{"id":1620,"date":"2026-05-08T00:00:00","date_gmt":"2026-05-08T00:00:00","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1620"},"modified":"2026-09-16T02:00:52","modified_gmt":"2026-09-16T02:00:52","slug":"voltage-transformers","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/voltage-transformers\/","title":{"rendered":"JDZJ-3, JDZJ-6 \ubc0f JDZJ-10 (W) \uc804\uc555 \ubcc0\uc555\uae30"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Preh\u013ead produktu<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">JDZJ-3, JDZJ-6 \ubc0f JDZJ-10 (W) \uc804\uc555 \ubcc0\uc555\uae30<\/a> jednof\u00e1zov\u00e9, polouzavret\u00e9, such\u00e9 transform\u00e1tory nap\u00e4tia ur\u010den\u00e9 pre vn\u00fatorn\u00e9 a vonkaj\u0161ie silov\u00e9 syst\u00e9my 3 kV, 6 kV a 10 kV striedav\u00e9ho pr\u00fadu s maxim\u00e1lnym nap\u00e4t\u00edm syst\u00e9mu 12 kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vysokonap\u00e4\u0165ov\u00e9 vinutie je izolovan\u00e9 liatou epoxidovou \u017eivic<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pou\u017e\u00edva sa hlavne na meranie nap\u00e4tia, meranie energie, rel\u00e9ov\u00fa ochranu a monitorovanie izol\u00e1cie vo vn\u00fatorn\u00fdch stredn\u00fdch nap\u00e4tiach. <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a>, vonkaj\u0161ie distribu\u010dn\u00e9 zariadenia, skri\u0148ov\u00e9 transform\u00e1torov\u00e9 stanice a in\u00e9 syst\u00e9my distrib\u00facie elektrickej energie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Funkcie produktu<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Izol\u00e1cia a elektrick\u00fd v\u00fdkon<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Epoxidov\u00e1 \u017eivica liata izol\u00e1cia:<\/strong><br>Vysokonap\u00e4\u0165ov\u00e9 vinutie je vytvoren\u00e9 procesom v\u00e1kuov\u00e9ho odlievania epoxidovou \u017eivicou. Odliata izol\u00e1cia neobsahuje \u017eiadne vn\u00fatorn\u00e9 vzduchov\u00e9 medzery a poskytuje vynikaj\u00faci dielektrick\u00fd v\u00fdkon. Dok\u00e1\u017ee odola\u0165 prev\u00e1dzkov\u00e9mu nap\u00e4tiu, nap\u00e4tiu odolnosti vo\u010di sie\u0165ovej frekvencii a nap\u00e4tiu odolnosti vo\u010di impulzn\u00e9mu prep\u00e4tiu zodpovedaj\u00facemu syst\u00e9mu.<\/li>\n\n\n\n<li><strong>Bezolejov\u00e1 kon\u0161trukcia<\/strong><br>Such\u00fd<\/li>\n\n\n\n<li><strong>Viacer\u00e9 nap\u00e4tia:<\/strong><br>Modely s\u00fa dostupn\u00e9 pre syst\u00e9my 3 kV, 6 kV a 10 kV. Nap\u00e4\u0165ov\u00e9 pomery ako 10\/0,1 kV a 6\/0,1 kV je mo\u017en\u00e9 prisp\u00f4sobi\u0165 pod\u013ea po\u017eiadaviek syst\u00e9mu.<\/li>\n\n\n\n<li><strong>Viacer\u00e9 triedy presnosti:<\/strong><br>Pre meracie, ochrann\u00e9 a monitorovacie aplik\u00e1cie izol\u00e1cie s\u00fa k dispoz\u00edcii triedy presnosti merania 0,2, 0,5 a 1 a triedy presnosti ochrany 3P a 6P.<\/li>\n\n\n\n<li><strong>Vysok\u00e1 odolnos\u0165 proti zne\u010disteniu a preskokom<\/strong><br>Vysokonap\u00e4\u0165ov\u00e9 svorky maj\u00fa izola\u010dn\u00fa kon\u0161trukciu typu odkvap, ktor\u00e1 poskytuje spo\u013eahliv\u00fa odolnos\u0165 proti povrchov\u00e9mu preskoku. Vonkaj\u0161\u00ed model typu W je navrhnut\u00fd pre prev\u00e1dzku v zne\u010distenom vonkaj\u0161om prostred\u00ed.<\/li>\n\n\n\n<li><strong>N\u00edzky \u010diasto\u010dn\u00fd v\u00fdboj<\/strong><br>Pokro\u010dil\u00fd proces odlievania poskytuje n\u00edzku \u00farove\u0148 \u010diasto\u010dn\u00fdch v\u00fdbojov, \u010do pom\u00e1ha zni\u017eova\u0165 starnutie izol\u00e1cie a zlep\u0161uje dlhodob\u00fa prev\u00e1dzkov\u00fa spo\u013eahlivos\u0165.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Kon\u0161truk\u010dn\u00e9 a in\u0161tala\u010dn\u00e9 vlastnosti<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Polouzavret\u00e1 such\u00e1 kon\u0161trukcia:<\/strong><br>Vysokonap\u00e4\u0165ov\u00e9 vinutie je zapuzdren\u00e9 v epoxidovej \u017eivici, zatia\u013e \u010do odkryt\u00e1 \u010das\u0165 magnetick\u00e9ho jadra pou\u017e\u00edva vzduchov\u00fa izol\u00e1ciu. Bezolejov\u00fd dizajn nepredstavuje riziko \u00faniku oleja ani po\u017eiaru a poskytuje kompaktn\u00fa celkov\u00fa kon\u0161trukciu.<\/li>\n\n\n\n<li><strong>Modul\u00e1rny dizajn:<\/strong><br>\u0160tandardizovan\u00e9 mont\u00e1\u017ene rozmery robia transform\u00e1tor vhodn\u00fdm pre vn\u00fatorn\u00e9 rozvodn\u00e9 zariadenia a vonkaj\u0161ie energetick\u00e9 distribu\u010dn\u00e9 zariadenia. Vonkaj\u0161ia verzia typu W obsahuje vodotesn\u00e9 a zne\u010disteniu odoln\u00e9 prvky pre exponovan\u00e9 vonkaj\u0161ie in\u0161tal\u00e1cie.<\/li>\n\n\n\n<li><strong>Jasne zidentyfikowane terminale:<\/strong><br>Vysokonap\u00e4\u0165ov\u00e9 svorky s\u00fa zrete\u013ene ozna\u010den\u00e9, zatia\u013e \u010do n\u00edzkonap\u00e4\u0165ov\u00e9 svorky s\u00fa chr\u00e1nen\u00e9 krytom svoriek. Toto usporiadanie zjednodu\u0161uje zapojenie a pom\u00e1ha predch\u00e1dza\u0165 nespr\u00e1vnym pripojeniam a n\u00e1hodn\u00fdm skratom sekund\u00e1rneho obvodu.<\/li>\n\n\n\n<li><strong>Flexibiln\u00e1 in\u0161tal\u00e1cia:<\/strong><br>Kovov\u00e1 z\u00e1klad\u0148a obsahuje mont\u00e1\u017ene otvory na bezpe\u010dn\u00fa in\u0161tal\u00e1ciu pomocou skrutiek. Transform\u00e1tor je mo\u017en\u00e9 nain\u0161talova\u0165 horizont\u00e1lne do vn\u00fatorn\u00fdch rozvodn\u00fdch skr\u00ed\u0148 alebo namontova\u0165 do vonkaj\u0161\u00edch distribu\u010dn\u00fdch zariaden\u00ed. Poskytuje spo\u013eahliv\u00fa odolnos\u0165 vo\u010di vibr\u00e1ci\u00e1m a za\u0165a\u017eeniu vetrom.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Prev\u00e1dzkov\u00e9 a \u00fadr\u017ebov\u00e9 funkcie<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>N\u00edzko\u00fadr\u017ebov\u00e1 prev\u00e1dzka:<\/strong><br>Such\u00e1, bezolejov\u00e1 kon\u0161trukcia eliminuje riziko \u00faniku a po\u017eiaru s\u00favisiaceho s olejom. Telo z epoxidovej \u017eivice poskytuje vysok\u00fa mechanick\u00fa pevnos\u0165, odolnos\u0165 proti n\u00e1razom a starnutiu, \u010d\u00edm zni\u017euje n\u00e1roky na be\u017en\u00fa \u00fadr\u017ebu.<\/li>\n\n\n\n<li><strong>\u0160irok\u00fd rozsah prev\u00e1dzkov\u00fdch tepl\u00f4t:<\/strong><br>Transform\u00e1tor m\u00f4\u017ee pracova\u0165 pri okolit\u00fdch teplot\u00e1ch od -30\u00b0C do +70\u00b0C. Epoxidov\u00e1 \u017eivica si zachov\u00e1va stabiln\u00e9 izola\u010dn\u00e9 a mechanick\u00e9 vlastnosti bez krehnutia alebo deform\u00e1cie. Vonkaj\u0161\u00ed model odol\u00e1va v\u00fdznamn\u00fdm teplotn\u00fdm v\u00fdkyvom medzi d\u0148om a nocou.<\/li>\n\n\n\n<li><strong>Dizajn s vysokou spo\u013eahlivos\u0165ou:<\/strong><br>Vinutia s\u00fa vyroben\u00e9 z meden\u00e9ho dr\u00f4tu izolovan\u00e9ho smaltom a magnetick\u00e9 jadro je skon\u0161truovan\u00e9 z vysokokvalitn\u00fdch plechov z krem\u00edkovej ocele. V\u00fdrobok poskytuje n\u00edzke prev\u00e1dzkov\u00e9 straty, obmedzen\u00fd n\u00e1rast teploty a stabiln\u00fa presnos\u0165 merania.<\/li>\n\n\n\n<li><strong>Schopnos\u0165 odol\u00e1va\u0165 prep\u00e4tiu:<\/strong><br>Transform\u00e1tor odol\u00e1 sp\u00ednac\u00edm a atmosf\u00e9rick\u00fdm prep\u00e4tiam v r\u00e1mci svojej \u0161pecifikovanej \u00farovne izol\u00e1cie, \u010d\u00edm zabezpe\u010duje stabiln\u00e9 meracie a ochrann\u00e9 sign\u00e1ly.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Technical Specifications<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Elektrick\u00e9 parametre<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>\u0160pecifik\u00e1cia<\/th><\/tr><\/thead><tbody><tr><td>Pou\u017eite\u013en\u00e9 nap\u00e4tie syst\u00e9mu<\/td><td>3 kV \/ 6 kV \/ 10 kV AC, Um = 12 kV<\/td><\/tr><tr><td>Menovit\u00e1 frekvencia<\/td><td>50 Hz<\/td><\/tr><tr><td>Menovit\u00e9 prim\u00e1rne nap\u00e4tie<\/td><td>3 kV \/ 6 kV \/ 10 kV, prisp\u00f4sobite\u013en\u00e9<\/td><\/tr><tr><td>Menovit\u00e9 sekund\u00e1rne nap\u00e4tie<\/td><td>100 V na meranie a ochranu; 100\/3 V na volite\u013en\u00e9 monitorovanie izol\u00e1cie<\/td><\/tr><tr><td>Triednos\u0165 merania<\/td><td>Trieda 0,2 \/ 0,5 \/ 1<\/td><\/tr><tr><td>Triednos\u0165 ochrany<\/td><td>3P \/ 6P<\/td><\/tr><tr><td>Nap\u00e4\u0165ov\u00e1 sk\u00fa\u0161ka s frekvenciou siete<\/td><td>3 kV syst\u00e9m: 18 kV; 6 kV syst\u00e9m: 24 kV; 10 kV syst\u00e9m: 42 kV po dobu 1 min\u00faty, bez prierazu<\/td><\/tr><tr><td>Impulzn\u00e1 odolnos\u0165 vo\u010di prep\u00e4tiu<\/td><td>3 kV syst\u00e9m: 40 kV; 6 kV syst\u00e9m: 60 kV; 10 kV syst\u00e9m: 75 kV \u0161pi\u010dkov\u00e9, bez pr\u016frazu<\/td><\/tr><tr><td>\u010ciasto\u010dn\u00fd v\u00fdboj<\/td><td>\u226410 pC<\/td><\/tr><tr><td>Izola\u010dn\u00fd odpor<\/td><td>\u22651,000 M\u03a9 between high voltage, low voltage, and earth<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Kon\u0161truk\u010dn\u00e9 a materi\u00e1lov\u00e9 parametre<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>\u0160pecifik\u00e1cia<\/th><\/tr><\/thead><tbody><tr><td>Izola\u010dn\u00fd materi\u00e1l<\/td><td>Epoxidov\u00e1 \u017eivica a vzduchov\u00e1 izol\u00e1cia<\/td><\/tr><tr><td>Ochrann\u00e9 hodnotenie<\/td><td>IP20 pre vn\u00fatorn\u00e9 modely; IP34 pre vonkaj\u0161ie modely typu W<\/td><\/tr><tr><td>Typ in\u0161tal\u00e1cie<\/td><td>Vn\u00fatorn\u00e9 alebo vonkaj\u0161ie upevnenie st\u013apika pomocou skrutiek<\/td><\/tr><tr><td>Tepeln\u00e1 trieda<\/td><td>Trieda B, 130 \u00b0C<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Environment\u00e1lne parametre<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>\u0160pecifik\u00e1cia<\/th><\/tr><\/thead><tbody><tr><td>V\u00fd\u0161ka in\u0161tal\u00e1cie<\/td><td>\u22642 000 m; dostupn\u00e9 verzie pre vysokohorsk\u00e9 prostredie<\/td><\/tr><tr><td>Prev\u00e1dzkov\u00e1 teplota<\/td><td>-30 \u00b0C a\u017e +70 \u00b0C<\/td><\/tr><tr><td>Teplota skladovania<\/td><td>-40 \u00b0C a\u017e +85 \u00b0C<\/td><\/tr><tr><td>Relat\u00edvna vlhkos\u0165<\/td><td>\u226495%, nekondenzuj\u00faca<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Platn\u00e9 normy<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\ud45c\uc900<\/th><th>Popis<\/th><\/tr><\/thead><tbody><tr><td>GB 1207<\/td><td>Nap\u00e4\u0165ov\u00e9 transform\u00e1tory<\/td><\/tr><tr><td>GB\/T 20840.1<\/td><td>Pr\u00edstrojov\u00e9 transform\u00e1tory \u2014 \u010cas\u0165 1: V\u0161eobecn\u00e9 po\u017eiadavky<\/td><\/tr><tr><td>GB\/T 20840.3<\/td><td>Pr\u00edstrojov\u00e9 transform\u00e1tory \u2013 \u010cas\u0165 3: Dodato\u010dn\u00e9 po\u017eiadavky na induk\u010dn\u00e9 nap\u00e4\u0165ov\u00e9 transform\u00e1tory<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Aplik\u00e1cie<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Platn\u00e9 nap\u00e4tia<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vhodn\u00e9 pre vn\u00fatorn\u00e9 a vonkaj\u0161ie nap\u00e1jacie syst\u00e9my 3 kV, 6 kV a 10 kV AC s maxim\u00e1lnym nap\u00e4t\u00edm syst\u00e9mu 12 kV.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Typick\u00e9 aplik\u00e1cie<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Meranie nap\u00e4tia, meranie energie a rel\u00e9ov\u00e1 ochrana vo vn\u00fatorn\u00fdch rozvodniach stredn\u00e9ho nap\u00e4tia a skri\u0148ov\u00fdch transform\u00e1torov\u00fdch staniciach<\/li>\n\n\n\n<li>Monitorovanie nap\u00e4tia a doh\u013ead nad izol\u00e1ciou vo vonkaj\u0161\u00edch energetick\u00fdch distribu\u010dn\u00fdch zariadeniach a syst\u00e9moch na st\u013apoch<\/li>\n\n\n\n<li>3 kV, 6 kV a 10 kV distribu\u010dn\u00e9 syst\u00e9my v priemyseln\u00fdch a bansk\u00fdch podnikoch<\/li>\n\n\n\n<li>Komercijalne zgrade i industrijski parkovi<\/li>\n\n\n\n<li>\u041d\u0430\u043f\u0440\u0435\u0436\u0435\u043d\u043e\u0432 \u043c\u043e\u043d\u0456\u0442\u043e\u0440\u0438\u043d\u0433, \u043a\u043e\u043d\u0442\u0440\u043e\u043b \u0438 \u043f\u0440\u0438\u0434\u043e\u0431\u0438\u0432\u0430\u043d\u0435 \u043d\u0430 \u0441\u0438\u0433\u043d\u0430\u043b \u0437\u0430 \u0437\u0430\u0449\u0438\u0442\u0430 \u0432 \u0441\u0438\u0441\u0442\u0435\u043c\u0438 \u0437\u0430 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f \u043d\u0430 \u0435\u043d\u0435\u0440\u0433\u043e\u043f\u043e\u0434\u0430\u0432\u0430\u043d\u0435\u0442\u043e<\/li>\n\n\n\n<li>Aplik\u00e1cie vn\u00fatorn\u00e9ho a vonkaj\u0161ieho rozvodu vy\u017eaduj\u00face bezolejov\u00fa izol\u00e1ciu a zv\u00fd\u0161en\u00fa odolnos\u0165 vo\u010di zne\u010disteniu a preskokom<\/li>\n\n\n\n<li>Vonkaj\u0161ie aplik\u00e1cie vystaven\u00e9 poveternostn\u00fdm vplyvom s modelom typu W<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Hlavn\u00e9 funkcie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nap\u00e4\u0165ov\u00fd transform\u00e1tor premie\u0148a vysok\u00e9 syst\u00e9mov\u00e9 nap\u00e4tie na \u0161tandardizovan\u00e9 sekund\u00e1rne nap\u00e4tie, zvy\u010dajne 100 V, v \u0161pecifikovanom pomere.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nap\u00e1ja nap\u00e4\u0165ov\u00e9 sign\u00e1ly na:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Energetick\u00e9 mera\u010de<\/li>\n\n\n\n<li>Meracie pr\u00edstroje<\/li>\n\n\n\n<li>Rel\u00e9ov\u00e9 ochrany<\/li>\n\n\n\n<li>Monitorovacie zariadenia<\/li>\n\n\n\n<li>Riadiace syst\u00e9my<\/li>\n\n\n\n<li>Zariadenia na monitorovanie izol\u00e1cie<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Transform\u00e1tor tie\u017e poskytuje elektrick\u00fa izol\u00e1ciu medzi prim\u00e1rnym a sekund\u00e1rnym syst\u00e9mom, \u010d\u00edm pom\u00e1ha chr\u00e1ni\u0165 pripojen\u00e9 zariadenia a obsluhu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ke\u010f je vybaven\u00fd pomocn\u00fdm sekund\u00e1rnym vinut\u00edm, m\u00f4\u017ee poskytn\u00fa\u0165 nap\u00e4\u0165ov\u00fd sign\u00e1l na monitorovanie izol\u00e1cie a detekciu zemn\u00e9ho spojenia v syst\u00e9me.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Prev\u00e1dzkov\u00e9 podmienky<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Norm\u00e1lne prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In\u0161tala\u010dn\u00e1 v\u00fd\u0161ka: maxim\u00e1lne 2 000 m<\/li>\n\n\n\n<li>Okolit\u00e1 teplota: -30 \u00b0C a\u017e +70 \u00b0C<\/li>\n\n\n\n<li>Vyhnite sa prudk\u00fdm alebo n\u00e1hlym zmen\u00e1m teploty.<\/li>\n\n\n\n<li>Relat\u00edvna vlhkos\u0165: maxim\u00e1lne 95 %, nekondenzuj\u00faca<\/li>\n\n\n\n<li>Prostredie by malo by\u0165 bez koroz\u00edvnych plynov<\/li>\n\n\n\n<li>Hor\u013eav\u00e9 alebo v\u00fdbu\u0161n\u00e9 l\u00e1tky nie s\u00fa povolen\u00e9<\/li>\n\n\n\n<li>Siln\u00e9 vibr\u00e1cie a mechanick\u00e9 n\u00e1razy by sa mali vyhn\u00fa\u0165<\/li>\n\n\n\n<li>Vn\u00fatorn\u00e9 modely musia by\u0165 chr\u00e1nen\u00e9 pred da\u017e\u010fom a kondenz\u00e1ciou.<\/li>\n\n\n\n<li>Vonkaj<\/li>\n\n\n\n<li>Vn\u00fatorn\u00e9 modely by mali by\u0165 chr\u00e1nen\u00e9 pred priamym slne\u010dn\u00fdm \u017eiaren\u00edm<\/li>\n\n\n\n<li>Vonkaj\u0161ie modely by mali by\u0165 in\u0161talovan\u00e9 na dobre vetranom mieste bez stojacej vody.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160peci\u00e1lne prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prisp\u00f4soben\u00e9 produkty s\u00fa potrebn\u00e9 pre:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nadmo\u0159sk\u00e9 v\u00fd\u0161ky instalace nad 2 000 m<\/li>\n\n\n\n<li>Teploty okolia mimo rozsah -30 \u00b0C a\u017e +70 \u00b0C<\/li>\n\n\n\n<li>\u0164a\u017ek\u00e9 zne\u010distenie alebo prostredie so slanou hmlou<\/li>\n\n\n\n<li>Chemicky korozivn\u00ed prost\u0159ed\u00ed<\/li>\n\n\n\n<li>Aplik\u00e1cie zah\u0155\u0148aj\u00face siln\u00e9 vibr\u00e1cie alebo mechanick\u00e9 n\u00e1razy<\/li>\n\n\n\n<li>Nestandardn\u00e9 prevodov\u00e9 pomery<\/li>\n\n\n\n<li>\u0160peci\u00e1lne triedy presnosti<\/li>\n\n\n\n<li>Nestandardn\u00e9 mont\u00e1\u017ene rozmery<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">In\u0161tal\u00e1cia a \u00fadr\u017eba<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na in\u0161tal\u00e1ciu<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Predin\u0161tala\u010dn\u00e1 kontrola:<\/strong><br>Skontrolujte nap\u00e4\u0165ov\u00fd transform\u00e1tor a overte, \u017ee teleso z liateho materi\u00e1lu neobsahuje praskliny, bubliny, mechanick\u00e9 po\u0161kodenia ani in\u00e9 vidite\u013en\u00e9 chyby. Skontrolujte, \u010di s\u00fa v\u0161etky ozna\u010denia svoriek jasn\u00e9 a \u010di s\u00fa dodan\u00e9 pr\u00edslu\u0161enstv\u00e1 kompletn\u00e9. Overte, \u017ee model, \u0161pecifik\u00e1cie, prevodov\u00fd pomer nap\u00e4tia a trieda presnosti zodpovedaj\u00fa po\u017eiadavk\u00e1m n\u00e1vrhu syst\u00e9mu. Pri vonkaj\u0161\u00edch modeloch typu W skontrolujte, \u010di s\u00fa \u0161trukt\u00fara odoln\u00e1 vo\u010di zne\u010disteniu a tesniace komponenty neporu\u0161en\u00e9.<\/li>\n\n\n\n<li><strong>Mont\u00e1\u017e:<\/strong><br>Nap\u00e4tie transform\u00e1tora umiestnite na ur\u010den\u00e9 miesto in\u0161tal\u00e1cie a pripevnite ho skrutkami cez mont\u00e1\u017ene otvory v z\u00e1kladni. Zaistite, aby bol transform\u00e1tor pevne nain\u0161talovan\u00fd bez uvo\u013enenia alebo posunutia. Mont\u00e1\u017eny povrch by mal by\u0165 rovn\u00fd, aby sa zabr\u00e1nilo nerovnomern\u00e9mu mechanick\u00e9mu nam\u00e1haniu. Vonkaj\u0161ie in\u0161tal\u00e1cie musia zah\u0155\u0148a\u0165 vhodn\u00e9 dren\u00e1\u017ene a vodotesn\u00e9 opatrenia.<\/li>\n\n\n\n<li><strong>Pripo<\/strong><br>Vysokonap\u00e4\u0165ov\u00fd termin\u00e1l pripojte pod\u013ea n\u00e1vrhu syst\u00e9mu. Zabezpe\u010dte, aby bolo pripojenie bezpe\u010dn\u00e9 a poskytovalo spo\u013eahliv\u00fd elektrick\u00fd kontakt. Udr\u017eujte dostato\u010dn\u00fa elektrick\u00fa vzdialenos\u0165 medzi vysokonap\u00e4\u0165ov\u00fdm vodi\u010dom, uzemnen\u00fdmi komponentmi a in\u00fdmi \u017eiv\u00fdmi \u010das\u0165ami. Vonkaj\u0161ie in\u0161tal\u00e1cie musia pou\u017e\u00edva\u0165 vhodn\u00e9 vodotesn\u00e9 izolovan\u00e9 vodi\u010de.<\/li>\n\n\n\n<li><strong>N\u00edzkonap\u00e4\u0165ov\u00e9 pripojenie:<\/strong><br>Sekund\u00e1rne svorky pripojte pod\u013ea ich ozna\u010denia. Meracie, ochrann\u00e9 a izola\u010dn\u00e9 monitorovacie obvody musia by\u0165 zapojen\u00e9 oddelene a spr\u00e1vne. Sekund\u00e1rny obvod nesmie by\u0165 po\u010das prev\u00e1dzky skratovan\u00fd. Jeden bod sekund\u00e1rneho obvodu mus\u00ed by\u0165 spo\u013eahlivo uzemnen\u00fd pod\u013ea n\u00e1vrhu syst\u00e9mu a platn\u00fdch po\u017eiadaviek na elektrick\u00fa bezpe\u010dnos\u0165.<\/li>\n\n\n\n<li><strong>Kontrola izol\u00e1cie:<\/strong><br>Po in\u0161tal\u00e1cii zmerajte izola\u010dn\u00fd odpor medzi:<ul><li>Vysok\u00e9 nap\u00e4tie a n\u00edzke nap\u00e4tie<\/li><li>Vysok\u00e9 nap\u00e4tie a zem<\/li><li>N\u00edzke nap\u00e4tie a zem<\/li><\/ul>Pred zapnut\u00edm transform\u00e1tora skontrolujte, \u010di je sekund\u00e1rne zapojenie spr\u00e1vne a bez ne\u00famyseln\u00fdch skratov alebo preru\u0161en\u00ed obvodu.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na \u00fadr\u017ebu<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pravidelne kontrolujte epoxidov\u00e9 teleso na praskliny, mechanick\u00e9 po\u0161kodenia, stopy po v\u00fdbojoch a zne\u010distenie.<\/li>\n\n\n\n<li>Skontrolujte vysokonap\u00e4\u0165ov\u00e9 svorky, \u010di nie s\u00fa uvo\u013enen\u00e9, skorodovan\u00e9 alebo abnorm\u00e1lne zahriate.<\/li>\n\n\n\n<li>Skontrolujte izola\u010dn\u00e9 pr\u00edstre\u0161ky, \u010di nie s\u00fa zanesen\u00e9 prachom alebo zne\u010disten\u00edm.<\/li>\n\n\n\n<li>Vonkaj\u0161ie modely typu W si osobitne v\u0161\u00edmajte z h\u013eadiska kon\u0161trukcie odolnej vo\u010di zne\u010disteniu, tesnenia svoriek a vodotesnosti.<\/li>\n\n\n\n<li>Pravidelne kontrolujte vysokonap\u00e4\u0165ov\u00e9 a n\u00edzkonap\u00e4\u0165ov\u00e9 zapojenie, aby ste sa uistili, \u017ee v\u0161etky spoje zost\u00e1vaj\u00fa pevn\u00e9 a bez prehriatia alebo zmeny farby.<\/li>\n\n\n\n<li>Potvr\u010fte, \u017ee uzemnenie sekund\u00e1rneho obvodu zost\u00e1va spo\u013eahliv\u00e9.<\/li>\n\n\n\n<li>Pravidelne testujte izola\u010dn\u00fd odpor a nap\u00e4\u0165ov\u00fd pomer, aby ste overili, \u010di presnos\u0165 merania a ochrany zost\u00e1va v stanoven\u00fdch medziach.<\/li>\n\n\n\n<li>Skontrolujte funkciu monitorovania izol\u00e1cie, kde je k dispoz\u00edcii pomocn\u00e9 vinutie.<\/li>\n\n\n\n<li>Vy\u010distite transform\u00e1tor od prachu a ne\u010dist\u00f4t.<\/li>\n\n\n\n<li>Pre vonkaj\u0161ie modely pravidelne \u010distite izola\u010dn\u00e9 pr\u00edstre\u0161ky, aby ste zn\u00ed\u017eili riziko zne\u010distenia a preskokov.<\/li>\n\n\n\n<li>Zabr\u00e1\u0148te kontaktu oleja a koroz\u00edvnych l\u00e1tok s epoxidov\u00fdm telesom.<\/li>\n\n\n\n<li>Ak sa zist\u00ed praskanie, vybitie, prehriatie alebo nadmern\u00e1 chyba prevodov\u00e9ho pomeru, okam\u017eite vypnite nap\u00e1janie a skontrolujte zariadenie. V pr\u00edpade potreby vyme\u0148te transform\u00e1tor.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Opatrenia<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Sekund\u00e1rne vinutie nesmie by\u0165 skratovan\u00e9, ke\u010f je transform\u00e1tor pod nap\u00e4t\u00edm. Skrat sekund\u00e1rneho vinutia m\u00f4\u017ee sp\u00f4sobi\u0165 nadmern\u00fd pr\u00fad a predstavova\u0165 v\u00e1\u017ene riziko pre zariadenie a person\u00e1l. Po\u010das \u00fadr\u017eby mus\u00ed by\u0165 transform\u00e1tor bez nap\u00e4tia a sekund\u00e1rny obvod mus\u00ed by\u0165 bezpe\u010dne izolovan\u00fd a uzemnen\u00fd v s\u00falade s platn\u00fdmi postupmi.<\/li>\n\n\n\n<li>Prepravou a in\u0161tal\u00e1ciou sa vyhnite n\u00e1razom alebo kol\u00edzi\u00e1m s telesom z epoxidovej \u017eivice, vysokonap\u00e4\u0165ov\u00fdmi svorkami a izola\u010dn\u00fdmi obj\u00edmkami. Mechanick\u00e9 po\u0161kodenie m\u00f4\u017ee zn\u00ed\u017ei\u0165 izola\u010dn\u00fd v\u00fdkon a odolnos\u0165 proti zne\u010disteniu a preskoku.<\/li>\n\n\n\n<li>Pou\u017eite vhodn\u00e9 izolovan\u00e9 vodi\u010de pre vysokonap\u00e4\u0165ov\u00e9 pripojenia. Udr\u017eujte dostato\u010dn\u00fa elektrick\u00fa vzdialenos\u0165 od uzemnen\u00fdch \u010dast\u00ed a in\u00fdch \u017eiv\u00fdch \u010dast\u00ed, aby ste zabr\u00e1nili v\u00fdboju medzi f\u00e1zami alebo medzi f\u00e1zou a zemou. Vonkaj\u0161ie pripojenia musia by\u0165 riadne utesnen\u00e9 proti vniknutiu vody.<\/li>\n\n\n\n<li>Zariadenie mus\u00ed by\u0165 spo\u013eahlivo uzemnen\u00e9. Uzem\u0148ovacia svorka na kovovej z\u00e1kladni mus\u00ed by\u0165 pevne pripojen\u00e1 k skrini rozv\u00e1dza\u010da alebo uzem\u0148ovacej zbernici.<\/li>\n\n\n\n<li>Produkt skladujte v suchom, vetranom a zatienenom prostred\u00ed. Vyhnite sa priamemu slne\u010dn\u00e9mu \u017eiareniu, vysok\u00fdm teplot\u00e1m, vlhkosti, stla\u010deniu a mechanick\u00fdm n\u00e1razom. Vonkaj\u0161ie modely typu W musia by\u0165 po\u010das skladovania tie\u017e chr\u00e1nen\u00e9 pred vlhkos\u0165ou a kor\u00f3ziou.<\/li>\n\n\n\n<li>In\u0161tal\u00e1ciu, uvedenie do prev\u00e1dzky a \u00fadr\u017ebu musia vykon\u00e1va\u0165 kvalifikovan\u00ed elektrik\u00e1ri v s\u00falade s platn\u00fdmi predpismi o bezpe\u010dnosti elektrick\u00fdch in\u0161tal\u00e1ci\u00ed.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160tandardn\u00fd zoznam dod\u00e1vok<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Nie.<\/th><th>Predmet<\/th><th>Funkcia<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>JDZJ-3, JDZJ-6, alebo JDZJ-10 (W) Nap\u00e4\u0165ov\u00fd transform\u00e1tor<\/td><td>Hlavn\u00e9 zariadenie na transform\u00e1ciu nap\u00e4tia, elektrick\u00fa izol\u00e1ciu a zber sign\u00e1lov<\/td><\/tr><tr><td>2<\/td><td>Mont\u00e1\u017ene skrutky a podlo\u017eky<\/td><td>Pou\u017e\u00edva sa na zaistenie nap\u00e4\u0165ov\u00e9ho transform\u00e1tora po\u010das in\u0161tal\u00e1cie<\/td><\/tr><tr><td>3<\/td><td>Krytka n\u00edzkonap\u00e4\u0165ovej svorky<\/td><td>Chr\u00e1ni sekund\u00e1rne svorky a pom\u00e1ha predch\u00e1dza\u0165 nespr\u00e1vnemu pripojeniu alebo skratom<\/td><\/tr><tr><td>4<\/td><td>N\u00e1vod na pou\u017eitie<\/td><td>Poskytuje pokyny na in\u0161tal\u00e1ciu, prev\u00e1dzku, \u00fadr\u017ebu a zapojenie<\/td><\/tr><tr><td>5<\/td><td>Certifik\u00e1t produktu a tov\u00e1rensk\u00e1 sk\u00fa\u0161obn\u00e1 spr\u00e1va<\/td><td>Poskytuje dokument\u00e1ciu o kvalite a v\u00fdkone produktu, vr\u00e1tane \u00fadajov z testov pomeru nap\u00e4tia a presnosti<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Platn\u00e9 normy a certifik\u00e1cia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobok sp\u013a\u0148a nasleduj\u00face normy:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GB 1207, <em>Nap\u00e4\u0165ov\u00e9 transform\u00e1tory<\/em><\/li>\n\n\n\n<li>GB\/T 20840.1 <em>Pr\u00edstrojov\u00e9 transform\u00e1tory \u2014 \u010cas\u0165 1: V\u0161eobecn\u00e9 po\u017eiadavky<\/em><\/li>\n\n\n\n<li>GB\/T 20840.3 <em>Pr\u00edstrojov\u00e9 transform\u00e1tory \u2013 \u010cas\u0165 3: Dodato\u010dn\u00e9 po\u017eiadavky na induk\u010dn\u00e9 nap\u00e4\u0165ov\u00e9 transform\u00e1tory<\/em><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobok \u00faspe\u0161ne absolvoval pr\u00edslu\u0161n\u00e9 typov\u00e9 sk\u00fa\u0161ky a jeho v\u00fdkon sp\u013a\u0148a prev\u00e1dzkov\u00e9 po\u017eiadavky vn\u00fatorn\u00fdch a vonkaj\u0161\u00edch energetick\u00fdch syst\u00e9mov 3 kV, 6 kV a 10 kV.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"976\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZJ-3-JDZJ-6-and-JDZJ-10-W-Voltage-Transformers\uff081\uff09-1024x976.webp\" alt=\"JDZJ-3, JDZJ-6 a JDZJ-10 (W) Meracie transform\u00e1tory nap\u00e4tia\" class=\"wp-image-2558\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZJ-3-JDZJ-6-and-JDZJ-10-W-Voltage-Transformers\uff081\uff09-1024x976.webp 1024w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZJ-3-JDZJ-6-and-JDZJ-10-W-Voltage-Transformers\uff081\uff09-300x286.webp 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZJ-3-JDZJ-6-and-JDZJ-10-W-Voltage-Transformers\uff081\uff09-768x732.webp 768w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZJ-3-JDZJ-6-and-JDZJ-10-W-Voltage-Transformers\uff081\uff09-13x12.webp 13w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JDZJ-3-JDZJ-6-and-JDZJ-10-W-Voltage-Transformers\uff081\uff09.webp 1044w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The JDZJ-3, JDZJ-6, and JDZJ-10 (W) Voltage Transformers are single-phase, semi-enclosed, dry-type voltage transformers designed for indoor and [&hellip;]<\/p>\n","protected":false},"featured_media":2557,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[30],"class_list":["post-1620","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-instrument-transformer-series"],"acf":{"products_imagines":[2557],"short_describe":"<p><span style=\"color: #334155; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif; font-size: 16px; white-space: pre-wrap;\">The JDZJ-3, JDZJ-6, and JDZJ-10 (W) Voltage Transformers are single-phase, semi-enclosed, dry-type voltage transformers designed for indoor and outdoor 3 kV, 6 kV, and 10 kV AC power systems with a maximum system voltage of 12 kV.<\/span><\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/1620","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/2557"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/2557"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=1620"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=1620"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}