{"id":611,"date":"2026-01-26T05:15:25","date_gmt":"2026-01-26T05:15:25","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=611"},"modified":"2026-09-14T01:48:44","modified_gmt":"2026-09-14T01:48:44","slug":"ch3-24kv-225-630-1600a-contact-box","status":"publish","type":"products","link":"https:\/\/yieou.com\/pt_br\/product\/ch3-24kv-225-630-1600a-contact-box\/","title":{"rendered":"Caixa de Contato CH3-24kV\/225 630-1600A para Quadros de M\u00e9dia Tens\u00e3o Extra\u00edveis (Montagem Central)"},"content":{"rendered":"<h3 class=\"wp-block-heading\">Vis\u00e3o Geral do Produto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/pt_br\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">A caixa de contatos CH3-24kV\/225 630-1600A para aparelhagem de manobra isolada a v\u00e1cuo extra\u00edvel montada centralmente<\/a> \u00e9 fabricado utilizando um processo de resina ep\u00f3xi APG (Gelifica\u00e7\u00e3o Autom\u00e1tica por Press\u00e3o) com uma estrutura de moldagem por gelifica\u00e7\u00e3o sob press\u00e3o. \u00c9 um dispositivo de conex\u00e3o isolante dedicado para extra\u00edveis tipo caminh\u00e3o da classe de 24kV <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a>, aplicado principalmente em instala\u00e7\u00f5es de pain\u00e9is de manobra extra\u00edveis montados centralmente da classe de 24kV. O dispositivo desempenha as fun\u00e7\u00f5es de isolamento isolante e transi\u00e7\u00e3o de conex\u00e3o, proporcionando prote\u00e7\u00e3o de isolamento eficaz para os contatos internos do painel de manobra. \u00c9 adequado para aplica\u00e7\u00f5es de transmiss\u00e3o de energia de corrente m\u00e9dia, garantindo a opera\u00e7\u00e3o segura e est\u00e1vel dos sistemas de energia el\u00e9trica.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Escopo de Aplica\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This contact box is applicable to 24kV class truck-type withdrawable switchgear and is commonly found in power distribution systems, industrial substations, high-rise building distribution rooms, mining and industrial enterprise distribution systems, and similar electrical installations. It functions as an insulation protection and connection transition component for internal switchgear contacts, providing reliable insulation assurance for the switching and isolation of high-voltage circuits, and accommodating medium-current power transmission requirements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Condi\u00e7\u00f5es de Opera\u00e7\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A altitude de instala\u00e7\u00e3o n\u00e3o deve exceder 1000 m acima do n\u00edvel do mar;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ambient air temperature: -10\u00b0C to +40\u00b0C; relative humidity shall not exceed 95% at 20\u00b0C;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The installation site shall be free from gases, vapors, dust, and other explosive or corrosive media that could significantly degrade the insulation performance of the contact box;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The device shall be installed in locations free from severe vibration and mechanical shock, to ensure structural integrity of the product;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Adequado para instala\u00e7\u00e3o interna; compat\u00edvel com configura\u00e7\u00f5es padr\u00e3o de montagem em barramento.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Recursos do Produto<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Superior insulation performance: Formed using the epoxy resin APG process, the product exhibits excellent insulation properties, effectively isolating high-voltage circuits and preventing leakage and short-circuit risks, with high resistance to impulse overvoltage;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Robust and durable structure: The monolithic molded construction provides high mechanical strength, capable of withstanding both mechanical and electrical stresses within the switchgear enclosure, resulting in an extended service life;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Well-controlled temperature rise: Under continuous rated current operation, the temperature rise at the terminal outlet does not exceed 65\u00b0C, effectively ensuring safe equipment operation and preventing faults caused by excessive temperature rise;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Easy installation: Standardized mounting dimensions compatible with conventional 24kV centrally-mounted switchgear, facilitating on-site installation and replacement;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Corrosion and oxidation resistance: The epoxy resin material provides excellent resistance to corrosion and oxidation, enabling reliable performance across a wide range of demanding electrical environments;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Excellent surface finish: Smooth, burr-free surface for convenient installation, with good flame-retardant and wear-resistant characteristics.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Par\u00e2metros T\u00e9cnicos<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Par\u00e2metro<\/th><th>Especifica\u00e7\u00e3o<\/th><\/tr><\/thead><tbody><tr><td>Tens\u00e3o Nominal<\/td><td>24 kV<\/td><\/tr><tr><td>Corrente Nominal<\/td><td>630 A \u2013 1600 A<\/td><\/tr><tr><td>Tens\u00e3o de Suporte \u00e0 Frequ\u00eancia da Rede<\/td><td>55 kV \/ 1 min<\/td><\/tr><tr><td>Tens\u00e3o de Suporte a Impulso de Corrente de Fuga<\/td><td>125 kV<\/td><\/tr><tr><td>Temperatura de Transi\u00e7\u00e3o V\u00edtrea<\/td><td>\u2265 105\u00b0C<\/td><\/tr><tr><td>Dist\u00e2ncia de escoamento<\/td><td>520 mm<\/td><\/tr><tr><td>Dist\u00e2ncia entre Centros de Montagem<\/td><td>225 mm<\/td><\/tr><tr><td>Limite de Aumento de Temperatura<\/td><td>Terminal outlet temperature rise not exceeding 65\u00b0C at rated current<\/td><\/tr><tr><td>Material<\/td><td>Caixa de resina ep\u00f3xi + contatos de liga de cobre<\/td><\/tr><tr><td>Classifica\u00e7\u00e3o de Prote\u00e7\u00e3o de Ingresso<\/td><td>IP67<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"324\" height=\"324\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CH3-24kV-225-630-1600A-Contact-Box-for-Withdrawable-Medium-Voltage-Center-mounted-Switchgear.png\" alt=\"CH3-24kV-225-630-1600A-Caixa de Contato\" class=\"wp-image-612\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CH3-24kV-225-630-1600A-Contact-Box-for-Withdrawable-Medium-Voltage-Center-mounted-Switchgear.png 324w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CH3-24kV-225-630-1600A-Contact-Box-for-Withdrawable-Medium-Voltage-Center-mounted-Switchgear-300x300.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/CH3-24kV-225-630-1600A-Contact-Box-for-Withdrawable-Medium-Voltage-Center-mounted-Switchgear-150x150.png 150w\" sizes=\"(max-width: 324px) 100vw, 324px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The CH3-24kV\/225 630-1600A contact box for withdrawable centrally-mounted switchgear is manufactured using an epoxy resin APG (Automatic Pressure [&hellip;]<\/p>\n","protected":false},"featured_media":612,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[34],"class_list":["post-611","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-insulation-components-series"],"acf":{"products_imagines":[612,613],"short_describe":"<p><span style=\"color: #334155; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif; font-size: 16px; white-space: pre-wrap;\">The CH3-24kV\/225 630-1600A contact box for withdrawable centrally-mounted switchgear is manufactured using an epoxy resin APG (Automatic Pressure Gelation) process with a pressure gel molding structure.<\/span><\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/products\/611","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/media\/613"},{"embeddable":true,"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/media\/612"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/media\/612"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/media?parent=611"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/pt_br\/wp-json\/wp\/v2\/product_category?post=611"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}