{"id":1557,"date":"2026-05-08T00:00:00","date_gmt":"2026-05-08T00:00:00","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1557"},"modified":"2026-09-16T07:45:02","modified_gmt":"2026-09-16T07:45:02","slug":"jy-mp-15kv-200a-multi-circuit-busbar","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/jy-mp-15kv-200a-multi-circuit-busbar\/","title":{"rendered":"JY MP\u25a1-15kV 200A viacv\u00f4dov\u00e1 zbernica"},"content":{"rendered":"<p class=\"wp-block-paragraph\">JY MP\u25a1-15kV 200A \ub2e4\ud68c\ub85c \uc811\ud569 \ubc84\uc2a4\ubc14<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Preh\u013ead produktu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">JY MP\u25a1-15kV 200A viacv\u00f4dov\u00e1 zbernica<\/a> (dostupn\u00e9 v 2-cestn\u00fdch \/ 3-cestn\u00fdch \/ viaccestn\u00fdch konfigur\u00e1ci\u00e1ch, zbernicov\u00fd odpojovac\u00ed spoj) je odpojite\u013en\u00e9 k\u00e1blov\u00e9 spojovacie pr\u00edslu\u0161enstvo navrhnut\u00e9 pre strednonap\u00e4\u0165ov\u00e9 distribu\u010dn\u00e9 syst\u00e9my 15 kV (trieda 10 kV). V\u010faka plne izolovan\u00e9mu, plne utesnen\u00e9mu a dotykovo bezpe\u010dn\u00e9mu vyhotoveniu umo\u017e\u0148uje paraleln\u00e9 pripojenie zbern\u00edc pre viacero k\u00e1blov\u00fdch rozhran\u00ed. Kompatibiln\u00e9 s lak\u0165ov\u00fdmi k\u00e1blov\u00fdmi konektormi, prep\u00e4\u0165ov\u00fdmi odp\u00edna\u010dmi, uzem\u0148ovac\u00edmi zariadeniami a in\u00fdm pr\u00edslu\u0161enstvom, tvor\u00ed \"viaccestn\u00e9 paraleln\u00e9\" distribu\u010dn\u00e9 rozhranie, ktor\u00e9 integruje funkcie izola\u010dn\u00e9ho odpojenia, pripojenia zbern\u00edc a zemnej ochrany. \u0160iroko pou\u017e\u00edvan\u00e9 v prstencov\u00fdch hlavn\u00fdch jednotk\u00e1ch, transform\u00e1torov\u00fdch staniciach na podlo\u017ek\u00e1ch, k\u00e1blov\u00fdch spojovac\u00edch skriniach a podobn\u00fdch zariadeniach sl\u00fa\u017ei ako kritick\u00e1 s\u00fa\u010das\u0165 pre paraleln\u00e9 pripojenie veden\u00ed a zber pr\u00fadu v strednonap\u00e4\u0165ov\u00fdch distribu\u010dn\u00fdch syst\u00e9moch.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Funkcie produktu<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Elektrick\u00fd a izola\u010dn\u00fd v\u00fdkon<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vyroben\u00e9 z vysoko \u010distej EPDM (etyl\u00e9n-propyl\u00e9n-di\u00e9nov\u00fd monom\u00e9r) gumy met\u00f3dou integr\u00e1lneho vstrekovania, bez \u0161vov alebo vzduchov\u00fdch medzier, \u010d\u00edm poskytuje vynikaj\u00faci izola\u010dn\u00fd v\u00fdkon. Schopn\u00e9 odola\u0165 menovit\u00e9mu nap\u00e4tiu a prechodn\u00e9mu prep\u00e4tiu syst\u00e9mov 15 kV, sp\u013a\u0148aj\u00face po\u017eiadavku maxim\u00e1lneho prev\u00e1dzkov\u00e9ho nap\u00e4tia 17,5 kV pre syst\u00e9my 10 kV s dostato\u010dnou izola\u010dnou rezervou.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zah\u0155\u0148a vn\u00fatorn\u00fa \u0161trukt\u00faru optimaliz\u00e1cie elektrick\u00e9ho po\u013ea a vrstvu kontroly nap\u00e4tia na dosiahnutie rovnomern\u00e9ho rozlo\u017eenia po\u013ea a \u00fa\u010dinn\u00e9 potla\u010denie \u010diasto\u010dn\u00fdch v\u00fdbojov. Dlhodob\u00e1 prev\u00e1dzka nepredstavuje riziko elektrickej er\u00f3zie alebo dielektrick\u00e9ho prelomu; \u00farove\u0148 \u010diasto\u010dn\u00fdch v\u00fdbojov \u226410 pC (pri 1,5U\u2080).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vn\u00fatorn\u00e1 meden\u00e1 zbernica pon\u00faka vynikaj\u00facu vodivos\u0165, n\u00edzky prechodov\u00fd odpor, minim\u00e1lne generovanie tepla pri dlhodobej prev\u00e1dzke a vynikaj\u00facu odolnos\u0165 proti kor\u00f3zii a oxid\u00e1cii. Schopn\u00e1 s\u00fa\u010dasne pren\u00e1\u0161a\u0165 200 A cez viacero obvodov so stabiln\u00fdm elektrick\u00fdm v\u00fdkonom.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kompatibiln\u00e9 s uzem\u0148ovac\u00edmi v\u00fdvodmi na zaistenie spo\u013eahliv\u00e9ho uzemnenia, efekt\u00edvne rozpty\u013euj\u00face pr\u00fadov\u00e9 chyby a indukovan\u00e9 nap\u00e4tia, \u010d\u00edm zvy\u0161uj\u00fa bezpe\u010dnos\u0165 syst\u00e9mu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kon\u0161truk\u010dn\u00e9 a bezpe\u010dnostn\u00e9 prvky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Plne izolovan\u00e1, plne utesnen\u00e1, dotykovo bezpe\u010dn\u00e1 kon\u0161trukcia poskytuje vysok\u00fa integritu vonkaj\u0161ej izol\u00e1cie. Vonkaj\u0161\u00ed povrch sa m\u00f4\u017ee dot\u00fdka\u0165 po\u010das prev\u00e1dzky pod nap\u00e4t\u00edm bez rizika \u00farazu elektrick\u00fdm pr\u00fadom, \u010d\u00edm sa zabezpe\u010duje bezpe\u010dnos\u0165 prev\u00e1dzkov\u00e9ho a \u00fadr\u017ebov\u00e9ho person\u00e1lu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Integrovan\u00fd viacokruhov\u00fd dizajn je k dispoz\u00edcii v 2-cestn\u00fdch, 3-cestn\u00fdch, 4-cestn\u00fdch a in\u00fdch konfigur\u00e1ci\u00e1ch. Kompatibiln\u00fd so \u0161tandardn\u00fdmi americk\u00fdmi \/ eur\u00f3pskymi rozhraniami priechodiek zariaden\u00ed 15kV umo\u017e\u0148uje s\u00fa\u010dasn\u00e9 pripojenie viacer\u00fdch k\u00e1blov\u00fdch pr\u00edslu\u0161enstiev na zber pr\u00fadu zo siete. Kompaktn\u00e1 kon\u0161trukcia umo\u017e\u0148uje pohodln\u00fa in\u0161tal\u00e1ciu bez dodato\u010dn\u00fdch adapt\u00e9rov\u00fdch komponentov.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Proti nespr\u00e1vnemu zapojeniu a pripojeniu s normalizovan\u00fdmi rozmermi rozhrania zais\u0165uje kompatibilitu iba s pr\u00edslu\u0161enstvom zodpovedaj\u00faceho hodnotenia, \u010d\u00edm sa zabr\u00e1ni zmie\u0161aniu r\u00f4znych hodnoten\u00ed. Integrovan\u00fd mechanizmus polohovania a uzamykania zabra\u0148uje uvo\u013eneniu alebo odpojeniu po in\u0161tal\u00e1cii.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Racion\u00e1lne rozlo\u017eenie rozhrania poskytuje dostato\u010dn\u00fd prev\u00e1dzkov\u00fd priestor, \u010do umo\u017e\u0148uje pohodln\u00e9 vkladanie a vyberanie pr\u00edslu\u0161enstva bez \u0161pecializovan\u00fdch n\u00e1strojov na in\u0161tal\u00e1ciu a \u00fadr\u017ebu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Environment\u00e1lna a poveternostn\u00e1 odolnos\u0165<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vynikaj\u00faca odolnos\u0165 vo\u010di poveternostn\u00fdm vplyvom v \u0161irokom rozsahu tepl\u00f4t od -40 \u00b0C do +90 \u00b0C, bez zn\u00ed\u017eenia pru\u017enosti gumy alebo izola\u010dn\u00e9ho v\u00fdkonu pri extr\u00e9mnych teplot\u00e1ch a bez rizika praskania alebo krehnutia. Vhodn\u00e9 pre vonkaj\u0161ie aj vn\u00fatorn\u00e9 pou\u017eitie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Odoln\u00e9 proti vlhkosti, vode, prachu a so\u013enej hmle s kryt\u00edm IP67. Schopn\u00e9 nepretr\u017eitej stabilnej prev\u00e1dzky v n\u00e1ro\u010dn\u00fdch prostrediach vr\u00e1tane zakopan\u00fdch, vlhk\u00fdch a pra\u0161n\u00fdch podmienok, bez vplyvu vniknutia da\u017e\u010fovej vody alebo kondenz\u00e1cie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Proti starnutiu, odoln\u00e9 vo\u010di UV \u017eiareniu a oz\u00f3novej kor\u00f3zii, so \u017eivotnos\u0165ou presahuj\u00facou 30 rokov. Bez\u00fadr\u017ebov\u00e1 prev\u00e1dzka zni\u017euje dlhodob\u00e9 prev\u00e1dzkov\u00e9 n\u00e1klady.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mechanick\u00e9 a kompatibiln\u00e9 funkcie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vysok\u00e1 mechanick\u00e1 pevnos\u0165 s odolnos\u0165ou proti n\u00e1razom a vibr\u00e1ci\u00e1m. Schopnos\u0165 odol\u00e1va\u0165 mechanick\u00e9mu nam\u00e1haniu po\u010das prepravy, in\u0161tal\u00e1cie a prev\u00e1dzky bez rizika deform\u00e1cie alebo po\u0161kodenia. Stupe\u0148 seizmickej odolnosti: Trieda 8.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kompatibiln\u00e9 so \u0161tandardn\u00fdmi rozhraniami priechodiek zariaden\u00ed 15kV 200A. Ka\u017ed\u00e1 v\u00fdstupn\u00e1 svorka obvodu je univerz\u00e1lne zamenite\u013en\u00e1 s koncovkami k\u00e1blov, prep\u00e4\u0165ov\u00fdmi odp\u00edna\u010dmi a uzem\u0148ovac\u00edmi zariadeniami rovnakej triedy, \u010do poskytuje siln\u00fa univerz\u00e1lnos\u0165.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0160tandardizovan\u00e9 rozhrania vyhovuj\u00face norme IEEE 386 a relevantn\u00fdm dom\u00e1cim norm\u00e1m. Kompatibiln\u00e9 s rozhraniami priechodiek hlavn\u00fdch 15kV prstencov\u00fdch skr\u00ed\u0148, transform\u00e1torov\u00fdch stan\u00edc na podlo\u017eke a k\u00e1blov\u00fdch spojovac\u00edch skr\u00ed\u0148 na splnenie po\u017eiadaviek viacokruhov\u00fdch zbern\u00edc.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Technick\u00e9 parametre<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Kateg\u00f3ria parametra<\/td><td>Predmet<\/td><td>Technick\u00e1 \u0161pecifik\u00e1cia<\/td><\/tr><tr><td>Menovit\u00e9 elektrick\u00e9 parametre<\/td><td>Menovit\u00e9 nap\u00e4tie (Ue)<\/td><td>15kV (vz\u0165ahuje sa na syst\u00e9my 10kV; maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie 17,5kV)<\/td><\/tr><tr><td><\/td><td>Menovit\u00fd pr\u00fad (Ie)<\/td><td>200A (na obvod); viacobvodov\u00e1 paraleln\u00e1 prev\u00e1dzka<\/td><\/tr><tr><td><\/td><td>Menovit\u00e1 frekvencia (fn)<\/td><td>50\u8d6b\u5179 \/ 60\u8d6b\u5179<\/td><\/tr><tr><td><\/td><td>| V\u00fdkonov\u00e9 frekven\u010dn\u00e9 odoln\u00e9 nap\u00e4tie<\/td><td>42kV \/ 5 min (such\u00fd test), 38kV \/ 5 min (mokr\u00fd test); bez prierazu, bez preskoku<\/td><\/tr><tr><td><\/td><td>| Nap\u00e4tie pri odolnosti vo\u010di impulzn\u00e9mu prep\u00e4tiu<\/td><td>95kV (\u0161pi\u010dkov\u00e9); bez pr\u016frazu, bez p\u0159eskok\u016f<\/td><\/tr><tr><td><\/td><td>\u00darove\u0148 \u010diasto\u010dn\u00e9ho v\u00fdboja<\/td><td>\u226410 pC (pri 1,5U\u2080)<\/td><\/tr><tr><td><\/td><td>| Menovit\u00fd skratov\u00fd v\u00fddr\u017en\u00fd pr\u00fad<\/td><td>16kA \/ 2s (volite\u013en\u00e9: 20kA \/ 2s, prisp\u00f4soben\u00e9 po\u017eiadavk\u00e1m syst\u00e9mu)<\/td><\/tr><tr><td><\/td><td>| Odpor kontaktu<\/td><td>\u2264100 \u03bc\u03a9 (na obvod)<\/td><\/tr><tr><td>Kon\u0161truk\u010dn\u00e9 a materi\u00e1lov\u00e9 parametre<\/td><td>Materi\u00e1l hlavn\u00e9ho tela<\/td><td>EPDM guma (izola\u010dn\u00e1 vrstva); poc\u00ednovan\u00e1 me\u010f (zbernica \/ vodiv\u00e9 kontaktn\u00e9 komponenty)<\/td><\/tr><tr><td><\/td><td>| Hodnotenie ochrany<\/td><td>IP67<\/td><\/tr><tr><td><\/td><td>| Rozhranie \u0161tandard<\/td><td>1 vstupn\u00fd termin\u00e1l (rozhranie priechodky americk\u00e9ho \u0161tandardu 15kV); viacero v\u00fdstupn\u00fdch termin\u00e1lov (\u0161tandardn\u00e9 rozhrania pr\u00edslu\u0161enstva 15kV 200A)<\/td><\/tr><tr><td><\/td><td>Met\u00f3da uzemnenia<\/td><td>Kompatibiln\u00e9 so \u017eltozelen\u00fdm dvojfarebn\u00fdm uzem\u0148ovac\u00edm v\u00fdvodov\u00fdm vodi\u010dom pre priame uzemnenie<\/td><\/tr><tr><td>Environment\u00e1lne parametre<\/td><td>Pou\u017eite\u013en\u00e1 v\u00fd\u0161ka<\/td><td>\u22642 000 m (dostupn\u00e9 prisp\u00f4sobenie pre vysok\u00fa nadmorsk\u00fa v\u00fd\u0161ku)<\/td><\/tr><tr><td><\/td><td>| Okolit\u00e1 teplota<\/td><td>-40 \u00b0C a\u017e +90 \u00b0C (prev\u00e1dzkov\u00e1); -40 \u00b0C a\u017e +70 \u00b0C (skladovacia)<\/td><\/tr><tr><td><\/td><td>Relat\u00edvna vlhkos\u0165<\/td><td>\u2264100% (nekondenzuj\u00faca)<\/td><\/tr><tr><td><\/td><td>| Hodnotenie seizmickej odolnosti<\/td><td>8. ro\u010dn\u00edk<\/td><\/tr><tr><td>Platn\u00e9 normy<\/td><td><\/td><td>IEEE 386, GB\/T 12706, DL\/T 404, GB\/T 11022<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Rozsah pou\u017eitia<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pou\u017eite\u013en\u00e1 trieda nap\u00e4tia: 10kV a\u017e 15kV strednonap\u00e4\u0165ov\u00e9 distribu\u010dn\u00e9 syst\u00e9my striedav\u00e9ho pr\u00fadu, kompatibiln\u00e9 s rozhraniami priechodiek zariaden\u00ed dimenzovan\u00fdmi na maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie 17,5kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pou\u017eite\u013en\u00e9 vybavenie a scen\u00e1re:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rozhrania priechodiek 15kV vn\u00fatorn\u00fdch rozvodn\u00ed, transform\u00e1torov\u00fdch stan\u00edc na podstavci, k\u00e1blov\u00fdch odbo\u010dn\u00fdch skr\u00ed\u0148, americk\u00fdch transform\u00e1torov na podstavci a podobn\u00fdch distribu\u010dn\u00fdch zariaden\u00ed, umo\u017e\u0148uj\u00face zber pr\u00fadu z viacer\u00fdch obvodov;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Used in conjunction with elbow cable connectors, surge arresters, and grounding devices to form multi-circuit cable terminations and multi-circuit surge <a href=\"https:\/\/en.wikipedia.org\/wiki\/Lightning_arrester\" target=\"_blank\" rel=\"noopener\">prep\u00e4\u0165ov\u00e1 ochrana<\/a> interfaces;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mestsk\u00e9 distribu\u010dn\u00e9 sie\u0165ov\u00e9 k\u00e1blov\u00e9 vedenia, distribu\u010dn\u00e9 syst\u00e9my priemyseln\u00fdch a bansk\u00fdch podnikov a distribu\u010dn\u00e9 rozhrania na zv\u00fd\u0161ovac\u00edch transform\u00e1torov\u00fdch staniciach obnovite\u013en\u00fdch zdrojov energie (fotovoltaika \/ veternej energie);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Izolovan\u00e9 priechodkov\u00e9 spoje pre zariadenia v vn\u00fatorn\u00fdch \/ vonkaj\u0161\u00edch distribu\u010dn\u00fdch miestnostiach, podzemn\u00fdch in\u017einierskych tuneloch, k\u00e1blov\u00fdch tuneloch a in\u00fdch viac\u00fa\u010delov\u00fdch aplik\u00e1ci\u00e1ch, sp\u013a\u0148aj\u00face po\u017eiadavky na zbernicov\u00e9 a odbo\u010dn\u00e9 vedenia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Funk\u010dn\u00fd \u00fa\u010del: Poskytuje izolovan\u00e9, utesnen\u00e9, paraleln\u00e9 pripojenia zbern\u00edc medzi v\u00fdvodmi zariaden\u00ed a viacer\u00fdmi k\u00e1blov\u00fdmi pr\u00edslu\u0161enstvami. Zah\u0155\u0148a funkcie ochrany uzemnenia, izol\u00e1cie a zberu pr\u00fadu vedenia, \u010d\u00edm poskytuje bezpe\u010dn\u00e9 a spo\u013eahliv\u00e9 viacn\u00e1sobn\u00e9 paraleln\u00e9 rozhranie pre distribu\u010dn\u00e9 syst\u00e9my.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160tandardn\u00e9 prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fd\u0161ka: \u22642 000 m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okolit\u00e1 teplota: -40 \u00b0C a\u017e +90 \u00b0C; prev\u00e1dzkov\u00e1 teplota zariadenia v s\u00falade s platn\u00fdmi normami;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Relat\u00edvna vlhkos\u0165: \u2264100 % (nekondenzuj\u00faca);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podmienky prostredia: bez koroz\u00edvnych plynov, hor\u013eav\u00fdch alebo v\u00fdbu\u0161n\u00fdch m\u00e9di\u00ed a siln\u00fdch vibr\u00e1ci\u00ed alebo otrasov;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sp\u00f4sob in\u0161tal\u00e1cie: kompatibiln\u00fd so \u0161tandardn\u00fdmi rozhraniami puzdier zariaden\u00ed; povolen\u00e1 horizont\u00e1lna alebo vertik\u00e1lna mont\u00e1\u017e; in\u0161tala\u010dn\u00fd priestor mus\u00ed zodpoveda\u0165 prev\u00e1dzkov\u00fdm po\u017eiadavk\u00e1m v\u0161etk\u00e9ho s\u00favisiaceho pr\u00edslu\u0161enstva.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160peci\u00e1lne prev\u00e1dzkov\u00e9 podmienky (vy\u017eaduje sa prisp\u00f4sobenie)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nadmo\u0159sk\u00e1 v\u00fd\u0161ka p\u0159esahuj\u00edc\u00ed 2 000 m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okolit\u00e1 teplota mimo rozsah -40 \u00b0C a\u017e +90 \u00b0C;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Silne zanieczyszczone, nara\u017cone na dzia\u0142anie mg\u0142y solnej lub agresywnych \u015brodk\u00f3w chemicznych;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Siln\u00e9 vibr\u00e1cie alebo prev\u00e1dzkov\u00e9 podmienky s vysok\u00fdmi n\u00e1razmi;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nestandardn\u00e9 rozmery rozhrania priechodky zariadenia;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0160peci\u00e1lne uzem\u0148ovacie po\u017eiadavky alebo aplik\u00e1cie s vysokou triedou zne\u010distenia.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">In\u0161tal\u00e1cia a \u00fadr\u017eba<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na in\u0161tal\u00e1ciu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pred in\u0161tal\u00e1ciou skontrolujte v\u00fdrobok zvonku, \u010di nem\u00e1 praskliny, po\u0161kodenia alebo dutiny; overte, \u010di je povrch izol\u00e1cie nepo\u0161koden\u00fd; skontrolujte, \u010di je uzem\u0148ovac\u00ed v\u00fdvod (ak je s\u00fa\u010das\u0165ou dod\u00e1vky) neporu\u0161en\u00fd a bez kor\u00f3zie, a \u010di s\u00fa pr\u00edtomn\u00e9 v\u0161etky pr\u00edslu\u0161enstv\u00e1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vy\u010distite povrch rozhrania priechodky zariadenia, odstr\u00e1\u0148te mazivo, prach a cudzie \u010dastice, aby ste zabezpe\u010dili, \u017ee rozhranie je such\u00e9 a \u010dist\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Na vn\u00fatorn\u00fa stenu vstupn\u00e9ho portu zbernice naneste rovnomern\u00fa vrstvu \u0161pecializovan\u00e9ho silik\u00f3nov\u00e9ho maziva, aby ste zabr\u00e1nili po\u0161kodeniu izola\u010dnej vrstvy po\u010das in\u0161tal\u00e1cie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pomaly zasu\u0148te zbernicu do rozhrania priechodky zariadenia, a\u017e k\u00fdm nebude \u00faplne zasunut\u00e1, potom zaistite polohovac\u00ed z\u00e1mok. Ak je s\u00fa\u010das\u0165ou uzem\u0148ovac\u00ed v\u00fdvod, pripojte ho k uzem\u0148ovacej mrie\u017eke; odpor uzemnenia \u22644 \u03a9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pripojte ka\u017ed\u00fd v\u00fdstupn\u00fd termin\u00e1l obvodu k zodpovedaj\u00facemu kolenn\u00e9mu k\u00e1blu <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" target=\"_blank\" rel=\"noopener\">konektor<\/a>, n\u00e1val <a href=\"https:\/\/en.wikipedia.org\/wiki\/Lightning_arrester\" target=\"_blank\" rel=\"noopener\">prep\u00e4\u0165ov\u00e1 ochrana<\/a>, or other accessory of the appropriate rating, ensuring accessories are fully seated and anti-withdrawal devices are engaged.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po dokon\u010den\u00ed in\u0161tal\u00e1cie vykonajte sk\u00fa\u0161ku izola\u010dn\u00e9ho odporu a sk\u00fa\u0161ku odolnosti vo\u010di nap\u00e4tiu pri frekvencii siete; jednotka m\u00f4\u017ee by\u0165 nap\u00e1jan\u00e1 a\u017e po \u00faspe\u0161nom absolvovan\u00ed t\u00fdchto sk\u00fa\u0161ok.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na \u00fadr\u017ebu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pravidelne kontrolujte zbernicu zvonka, \u010di na nej nie s\u00fa praskliny, zn\u00e1mky v\u00fdboja alebo nahromaden\u00e9 ne\u010distoty; overte, \u010di je uzem\u0148ovac\u00ed v\u00fdvod a v\u0161etky pripojenia obvodov\u00fdch pr\u00edslu\u0161enstiev pevn\u00e9 a neuvo\u013enen\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pravidelne testujte izola\u010dn\u00fd odpor, aby ste zabezpe\u010dili, \u017ee v\u00fdkon sp\u013a\u0148a po\u017eiadavky a aby ste v\u010das identifikovali skryt\u00e9 chyby.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vy\u010distite povrch zbernice od prachu a ne\u010dist\u00f4t, pri\u010dom udr\u017eujte izola\u010dn\u00fd povrch such\u00fd a \u010dist\u00fd; vyh\u00fdbajte sa kontaktu s mastnotou a chemick\u00fdmi l\u00e1tkami.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ak sa na zbernicovej li\u0161te alebo akomko\u013evek pridru\u017eenom pr\u00edslu\u0161enstve prejavia praskliny, po\u0161kodenia, v\u00fdboje alebo abnorm\u00e1lne zahrievanie, okam\u017eite odpojte nap\u00e1janie a vyme\u0148te po\u0161koden\u00fa s\u00fa\u010diastku. Pokra\u010dovanie prev\u00e1dzky v pr\u00edpade poruchy je pr\u00edsne zak\u00e1zan\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vkladanie a vyberanie pr\u00edslu\u0161enstva sa mus\u00ed vykon\u00e1va\u0165 pomocou \u0161pecializovan\u00fdch izolovan\u00fdch prev\u00e1dzkov\u00fdch n\u00e1strojov. Priamy dotyk r\u00fak so zapnut\u00fdmi konektormi je pr\u00edsne zak\u00e1zan\u00fd. V\u0161etky oper\u00e1cie sa musia pr\u00edsne dodr\u017eiava\u0165 pod\u013ea predpisov o bezpe\u010dnosti distribu\u010dn\u00e9ho syst\u00e9mu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Opatrenia<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In\u0161tal\u00e1ciu, uvedenie do prev\u00e1dzky a \u00fadr\u017ebu musia vykon\u00e1va\u0165 v\u00fdlu\u010dne kvalifikovan\u00ed elektro pracovn\u00edci s pr\u00edslu\u0161n\u00fdm opr\u00e1vnen\u00edm na v\u00fdstavbu strednop\u00e4tov\u00fdch rozvodov. Prev\u00e1dzka neopr\u00e1vnen\u00fdmi osobami je pr\u00edsne zak\u00e1zan\u00e1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobok sa mus\u00ed pou\u017e\u00edva\u0165 iba s obj\u00edmkami zariadenia, koncovkami k\u00e1blov, prep\u00e4\u0165ov\u00fdmi odp\u00edna\u010dmi a in\u00fdm pr\u00edslu\u0161enstvom zodpovedaj\u00faceho menovit\u00e9ho v\u00fdkonu. Kr\u00ed\u017eov\u00e9 nes\u00falad rozhran\u00ed je pr\u00edsne zak\u00e1zan\u00fd, preto\u017ee to povedie k zlyhaniu izol\u00e1cie a bezpe\u010dnostn\u00fdm rizik\u00e1m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zbernicu je zak\u00e1zan\u00e9 rozobera\u0165 alebo upravova\u0165 bez povolenia, preto\u017ee by to viedlo k strate z\u00e1ruky a bezpe\u010dnostnej z\u00e1ruky. Pou\u017e\u00edvanie ne\u0161pecializovan\u00fdch n\u00e1strojov na n\u00e1siln\u00fa mont\u00e1\u017e alebo demont\u00e1\u017e konektorov je pr\u00edsne zak\u00e1zan\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00fabe\u017en\u00e9 pripojenie pr\u00edslu\u0161enstva r\u00f4znych nap\u00e4\u0165ov\u00fdch tried alebo pr\u00fadov\u00fdch hodn\u00f4t k v\u00fdstupn\u00fdm svork\u00e1m obvodu je pr\u00edsne zak\u00e1zan\u00e9; v\u0161etko pr\u00edslu\u0161enstvo mus\u00ed by\u0165 prisp\u00f4soben\u00e9 parametrom syst\u00e9mu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Skladujte v suchom, dobre vetranom, chladnom prostred\u00ed, mimo dosahu priameho slne\u010dn\u00e9ho \u017eiarenia, vysok\u00fdch tepl\u00f4t, vlhkosti a za\u0165a\u017eenia tlakom. Kontakt s ostr\u00fdmi predmetmi, ktor\u00e9 by mohli po\u0161kodi\u0165 izola\u010dn\u00fa vrstvu, je pr\u00edsne zak\u00e1zan\u00fd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V\u0161etky pr\u00e1ce na zariadeniach pod nap\u00e4t\u00edm vr\u00e1tane s\u00favisiaceho pr\u00edslu\u0161enstva sa musia pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distribu\u010dnej s\u00fastavy s primeran\u00fdmi bezpe\u010dnostn\u00fdmi opatreniami. Prev\u00e1dzky, ktor\u00e9 nesp\u013a\u0148aj\u00fa tieto po\u017eiadavky, s\u00fa pr\u00edsne zak\u00e1zan\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ozna\u010denie modelu<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Identifik\u00e1tor modelu<\/td><td>V\u00fdznam<\/td><\/tr><tr><td>JY<\/td><td>Ozna\u010denie produktovej s\u00e9rie<\/td><\/tr><tr><td>\u041c\u041f<\/td><td>Ozna\u010denie radu viacokruhov\u00fdch zbern\u00edc<\/td><\/tr><tr><td>\u25a1<\/td><td>Po\u010det okruhov (2 \/ 3 \/ 4, predstavuj\u00face 2-cestn\u00fd \/ 3-cestn\u00fd \/ 4-cestn\u00fd)<\/td><\/tr><tr><td>15kV<\/td><td>Menovit\u00e9 nap\u00e4tie; kompatibiln\u00e9 so syst\u00e9mami 15kV; maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie 17,5kV<\/td><\/tr><tr><td>200A<\/td><td>Menovit\u00fd pr\u00fadov\u00fd rad; kompatibiln\u00e9 s 200 A na obvod<\/td><\/tr><tr><td>Preru\u0161ovacia zbernica<\/td><td>Preru\u0161ovac\u00ed typ zbernice; viacn\u00e1sobn\u00e9 paraleln\u00e9 izolovan\u00e9 pripojovacie pr\u00edslu\u0161enstvo pre rozhrania priechodiek zariadenia<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Platn\u00e9 normy a certifik\u00e1cie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Medzin\u00e1rodn\u00fd \u0161tandard: IEEE 386, \u0160tandard pre odpojite\u013en\u00e9 izolovan\u00e9 konektorov\u00e9 syst\u00e9my pre distribu\u010dn\u00e9 syst\u00e9my nad 600 V;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e1rodn\u00e9 normy: GB\/T 12706, Silov\u00e9 k\u00e1ble s extrudovanou izol\u00e1ciou a ich pr\u00edslu\u0161enstvo pre menovit\u00e9 nap\u00e4tia od 1 kV (Um = 1,2 kV) do 35 kV (Um = 40,5 kV); GB\/T 11022, Spolo\u010dn\u00e9 \u0161pecifik\u00e1cie pre vysokonap\u00e4\u0165ov\u00e9 <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a> a kontroln\u00fdch zariaden\u00ed; DL\/T 404, striedav\u00e9 kovom uzatv\u00e1ran\u00e9 rozv\u00e1dza\u010de a kontroln\u00e9 zariadenia pre menovit\u00e9 nap\u00e4tia od 3,6 kV do 40,5 kV;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobok \u00faspe\u0161ne absolvoval typov\u00e9 sk\u00fa\u0161ky v N\u00e1rodnom kontrolnom a in\u0161pek\u010dnom centre pre vysokonap\u00e4\u0165ov\u00e9 elektrick\u00e9 zariadenia a sp\u013a\u0148a n\u00e1rodn\u00e9 normy elektrickej bezpe\u010dnosti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Popredajn\u00fd servis<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Z\u00e1ru\u010dn\u00e1 doba produktu: 18 mesiacov od d\u00e1tumu v\u00fdroby, alebo 12 mesiacov od d\u00e1tumu uvedenia do prev\u00e1dzky, pod\u013ea toho, \u010do nastane sk\u00f4r;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bezplatn\u00e1 oprava alebo v\u00fdmena pri z\u00e1vad\u00e1ch kvality v\u00fdrobku v r\u00e1mci z\u00e1ru\u010dnej doby;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Technick\u00e1 podpora, pokyny k in\u0161tal\u00e1cii a slu\u017eby prisp\u00f4sobenia s\u00fa k dispoz\u00edcii (\u0161peci\u00e1lne hodnotenia, prisp\u00f4sobenia pre \u0161peci\u00e1lne prev\u00e1dzkov\u00e9 podmienky).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pozn\u00e1mky k dokumentu<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Technick\u00e9 parametre v tomto n\u00e1vode s\u00fa zalo\u017een\u00e9 na \u0161tandardn\u00fdch prev\u00e1dzkov\u00fdch podmienkach. \u0160peci\u00e1lne prev\u00e1dzkov\u00e9 podmienky si vy\u017eaduj\u00fa prisp\u00f4sobenie na z\u00e1klade skuto\u010dn\u00fdch po\u017eiadaviek. Kone\u010dn\u00fdm referen\u010dn\u00fdm dokumentom je technick\u00e1 dohoda o produkte a spr\u00e1vy z typov\u00fdch sk\u00fa\u0161ok.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pr\u00edloha: N\u00e1kres obrysu produktu<\/p>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>JY MP\u25a1-15kV 200A Multi-Circuit Junction Busbar Product Overview JY MP\u25a1-15kV 200A multi-circuit busbar (available in 2-way \/ 3-way \/ multi-way [&hellip;]<\/p>\n","protected":false},"featured_media":298,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[9],"class_list":["post-1557","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-american-cable-accessories"],"acf":{"products_imagines":[293,294,295,298,297],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/1557","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/297"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/298"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/295"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/294"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/293"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=1557"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=1557"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}