\u00e7\u00e3o confi\u00e1vel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Par\u00e2metros T\u00e9cnicos (Especifica\u00e7\u00f5es T\u00edpicas)<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Categoria de Par\u00e2metro<\/td><td>Item<\/td><td>Especifica\u00e7\u00e3o T\u00e9cnica<\/td><\/tr><tr><td>Par\u00e2metros El\u00e9tricos<\/td><td>Tens\u00e3o do Sistema<\/td><td>10kV CA (Um=12kV)<\/td><\/tr><tr><td><\/td><td>Frequ\u00eancia Nominal<\/td><td>50Hz<\/td><\/tr><tr><td><\/td><td>| Tens\u00e3o Prim\u00e1ria Nominal<\/td><td>10kV<\/td><\/tr><tr><td><\/td><td>Tens\u00e3o Secund\u00e1ria Nominal<\/td><td>100V (medi\u00e7\u00e3o\/prote\u00e7\u00e3o); 100\/3V (supervis\u00e3o de isolamento, tipo JDZX) (personaliz\u00e1vel)<\/td><\/tr><tr><td><\/td><td>Corrente Nominal de Sa\u00edda<\/td><td>3A \/ 6A \/ 10A (com prote\u00e7\u00e3o de limita\u00e7\u00e3o de corrente integrada)<\/td><\/tr><tr><td><\/td><td>| Classe de Precis\u00e3o do Medidor<\/td><td>0.2 \/ 0.5 \/ 1<\/td><\/tr><tr><td><\/td><td>| Classe de Precis\u00e3o de Prote\u00e7\u00e3o<\/td><td>3P \/ 6P<\/td><\/tr><tr><td><\/td><td>| Tens\u00e3o de Suporte em Frequ\u00eancia de Rede (Prim\u00e1rio)<\/td><td>42kV \/ 1min, sem ruptura<\/td><\/tr><tr><td><\/td><td>Tens\u00e3o de Suporte a Impulso (Pico)<\/td><td>75kV, sem ruptura<\/td><\/tr><tr><td><\/td><td>N\u00edvel de Descarga Parcial<\/td><td>\u226410pC<\/td><\/tr><tr><td><\/td><td>Resist\u00eancia de Isolamento (Alta Tens\u00e3o para Baixa Tens\u00e3o e Terra)<\/td><td>\u22651000M\u03a9<\/td><\/tr><tr><td>Par\u00e2metros Estruturais e de Materiais<\/td><td>Meio Isolante<\/td><td>Moldagem completa em resina ep\u00f3xi<\/td><\/tr><tr><td><\/td><td>| Grau de Prote\u00e7\u00e3o<\/td><td>IP20<\/td><\/tr><tr><td><\/td><td>| M\u00e9todo de Montagem<\/td><td>Montagem interna tipo poste aparafusada<\/td><\/tr><tr><td><\/td><td>| Classe T\u00e9rmica de Isolamento<\/td><td>Classe B (130\u00b0C)<\/td><\/tr><tr><td>Par\u00e2metros Ambientais<\/td><td>Altitude de Opera\u00e7\u00e3o<\/td><td>\u22642000m (personaliza\u00e7\u00e3o para alta altitude dispon\u00edvel)<\/td><\/tr><tr><td><\/td><td>| Temperatura Ambiente de Opera\u00e7\u00e3o<\/td><td>-30\u00b0C a +70\u00b0C<\/td><\/tr><tr><td><\/td><td>| Temperatura Ambiente de Armazenamento<\/td><td>-40\u00b0C a +85\u00b0C<\/td><\/tr><tr><td><\/td><td>| Umidade Relativa<\/td><td>\u226495% (sem condensa\u00e7\u00e3o)<\/td><\/tr><tr><td>Normas Aplic\u00e1veis<\/td><td>Normas Nacionais<\/td><td>GB 1207 Transformadores de Tens\u00e3o; GB\/T 20840.1 Transformadores de Instrumento \u2014 Parte 1: Requisitos Gerais; GB\/T 20840.3 Transformadores de Instrumento \u2014 Parte 3: Requisitos Adicionais para Transformadores de Tens\u00e3o Indutivos<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Escopo da Aplica\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Classe de Tens\u00e3o Aplic\u00e1vel: Sistemas de energia CA internos de 10kV (Um=12kV).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cen\u00e1rios de Aplica\u00e7\u00e3o T\u00edpicos:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Medi\u00e7\u00e3o de tens\u00e3o, medi\u00e7\u00e3o de energia e prote\u00e7\u00e3o de rel\u00e9s em pain\u00e9is de manobra de m\u00e9dia tens\u00e3o internos (s\u00e9rie KYN28) e subesta\u00e7\u00f5es pr\u00e9-fabricadas;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">sistemas de distribui\u00e7\u00e3o de 10kV em subesta\u00e7\u00f5es de distribui\u00e7\u00e3o, empresas industriais e de minera\u00e7\u00e3o, edif\u00edcios comerciais e parques industriais;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aquisi\u00e7\u00e3o de sinais de monitoramento, controle e prote\u00e7\u00e3o de tens\u00e3o em sistemas de automa\u00e7\u00e3o de energia;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aplica\u00e7\u00f5es de pain\u00e9is de manobra de 10kV que exigem circuitos secund\u00e1rios simplificados e substitui\u00e7\u00e3o de fus\u00edveis, adequados para projetos de pain\u00e9is compactos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prop\u00f3sito Funcional: Converte a alta tens\u00e3o do sistema em uma baixa tens\u00e3o padronizada (100V) proporcionalmente, a fim de fornecer sinais de tens\u00e3o para instrumentos de medi\u00e7\u00e3o, dispositivos de prote\u00e7\u00e3o e equipamentos de controle, ao mesmo tempo em que proporciona isolamento el\u00e9trico entre os sistemas prim\u00e1rio e secund\u00e1rio. O resistor limitador de corrente embutido oferece prote\u00e7\u00e3o contra sobrecorrente; o tipo JDZX tamb\u00e9m pode servir como fonte de sinal de tens\u00e3o para dispositivos de supervis\u00e3o de isolamento, monitorando falhas de aterramento do sistema.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Condi\u00e7\u00f5es de Opera\u00e7\u00e3o<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Condi\u00e7\u00f5es Normais de Opera\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude: \u22642000m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura ambiente: -30\u00b0C a +70\u00b0C, sem flutua\u00e7\u00f5es severas de temperatura;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Umidade Relativa: \u226495% (sem condensa\u00e7\u00e3o);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Condi\u00e7\u00f5es Ambientais: Livre de gases corrosivos, meios inflam\u00e1veis\/explosivos, vibra\u00e7\u00e3o e choques severos, e poeira ou n\u00e9voa salina significativas;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00e9todo de Instala\u00e7\u00e3o: Montagem interna em poste, longe da luz solar direta, chuva e condensa\u00e7\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Condi\u00e7\u00f5es Operacionais Especiais (Requerendo Personaliza\u00e7\u00e3o)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude superior a 2000m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperatura ambiente fora da faixa de -30\u00b0C a +70\u00b0C;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ambientes severamente polu\u00eddos, com n\u00e9voa salina ou quimicamente corrosivos;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Condi\u00e7\u00f5es de opera\u00e7\u00e3o com alta vibra\u00e7\u00e3o ou alto impacto;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rela\u00e7\u00f5es de tens\u00e3o n\u00e3o padronizadas, classes de precis\u00e3o ou dimens\u00f5es de montagem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Instala\u00e7\u00e3o e Manuten\u00e7\u00e3o<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Requisitos de Instala\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Inspe\u00e7\u00e3o Pr\u00e9-Instala\u00e7\u00e3o: Inspecione o transformador de potencial quanto a danos externos \u2014 o corpo fundido n\u00e3o deve apresentar trincas, vazios ou quebras; as marca\u00e7\u00f5es dos terminais devem estar claras e todos os acess\u00f3rios presentes. Verifique se o modelo, especifica\u00e7\u00e3o, rela\u00e7\u00e3o de tens\u00e3o, corrente nominal e fun\u00e7\u00e3o de prote\u00e7\u00e3o limitadora de corrente est\u00e3o em conformidade com os requisitos de projeto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fixa\u00e7\u00e3o Mec\u00e2nica: Posicione o transformador de tens\u00e3o no local de montagem designado dentro do painel e fixe-o pelos furos de montagem inferiores usando parafusos. Certifique-se de que a instala\u00e7\u00e3o esteja firme, sem folgas ou desalinhamentos, e que a superf\u00edcie de montagem esteja nivelada para evitar carregamento exc\u00eantrico.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fia\u00e7\u00e3o do Lado Prim\u00e1rio (Alta Tens\u00e3o): Conecte os terminais de alta tens\u00e3o de acordo com os requisitos de projeto, garantindo conex\u00f5es firmes com bom contato. Mantenha dist\u00e2ncias de seguran\u00e7a adequadas entre os cabos de alta tens\u00e3o e partes aterradas ou outras partes energizadas para evitar centelhamento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fia\u00e7\u00e3o do Lado Secund\u00e1rio (Baixa Tens\u00e3o): Conecte os terminais de baixa tens\u00e3o de acordo com as marca\u00e7\u00f5es, com fia\u00e7\u00e3o separada para os circuitos de medi\u00e7\u00e3o, prote\u00e7\u00e3o e supervis\u00e3o de isolamento. Garanta a fia\u00e7\u00e3o correta. O circuito secund\u00e1rio nunca deve ser curto-circuitado e deve ser aterrado de forma confi\u00e1vel (aterramento em ponto \u00fanico) para evitar sobretens\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Teste de Isolamento: Ap\u00f3s a instala\u00e7\u00e3o, me\u00e7a a resist\u00eancia de isolamento (Alta Tens\u00e3o para Baixa Tens\u00e3o e terra; Baixa Tens\u00e3o para terra) para confirmar que o desempenho do isolamento atende aos requisitos. Verifique se a fia\u00e7\u00e3o do circuito secund\u00e1rio est\u00e1 correta, sem curtos-circuitos ou circuitos abertos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pontos Chave de Manuten\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Inspecione periodicamente o transformador de potencial externamente \u2014 o corpo fundido n\u00e3o deve apresentar trincas, danos ou marcas de descarga; os terminais prim\u00e1rios n\u00e3o devem apresentar folgas ou oxida\u00e7\u00e3o; as tampas de prote\u00e7\u00e3o dos terminais secund\u00e1rios devem estar intactas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Inspecione periodicamente as conex\u00f5es prim\u00e1rias e secund\u00e1rias quanto a aperto, sem sinais de superaquecimento ou descolora\u00e7\u00e3o. Verifique se a aterramento do circuito secund\u00e1rio \u00e9 confi\u00e1vel, sem risco de curto-circuito ou circuito aberto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Teste periodicamente a resist\u00eancia de isolamento e a rela\u00e7\u00e3o de tens\u00e3o para confirmar que a precis\u00e3o da medi\u00e7\u00e3o e prote\u00e7\u00e3o atende aos requisitos, e verifique se a fun\u00e7\u00e3o de prote\u00e7\u00e3o limitadora de corrente est\u00e1 operando corretamente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Limpe poeira e contamina\u00e7\u00e3o da superf\u00edcie do transformador; evite que subst\u00e2ncias oleosas ou corrosivas se fixem; mantenha o equipamento seco e limpo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Em caso de trincas, descargas, superaquecimento, desvio da rela\u00e7\u00e3o de tens\u00e3o ou falha da fun\u00e7\u00e3o de prote\u00e7\u00e3o, desenergize imediatamente para inspe\u00e7\u00e3o e substitua o equipamento, se necess\u00e1rio. N\u00e3o opere uma unidade defeituosa.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Precau\u00e7\u00f5es<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Os enrolamentos secund\u00e1rios nunca devem ser curto-circuitados. Caso ocorra um curto-circuito no circuito secund\u00e1rio durante a opera\u00e7\u00e3o, o resistor limitador de corrente atuar\u00e1 para proteger o equipamento; no entanto, a falha ainda deve ser investigada e corrigida prontamente. Durante a manuten\u00e7\u00e3o, o circuito secund\u00e1rio deve ser confiavelmente aberto e aterrado.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Evite impactos mec\u00e2nicos ou choques no corpo fundido durante a instala\u00e7\u00e3o para prevenir rachaduras na resina ep\u00f3xi ou danos ao isolamento que comprometeriam o desempenho diel\u00e9trico.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A fia\u00e7\u00e3o do lado prim\u00e1rio deve usar cabos isolados dedicados, com folgas de seguran\u00e7a adequadas mantidas em rela\u00e7\u00e3o a partes aterradas e outras partes energizadas para evitar descargas el\u00e9tricas entre fases ou entre fase e terra.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A liga\u00e7\u00e3o \u00e0 terra do equipamento deve ser confi\u00e1vel \u2014 o terminal de aterramento da base deve ser firmemente conectado \u00e0 barra de aterramento do painel para garantir o aterramento adequado do equipamento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Durante o armazenamento, coloque a unidade em um ambiente seco, bem ventilado e fresco, longe da luz solar direta, altas temperaturas, umidade e cargas de compress\u00e3o para evitar o envelhecimento ou a deforma\u00e7\u00e3o do corpo fundido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A instala\u00e7\u00e3o, a coloca\u00e7\u00e3o em funcionamento e a manuten\u00e7\u00e3o devem ser realizadas por pessoal el\u00e9trico qualificado, em estrita conformidade com os procedimentos operacionais de seguran\u00e7a el\u00e9trica.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Configura\u00e7\u00e3o de Fornecimento Padr\u00e3o<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>N\u00e3o.<\/td><td>Item<\/td><td>Prop\u00f3sito<\/td><\/tr><tr><td>1<\/td><td>Transformador de Tens\u00e3o JDZ(X)10-10-3,6\/10A (REL-10) Corpo<\/td><td>Unidade central para transforma\u00e7\u00e3o de tens\u00e3o, isolamento, prote\u00e7\u00e3o de limita\u00e7\u00e3o de corrente e aquisi\u00e7\u00e3o de sinal<\/td><\/tr><tr><td>2<\/td><td>Parafusos e Arruelas de Montagem<\/td><td>Para fixa\u00e7\u00e3o mec\u00e2nica do transformador de tens\u00e3o<\/td><\/tr><tr><td>3<\/td><td>Tampa Protetora Transparente do Terminal Secund\u00e1rio<\/td><td>Protege terminais de fia\u00e7\u00e3o de baixa tens\u00e3o contra conex\u00f5es incorretas e curtos-circuitos<\/td><\/tr><tr><td>4<\/td><td>Manual do Produto<\/td><td>Guia de instala\u00e7\u00e3o, opera\u00e7\u00e3o e manuten\u00e7\u00e3o, incluindo descri\u00e7\u00e3o da prote\u00e7\u00e3o limitadora de corrente<\/td><\/tr><tr><td>5<\/td><td>Certificado de Conformidade do Produto e Relat\u00f3rio de Teste de F\u00e1brica<\/td><td>Documenta\u00e7\u00e3o de qualidade e desempenho do produto, incluindo dados de teste de rela\u00e7\u00e3o de tens\u00e3o, erro e prote\u00e7\u00e3o contra limita\u00e7\u00e3o de corrente<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Normas e Certifica\u00e7\u00f5es Aplic\u00e1veis<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Este produto est\u00e1 em conformidade com as normas nacionais GB 1207 Transformadores de Tens\u00e3o, GB\/T 20840.1 Transformadores de Instrumentos \u2014 Parte 1: Requisitos Gerais, e GB\/T 20840.3 Transformadores de Instrumentos \u2014 Parte 3: Requisitos Adicionais para Transformadores de Tens\u00e3o Indutivos, e passou por testes de tipo. O desempenho atende aos requisitos operacionais de sistemas de energia internos de 10kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ap\u00eandice: Desenho Esquem\u00e1tico do Produto<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"360\" height=\"360\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZX10-10-3610AREL-10-Voltage-Transformer.webp\" alt=\"Transformador de Tens\u00e3o JDZ(X)10-10-3610A(REL-10)\" class=\"wp-image-3038\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZX10-10-3610AREL-10-Voltage-Transformer.webp 360w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZX10-10-3610AREL-10-Voltage-Transformer-300x300.webp 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZX10-10-3610AREL-10-Voltage-Transformer-150x150.webp 150w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZX10-10-3610AREL-10-Voltage-Transformer-12x12.webp 12w\" sizes=\"(max-width: 360px) 100vw, 360px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>JDZ(X)10-10-3\u30016\/10A(REL-10) Voltage Transformer Product Overview The JDZ(X)10-10-3\u30016\/10A(REL-10) voltage transformer is a fully enclosed, dry-type, cast-resin voltage transformer designed for 10kV [&hellip;]<\/p>\n","protected":false},"featured_media":3038,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[30],"class_list":["post-1612","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-instrument-transformer-series"],"acf":{"products_imagines":[3038],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/products\/1612","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/media\/3038"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/media\/3038"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/media?parent=1612"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/product_category?post=1612"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}