{"id":1626,"date":"2026-05-08T00:00:00","date_gmt":"2026-05-08T00:00:00","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=1626"},"modified":"2026-09-15T02:42:12","modified_gmt":"2026-09-15T02:42:12","slug":"jlszvw-10-combined-metering-transformer","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/jlszvw-10-combined-metering-transformer\/","title":{"rendered":"JLSZVW-10 Kombinovan\u00fd merac\u00ed transform\u00e1tor"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Preh\u013ead produktu<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">Kombinovan\u00fd merac\u00ed transform\u00e1tor JLSZVW-10<\/a> je vonkaj\u0161ia epoxidov\u00e1 odlievan\u00e1 jednotka na meranie energie navrhnut\u00e1 pre trojf\u00e1zov\u00e9 trojvodi\u010dov\u00e9 striedav\u00e9 nap\u00e1jacie syst\u00e9my 10 kV s maxim\u00e1lnym nap\u00e4t\u00edm syst\u00e9mu 12 kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Na z\u00e1klade dvojprvkov\u00e9ho meracieho usporiadania jednotka integruje funkcie nap\u00e4\u0165ov\u00e9ho a pr\u00fadov\u00e9ho transform\u00e1tora, \u010do umo\u017e\u0148uje trojf\u00e1zov\u00e9 meranie nap\u00e4tia, dvojf\u00e1zov\u00e9 z\u00edskavanie pr\u00fadu a meranie energie v jednom zariaden\u00ed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0160iroko sa pou\u017e\u00edva na meranie na st\u013apoch vonkaj\u0161\u00edch distribu\u010dn\u00fdch veden\u00ed 10 kV a je jedn\u00fdm z k\u013e\u00fa\u010dov\u00fdch merac\u00edch zariaden\u00ed pre trojf\u00e1zov\u00e9 trojvodi\u010dov\u00e9 nap\u00e1jacie syst\u00e9my.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Funkcie produktu<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Izol\u00e1cia a elektrick\u00fd v\u00fdkon<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Vonkaj\u0161ia epoxidov\u00e1 \u017eivicov\u00e1 odlievan\u00e1 izol\u00e1cia:<\/strong><br>Cel\u00e1 jednotka je v\u00e1kuovo odlievan\u00e1 pomocou epoxidovej \u017eivice pre vonkaj\u0161ie pou\u017eitie. Pevn\u00e1 izol\u00e1cia neobsahuje \u017eiadne vn\u00fatorn\u00e9 vzduchov\u00e9 medzery a poskytuje vynikaj\u00face dielektrick\u00e9 vlastnosti.<\/li>\n\n\n\n<li><strong>Vhodn\u00e9 pre syst\u00e9my 12 kV:<\/strong><br>Jednotka vydr\u017e\u00ed po\u017eiadavky na prev\u00e1dzkov\u00e9 nap\u00e4tie, odolnos\u0165 vo\u010di nap\u00e4tiu s frekvenciou v\u00fdkonu a odolnos\u0165 vo\u010di r\u00e1zov\u00e9mu nap\u00e4tiu pri \u00fadere blesku syst\u00e9mov 10 kV s maxim\u00e1lnym nap\u00e4t\u00edm syst\u00e9mu 12 kV.<\/li>\n\n\n\n<li><strong>N\u00edzky \u010diasto\u010dn\u00fd v\u00fdboj<\/strong><br>\u010ciasto\u010dn\u00fd v\u00fdboj je obmedzen\u00fd na maxim\u00e1lne 10 pC, \u010do pom\u00e1ha zni\u017eova\u0165 starnutie izol\u00e1cie a zlep\u0161uje dlhodob\u00fa prev\u00e1dzkov\u00fa spo\u013eahlivos\u0165.<\/li>\n\n\n\n<li><strong>Bezolejov\u00e1 vonkaj\u0161ia kon\u0161trukcia:<\/strong><br>V\u00fdrobok neobsahuje izola\u010dn\u00fd olej, \u010d\u00edm sa eliminuj\u00fa rizik\u00e1 \u00faniku oleja, kontamin\u00e1cie olejom a po\u017eiarov s\u00favisiacich s olejom. Je vhodn\u00fd do vonkaj\u0161ieho prostredia vystaven\u00e9ho slne\u010dn\u00e9mu \u017eiareniu, da\u017e\u010fu, vlhkosti a be\u017en\u00e9mu zne\u010disteniu.<\/li>\n\n\n\n<li><strong>Integrovan\u00e1 dvojprvkov\u00e1 meracia zostava:<\/strong><br>Jednotka je \u0161peci\u00e1lne navrhnut\u00e1 pre trojf\u00e1zov\u00e9 trojvodi\u010dov\u00e9 syst\u00e9my a integruje dva prvky pr\u00fadov\u00e9ho transform\u00e1tora f\u00e1zy s prvkom nap\u00e4\u0165ov\u00e9ho transform\u00e1tora.<\/li>\n\n\n\n<li><strong>S\u00fabe\u017en\u00e9 z\u00edskavanie sign\u00e1lov:<\/strong><br>M\u00f4\u017ee z\u00edska\u0165 trojf\u00e1zov\u00e9 nap\u00e4tie a dvojf\u00e1zov\u00e9 pr\u00fadov\u00e9 sign\u00e1ly na meranie energie, v\u00fdpo\u010det v\u00fdkonu a monitorovanie za\u0165a\u017eenia bez potreby dodato\u010dn\u00fdch extern\u00fdch transform\u00e1torov.<\/li>\n\n\n\n<li><strong>\u0160irok\u00fd rozsah pomeru<\/strong><br>K dispoz\u00edcii je \u0161tandardn\u00fd nap\u00e4\u0165ov\u00fd pomer 10\/0,1 kV, zatia\u013e \u010do pr\u00fadov\u00e9 pomery od 5\/5 A do 2 000\/5 A je mo\u017en\u00e9 konfigurova\u0165 pod\u013ea pripojenej z\u00e1\u0165a\u017ee.<\/li>\n\n\n\n<li><strong>Vysok\u00e1 presnos\u0165 merania:<\/strong><br>Dostupn\u00e9 s\u00fa pr\u00fadov\u00e9 transform\u00e1tory s triedou presnosti do 0,2S a nap\u00e4\u0165ov\u00e9 transform\u00e1tory s triedou presnosti do 0,2. Triedy 0,5 a 1 je mo\u017en\u00e9 doda\u0165 aj pod\u013ea po\u017eiadaviek projektu.<\/li>\n\n\n\n<li><strong>Vysok\u00e1 odolnos\u0165 proti zne\u010disteniu a preskokom<\/strong><br>Vysokonap\u00e4\u0165ov\u00e1 strana m\u00e1 viacvrstvov\u00fa izola\u010dn\u00fa \u0161trukt\u00faru s pred\u013a\u017eenou \u00fanikovou vzdialenos\u0165ou, ktor\u00e1 poskytuje spo\u013eahliv\u00fa odolnos\u0165 proti povrchov\u00e9mu preskoku za vlhk\u00fdch a zne\u010disten\u00fdch vonkaj\u0161\u00edch podmienok.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Kon\u0161truk\u010dn\u00e9 a in\u0161tala\u010dn\u00e9 vlastnosti<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Plne uzatvoren\u00e1 vonkaj\u0161ia such\u00e1 kon\u0161trukcia:<\/strong><br>Celokovov\u00e1 jednotka je tvoren\u00e1 integrovan\u00fdm telesom z liatej \u017eivice bez odkryt\u00fdch vn\u00fatorn\u00fdch \u010dast\u00ed pod nap\u00e4t\u00edm.<\/li>\n\n\n\n<li><strong>Ochrana IP65:<\/strong><br>Vonkaj\u0161\u00ed kryt poskytuje stupe\u0148 ochrany IP65, \u010d\u00edm pom\u00e1ha predch\u00e1dza\u0165 vniknutiu da\u017e\u010fovej vody, prachu a vlhkosti.<\/li>\n\n\n\n<li><strong>Kompaktn\u00fd integrovan\u00fd dizajn:<\/strong><br>Funkcie nap\u00e4\u0165ov\u00e9ho a pr\u00fadov\u00e9ho transform\u00e1tora s\u00fa spojen\u00e9 v jednom zariaden\u00ed, \u010d\u00edm sa zmen\u0161uje priestor potrebn\u00fd na in\u0161tal\u00e1ciu, zjednodu\u0161uje sa zapojenie v ter\u00e9ne a zni\u017euje sa po\u010det potrebn\u00fdch samostatn\u00fdch komponentov.<\/li>\n\n\n\n<li><strong>Alternat\u00edva k olejov\u00fdm merac\u00edm jednotk\u00e1m:<\/strong><br>Such\u00e1 kon\u0161trukcia m\u00f4\u017ee v vhodn\u00fdch aplik\u00e1ci\u00e1ch nahradi\u0165 konven\u010dn\u00e9 olejov\u00e9 meracie transform\u00e1tory a z\u00e1rove\u0148 odstra\u0148uje potrebu \u00fadr\u017eby oleja.<\/li>\n\n\n\n<li><strong>Vonkaj\u0161ie vysokonap\u00e4\u0165ov\u00e9 svorky:<\/strong><br>Vysokonap\u00e4\u0165ov\u00e1 strana pou\u017e\u00edva meden\u00e9 zbernicov\u00e9 svorky na pohodln\u00e9 pripojenie k vonkaj\u0161\u00edm distribu\u010dn\u00fdm vodi\u010dom.<\/li>\n\n\n\n<li><strong>Poc\u00ed<\/strong><br>Vysokonap\u00e4\u0165ov\u00e9 kontaktn\u00e9 plochy s\u00fa c\u00ednovan\u00e9 na zlep\u0161enie odolnosti proti oxid\u00e1cii a kor\u00f3zii vo vonkaj\u0161om prostred\u00ed.<\/li>\n\n\n\n<li><strong>Vodotesn\u00e1 sekund\u00e1rna pripojovacia skrinka:<\/strong><br>N\u00edzkonap\u00e4\u0165ov\u00e9 svorky s\u00fa umiestnen\u00e9 vo vodotesnej svorkovnici s kryt\u00edm IP65, aby chr\u00e1nili sekund\u00e1rne obvody pred da\u017e\u010fovou vodou a vlhkos\u0165ou.<\/li>\n\n\n\n<li><strong>Vymaza\u0165 identifik\u00e1ciu termin\u00e1lu:<\/strong><br>Vysokonap\u00e4\u0165ov\u00e9 svorky a sekund\u00e1rne obvody nap\u00e4tia a pr\u00fadu s\u00fa jasne ozna\u010den\u00e9 a oddelene zoskupen\u00e9, aby sa zn\u00ed\u017eilo riziko ch\u00fdb pri zapojen\u00ed.<\/li>\n\n\n\n<li><strong>Flexibiln\u00e1 in\u0161tal\u00e1cia:<\/strong><br>Jednotka podporuje vonkaj\u0161iu mont\u00e1\u017e na st\u013ap s prie\u010dnikom a vn\u00fatorn\u00fa <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear <\/a>\uc124\uce58.<\/li>\n\n\n\n<li><strong>Vysok\u00e1 mechanick\u00e1 stabilita:<\/strong><br>Mont\u00e1\u017ena kon\u0161trukcia poskytuje spo\u013eahliv\u00fa odolnos\u0165 vo\u010di vibr\u00e1ci\u00e1m a vetru a pri spr\u00e1vnej in\u0161tal\u00e1cii odol\u00e1 be\u017en\u00e9mu vonkaj\u0161iemu za\u0165a\u017eeniu vetrom, da\u017e\u010fom a snehom.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Prev\u00e1dzkov\u00e9 a \u00fadr\u017ebov\u00e9 funkcie<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>N\u00edzko\u00fadr\u017ebov\u00e1 prev\u00e1dzka:<\/strong><br>Such\u00e1, bezolejov\u00e1 kon\u0161trukcia eliminuje \u00fanik oleja, v\u00fdmenu oleja a rizik\u00e1 po\u017eiaru s\u00favisiace s olejom.<\/li>\n\n\n\n<li><strong>Vysok\u00e1 mechanick\u00e1 pevnos\u0165<\/strong><br>Vonkaj\u0161ie epoxidov\u00e9 telo poskytuje spo\u013eahliv\u00fa odolnos\u0165 proti n\u00e1razu, starnutiu a kor\u00f3zii.<\/li>\n\n\n\n<li><strong>\u0160irok\u00fd rozsah prev\u00e1dzkov\u00fdch tepl\u00f4t:<\/strong><br>Jednotka m\u00f4\u017ee pracova\u0165 pri okolit\u00fdch teplot\u00e1ch od -40\u00b0C do +70\u00b0C. Epoxidov\u00e1 \u017eivica si zachov\u00e1va stabiln\u00e9 izola\u010dn\u00e9 a mechanick\u00e9 vlastnosti bez krehnutia alebo deform\u00e1cie.<\/li>\n\n\n\n<li><strong>Vhodn\u00e9 pre vonkaj\u0161ie teplotn\u00e9 v\u00fdkyvy:<\/strong><br>V\u00fdrobok odol\u00e1 v\u00fdrazn\u00fdm zmen\u00e1m teploty po\u010das d\u0148a a noci a sez\u00f3nnym zmen\u00e1m.<\/li>\n\n\n\n<li><strong>Vysok\u00e1 prev\u00e1dzkov\u00e1 spo\u013eahlivos\u0165:<\/strong><br>Nap\u00e4\u0165ov\u00e9 a pr\u00fadov\u00e9 transform\u00e1torov\u00e9 komponenty vyu\u017e\u00edvaj\u00fa vysokokvalitn\u00e9 magnetick\u00e9 jadr\u00e1 a vinut\u00e9 materi\u00e1ly, \u010d\u00edm poskytuj\u00fa n\u00edzke prev\u00e1dzkov\u00e9 straty a obmedzen\u00fd n\u00e1rast teploty.<\/li>\n\n\n\n<li><strong>Stabiln\u00e1 dlhodob\u00e1 presnos\u0165:<\/strong><br>Jednotka je navr\u017eena tak, aby si udr\u017eovala stabiln\u00ed p\u0159esnost m\u011b\u0159en\u00ed s minim\u00e1ln\u00edm posunem chyb b\u011bhem dlouhodob\u00e9ho provozu.<\/li>\n\n\n\n<li><strong>Schopnos\u0165 odol\u00e1va\u0165 prep\u00e4tiu:<\/strong><br>V\u00fdrobok odol\u00e1va prep\u00e4\u0165ov\u00fdm a atmosf\u00e9rick\u00fdm prep\u00e4tiam v r\u00e1mci svojej \u0161pecifikovanej \u00farovne izol\u00e1cie.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Technical Specifications<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Elektrick\u00e9 parametre<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>\u0160pecifik\u00e1cia<\/th><\/tr><\/thead><tbody><tr><td>Pou\u017eite\u013en\u00e9 nap\u00e4tie syst\u00e9mu<\/td><td>10 kV striedav\u00e9ho pr\u00fadu, Um = 12 kV<\/td><\/tr><tr><td>Menovit\u00e1 frekvencia<\/td><td>50 Hz<\/td><\/tr><tr><td>Nap\u00e4tov\u00fd pomer<\/td><td>10\/0,1 kV, prisp\u00f4sobite\u013en\u00e9<\/td><\/tr><tr><td>Be\u017en\u00fd pomer<\/td><td>5\/5 A a\u017e 2 000\/5 A, prisp\u00f4sobite\u013en\u00e9<\/td><\/tr><tr><td>Triedna presnosti nap\u00e4\u0165ov\u00e9ho transform\u00e1tora<\/td><td>Trieda 0,2 \/ 0,5 \/ 1<\/td><\/tr><tr><td>Aktu\u00e1lna trieda presnosti transform\u00e1tora<\/td><td>Trieda 0,2S \/ 0,5S \/ 0,5<\/td><\/tr><tr><td>Nap\u00e4\u0165ov\u00e1 sk\u00fa\u0161ka s frekvenciou siete<\/td><td>42 kV po dobu 1 min\u00faty na vysokonap\u00e4\u0165ovom konci, bez prierazu<\/td><\/tr><tr><td>Impulzn\u00e1 odolnos\u0165 vo\u010di prep\u00e4tiu<\/td><td>75 kV \u0161pi\u010dkovo, bez prierazu<\/td><\/tr><tr><td>\u010ciasto\u010dn\u00fd v\u00fdboj<\/td><td>\u226410 pC<\/td><\/tr><tr><td>Izola\u010dn\u00fd odpor<\/td><td>\u22651,000 M\u03a9 between high voltage, low voltage, and earth<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Kon\u0161truk\u010dn\u00e9 a materi\u00e1lov\u00e9 parametre<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>\u0160pecifik\u00e1cia<\/th><\/tr><\/thead><tbody><tr><td>Izola\u010dn\u00fd materi\u00e1l<\/td><td>Plne zaliata epoxidov\u00e1 \u017eivica vonkaj\u0161ej kvality<\/td><\/tr><tr><td>Ochrann\u00e9 hodnotenie<\/td><td>IP65<\/td><\/tr><tr><td>Typ in\u0161tal\u00e1cie<\/td><td>Vonkaj\u0161ia mont\u00e1\u017e prie\u010dnej traverzy na sto\u017eiar alebo vn\u00fatorn\u00e1 mont\u00e1\u017e rozv\u00e1dza\u010da<\/td><\/tr><tr><td>Tepeln\u00e1 trieda<\/td><td>Trieda B, 130 \u00b0C<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Environment\u00e1lne parametre<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>\u0160pecifik\u00e1cia<\/th><\/tr><\/thead><tbody><tr><td>V\u00fd\u0161ka in\u0161tal\u00e1cie<\/td><td>\u22642 000 m; dostupn\u00e9 verzie pre vysokohorsk\u00e9 prostredie<\/td><\/tr><tr><td>Prev\u00e1dzkov\u00e1 teplota<\/td><td>-40 \u00b0C a\u017e +70 \u00b0C<\/td><\/tr><tr><td>Teplota skladovania<\/td><td>-40 \u00b0C a\u017e +85 \u00b0C<\/td><\/tr><tr><td>Relat\u00edvna vlhkos\u0165<\/td><td>\u226495%, nekondenzuj\u00faca<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Platn\u00e9 normy<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\ud45c\uc900<\/th><th>Popis<\/th><\/tr><\/thead><tbody><tr><td>GB 1207<\/td><td>Nap\u00e4\u0165ov\u00e9 transform\u00e1tory<\/td><\/tr><tr><td>GB 1208<\/td><td>Aktu\u00e1lne transform\u00e1tory<\/td><\/tr><tr><td>GB\/T 17215<\/td><td>Elektromerov\u00e9 zariadenia<\/td><\/tr><tr><td>DL\/T 448<\/td><td>Technick\u00fd administrat\u00edvny k\u00f3d pre meranie elektrickej energie<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Aplik\u00e1cie<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Pou\u017eite\u013en\u00fd silov\u00fd syst\u00e9m<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kombinovan\u00fd merac\u00ed transform\u00e1tor JLSZVW-10 je vhodn\u00fd pre trojf\u00e1zov\u00e9 trojvodi\u010dov\u00e9 striedav\u00e9 nap\u00e1jacie syst\u00e9my s nap\u00e4t\u00edm 10 kV s maxim\u00e1lnym nap\u00e4t\u00edm syst\u00e9mu 12 kV.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Typick\u00e9 aplik\u00e1cie<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Vonkaj\u0161ie meranie spotreby energie na 10 kV distribu\u010dn\u00fdch vedeniach na st\u013apoch<\/li>\n\n\n\n<li>Meranie energie a monitorovanie za\u0165a\u017eenia vo vn\u00fatorn\u00fdch rozv\u00e1dza\u010doch stredn\u00e9ho nap\u00e4tia<\/li>\n\n\n\n<li>Transform\u00e1torov\u00e9 stanice typu skri\u0148a<\/li>\n\n\n\n<li>Rozvodn\u00e9 a transforma\u010dn\u00e9 stanice<\/li>\n\n\n\n<li>10 kV rozvodn\u00e9 syst\u00e9my v priemyseln\u00fdch a bansk\u00fdch podnikoch<\/li>\n\n\n\n<li>Komercijalne zgrade i industrijski parkovi<\/li>\n\n\n\n<li>Z\u00edskavanie energetick\u00fdch \u00fadajov v syst\u00e9moch automatiz\u00e1cie energetiky<\/li>\n\n\n\n<li>Syst\u00e9my na monitorovanie, riadenie a spr\u00e1vu z\u00e1\u0165a\u017ee elektrickej energie<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Hlavn\u00e9 funkcie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kombinovan\u00fd merac\u00ed transform\u00e1tor premie\u0148a vysok\u00e9 nap\u00e4tie syst\u00e9mu a prim\u00e1rny pr\u00fad na \u0161tandardizovan\u00e9 sekund\u00e1rne sign\u00e1ly:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Sekund\u00e1rne nap\u00e4tie: 100 V<\/li>\n\n\n\n<li>Sekund\u00e1rny pr\u00fad: 5 A<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Tieto sign\u00e1ly m\u00f4\u017eu by\u0165 dodan\u00e9 do:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Trojf\u00e1zov\u00e9 trojvodi\u010dov\u00e9 elektromery<\/li>\n\n\n\n<li>Meracie pr\u00edstroje<\/li>\n\n\n\n<li>Vybavenie na monitorovanie za\u0165a\u017eenia<\/li>\n\n\n\n<li>Zariadenia na zber \u00fadajov o nap\u00e1jan\u00ed<\/li>\n\n\n\n<li>Syst\u00e9my riadenia energie<\/li>\n\n\n\n<li>Automatiza\u010dn\u00e9 zariadenia na pohon<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Jednotka podporuje:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Meranie energie<\/li>\n\n\n\n<li>V\u00fdpo\u010det v\u00fdkonu<\/li>\n\n\n\n<li>Sledovanie za\u0165a\u017eenia<\/li>\n\n\n\n<li>Z\u00edskavanie elektrick\u00fdch parametrov<\/li>\n\n\n\n<li>Spr\u00e1va spotreby energie<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Poskytuje tie\u017e elektrick\u00fa izol\u00e1ciu medzi prim\u00e1rnym nap\u00e1jac\u00edm syst\u00e9mom a sekund\u00e1rnymi merac\u00edmi obvodmi, \u010d\u00edm pom\u00e1ha zabezpe\u010di\u0165 bezpe\u010dn\u00e9 fungovanie pripojen\u00fdch merac\u00edch zariaden\u00ed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Prev\u00e1dzkov\u00e9 podmienky<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Norm\u00e1lne prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In\u0161tala\u010dn\u00e1 v\u00fd\u0161ka: maxim\u00e1lne 2 000 m<\/li>\n\n\n\n<li>Okolit\u00e1 teplota: -40 \u00b0C a\u017e +70 \u00b0C<\/li>\n\n\n\n<li>Vyhnite sa prudk\u00fdm alebo n\u00e1hlym zmen\u00e1m teploty.<\/li>\n\n\n\n<li>Relat\u00edvna vlhkos\u0165: maxim\u00e1lne 95 %, nekondenzuj\u00faca<\/li>\n\n\n\n<li>Prostredie by malo by\u0165 bez koroz\u00edvnych plynov<\/li>\n\n\n\n<li>Hor\u013eav\u00e9 alebo v\u00fdbu\u0161n\u00e9 l\u00e1tky nie s\u00fa povolen\u00e9<\/li>\n\n\n\n<li>Siln\u00e9 vibr\u00e1cie a mechanick\u00e9 n\u00e1razy by sa mali vyhn\u00fa\u0165<\/li>\n\n\n\n<li>Vonkaj\u0161ie modely odolaj\u00fa be\u017en\u00e9mu slne\u010dn\u00e9mu \u017eiareniu, da\u017e\u010fu, mrazu a vetru.<\/li>\n\n\n\n<li>Vonkaj\u0161ia mont\u00e1\u017e na st\u013ap s prie\u010dnym ramenom alebo vn\u00fatorn\u00e1 in\u0161tal\u00e1cia rozvodn\u00fdch skr\u00ed\u0148<\/li>\n\n\n\n<li>\u0164a\u017ek\u00e1 kor\u00f3zia, so\u013en\u00e1 hmla a siln\u00e9 pieso\u010dnat\u00e9 alebo pra\u0161n\u00e9 podmienky by sa mali vyhn\u00fa\u0165, pokia\u013e sa nepou\u017e\u00edva prisp\u00f4soben\u00e1 verzia<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160peci\u00e1lne prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prisp\u00f4soben\u00e9 produkty s\u00fa potrebn\u00e9 pre:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nadmo\u0159sk\u00e9 v\u00fd\u0161ky instalace nad 2 000 m<\/li>\n\n\n\n<li>Teploty okolia mimo rozsah -40 \u00b0C a\u017e +70 \u00b0C<\/li>\n\n\n\n<li>\u0164a\u017ek\u00e9 zne\u010distenie alebo prostredie so slanou hmlou<\/li>\n\n\n\n<li>Chemicky korozivn\u00ed prost\u0159ed\u00ed<\/li>\n\n\n\n<li>Siln\u00fd vietor alebo siln\u00e9 pieso\u010dn\u00e9 a prachov\u00e9 podmienky<\/li>\n\n\n\n<li>Vysokointenz\u00edvne ultrafialov\u00e9 \u017eiarenie<\/li>\n\n\n\n<li>Nestandardn\u00e9 prevodov\u00e9 pomery<\/li>\n\n\n\n<li>Nestandardn\u00e9 pomery be\u017enej prev\u00e1dzky<\/li>\n\n\n\n<li>\u0160peci\u00e1lne mont\u00e1\u017ene rozmery<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">In\u0161tal\u00e1cia a \u00fadr\u017eba<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na in\u0161tal\u00e1ciu<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Predin\u0161tala\u010dn\u00e1 kontrola:<\/strong><br>Skontrolujte kombinovan\u00fd merac\u00ed transform\u00e1tor a uistite sa, \u017ee epoxidov\u00e9 teleso je bez praskl\u00edn, bubl\u00edn, mechanick\u00e9ho po\u0161kodenia a in\u00fdch vidite\u013en\u00fdch ch\u00fdb. Skontrolujte, \u010di s\u00fa v\u0161etky ozna\u010denia svoriek jasn\u00e9 a \u010di dodan\u00e9 pr\u00edslu\u0161enstvo je kompletn\u00e9. Overte, \u017ee model, \u0161pecifik\u00e1cie, nap\u00e4\u0165ov\u00fd pomer, pr\u00fadov\u00fd pomer a triedy presnosti merania zodpovedaj\u00fa po\u017eiadavk\u00e1m n\u00e1vrhu syst\u00e9mu.<\/li>\n\n\n\n<li><strong>Mont\u00e1\u017e:<\/strong><br>\uc124\uce58 \uad6c\uc131\uc5d0 \ub530\ub77c \uc801\uc808\ud55c \ud06c\ub85c\uc2a4\uc554\uacfc \uc7a5\ucc29 \ube0c\ub798\ud0b7\uc744 \uc120\ud0dd\ud558\uc2ed\uc2dc\uc624. \uacc4\uae30\uc6a9 \ubcc0\uc555\uae30\ub97c \uc9c0\uc815\ub41c \uc704\uce58\uc5d0 \uace0\uc815\ud558\uace0 \ud5d0\uac70\uc6c0, \ubcc0\uc704 \ub610\ub294 \ubd88\uade0\uc77c\ud55c \uae30\uacc4\uc801 \ud558\uc911\uc774 \uc5c6\ub294\uc9c0 \ud655\uc778\ud558\uc2ed\uc2dc\uc624. \uc7a5\ucc29 \ud45c\uba74\uc740 \uc218\ud3c9\uc774\uc5b4\uc57c \ud569\ub2c8\ub2e4. \uc2e4\uc678 \uae30\ub465 \uc124\uce58\ub294 \ud574\ub2f9 \ud48d\ud558\uc911 \ubc0f \uc804\ubcf5 \ubc29\uc9c0 \uc694\uad6c \uc0ac\ud56d\uc744 \ucda9\uc871\ud574\uc57c \ud569\ub2c8\ub2e4.<\/li>\n\n\n\n<li><strong>Pripo<\/strong><br>Vysokonap\u00e4\u0165ov\u00e9 svorky pripojte pod\u013ea n\u00e1vrhu syst\u00e9mu. Zaistite, aby v\u0161etky spoje boli pevne utiahnut\u00e9 a poskytovali spo\u013eahliv\u00fd elektrick\u00fd kontakt. Dodr\u017eiavajte dostato\u010dn\u00e9 elektrick\u00e9 vzdialenosti medzi vysokonap\u00e4\u0165ov\u00fdmi vodi\u010dmi, uzemnen\u00fdmi komponentmi a in\u00fdmi \u017eiv\u00fdmi \u010das\u0165ami. Vonkaj\u0161ie spoje musia by\u0165 chr\u00e1nen\u00e9 proti vniknutiu vody a kor\u00f3zii. Na kontaktn\u00e9 plochy svoriek, kde je to potrebn\u00e9, naneste vodiv\u00fa spojovaciu pastu na zn\u00ed\u017eenie oxid\u00e1cie.<\/li>\n\n\n\n<li><strong>Sekund\u00e1rne pripojenie:<\/strong><br>Nap\u00e4tie a pr\u00fadov\u00e9 sekund\u00e1rne svorky pripojte k elektromeru pod\u013ea ich ozna\u010denia. Sekund\u00e1rny obvod pr\u00fadov\u00e9ho transform\u00e1tora nesmie zosta\u0165 otvoren\u00fd, ke\u010f je prim\u00e1rny obvod pod nap\u00e4t\u00edm. Sekund\u00e1rny obvod nap\u00e4\u0165ov\u00e9ho transform\u00e1tora nesmie by\u0165 skratovan\u00fd. Sekund\u00e1rny obvod pr\u00fadu mus\u00ed by\u0165 spo\u013eahlivo uzemnen\u00fd v jednom bode v s\u00falade s n\u00e1vrhom syst\u00e9mu a platn\u00fdmi po\u017eiadavkami na elektrick\u00fa bezpe\u010dnos\u0165. Po zapojen\u00ed sa uistite, \u017ee je vodotesn\u00e1 sekund\u00e1rna svorkovnica spr\u00e1vne zatvoren\u00e1 a utesnen\u00e1.<\/li>\n\n\n\n<li><strong>Kontrola izol\u00e1cie:<\/strong><br>Po in\u0161tal\u00e1cii zmerajte izola\u010dn\u00fd odpor medzi:<ul><li>Vysok\u00e9 nap\u00e4tie a n\u00edzke nap\u00e4tie<\/li><li>Vysok\u00e9 nap\u00e4tie a zem<\/li><li>N\u00edzke nap\u00e4tie a zem<\/li><\/ul>Potvr\u010fte, \u017ee v\u0161etky sekund\u00e1rne obvody s\u00fa spr\u00e1vne pripojen\u00e9 a bez ne\u00famyseln\u00fdch preru\u0161en\u00ed alebo skratov. Pred zapnut\u00edm syst\u00e9mu skontrolujte pripojenie elektromera a poradie f\u00e1z.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na \u00fadr\u017ebu<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pravidelne kontrolujte epoxidov\u00e9 teleso na praskliny, mechanick\u00e9 po\u0161kodenia, stopy po v\u00fdbojoch a zne\u010distenie.<\/li>\n\n\n\n<li>Skontrolujte vysokonap\u00e4\u0165ov\u00e9 svorky, \u010di nie s\u00fa uvo\u013enen\u00e9, skorodovan\u00e9, zoxidovan\u00e9 a \u010di nevykazuj\u00fa abnorm\u00e1lne zahrievanie.<\/li>\n\n\n\n<li>Skontrolujte vodotesnos\u0165 a ochranu proti kor\u00f3zii v\u0161etk\u00fdch vonkaj\u0161\u00edch spojen\u00ed.<\/li>\n\n\n\n<li>Potvr\u010fte, \u017ee sekund\u00e1rna svorkovnica zost\u00e1va riadne utesnen\u00e1.<\/li>\n\n\n\n<li>Pravidelne kontrolujte vysokonap\u00e4\u0165ov\u00e9 a n\u00edzkonap\u00e4\u0165ov\u00e9 spoje, \u010di nie s\u00fa uvo\u013enen\u00e9, prehriate a zafarben\u00e9.<\/li>\n\n\n\n<li>Potvr\u010fte, \u017ee sekund\u00e1rny obvod zost\u00e1va spr\u00e1vne pripojen\u00fd a spo\u013eahlivo uzemnen\u00fd.<\/li>\n\n\n\n<li>Pravidelne overujte presnos\u0165 merania a porovn\u00e1vajte \u00fadaje mera\u010da s predp\u00edsan\u00fdmi limitmi ch\u00fdb kombinovan\u00e9ho meracieho transform\u00e1tora.<\/li>\n\n\n\n<li>Pravidelne testujte izola\u010dn\u00fd odpor a overte, \u010di izola\u010dn\u00fd v\u00fdkon zost\u00e1va v r\u00e1mci stanoven\u00fdch po\u017eiadaviek.<\/li>\n\n\n\n<li>Vy\u010distite prach a ne\u010distoty z povrchu v\u00fdrobku.<\/li>\n\n\n\n<li>Pravidelne \u010distite izola\u010dn\u00e9 obj\u00edmky, aby ste zn\u00ed\u017eili riziko zne\u010distenia a preskoku.<\/li>\n\n\n\n<li>Zabr\u00e1\u0148te kontaktu oleja a koroz\u00edvnych l\u00e1tok s epoxidov\u00fdm telesom.<\/li>\n\n\n\n<li>Ak sa zist\u00ed praskanie, elektrick\u00fd v\u00fdboj, prehriatie alebo nadmern\u00e1 chyba merania, okam\u017eite vypnite nap\u00e1janie a skontrolujte zariadenie. V pr\u00edpade potreby vyme\u0148te jednotku.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Opatrenia<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Sekund\u00e1rny obvod pr\u00fadov\u00e9ho transform\u00e1tora nesmie by\u0165 nikdy ponechan\u00fd otvoren\u00fd, ke\u010f je prim\u00e1rny syst\u00e9m pod nap\u00e4t\u00edm. Sekund\u00e1rny obvod nap\u00e4\u0165ov\u00e9ho transform\u00e1tora nesmie by\u0165 nikdy skratovan\u00fd. Ka\u017ed\u00fd z t\u00fdchto stavov m\u00f4\u017ee sp\u00f4sobi\u0165 nebezpe\u010dn\u00e9 prep\u00e4tie alebo nadpr\u00fad a predstavova\u0165 v\u00e1\u017ene riziko pre zariadenie a person\u00e1l.<\/li>\n\n\n\n<li>Pri \u00fadr\u017ebe mus\u00ed by\u0165 sekund\u00e1rny obvod bezpe\u010dne skratovan\u00fd a uzemnen\u00fd pred odpojen\u00edm. Sekund\u00e1rny obvod nap\u00e4tia mus\u00ed by\u0165 pred za\u010dat\u00edm pr\u00e1c bezpe\u010dne izolovan\u00fd.<\/li>\n\n\n\n<li>Prepravou a in\u0161tal\u00e1ciou sa vyhnite n\u00e1razom alebo kol\u00edzi\u00e1m s telesom z epoxidovej \u017eivice a vysokonap\u00e4\u0165ov\u00fdmi svorkami. Mechanick\u00e9 po\u0161kodenie m\u00f4\u017ee zn\u00ed\u017ei\u0165 izola\u010dn\u00fd v\u00fdkon a odolnos\u0165 proti zne\u010disteniu a preskoku.<\/li>\n\n\n\n<li>Pou\u017eite vhodn\u00e9 izolovan\u00e9 vodi\u010de pre vysokonap\u00e4\u0165ov\u00e9 pripojenia. Udr\u017eujte dostato\u010dn\u00fa elektrick\u00fa vzdialenos\u0165 od uzemnen\u00fdch \u010dast\u00ed a in\u00fdch \u010dast\u00ed pod nap\u00e4t\u00edm, aby ste zabr\u00e1nili v\u00fdboju medzi f\u00e1zami alebo medzi f\u00e1zou a zemou.<\/li>\n\n\n\n<li>Potvr\u010fte spr\u00e1vne poradie f\u00e1z pri trojf\u00e1zovom zapojen\u00ed. Nespr\u00e1vne pripojenie f\u00e1z m\u00f4\u017ee ovplyvni\u0165 presnos\u0165 merania.<\/li>\n\n\n\n<li>Zariadenie mus\u00ed by\u0165 spo\u013eahlivo uzemnen\u00e9. Uzem\u0148ovacia svorka na z\u00e1kladni mus\u00ed by\u0165 pevne pripojen\u00e1 k uzem\u0148ovacej zbernici.<\/li>\n\n\n\n<li>Vonkaj\u0161ie in\u0161tal\u00e1cie musia sp\u013a\u0148a\u0165 pr\u00edslu\u0161n\u00e9 po\u017eiadavky na ochranu pred bleskom a uzemnenie.<\/li>\n\n\n\n<li>Skladujte<\/li>\n\n\n\n<li>In\u0161tal\u00e1ciu, uvedenie do prev\u00e1dzky a \u00fadr\u017ebu musia vykon\u00e1va\u0165 kvalifikovan\u00ed elektrik\u00e1ri v s\u00falade s platn\u00fdmi predpismi o bezpe\u010dnosti elektrick\u00fdch in\u0161tal\u00e1ci\u00ed.<\/li>\n\n\n\n<li>Vonkaj\u0161ie spoje musia by\u0165 riadne chr\u00e1nen\u00e9 proti vniknutiu da\u017e\u010fovej vody a kor\u00f3zii.<\/li>\n\n\n\n<li>Mera\u010d transform\u00e1tor mus\u00ed pred uveden\u00edm do prev\u00e1dzky prejs\u0165 overen\u00edm pr\u00edslu\u0161n\u00fdm miestnym metrologick\u00fdm org\u00e1nom, ak je tak\u00e9to overenie vy\u017eadovan\u00e9.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160tandardn\u00fd zoznam dod\u00e1vok<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Nie.<\/th><th>Predmet<\/th><th>Funkcia<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>JLSZVW-10 Vonkaj\u0161\u00ed kombinovan\u00fd merac\u00ed transform\u00e1tor s dvoma prvkami<\/td><td>Hlavn\u00e9 zariadenie na transform\u00e1ciu nap\u00e4tia a pr\u00fadu, elektrick\u00fa izol\u00e1ciu a meranie energie<\/td><\/tr><tr><td>2<\/td><td>Mont\u00e1\u017ene dr\u017eiaky, skrutky a podlo\u017eky<\/td><td>Pou\u017e\u00edva sa na zaistenie meracieho transform\u00e1tora po\u010das in\u0161tal\u00e1cie<\/td><\/tr><tr><td>3<\/td><td>Sekund\u00e1rna svorkovnicov\u00e1 skrinka a kryt svorkovnice<\/td><td>Chr\u00e1\u0148te n\u00edzkonap\u00e4\u0165ov\u00e9 svorky pred nespr\u00e1vnym pripojen\u00edm, skratmi a vniknut\u00edm vody<\/td><\/tr><tr><td>4<\/td><td>N\u00e1vod na pou\u017eitie<\/td><td>Poskytuje pokyny na in\u0161tal\u00e1ciu, prev\u00e1dzku, \u00fadr\u017ebu, zapojenie a vonkaj\u0161iu mont\u00e1\u017e<\/td><\/tr><tr><td>5<\/td><td>Certifik\u00e1t v\u00fdrobku, Spr\u00e1va o sk\u00fa\u0161ke vo v\u00fdrobe a Osved\u010denie o metrologickom overen\u00ed<\/td><td>Poskytnite dokument\u00e1ciu kvality a v\u00fdkonu produktu, vr\u00e1tane \u00fadajov z testov pomeru nap\u00e4tia, pomeru pr\u00fadu a presnosti<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Platn\u00e9 normy a certifik\u00e1cia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobok sp\u013a\u0148a nasleduj\u00face normy:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GB 1207, <em>Nap\u00e4\u0165ov\u00e9 transform\u00e1tory<\/em><\/li>\n\n\n\n<li>GB 1208, <em>Aktu\u00e1lne transform\u00e1tory<\/em><\/li>\n\n\n\n<li>GB\/T 17215, <em>Elektromerov\u00e9 zariadenia<\/em><\/li>\n\n\n\n<li>DL\/T 448, <em>Technick\u00fd administrat\u00edvny k\u00f3d pre meranie elektrickej energie<\/em><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobok \u00faspe\u0161ne absolvoval pr\u00edslu\u0161n\u00e9 typov\u00e9 sk\u00fa\u0161ky a metrologick\u00e9 overenie. Jeho v\u00fdkon sp\u013a\u0148a po\u017eiadavky na meranie energie v trojf\u00e1zov\u00fdch trojvodi\u010dov\u00fdch nap\u00e1jac\u00edch syst\u00e9moch 10 kV.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"989\" height=\"653\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZVW-10-Combined-Metering-Transformer.webp\" alt=\"JLSZVW-10 Kombinovan\u00fd merac\u00ed transform\u00e1tor\" class=\"wp-image-2588\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZVW-10-Combined-Metering-Transformer.webp 989w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZVW-10-Combined-Metering-Transformer-300x198.webp 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZVW-10-Combined-Metering-Transformer-768x507.webp 768w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/05\/JLSZVW-10-Combined-Metering-Transformer-18x12.webp 18w\" sizes=\"(max-width: 989px) 100vw, 989px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The JLSZVW-10 Combined Metering Transformer is an outdoor epoxy resin cast energy-metering unit designed for 10 kV three-phase [&hellip;]<\/p>\n","protected":false},"featured_media":2588,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[30],"class_list":["post-1626","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-instrument-transformer-series"],"acf":{"products_imagines":[2588],"short_describe":"<p>The JLSZVW-10 Combined Metering Transformer is an outdoor epoxy resin cast energy-metering unit designed for 10 kV three-phase three-wire AC power systems with a maximum system voltage of 12 kV.<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/1626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/2588"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/2588"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=1626"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=1626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}