{"id":1622,"date":"2026-05-08T00:00:00","date_gmt":"2026-05-08T00:00:00","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1622"},"modified":"2026-09-15T02:16:16","modified_gmt":"2026-09-15T02:16:16","slug":"jdzx-f-9-10-voltage-transformer","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/jdzx-f-9-10-voltage-transformer\/","title":{"rendered":"JDZX (F) 9-10 Nap\u00e4tieov\u00fd transform\u00e1tor"},"content":{"rendered":"<p class=\"wp-block-paragraph\">JDZX(F)9-10 Transform\u00e1tor nap\u00e4tia<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Preh\u013ead produktu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">JDZX(F) 9-10\u578b\u7535\u538b\u4e92\u611f\u5668<\/a> je plne uzatvoren\u00fd, zaliaty epoxidovou \u017eivicou, such\u00fd transform\u00e1tor nap\u00e4tia ur\u010den\u00fd pre vn\u00fatorn\u00e9 striedav\u00e9 silov\u00e9 syst\u00e9my 10 kV (Um=12 kV). Integruje vinutie pre zvodov\u00e9 nap\u00e4tie (variant F funguje aj ako vyb\u00edjac\u00ed tlmi\u010d) a vyzna\u010duje sa vynikaj\u00facimi izola\u010dn\u00fdmi vlastnos\u0165ami, silnou odolnos\u0165ou proti zne\u010disteniu a prep\u00f3lovaniu a spo\u013eahlivou prev\u00e1dzkou. Pou\u017e\u00edva sa predov\u0161etk\u00fdm vo vn\u00fatorn\u00fdch strednonap\u00e4\u0165ov\u00fdch syst\u00e9moch 10 kV <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear <\/a>pre nap\u00e4tie, meranie energie, ochranu rel\u00e9 a monitorovanie izol\u00e1cie. Typ F navy\u0161e poskytuje funkciu vyb\u00edjania kondenz\u00e1torov\u00fdch bat\u00e9ri\u00ed. Transform\u00e1tor sa \u0161iroko pou\u017e\u00edva v distribu\u010dn\u00fdch syst\u00e9moch 10kV, prefabrikovan\u00fdch rozvodniach, prstencov\u00fdch hlavn\u00fdch jednotk\u00e1ch a zariadeniach na kompenz\u00e1ciu jalov\u00e9ho v\u00fdkonu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">K\u013e\u00fa\u010dov\u00e9 vlastnosti produktu<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Izol\u00e1cia a elektrick\u00fd v\u00fdkon<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Plne uzatvoren\u00e1 epoxidov\u00e1 \u017eivicov\u00e1 izol\u00e1cia: Jednotka je integr\u00e1lne vytvoren\u00e1 v\u00e1kuov\u00fdm odlievan\u00edm epoxidovou \u017eivicou bez vn\u00fatorn\u00fdch dut\u00edn, \u010do poskytuje vynikaj\u00faci izola\u010dn\u00fd v\u00fdkon. Odol\u00e1va prev\u00e1dzkov\u00e9mu nap\u00e4tiu syst\u00e9mu 12 kV a prech\u00e1dza sk\u00fa\u0161kami odolnosti vo\u010di nap\u00e4tiu pri frekvencii v\u00fdkonu a impulzn\u00e9mu nap\u00e4tiu. \u00darove\u0148 \u010diasto\u010dn\u00fdch v\u00fdbojov je \u226410pC. Dlhodob\u00e1 prev\u00e1dzka je bez rizika starnutia izol\u00e1cie, \u00faniku a kontamin\u00e1cie olejom, \u010do ju rob\u00ed vhodnou pre bezolejov\u00e9 vn\u00fatorn\u00e9 distribu\u010dn\u00e9 aplik\u00e1cie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kon\u0161trukcia sekund\u00e1rneho vinutia zvodov\u00e9ho nap\u00e4tia: Integrovan\u00e9 sekund\u00e1rne vinutie zvodov\u00e9ho nap\u00e4tia poskytuje v\u00fdstup 100\/3 V na monitorovanie izol\u00e1cie pri zemn\u00fdch poruch\u00e1ch, kompatibiln\u00e9 s trojf\u00e1zov\u00fdmi, p\u00e4\u0165ramenn\u00fdmi kon\u0161trukciami transform\u00e1torov nap\u00e4tia, aby sp\u013a\u0148alo po\u017eiadavky na monitorovanie izol\u00e1cie neefekt\u00edvne uzemnen\u00fdch neutr\u00e1lnych syst\u00e9mov.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0160irok\u00e1 kompatibilita nap\u00e4\u0165ov\u00fdch pomerov: Podporuje \u0161tandardn\u00e9 nap\u00e4\u0165ov\u00e9 pomery (napr. 10\/0,1\/0,1\/3 kV). Presnos\u0165 merania m\u00f4\u017ee dosiahnu\u0165 triedu 0,2; trieda ochrany m\u00f4\u017ee by\u0165 prisp\u00f4soben\u00e1 na 3P\/6P, \u010d\u00edm sp\u013a\u0148a po\u017eiadavky aplik\u00e1ci\u00ed merania, ochrany a monitorovania izol\u00e1cie. Typ F s\u00fa\u010dasne sp\u013a\u0148a po\u017eiadavky na elektrick\u00e9 parametre vyb\u00edjac\u00edch cievok kondenz\u00e1torov\u00fdch bat\u00e9ri\u00ed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vysok\u00e1 odolnos\u0165 proti zne\u010disteniu a preskokom: Vysokonap\u00e4\u0165ov\u00e1 strana vyu\u017e\u00edva integrovan\u00fa izol\u00e1ciu typu rebrovania s ve\u013ekou \u00fanikovou vzdialenos\u0165ou, \u010do poskytuje vynikaj\u00facu odolnos\u0165 proti preskokom v zne\u010distenom prostred\u00ed a zni\u017euje riziko povrchov\u00e9ho sledovania.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kon\u0161truk\u010dn\u00e9 a in\u0161tala\u010dn\u00e9 vlastnosti<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Plne uzatvoren\u00e1 such\u00e1 kon\u0161trukcia: Integrovan\u00e1 liata kon\u0161trukcia nem\u00e1 \u017eiadne odkryt\u00e9 \u010dasti pod nap\u00e4t\u00edm s kryt\u00edm IP20. Bezolejov\u00e9 vyhotovenie eliminuje riziko po\u017eiaru. Kompaktn\u00fd, n\u00edzky profil je kompatibiln\u00fd so \u0161tandardn\u00fdmi rozmermi in\u0161tal\u00e1cie rozv\u00e1dza\u010dov.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Viac\u00fa\u010delov\u00fd integrovan\u00fd dizajn: Typ F integruje funkcie transform\u00e1tora nap\u00e4tia a vyb\u00edjacieho vinutia, \u010d\u00edm s\u00fa\u010dasne umo\u017e\u0148uje monitorovanie nap\u00e4tia a rozpt\u00fdlenie zvy\u0161kov\u00e9ho n\u00e1boja z bat\u00e9riov\u00fdch b\u00e1nk. T\u00fdm sa zjednodu\u0161uje konfigur\u00e1cia zariaden\u00ed v skrini, zmen\u0161uje priestor na in\u0161tal\u00e1ciu a zni\u017euj\u00fa celkov\u00e9 n\u00e1klady.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Preh\u013eadn\u00e9 usporiadanie svoriek: Sekund\u00e1rne svorky s\u00fa chr\u00e1nen\u00e9 prieh\u013eadn\u00fdmi krytmi s jasn\u00fdm ozna\u010den\u00edm, \u010do u\u013eah\u010duje zapojenie a zabra\u0148uje nespr\u00e1vnemu pripojeniu a skratom. Usporiadanie svoriek zodpoved\u00e1 \u0161tandardom pre zapojenie sekund\u00e1rnych obvodov v skrini.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Flexibiln\u00e9 upevnenie: Z\u00e1kladn\u00e1 kovov\u00e1 mont\u00e1\u017ena doska je vybaven\u00e1 upev\u0148ovac\u00edmi otvormi pre skrutkov\u00fa in\u0161tal\u00e1ciu, podporuje horizont\u00e1lnu vn\u00fatorn\u00fa mont\u00e1\u017e v skrini. Zostava je mechanicky pevn\u00e1 s vynikaj\u00facou odolnos\u0165ou proti vibr\u00e1ci\u00e1m, \u010do umo\u017e\u0148uje kompaktn\u00e9 usporiadanie v skrini.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Prev\u00e1dzkov\u00e9 a \u00fadr\u017ebov\u00e9 funkcie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bez\u00fadr\u017ebov\u00e1 prev\u00e1dzka: Such\u00e1, bezolejov\u00e1 kon\u0161trukcia eliminuje riziko \u00faniku a po\u017eiaru. Vysok\u00e1 mechanick\u00e1 pevnos\u0165 epoxidov\u00e9ho odliatku poskytuje odolnos\u0165 proti n\u00e1razom a starnutiu pre dlhodob\u00fa bez\u00fadr\u017ebov\u00fa prev\u00e1dzku, \u010d\u00edm sa zni\u017euj\u00fa prev\u00e1dzkov\u00e9 n\u00e1klady. Typ F eliminuje potrebu samostatnej vyb\u00edjacie cievky, \u010d\u00edm sa zni\u017euj\u00fa body \u00fadr\u017eby.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0160irok\u00fd rozsah prev\u00e1dzkov\u00fdch tepl\u00f4t: Navrhnut\u00e9 pre okolit\u00e9 teploty od -30\u00b0C do +70\u00b0C. Vlastnosti epoxidovej \u017eivice zost\u00e1vaj\u00fa stabiln\u00e9 v celom rozsahu tepl\u00f4t bez rizika krehnutia alebo deform\u00e1cie, vhodn\u00e9 pre r\u00f4zne region\u00e1lne klimatick\u00e9 podmienky.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vysok\u00e1 spo\u013eahlivos\u0165 kon\u0161trukcie: \u017delezn\u00e9 jadro je vyroben\u00e9 z vysoko kvalitn\u00fdch plechov z krem\u00edkovej ocele a vinutia s\u00fa navinut\u00e9 z meden\u00e9ho dr\u00f4tu s izol\u00e1ciou. N\u00edzke prev\u00e1dzkov\u00e9 straty a minim\u00e1lne generovanie tepla zais\u0165uj\u00fa, \u017ee jednotka odol\u00e1va prep\u00e4tiu pri sp\u00ednan\u00ed syst\u00e9mu a prep\u00e4tiu pri atmosf\u00e9rickom v\u00fdboji, \u010d\u00edm zaru\u010duje spo\u013eahliv\u00e9 meracie, ochrann\u00e9 a monitorovacie sign\u00e1ly izol\u00e1cie.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Technick\u00e9 parametre (typick\u00e9 \u0161pecifik\u00e1cie)<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Aplik\u00e1cie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pou\u017eite\u013en\u00e1 trieda nap\u00e4tia: 10kV (Um=12kV) vn\u00fatorn\u00e9 striedav\u00e9 silnopr\u00fadov\u00e9 syst\u00e9my.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Typick\u00e9 scen\u00e1re pou\u017eitia:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Meranie nap\u00e4tia, meranie energie a rel\u00e9ov\u00e1 ochrana v indoorov\u00fdch rozvodn\u00fdch zariadeniach stredn\u00e9ho nap\u00e4tia a prefabrikovan\u00fdch transformovniach;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10kV distribu\u010dn\u00e9 syst\u00e9my v distribu\u010dn\u00fdch transformovniach, priemyseln\u00fdch a bansk\u00fdch podnikoch, komer\u010dn\u00fdch budov\u00e1ch a priemyseln\u00fdch parkoch;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Z\u00edskavanie sign\u00e1lov na monitorovanie, riadenie a ochranu nap\u00e4tia v syst\u00e9moch automatiz\u00e1cie energetiky;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Monitorovanie izol\u00e1cie v neefekt\u00edvne uzemnen\u00fdch neutr\u00e1lnych syst\u00e9moch, kompatibiln\u00e9 s trojf\u00e1zov\u00fdmi p\u00e4\u0165ramenn\u00fdmi konfigur\u00e1ciami zapojenia;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F-typ pre zariadenia na kompenz\u00e1ciu jalov\u00e9ho v\u00fdkonu na s\u00fa\u010dasn\u00e9 monitorovanie nap\u00e4tia a vyb\u00edjanie kondenz\u00e1torov\u00fdch bat\u00e9ri\u00ed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Funk\u010dn\u00fd \u00fa\u010del: Zni\u017euje vysok\u00e9 syst\u00e9mov\u00e9 nap\u00e4tie na \u0161tandardn\u00e9 n\u00edzke nap\u00e4tie (100 V) na nap\u00e1janie merac\u00edch pr\u00edstrojov, ochrann\u00fdch zariaden\u00ed a riadiacich syst\u00e9mov, pri\u010dom zabezpe\u010duje elektrick\u00fa izol\u00e1ciu medzi prim\u00e1rnym a sekund\u00e1rnym syst\u00e9mom. Vinutie zvy\u0161kovej nap\u00e4tia monitoruje zemn\u00e9 poruchy syst\u00e9mu na \u00fa\u010dely doh\u013eadu nad izol\u00e1ciou. Typ F navy\u0161e rozpty\u013euje zvy\u0161kov\u00fd n\u00e1boj z kondenz\u00e1torov\u00fdch b\u00e1nk na zaistenie bezpe\u010dnosti pri \u00fadr\u017ebe.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Norm\u00e1lne prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fd\u0161ka: \u22642000 m<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okolit\u00e1 teplota: -30 \u00b0C a\u017e +70 \u00b0C, bez prudk\u00fdch teplotn\u00fdch v\u00fdkyvov;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Relat\u00edvna vlhkos\u0165: \u226495 % (nekondenzuj\u00faca)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podmienky prostredia: Bez koroz\u00edvnych plynov, hor\u013eav\u00fdch alebo v\u00fdbu\u0161n\u00fdch m\u00e9di\u00ed, siln\u00fdch vibr\u00e1ci\u00ed a otrasov, ako aj zna\u010dn\u00e9ho prachu alebo so\u013enej hmly;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In\u0161tal\u00e1cia: Vn\u00fatorn\u00e1 mont\u00e1\u017e na st\u013ap, chr\u00e1nen\u00e1 pred priamym slne\u010dn\u00fdm \u017eiaren\u00edm, da\u017e\u010fom a kondenz\u00e1ciou.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160peci\u00e1lne prev\u00e1dzkov\u00e9 podmienky (vy\u017eaduje sa prisp\u00f4sobenie)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nadmorsk\u00e1 v\u00fd\u0161ka presahuj\u00faca 2000 m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okolit\u00e1 teplota mimo rozsah -30 \u00b0C a\u017e +70 \u00b0C;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Silne zanieczyszczone, mg\u0142a solna lub \u015brodowiska korozyjne chemicznie;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prev\u00e1dzkov\u00e9 podmienky s vysok\u00fdmi vibr\u00e1ciami alebo vysok\u00fdmi otrasmi;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nestandardn\u00e9 prevodov\u00e9 pomery, triedy presnosti alebo mont\u00e1\u017ene rozmery.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">In\u0161tal\u00e1cia a \u00fadr\u017eba<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na in\u0161tal\u00e1ciu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u041f\u0440\u0435\u0434\u043c\u043e\u043d\u0442\u0430\u0436\u043d\u0430 \u043f\u0435\u0440\u0435\u0432\u0456\u0440\u043a\u0430: \u041e\u0433\u043b\u044f\u043d\u044c\u0442\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440 \u043d\u0430\u043f\u0440\u0443\u0433\u0438 \u043d\u0430 \u043d\u0430\u044f\u0432\u043d\u0456\u0441\u0442\u044c \u0437\u043e\u0432\u043d\u0456\u0448\u043d\u0456\u0445 \u0434\u0435\u0444\u0435\u043a\u0442\u0456\u0432 \u2014 \u043b\u0438\u0442\u0438\u0439 \u043a\u043e\u0440\u043f\u0443\u0441 \u043f\u043e\u0432\u0438\u043d\u0435\u043d \u0431\u0443\u0442\u0438 \u0431\u0435\u0437 \u0442\u0440\u0456\u0449\u0438\u043d, \u043f\u043e\u0440\u043e\u0436\u043d\u0438\u043d \u0456 \u043f\u043e\u0448\u043a\u043e\u0434\u0436\u0435\u043d\u044c; \u043a\u043b\u0435\u043c\u0438 \u043f\u043e\u0432\u0438\u043d\u043d\u0456 \u0431\u0443\u0442\u0438 \u0447\u0456\u0442\u043a\u043e \u043c\u0430\u0440\u043a\u043e\u0432\u0430\u043d\u0456, \u0430 \u0432\u0441\u0456 \u0430\u043a\u0441\u0435\u0441\u0443\u0430\u0440\u0438 \u043f\u0440\u0438\u0441\u0443\u0442\u043d\u0456. \u041f\u0435\u0440\u0435\u043a\u043e\u043d\u0430\u0439\u0442\u0435\u0441\u044f, \u0449\u043e \u043c\u043e\u0434\u0435\u043b\u044c, \u043d\u043e\u043c\u0456\u043d\u0430\u043b\u044c\u043d\u0456 \u0434\u0430\u043d\u0456, \u043a\u043e\u0435\u0444\u0456\u0446\u0456\u0454\u043d\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0446\u0456\u0457 \u0442\u0430 \u043a\u043b\u0430\u0441 \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u0456 \u0432\u0456\u0434\u043f\u043e\u0432\u0456\u0434\u0430\u044e\u0442\u044c \u043f\u0440\u043e\u0435\u043a\u0442\u043d\u0438\u043c \u0432\u0438\u043c\u043e\u0433\u0430\u043c. \u0414\u043b\u044f \u0430\u0433\u0440\u0435\u0433\u0430\u0442\u0456\u0432 \u0442\u0438\u043f\u0443 F \u043f\u0435\u0440\u0435\u0432\u0456\u0440\u0442\u0435, \u0447\u0438 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u0438 \u0444\u0443\u043d\u043a\u0446\u0456\u0457 \u0440\u043e\u0437\u0440\u044f\u0434\u0443 \u0432\u0456\u0434\u043f\u043e\u0432\u0456\u0434\u0430\u044e\u0442\u044c \u0432\u0438\u043c\u043e\u0433\u0430\u043c \u043f\u0440\u0438\u0441\u0442\u0440\u043e\u044e \u043a\u043e\u043c\u043f\u0435\u043d\u0441\u0430\u0446\u0456\u0457 \u0440\u0435\u0430\u043a\u0442\u0438\u0432\u043d\u043e\u0457 \u043f\u043e\u0442\u0443\u0436\u043d\u043e\u0441\u0442\u0456.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mont\u00e1\u017e a upevnenie: Umiestnite nap\u00e4\u0165ov\u00fd transform\u00e1tor na ur\u010den\u00e9 miesto v rozv\u00e1dza\u010di a pripevnite ho cez mont\u00e1\u017ene otvory na z\u00e1kladni pomocou skrutiek, \u010d\u00edm zaist\u00edte pevn\u00e9 upevnenie bez uvo\u013enenia alebo nes\u00faososti. Mont\u00e1\u017eny povrch mus\u00ed by\u0165 rovn\u00fd, aby sa zabr\u00e1nilo excentrick\u00e9mu za\u0165a\u017eeniu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zapojenie na strane vysok\u00e9ho nap\u00e4tia: Pripojte vysokonap\u00e4\u0165ov\u00e9 svorky pod\u013ea po\u017eiadaviek n\u00e1vrhu, pri\u010dom zabezpe\u010dte pevn\u00e9 spoje a dobr\u00fd kontakt. Dodr\u017eiavajte dostato\u010dn\u00e9 bezpe\u010dnostn\u00e9 vzdialenosti medzi vysokonap\u00e4\u0165ov\u00fdmi vodi\u010dmi, uzemnen\u00fdmi \u010das\u0165ami a in\u00fdmi \u017eiv\u00fdmi \u010das\u0165ami, aby ste zabr\u00e1nili v\u00fdboju. Jednotky typu F musia by\u0165 zapojen\u00e9 v s\u00falade s po\u017eiadavkami na zapojenie vyb\u00edjac\u00edch cievok.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00edzkonap\u00e4\u0165ov\u00e9 zapojenie: N\u00edzkonap\u00e4\u0165ov\u00e9 svorky pripojte pod\u013ea ozna\u010denia, s oddelen\u00fdm zapojen\u00edm pre meracie, ochrann\u00e9 a zvy\u0161ko-nap\u00e4\u0165ov\u00e9 obvody. Overte spr\u00e1vnos\u0165 zapojenia. Sekund\u00e1rne obvody sa nesm\u00fa nikdy skratova\u0165 a musia by\u0165 spo\u013eahlivo uzemnen\u00e9 (jednobodov\u00e9 uzemnenie) na zabr\u00e1nenie prep\u00e4tiu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Overenie izol\u00e1cie: Po in\u0161tal\u00e1cii zmerajte izola\u010dn\u00fd odpor (HV vo\u010di LV a zemi; LV vo\u010di zemi), aby ste potvrdili s\u00falad s po\u017eiadavkami na izol\u00e1ciu. Overte, \u017ee zapojenie sekund\u00e1rneho obvodu je spr\u00e1vne, bez skratov alebo preru\u0161en\u00ed. Pri jednotk\u00e1ch typu F overte, \u017ee vyb\u00edjac\u00ed obvod funguje spr\u00e1vne.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pokyny na \u00fadr\u017ebu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pravidelne kontrolujte vonkaj\u0161\u00ed stav nap\u00e4\u0165ov\u00e9ho transform\u00e1tora: liate teleso mus\u00ed by\u0165 bez praskl\u00edn, po\u0161koden\u00ed a st\u00f4p po v\u00fdboji; vysokonap\u00e4\u0165ov\u00e9 svorky nesm\u00fa vykazova\u0165 \u017eiadne uvo\u013enenie ani oxid\u00e1ciu; ochrann\u00e9 kryty sekund\u00e1rnych svoriek musia by\u0165 neporu\u0161en\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pravidelne kontrolujte pevnos\u0165 vysokonap\u00e4\u0165ov\u00fdch a n\u00edzkonap\u00e4\u0165ov\u00fdch spojov bez zn\u00e1mok prehriatia alebo zmeny farby; overte, \u017ee uzemnenie n\u00edzkonap\u00e4\u0165ov\u00e9ho obvodu je spo\u013eahliv\u00e9 bez rizika skratu alebo preru\u0161enia obvodu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pravidelne testujte izola\u010dn\u00fd odpor a nap\u00e4\u0165ov\u00fd pomer, aby ste potvrdili, \u017ee presnos\u0165 merania a ochrany sp\u013a\u0148a po\u017eiadavky; tie\u017e overte spr\u00e1vnu funkciu obvodu zvy\u0161kovej nap\u00e4tia a funkcie monitorovania izol\u00e1cie. Pre jednotky typu F pravidelne testujte parametre vyb\u00edjacieho funkcie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vy\u010distite transform\u00e1tor od prachu a ne\u010dist\u00f4t; zabr\u00e1\u0148te pri\u013enutiu oleja a koroz\u00edvnych l\u00e1tok; udr\u017eujte zariadenie such\u00e9 a \u010dist\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ak sa zistia praskliny, v\u00fdboj, prehriatie, odch\u00fdlka nap\u00e4\u0165ov\u00e9ho pomeru alebo funk\u010dn\u00e1 porucha, okam\u017eite odpojte nap\u00e1janie na kontrolu a v pr\u00edpade potreby vyme\u0148te zariadenie. Prev\u00e1dzka so zn\u00e1mymi chybami je pr\u00edsne zak\u00e1zan\u00e1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Bezpe\u010dnostn\u00e9 opatrenia<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sekund\u00e1rne vinutia sa nesm\u00fa nikdy skratova\u0165. Skrat v sekund\u00e1rnom obvode po\u010das prev\u00e1dzky sp\u00f4sob\u00ed nadmern\u00fd pr\u00fad a ohroz\u00ed zariadenie aj person\u00e1l. Po\u010das \u00fadr\u017eby mus\u00ed by\u0165 sekund\u00e1rny obvod spo\u013eahlivo preru\u0161en\u00fd a uzemnen\u00fd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pri in\u0161tal\u00e1cii sa vyh\u00fdbajte mechanick\u00fdm n\u00e1razom alebo kol\u00edzi\u00e1m s liatym telesom, aby ste zabr\u00e1nili prasknutiu epoxidovej \u017eivice a po\u0161kodeniu izol\u00e1cie, \u010do by zhor\u0161ilo izola\u010dn\u00fd v\u00fdkon a schopnos\u0165 odol\u00e1va\u0165 zne\u010disteniu a preskokom.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vysokonap\u00e4\u0165ov\u00e9 vedenie mus\u00ed pou\u017e\u00edva\u0165 \u0161pecializovan\u00e9 izolovan\u00e9 vodi\u010de, pri\u010dom sa mus\u00ed dodr\u017ea\u0165 dostato\u010dn\u00e1 bezpe\u010dnostn\u00e1 vzdialenos\u0165 od uzemnen\u00fdch \u010dast\u00ed a in\u00fdch \u010dast\u00ed pod nap\u00e4t\u00edm, aby sa zabr\u00e1nilo v\u00fdboju medzi f\u00e1zami alebo medzi f\u00e1zou a zemou. Vedenie jednotky typu F mus\u00ed s\u00fa\u010dasne sp\u013a\u0148a\u0165 po\u017eiadavky na zapojenie nap\u00e4\u0165ov\u00e9ho transform\u00e1tora aj vyb\u00edjacie cievky.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Uzemnenie zariadenia mus\u00ed by\u0165 spo\u013eahliv\u00e9; z\u00e1kladn\u00fd uzem\u0148ovac\u00ed termin\u00e1l mus\u00ed by\u0165 pevne pripojen\u00fd k uzem\u0148ovacej zbernici skrinky.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pri skladovan\u00ed uchov\u00e1vajte jednotku v suchom, vetranom, chladnom prostred\u00ed, chr\u00e1nenom pred priamym slne\u010dn\u00fdm \u017eiaren\u00edm, vysok\u00fdmi teplotami, vlhkos\u0165ou a mechanick\u00fdm stla\u010den\u00edm, aby ste zabr\u00e1nili starnutiu alebo deform\u00e1cii liateho telesa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In\u0161tal\u00e1ciu, uvedenie do prev\u00e1dzky a \u00fadr\u017ebu musia vykon\u00e1va\u0165 kvalifikovan\u00ed elektrik\u00e1ri v pr\u00edsnom s\u00falade s prev\u00e1dzkov\u00fdmi postupmi elektrickej bezpe\u010dnosti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160tandardn\u00fd rozsah dod\u00e1vky<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Kateg\u00f3ria parametra<\/td><td>Predmet<\/td><td>Technick\u00e1 \u0161pecifik\u00e1cia<\/td><\/tr><tr><td>Elektrick\u00e9 parametre<\/td><td>Syst\u00e9mov\u00e9 nap\u00e4tie<\/td><td>10kV AC (Um=12kV)<\/td><\/tr><tr><td><\/td><td>| Menovit\u00e9 frekvencie<\/td><td>50\u8d6b\u5179<\/td><\/tr><tr><td><\/td><td>| Menovit\u00e1 prim\u00e1rna nap\u00e4tie<\/td><td>10kV<\/td><\/tr><tr><td><\/td><td>| Menovit\u00e1 sekund\u00e1rna nap\u00e4tie<\/td><td>100V (meranie\/ochrana), 100\/3V (zvy\u0161kov\u00e9 nap\u00e4tie\/monitorovanie izol\u00e1cie)<\/td><\/tr><tr><td><\/td><td>| Triediaca trieda presnosti<\/td><td>0.2 \/ 0.5 \/ 1<\/td><\/tr><tr><td><\/td><td>| Triednos\u0165 ochrany<\/td><td>3P \/ 6P<\/td><\/tr><tr><td><\/td><td>| V\u00fdkonov\u00e9 frekven\u010dn\u00e9 v\u00fddr\u017en\u00e9 nap\u00e4tie (HV svorka)<\/td><td>42kV \/ 1min, bez preru\u0161enia<\/td><\/tr><tr><td><\/td><td>| Impulzn\u00e1 odolnos\u0165 vo\u010di prep\u00e4tiu (\u0161pi\u010dkov\u00e1)<\/td><td>75kV, bez prierazov<\/td><\/tr><tr><td><\/td><td>\u00darove\u0148 \u010diasto\u010dn\u00e9ho v\u00fdboja<\/td><td>\u226410pC<\/td><\/tr><tr><td><\/td><td>| Izola\u010dn\u00fd odpor (VN na NN a zem)<\/td><td>\u22651000M\u03a9<\/td><\/tr><tr><td>Kon\u0161truk\u010dn\u00e9 a materi\u00e1lov\u00e9 parametre<\/td><td>Izola\u010dn\u00fd materi\u00e1l<\/td><td>Pln\u00e1 epoxidov\u00e1 \u017eivica<\/td><\/tr><tr><td><\/td><td>| Hodnotenie ochrany<\/td><td>IP20<\/td><\/tr><tr><td><\/td><td>| Sp\u00f4sob mont\u00e1\u017ee<\/td><td>Vn\u00fatorn\u00e1 st\u013apikov\u00e1 skrutkovan\u00e1 in\u0161tal\u00e1cia<\/td><\/tr><tr><td><\/td><td>| Tepeln\u00e1 trieda izol\u00e1cie<\/td><td>Trieda B (130 \u00b0C)<\/td><\/tr><tr><td>Environment\u00e1lne parametre<\/td><td>Prev\u00fd\u0161enie pri prev\u00e1dzke<\/td><td>\u22642000 m (dostupn\u00e9 prisp\u00f4sobenie pre vysok\u00fa nadmorsk\u00fa v\u00fd\u0161ku)<\/td><\/tr><tr><td><\/td><td>| Prev\u00e1dzkov\u00e1 teplota okolia<\/td><td>-30 \u00b0C a\u017e +70 \u00b0C<\/td><\/tr><tr><td><\/td><td>| Teplota skladovania<\/td><td>-40 \u00b0C a\u017e +85 \u00b0C<\/td><\/tr><tr><td><\/td><td>Relat\u00edvna vlhkos\u0165<\/td><td>\u226495% (nekondenzuj\u00faca)<\/td><\/tr><tr><td>Platn\u00e9 normy<\/td><td>N\u00e1rodn\u00e9 \u0161tandardy<\/td><td>GB 1207 \u7535\u538b\u4e92\u611f\u5668\uff1bGB\/T 20840 \u7cfb\u5217\uff1bDL\/T 653 \u5206\u8def\u7535\u5bb9\u5668\u7528\u7535\u6297\u5668\uff08F\u578b\uff09\u8ba2\u8d27\u6280\u672f\u6761\u4ef6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160tandardy a certifik\u00e1cie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u4ea7\u54c1\u7b26\u5408GB 1207\u7535\u538b\u4e92\u611f\u5668\u3001GB\/T 20840.1\u4e92\u611f\u5668 \u7b2c1\u90e8\u5206\uff1a\u603b\u5219\u3001GB\/T 20840.3\u4e92\u611f\u5668 \u7b2c3\u90e8\u5206\uff1a\u611f\u5e94\u5f0f\u7535\u538b\u4e92\u611f\u5668\u8865\u5145\u89c4\u5b9a\u7b49\u9002\u7528\u7684\u56fd\u5bb6\u6807\u51c6\u3002F\u578b\u4ea7\u54c1\u8fd8\u7b26\u5408\u4e32\u8054\u7535\u6297\u5668\u8ba2\u8d27\u6280\u672f\u6761\u4ef6DL\/T 653\u7684\u89c4\u5b9a\u3002\u4ea7\u54c1\u5df2\u901a\u8fc7\u578b\u5f0f\u8bd5\u9a8c\uff0c\u6ee1\u8db310kV\u6237\u5185\u7535\u529b\u7cfb\u7edf\u8fd0\u884c\u8981\u6c42\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pr\u00edloha: N\u00e1kres obrysu produktu<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160tandardn\u00e1 konfigur\u00e1cia<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Nie.<\/th><th>Meno<\/th><th>\u00da\u010del<\/th><\/tr><tr><td>1<\/td><td>JDZX (F) 9-10 Nap\u00e4tieov\u00fd transform\u00e1tor<\/td><td>Jadro jednotky, poskytuj\u00face transform\u00e1ciu nap\u00e4tia \/ izol\u00e1ciu \/ izol\u00e1ciu (vybitie F<\/td><\/tr><tr><td>2<\/td><td>Mont\u00e1\u017ene skrutky \/ podlo\u017eky<\/td><td>Transform\u00e1tor nap\u00e4tiaPevn\u00e1 in\u0161tal\u00e1cia<\/td><\/tr><tr><td>3<\/td><td>Sekund\u00e1rny termin\u00e1l prieh\u013eadn\u00fd ochrann\u00fd kryt<\/td><td>Ochrann\u00e1 svorka, zabr\u00e1nenie nespr\u00e1vnemu pripojeniu \/ skratu<\/td><\/tr><tr><td>4<\/td><td>Pou\u017e\u00edvate\u013esk\u00e1 pr\u00edru\u010dka<\/td><td>Pr\u00edru\u010dka in\u0161tal\u00e1cie \/ prev\u00e1dzky a \u00fadr\u017eby, F V\u00fdpust<\/td><\/tr><tr><td>5<\/td><td>Certifik\u00e1t produktu a tov\u00e1rensk\u00e1 sk\u00fa\u0161obn\u00e1 spr\u00e1va<\/td><td>Dokument\u00e1cia certifik\u00e1cie kvality v\u00fdkonu, \u00fadaje z testu pomeru nap\u00e4tia \/ chyby \/ vybitia (F)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Inform\u00e1cie o objedn\u00e1vke<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pred objedn\u00e1vkou si overte pr\u00edslu\u0161n\u00e9 syst\u00e9mov\u00e9 nap\u00e4tie, triedu presnosti merania, triedu presnosti ochrany, sp\u00f4sob mont\u00e1\u017ee, stupe\u0148 ochrany a po\u017eadovan\u00e9 mno\u017estvo pod\u013ea projektov\u00fdch v\u00fdkresov a \u0161pecifik\u00e1cie zdroja.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"513\" height=\"671\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/07\/yieou-source-1622-62181e90cb86a899-02-5ad4997499.png\" alt=\"JDZX(F)9-10 zdrojov\u00fd obr\u00e1zok 2\" class=\"wp-image-2350\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/07\/yieou-source-1622-62181e90cb86a899-02-5ad4997499.png 513w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/07\/yieou-source-1622-62181e90cb86a899-02-5ad4997499-229x300.png 229w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/07\/yieou-source-1622-62181e90cb86a899-02-5ad4997499-9x12.png 9w\" sizes=\"(max-width: 513px) 100vw, 513px\" \/><figcaption class=\"wp-element-caption\">JDZX (F) 9-10 Nap\u00e4tieov\u00fd transform\u00e1tor<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>JDZX(F)9-10 Voltage Transformer Product Overview The JDZX (F) 9-10 voltage transformer is a fully-enclosed, epoxy-resin cast dry-type voltage transformer designed [&hellip;]<\/p>\n","protected":false},"featured_media":2511,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[30],"class_list":["post-1622","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-instrument-transformer-series"],"acf":{"products_imagines":[2511],"short_describe":"<p>The JDZX(F)9-10 voltage transformer is a fully-enclosed, epoxy-resin cast dry-type voltage transformer designed for 10kV (Um=12kV) indoor AC power systems.&nbsp;<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/1622","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/2511"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/2511"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=1622"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=1622"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}