{"id":315,"date":"2026-01-23T02:45:57","date_gmt":"2026-01-23T02:45:57","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=315"},"modified":"2026-09-15T07:36:23","modified_gmt":"2026-09-15T07:36:23","slug":"t-shaped-american-front-connector","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/t-shaped-american-front-connector\/","title":{"rendered":"JY QJT-600 15kV\/24kV 600A T\u578b\u7f8e\u5f0f\u524d\u63a5\u5934"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>I. Preh\u013ead produktu<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">JY QJT-600 15kV\/24kV 600A T\u578b\u7f8e\u5f0f\u524d\u63a5\u5934<\/a> je \u0161tandardn\u00fd americk\u00fd nevyp\u00ednac\u00ed <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_cable\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_cable\" target=\"_blank\" rel=\"noopener\">cable <\/a>pr\u00edslu\u0161enstvo \u0161peci\u00e1lne navrhnut\u00e9 pre strednonap\u00e4\u0165ov\u00e9 distribu\u010dn\u00e9 syst\u00e9my 15kV\/24kV (\u00farove\u0148 10kV\/20kV). Vyzna\u010duje sa plne izolovanou, plne utesnenou, dotykovo bezpe\u010dnou kon\u0161trukciou v tvare T a sl\u00fa\u017ei ako predn\u00e9 pripojenie medzi k\u00e1blov\u00fdmi vedeniami a zariadeniami na distrib\u00faciu energie. Dosahuje izolovan\u00e9 a utesnen\u00e9 spojenie medzi priechodkou zariadenia a dvoma k\u00e1blami, pri\u010dom z\u00e1rove\u0148 poskytuje funkcie vetvenia vedenia, vodiv\u00e9ho pripojenia a ochrany uzemnenia. \u0160iroko sa pou\u017e\u00edva v americk\u00fdch prstencov\u00fdch hlavn\u00fdch jednotk\u00e1ch, prefabrikovan\u00fdch transformovniach, k\u00e1blov\u00fdch odbo\u010dn\u00fdch skriniach a in\u00fdch zariadeniach a je k\u013e\u00fa\u010dovou s\u00fa\u010das\u0165ou pri kon\u0161trukcii rozhran\u00ed pre americk\u00e9 strednonap\u00e4\u0165ov\u00e9 distribu\u010dn\u00e9 syst\u00e9my.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II. Product Characteristics<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Electrical and insulation properties<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Vyroben\u00e9 z <strong>vysoko\u010dist\u00e1 EPDM etyl\u00e9n-propyl\u00e9n-di\u00e9nov\u00fd kau\u010duk<\/strong> prostredn\u00edctvom integr\u00e1lneho vstrekovania nem\u00e1 \u017eiadne \u0161vy ani vzduchov\u00e9 medzery, vynikaj\u00faci izola\u010dn\u00fd v\u00fdkon, vydr\u017e\u00ed menovit\u00e9 nap\u00e4tie syst\u00e9mu 15kV\/24kV a kr\u00e1tkodob\u00e9 prep\u00e4tie, sp\u013a\u0148a prev\u00e1dzkov\u00e9 po\u017eiadavky maxim\u00e1lneho pracovn\u00e9ho nap\u00e4tia 17,5kV\/24kV a m\u00e1 dostato\u010dn\u00fa izola\u010dn\u00fa rezervu.<\/li>\n\n\n\n<li>Vn\u00fatorn\u00e1 \u0161trukt\u00fara optimaliz\u00e1cie elektrick\u00e9ho po\u013ea a vrstva kontroly nap\u00e4tia zabezpe\u010duj\u00fa rovnomern\u00e9 rozlo\u017eenie elektrick\u00e9ho po\u013ea, \u010d\u00edm \u00fa\u010dinne potl\u00e1\u010daj\u00fa \u010diasto\u010dn\u00e9 v\u00fdboje. Po\u010das dlhodobej prev\u00e1dzky nehroz\u00ed elektrick\u00e1 er\u00f3zia ani prieraz a mno\u017estvo \u010diasto\u010dn\u00fdch v\u00fdbojov je \u226410pC (1,5U\u2080).<\/li>\n\n\n\n<li>Obsahuje vstavan\u00e9 ve\u013ekoplo\u0161n\u00e9 meden\u00e9 vodiv\u00e9 komponenty, vynikaj\u00facu vodivos\u0165, n\u00edzky kontaktn\u00fd odpor, dok\u00e1\u017ee pren\u00e1\u0161a\u0165 menovit\u00fd pr\u00fad 600 A, generuje m\u00e1lo tepla po\u010das dlhodobej prev\u00e1dzky a m\u00e1 siln\u00fa odolnos\u0165 proti kor\u00f3zii a oxid\u00e1cii, v\u010faka \u010domu je vhodn\u00fd pre scen\u00e1re vysokopr\u00fadovej distrib\u00facie energie.<\/li>\n\n\n\n<li>M\u00e1 zabudovan\u00fa uzem\u0148ovaciu kon\u0161trukciu, ktor\u00e1 umo\u017e\u0148uje spo\u013eahliv\u00e9 uzemnenie, efekt\u00edvne uvo\u013e\u0148ovanie pr\u00fadov pri poruche a indukovan\u00fdch nap\u00e4t\u00ed a m\u00f4\u017ee by\u0165 vybaven\u00e1 zariaden\u00edm na zobrazenie nap\u00e4tia na intuit\u00edvne monitorovanie stavu pod nap\u00e4t\u00edm a elimin\u00e1ciu rizika nespr\u00e1vnej obsluhy.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Structural and Safety Features<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>V\u010faka plne izolovanej, plne utesnenej a dotykovej kon\u0161trukcii m\u00e1 vonkaj\u0161ia vrstva vysok\u00fa izola\u010dn\u00fa pevnos\u0165, \u010do umo\u017e\u0148uje priamy kontakt s vonkaj\u0161\u00edm krytom po\u010das prev\u00e1dzky bez rizika \u00farazu elektrick\u00fdm pr\u00fadom, \u010d\u00edm sa zais\u0165uje bezpe\u010dnos\u0165 \u00fadr\u017ebov\u00e9ho person\u00e1lu.<\/li>\n\n\n\n<li>T\u578b\u4e09\u901a\u4e00\u4f53\u5316\u8bbe\u8ba1\uff0c\u517c\u5bb9\u7f8e\u680715kV\/24kV 600A\u6807\u51c6\u63a5\u53e3\u3002\u4e00\u7aef\u8fde\u63a5\u8bbe\u5907\u5957\u7ba1\uff0c\u4e24\u7aef\u8fde\u63a5\u7535\u7f06\u9644\u4ef6\uff0c\u5b9e\u73b0\u201c\u4e00\u8fdb\u4e24\u51fa\u201d\u7ebf\u8def\u5206\u652f\u3002\u7ed3\u6784\u7d27\u51d1\uff0c\u5b89\u88c5\u65b9\u4fbf\uff0c\u65e0\u9700\u989d\u5916\u9002\u914d\u5668\u3002<\/li>\n\n\n\n<li>Dizajn zabra\u0148uje nespr\u00e1vnemu zasunutiu a pripojeniu. Ve\u013ekos\u0165 rozhrania presne zodpoved\u00e1 americk\u00fdm \u0161tandardn\u00fdm pr\u00edslu\u0161enstv\u00e1m a d\u00e1 sa sp\u00e1rova\u0165 iba s pr\u00edslu\u0161enstvom zodpovedaj\u00facich \u0161pecifik\u00e1ci\u00ed, \u010d\u00edm sa zabr\u00e1ni zmie\u0161aniu pr\u00edslu\u0161enstva r\u00f4znych \u0161pecifik\u00e1ci\u00ed. M\u00e1 zabudovan\u00fa polohovaciu a uzamykaciu \u0161trukt\u00faru, ktor\u00e1 zabra\u0148uje uvo\u013eneniu a p\u00e1du po in\u0161tal\u00e1cii.<\/li>\n\n\n\n<li>Vybaven\u00fd integrovan\u00fdm prev\u00e1dzkov\u00fdm kr\u00fa\u017ekom a kompatibiln\u00fd so \u0161pecializovanou izolovanou prev\u00e1dzkovou ty\u010dou umo\u017e\u0148uje bezpe\u010dn\u00e9 pripojenie a prehr\u00e1vanie a zlep\u0161uje pohodlie pri prev\u00e1dzke a \u00fadr\u017ebe.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. Odolnos\u0165 vo\u010di \u017eivotn\u00e9mu prostrediu a poveternostn\u00fdm vplyvom<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>M\u00e1 vynikaj\u00facu odolnos\u0165 vo\u010di poveternostn\u00fdm vplyvom a dok\u00e1\u017ee sa prisp\u00f4sobi\u0165 \u0161irok\u00e9mu rozsahu tepl\u00f4t od -40\u2103 do +90\u2103. Pru\u017enos\u0165 a izola\u010dn\u00e9 vlastnosti gumy neklesaj\u00fa pri vysok\u00fdch a n\u00edzkych teplot\u00e1ch a nehroz\u00ed riziko prasknutia alebo skrehnutia. Je vhodn\u00fd pre r\u00f4zne vonkaj\u0161ie a vn\u00fatorn\u00e9 prostredia.<\/li>\n\n\n\n<li>\u9632\u6f6e\u3001\u9632\u6c34\u3001\u9632\u6c61\u3001\u9632\u76d0\u96fe\uff0cIP67\u9632\u62a4\u7b49\u7ea7\uff0c\u53ef\u5728\u5730\u4e0b\u3001\u6f6e\u6e7f\u3001\u591a\u5c18\u7b49\u6076\u52a3\u73af\u5883\u4e0b\u957f\u671f\u7a33\u5b9a\u8fd0\u884c\uff0c\u65e0\u60e7\u96e8\u6c34\u6216\u51b7\u51dd\u8150\u8680\u3002<\/li>\n\n\n\n<li>Odoln\u00fd vo\u010di starnutiu, UV \u017eiareniu a oz\u00f3novej kor\u00f3zii, s \u017eivotnos\u0165ou viac ako 30 rokov. Nevy\u017eaduje \u017eiadnu \u00fadr\u017ebu a zni\u017euje n\u00e1sledn\u00e9 prev\u00e1dzkov\u00e9 a servisn\u00e9 n\u00e1klady.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4. Mechanical and Adaptation Characteristics<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>M\u00e1 vysok\u00fa mechanick\u00fa pevnos\u0165, je odoln\u00e9 vo\u010di n\u00e1razom a vibr\u00e1ci\u00e1m a odol\u00e1va mechanick\u00e9mu nam\u00e1haniu po\u010das prepravy, in\u0161tal\u00e1cie a prev\u00e1dzky bez rizika deform\u00e1cie alebo po\u0161kodenia. Jeho seizmick\u00e1 odolnos\u0165 dosahuje \u00farove\u0148 8.<\/li>\n\n\n\n<li>Je kompatibiln\u00fd s americk\u00fdmi \u0161tandardn\u00fdmi rozhraniami pre priechodky 15kV\/24kV 600A a je zamenite\u013en\u00fd s americk\u00fdmi lak\u0165ov\u00fdmi k\u00e1blov\u00fdmi spojkami, sedlami priechodiek a izola\u010dn\u00fdmi krytkami rovnak\u00fdch \u0161pecifik\u00e1ci\u00ed, \u010do z neho rob\u00ed vysoko univerz\u00e1lny.<\/li>\n\n\n\n<li>Rozhranie je \u0161tandardizovan\u00e9 a zodpoved\u00e1 norme IEEE 386 a relevantn\u00fdm dom\u00e1cim norm\u00e1m. M\u00f4\u017ee by\u0165 prisp\u00f4soben\u00e9 rozhraniu priechodiek hlavn\u00fdch americk\u00fdch distribu\u010dn\u00fdch energetick\u00fdch zariaden\u00ed 15kV\/24kV na realiz\u00e1ciu spojenia medzi zariaden\u00edm a k\u00e1blom a vetvenia veden\u00ed.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>III. Technick\u00e9 parametre<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Parameter categories<\/td><td>project<\/td><td>Technical indicators<\/td><\/tr><tr><td>Rated electrical parameters<\/td><td>Rated voltage (Ue)<\/td><td>15kV\/24kV (Vz\u0165ahuje sa na syst\u00e9my 10kV\/20kV, maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie 17,5kV\/24kV)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Menovit\u00fd pr\u00fad (Ie)<\/td><td>600A<\/td><\/tr><tr><td>&nbsp;<\/td><td>Rated frequency (fn)<\/td><td>50Hz\/60Hz<\/td><\/tr><tr><td>&nbsp;<\/td><td>Power frequency withstand voltage<\/td><td>42kV\/5min (15kV such\u00fd test), 65kV\/5min (24kV such\u00fd test), bez prierazu, bez preskoku.<\/td><\/tr><tr><td>&nbsp;<\/td><td>Lightning impulse withstand voltage<\/td><td>95kV (15kV \u0161pi\u010dkovo) a 125kV (24kV \u0161pi\u010dkovo), bez prierazu a bez preskoku.<\/td><\/tr><tr><td>&nbsp;<\/td><td>Partial discharge quantity<\/td><td>\u226410pC (below 1.5U\u2080)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Rated short-circuit withstand current<\/td><td>20kA\/2s (25kA\/2s volite\u013en\u00e9, v z\u00e1vislosti od po\u017eiadaviek syst\u00e9mu)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Contact resistance<\/td><td>\u226450\u03bc\u03a9<\/td><\/tr><tr><td>Structural and material parameters<\/td><td>Main material<\/td><td>EPDM (etyl\u00e9n-propyl\u00e9n-di\u00e9nov\u00fd kau\u010duk) (izola\u010dn\u00e1 vrstva), poc\u00ednovan\u00e1 me\u010f (vodiv\u00e9 kontakty)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Protection level<\/td><td>IP67<\/td><\/tr><tr><td>&nbsp;<\/td><td>\uc778\ud130\ud398\uc774\uc2a4 \ud45c\uc900<\/td><td>1 vstupn\u00fd termin\u00e1l (americk\u00fd \u0161tandard 15kV\/24kV 600A rozhranie pre priechodku zariadenia), 2 v\u00fdstupn\u00e9 termin\u00e1ly (americk\u00fd \u0161tandard 15kV\/24kV 600A rozhranie pre k\u00e1blov\u00e9 pr\u00edslu\u0161enstvo)<\/td><\/tr><tr><td>&nbsp;<\/td><td>uzem\u0148ovacia met\u00f3da<\/td><td>M\u00e1 zabudovan\u00fd uzem\u0148ovac\u00ed svorkovnicov\u00fd spoj a m\u00f4\u017ee by\u0165 priamo uzemnen\u00fd.<\/td><\/tr><tr><td>Environmental parameters<\/td><td>Applicable altitude<\/td><td>\u22642000m (Customization available for high altitudes)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Ambient temperature<\/td><td>-40\u2103\/ +90\u2103 (operating temperature), -40\u2103\/ +70\u2103 (storage temperature)<\/td><\/tr><tr><td>&nbsp;<\/td><td>relative humidity<\/td><td>\u2264100% (bez kondenz\u00e1cie)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Seismic resistance level<\/td><td>Level 8<\/td><\/tr><tr><td>Implementation Standards<\/td><td>&nbsp;<\/td><td>IEEE 386, GB\/T 12706, DL\/T 404, GB\/T 11022<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IV. Rozsah platnosti<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Applicable voltage levels<\/strong> : 10kV\/15kV\/20kV\/24kV strednaponov\u00e9 rozvodn\u00e9 syst\u00e9my striedav\u00e9ho pr\u00fadu, kompatibiln\u00e9 s rozhraniami priechodiek americk\u00e9ho typu s maxim\u00e1lnym prev\u00e1dzkov\u00fdm nap\u00e4t\u00edm 17,5kV\/24kV.<\/li>\n\n\n\n<li><strong>Pou\u017eite\u013en\u00e9 scen\u00e1re vybavenia<\/strong> :<\/li>\n\n\n\n<li>Priechodky pre 15kV\/24kV americk\u00e9 prstencov\u00e9 hlavn\u00e9 jednotky, prefabrikovan\u00e9 rozvodne, k\u00e1blov\u00e9 odbo\u010dn\u00e9 skrine, americk\u00e9 prefabrikovan\u00e9 transform\u00e1tory a in\u00e9 distribu\u010dn\u00e9 zariadenia, umo\u017e\u0148uj\u00face pripojenie zariaden\u00ed dvoma k\u00e1blami a odbo\u010denie veden\u00ed;<\/li>\n\n\n\n<li>Pou\u017e\u00edva sa v spojen\u00ed s americk\u00fdmi lak\u0165ov\u00fdmi k\u00e1blov\u00fdmi spojkami, obj\u00edmkov\u00fdmi sedlami a izola\u010dn\u00fdmi krytkami na kon\u0161trukciu kompletn\u00fdch odpojite\u013en\u00fdch k\u00e1blov\u00fdch koncoviek a rozvetven\u00fdch rozhran\u00ed vedenia;<\/li>\n\n\n\n<li>mestsk\u00e9 rozvodn\u00e9 siete k\u00e1blov\u00fdch veden\u00ed, rozvodn\u00e9 syst\u00e9my pre priemyseln\u00e9 a bansk\u00e9 podniky a rozvodn\u00e9 zariadenia americk\u00e9ho typu pre nov\u00e9 energetick\u00e9 (fotovoltaick\u00e9\/vetern\u00e9) transformovne;<\/li>\n\n\n\n<li>\uc2e4\ub0b4\/\uc2e4\uc678 \ubc30\uc804\uc2e4, \uc9c0\ud558 \uacf5\ub3d9\uad6c, \ucf00\uc774\ube14 \ud130\ub110 \ub4f1 \ub2e4\uc591\ud55c \ud658\uacbd\uc5d0\uc11c \ubbf8\uad6d\uc2dd \uc804\ub825 \ubd84\ubc30 \uc7a5\ube44\uc758 \uc804\uba74\ubd80 \uc5f0\uacb0.<\/li>\n\n\n\n<li><strong>Function and Purpose<\/strong> : Pre dosiahnutie izola\u010dn\u00e9ho a tesniaceho spojenia priechodiek a dvoch k\u00e1blov\u00fdch pr\u00edslu\u0161enstiev v americk\u00fdch rozvodn\u00fdch zariadeniach, a na zabezpe\u010denie uzemnenia, izola\u010dnej izol\u00e1cie a funkci\u00ed odbo\u010diek vedenia, \u010d\u00edm sa poskytuje bezpe\u010dn\u00e9 a spo\u013eahliv\u00e9 rie\u0161enie predn\u00e9ho pripojenia pre americk\u00e9 strednonap\u00e4\u0165ov\u00e9 distribu\u010dn\u00e9 syst\u00e9my.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>V. Usage Conditions<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Normal operating conditions<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>V\u00fd\u0161ka: \u22642000 m<\/li>\n\n\n\n<li>Ambient temperature: -40\u2103~+90\u2103; equipment operating temperature complies with relevant standards.<\/li>\n\n\n\n<li>Relative humidity: \u2264100% (no condensation);<\/li>\n\n\n\n<li>Environmental conditions: No corrosive gases, no flammable or explosive media, no severe vibration or impact;<\/li>\n\n\n\n<li>Sp\u00f4sob in\u0161tal\u00e1cie: Kompatibiln\u00e9 so \u0161tandardn\u00fdm rozhran\u00edm obj\u00edmky americk\u00e9ho zariadenia, horizont\u00e1lna\/vertik\u00e1lna in\u0161tal\u00e1cia je prijate\u013en\u00e1 a in\u0161tala\u010dn\u00fd priestor mus\u00ed sp\u013a\u0148a\u0165 prev\u00e1dzkov\u00e9 po\u017eiadavky dvoch pr\u00edslu\u0161enstiev.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Special usage conditions (customization required)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The altitude exceeds 2000m;<\/li>\n\n\n\n<li>The ambient temperature exceeds the range of -40\u2103 to +90\u2103;<\/li>\n\n\n\n<li>Severely polluted, salt spray, and chemically corrosive environments;<\/li>\n\n\n\n<li>High vibration and high impact conditions;<\/li>\n\n\n\n<li>Nestandardn\u00e9 \u0161pecifik\u00e1cie rozhrania obj\u00edmky americk\u00e9ho zariadenia;<\/li>\n\n\n\n<li>\u0160peci\u00e1lne uzem\u0148ovacie po\u017eiadavky a vysok\u00e1 \u00farove\u0148 zne\u010distenia.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VI. In\u0161tal\u00e1cia a \u00fadr\u017eba<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Po\u017eiadavky na in\u0161tal\u00e1ciu<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pred in\u0161tal\u00e1ciou skontrolujte vzh\u013ead v\u00fdrobku, \u010di neobsahuje praskliny, po\u0161kodenia, bubliny a nepo\u0161koden\u00e9 izola\u010dn\u00e9 povrchy; skontrolujte, \u010di s\u00fa uzem\u0148ovacie svorky neporu\u0161en\u00e9 a bez hrdze, a \u010di je v\u0161etko pr\u00edslu\u0161enstvo kompletn\u00e9.<\/li>\n\n\n\n<li>Vy\u010distite povrch rozhrania obj\u00edmky zariadenia od oleja, prachu a cudz\u00edch predmetov, pri\u010dom zabezpe\u010dte, aby rozhranie bolo such\u00e9 a \u010dist\u00e9.<\/li>\n\n\n\n<li>Na vn\u00fatorn\u00fa stenu vstupn\u00e9ho konca prednej \u010dasti typu T rovnomerne naneste \u0161peci\u00e1lne silik\u00f3nov\u00e9 mazivo. <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" target=\"_blank\" rel=\"noopener\">konektor<\/a> aby sa predi\u0161lo po\u0161kodeniu izola\u010dnej vrstvy po\u010das in\u0161tal\u00e1cie.<\/li>\n\n\n\n<li>Slowly push the connector into the equipment sleeve interface to ensure it is fully in place and lock the positioning structure; connect the grounding terminal to the grounding grid, and the grounding resistance should be \u22644\u03a9.<\/li>\n\n\n\n<li>Dva v\u00fdstupn\u00e9 termin\u00e1ly s\u00fa pripojen\u00e9 k zodpovedaj\u00facim americk\u00fdm lak\u0165ov\u00fdm konektorom, izola\u010dn\u00fdm krytom a \u010fal\u0161iemu pr\u00edslu\u0161enstvu, aby sa zabezpe\u010dilo, \u017ee pr\u00edslu\u0161enstvo je spr\u00e1vne nain\u0161talovan\u00e9 a z\u00e1mok proti odpojeniu je uzamknut\u00fd.<\/li>\n\n\n\n<li>After installation, insulation resistance and power frequency withstand voltage tests are conducted. Only after passing these tests can the equipment be put into operation.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Po\u017eiadavky na \u00fadr\u017ebu<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pravidelne kontrolujte vzh\u013ead konektorov, \u010di na nich nie s\u00fa praskliny, stopy po v\u00fdboji alebo nahromaden\u00e9 ne\u010distoty, a \u010di s\u00fa uzem\u0148ovacie svorky a oba pr\u00edslu\u0161enstv\u00e1 bezpe\u010dne pripojen\u00e9 bez uvo\u013enenia.<\/li>\n\n\n\n<li>Pravidelne testujte izola\u010dn\u00fd odpor, aby ste sa uistili, \u017ee v\u00fdkon sp\u013a\u0148a po\u017eiadavky a aby ste v\u010das odhalili potenci\u00e1lne chyby.<\/li>\n\n\n\n<li>Vy\u010distite povrch konektora od prachu a ne\u010dist\u00f4t a udr\u017eujte izola\u010dn\u00fd povrch such\u00fd a \u010dist\u00fd, aby ste zabr\u00e1nili kor\u00f3zii od oleja a chemik\u00e1li\u00ed.<\/li>\n\n\n\n<li>Ak sa v konektore alebo pr\u00edslu\u0161enstve vyskytn\u00fa ak\u00e9ko\u013evek abnormality, ako s\u00fa praskliny, po\u0161kodenie, vybitie alebo prehriatie, okam\u017eite ich presta\u0148te pou\u017e\u00edva\u0165 a vyme\u0148te ich. Je pr\u00edsne zak\u00e1zan\u00e9 ich prev\u00e1dzkova\u0165, ke\u010f s\u00fa chybn\u00e9.<\/li>\n\n\n\n<li>Pri odp\u00e1jan\u00ed a prip\u00e1jan\u00ed pr\u00edslu\u0161enstva sa musia pou\u017e\u00edva\u0165 \u0161peci\u00e1lne izolovan\u00e9 n\u00e1stroje. Je pr\u00edsne zak\u00e1zan\u00e9 manipulova\u0165 s nap\u00e1jan\u00fdmi konektormi ru\u010dne. Po\u010das prev\u00e1dzky sa musia pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distrib\u00facie elektrickej energie.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VII. Upozornenia<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Produkt mus\u00ed by\u0165 in\u0161talovan\u00fd, odladen\u00fd a udr\u017eiavan\u00fd profesion\u00e1lnymi elektroin\u0161talat\u00e9rmi s kvalifik\u00e1ciou pre v\u00fdstavbu strednonap\u00e4\u0165ov\u00fdch rozvodov. Prev\u00e1dzka neprofesion\u00e1lnymi osobami je pr\u00edsne zak\u00e1zan\u00e1.<\/li>\n\n\n\n<li>Produkt mus\u00ed by\u0165 pou\u017e\u00edvan\u00fd s americk\u00fdmi typmi k\u00e1blov\u00fdch \u017e\u013eabov a k\u00e1blov\u00e9ho pr\u00edslu\u0161enstva zodpovedaj\u00facich \u0161pecifik\u00e1ci\u00ed. Je pr\u00edsne zak\u00e1zan\u00e9 pou\u017e\u00edva\u0165 rozhrania s r\u00f4znymi \u00farov\u0148ami nap\u00e4tia alebo pr\u00fadu, inak to povedie k zlyhaniu izol\u00e1cie a bezpe\u010dnostn\u00fdm nehod\u00e1m.<\/li>\n\n\n\n<li>Konektor sa nesmie rozobera\u0165 ani upravova\u0165 bez povolenia, inak zanikne z\u00e1ruka a bezpe\u010dnostn\u00e1 z\u00e1ruka. Je pr\u00edsne zak\u00e1zan\u00e9 pou\u017e\u00edva\u0165 ne\u0161pecializovan\u00e9 n\u00e1stroje na n\u00e1siln\u00fa mont\u00e1\u017e alebo demont\u00e1\u017e konektora.<\/li>\n\n\n\n<li>Je pr\u00edsne zak\u00e1zan\u00e9 prip\u00e1ja\u0165 pr\u00edslu\u0161enstvo s r\u00f4znymi \u00farov\u0148ami nap\u00e4tia alebo pr\u00fadu k dvom v\u00fdstupn\u00fdm svork\u00e1m s\u00fa\u010dasne. Musia sa pou\u017e\u00edva\u0165 v s\u00falade s parametrami syst\u00e9mu.<\/li>\n\n\n\n<li>Skladovanie by malo prebieha\u0165 v suchom, vetranom a chladnom prostred\u00ed, pri\u010dom sa treba vyhn\u00fa\u0165 priamemu slne\u010dn\u00e9mu \u017eiareniu, vysok\u00fdm teplot\u00e1m, vlhkosti a stla\u010deniu. Je pr\u00edsne zak\u00e1zan\u00e9 kontaktova\u0165 ostr\u00e9 predmety, ktor\u00e9 by mohli po\u0161kodi\u0165 izola\u010dn\u00fa vrstvu.<\/li>\n\n\n\n<li>Pri prev\u00e1dzke pr\u00edslu\u0161enstva na nap\u00e1jan\u00fdch obvodoch je nevyhnutn\u00e9 pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distrib\u00facie energie, implementova\u0165 primeran\u00e9 bezpe\u010dnostn\u00e9 opatrenia a pr\u00edsne zak\u00e1za\u0165 ak\u00e9ko\u013evek neopr\u00e1vnen\u00e9 oper\u00e1cie.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VIII. Model Description<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Model Identification<\/td><td>meaning<\/td><\/tr><tr><td>JY<\/td><td>K\u00f3d produktovej s\u00e9rie<\/td><\/tr><tr><td>QJT<\/td><td>T-typ americk\u00fd predn\u00fd konektor s\u00e9riov\u00fd k\u00f3d<\/td><\/tr><tr><td>\u25a1<\/td><td>Nap\u00e4tia (15\/24, predstavuj\u00face 15kV\/24kV)<\/td><\/tr><tr><td>600<\/td><td>Menovit\u00fd pr\u00fad, kompatibiln\u00fd s menovit\u00fdm pr\u00fadom 600A<\/td><\/tr><tr><td>T-\u043e\u0431\u0440\u0430\u0437\u043d\u044b\u0439 \u0430\u043c\u0435\u0440\u0438\u043a\u0430\u043d\u0441\u043a\u0438\u0439 \u043f\u0435\u0440\u0435\u0434\u043d\u0438\u0439 \u0440\u0430\u0437\u044a\u0435\u043c<\/td><td>T\u578b\u7f8e\u5f0f\u524d\u63a5\u5934\uff0c\u7528\u4e8e\u7f8e\u5f0f\u914d\u7535\u8bbe\u5907\u5bfc\u7ba1\u63a5\u53e3\u7684\u7535\u7f06\u8fde\u63a5\u548c\u7ebf\u8def\u5206\u652f\u9644\u4ef6\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IX. Implementation Standards and Certification<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Medzin\u00e1rodn\u00fd \u0161tandard: IEEE 386 \u201e\u0160tandard odpojite\u013en\u00fdch k\u00e1blov\u00fdch konektorov pre stredn\u00e9 nap\u00e4tie\u201c<\/li>\n\n\n\n<li>N\u00e1rodn\u00e9 normy: GB\/T 12706 \u201eVysokotlakov\u00e9 k\u00e1ble a pr\u00edslu\u0161enstvo s menovit\u00fdm nap\u00e4t\u00edm od 1 kV (Um=1,2 kV) do 35 kV (Um=40,5 kV)\u201c, GB\/T 11022 \u201eSpolo\u010dn\u00e9 technick\u00e9 po\u017eiadavky na vysokonap\u00e4\u0165ov\u00e9\u201c <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a> a kontroln\u00fdch zariaden\u00ed\u201c, DL\/T 404 \u201e3,6 kV ~ 40,5 kV AC kovom uzatv\u00e1ran\u00e9 rozv\u00e1dza\u010de a kontroln\u00e9 zariadenia\u201c;<\/li>\n\n\n\n<li>\u4ea7\u54c1\u5df2\u901a\u8fc7\u56fd\u5bb6\u9ad8\u538b\u7535\u5668\u8d28\u91cf\u76d1\u7763\u68c0\u9a8c\u4e2d\u5fc3\u578b\u5f0f\u8bd5\u9a8c\uff0c\u7b26\u5408\u56fd\u5bb6\u7535\u5668\u5b89\u5168\u6807\u51c6\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>X. Popredajn\u00fd servis<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Product warranty period: 18 months from the date of manufacture, or 12 months from the date of commissioning (whichever comes first).<\/li>\n\n\n\n<li>During the warranty period, products will be repaired or replaced free of charge if quality issues arise.<\/li>\n\n\n\n<li>We provide technical support, installation guidance, and customized services (adaptation to special specifications and working conditions).<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Document Description<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The technical parameters in this manual are based on standard operating conditions. Special operating conditions need to be customized according to actual needs. The final specifications shall be subject to the product technical agreement and type test report.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Appendix: Product outline diagram<\/strong><strong><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"335\" height=\"333\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-QJT-600-15kV-24kV-600A-T-shaped-American-front-connector-1.png\" alt=\"JY QJT-600 15kV 24kV 600A T\u578b\u7f8e\u5f0f\u524d\u63a5\u5934 \" class=\"wp-image-317\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-QJT-600-15kV-24kV-600A-T-shaped-American-front-connector-1.png 335w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-QJT-600-15kV-24kV-600A-T-shaped-American-front-connector-1-300x298.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-QJT-600-15kV-24kV-600A-T-shaped-American-front-connector-1-150x150.png 150w\" sizes=\"(max-width: 335px) 100vw, 335px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>I. Product Overview The JY QJT-600 15kV\/24kV 600A T-shaped American front connector is a standard American non-load-breaking cable accessory designed [&hellip;]<\/p>\n","protected":false},"featured_media":317,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[9],"class_list":["post-315","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-american-cable-accessories"],"acf":{"products_imagines":[316,317],"short_describe":"<p><strong> Scope of Delivery<\/strong> T-shaped American frontconnector, tespointcap,grounding wireInsulator Covering cap Conductor Cable Lug Adaptor Two-head Screw Socket wrench Silicone Lubricant, Clearing Paper Installation Instruction Sheet Quality Certificate<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/317"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/316"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/317"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=315"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}