{"id":323,"date":"2026-01-23T02:56:57","date_gmt":"2026-01-23T02:56:57","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=323"},"modified":"2026-09-16T05:51:42","modified_gmt":"2026-09-16T05:51:42","slug":"jy-zht-15kv-600-200-load-converter","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/jy-zht-15kv-600-200-load-converter\/","title":{"rendered":"JY ZHT-15kV 600\/200 \u043f\u0440\u0435\u043e\u0431\u0440\u0430\u0437\u0443\u0432\u0430\u0442\u0435\u043b \u043d\u0430 \u043d\u0430\u0442\u043e\u0432\u0430\u0440\u0432\u0430\u043d\u0435"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>I. Preh\u013ead produktu<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">JY ZHT-15kV 600\/200A prep\u00edna\u010d z\u00e1\u0165a\u017ee<\/a> (Integrovan\u00e1 priechodka pre preru\u0161enie pr\u00fadu) je pr\u00edslu\u0161enstvo na konverziu menovit\u00e9ho pr\u00fadu bez preru\u0161enia z\u00e1\u0165a\u017ee, navrhnut\u00e9 \u0161peci\u00e1lne pre strednonap\u00e4\u0165ov\u00e9 distribu\u010dn\u00e9 syst\u00e9my 15 kV (\u00farove\u0148 10 kV). Vyzna\u010duje sa plne izolovanou, plne utesnenou, dotykovo bezpe\u010dnou ku\u017ee\u013eovou kon\u0161trukciou, ktor\u00e1 umo\u017e\u0148uje kompatibilitu medzi rozhraniami s menovit\u00fdm pr\u00fadom 600 A a 200 A. Integruje funkcie vodiv\u00e9ho pripojenia, izol\u00e1cie a ochrany uzemnenia, \u0161iroko sa pou\u017e\u00edva v americk\u00fdch skri\u0148ov\u00fdch rozvodniach, prefabrikovan\u00fdch transform\u00e1torov\u00fdch staniciach, k\u00e1blov\u00fdch odbo\u010dn\u00fdch skriniach a inom vybaven\u00ed. Je to k\u013e\u00fa\u010dov\u00e1 s\u00fa\u010das\u0165 na rie\u0161enie probl\u00e9mov s kompatibilitou medzi rozhraniami s r\u00f4znym menovit\u00fdm pr\u00fadom v zariadeniach na distrib\u00faciu elektrickej energie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II. Product Characteristics<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Electrical and insulation properties<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Vyroben\u00e9 z <strong>vysoko\u010dist\u00e1 EPDM etyl\u00e9n-propyl\u00e9n-di\u00e9nov\u00fd kau\u010duk<\/strong> prostredn\u00edctvom integr\u00e1lneho vstrekovania nem\u00e1 \u017eiadne \u0161vy ani vzduchov\u00e9 medzery, vynikaj\u00faci izola\u010dn\u00fd v\u00fdkon, vydr\u017e\u00ed menovit\u00e9 nap\u00e4tie syst\u00e9mu 15 kV a kr\u00e1tkodob\u00e9 prep\u00e4tie, sp\u013a\u0148a prev\u00e1dzkov\u00e9 po\u017eiadavky maxim\u00e1lneho pracovn\u00e9ho nap\u00e4tia 17,5 kV a m\u00e1 dostato\u010dn\u00fa izola\u010dn\u00fa rezervu.<\/li>\n\n\n\n<li>V\u010faka vstavanej optimalizovanej \u0161trukt\u00fare elektrick\u00e9ho po\u013ea je elektrick\u00e9 pole rovnomerne rozlo\u017een\u00e9, \u010d\u00edm \u00fa\u010dinne potl\u00e1\u010da \u010diasto\u010dn\u00e9 v\u00fdboje. Pri dlhodobej prev\u00e1dzke nehroz\u00ed elektrick\u00e1 er\u00f3zia ani prieraz a mno\u017estvo \u010diasto\u010dn\u00fdch v\u00fdbojov je \u226410pC (pod 1,5U\u2080).<\/li>\n\n\n\n<li>Obsahuje vstavan\u00e9 meden\u00e9 vodiv\u00e9 komponenty, vynikaj\u00facu vodivos\u0165, n\u00edzky prechodov\u00fd odpor a dok\u00e1\u017ee prenies\u0165 menovit\u00fd pr\u00fad 600 A na vstupnom konci a je kompatibiln\u00fd s rozhran\u00edm 200 A na v\u00fdstupnom konci. Po\u010das dlhodobej prev\u00e1dzky generuje m\u00e1lo tepla a m\u00e1 siln\u00fa odolnos\u0165 proti kor\u00f3zii a oxid\u00e1cii.<\/li>\n\n\n\n<li>Je dod\u00e1van\u00fd so zabudovan\u00fdm \u017elto-zelen\u00fdm dvojfarebn\u00fdm uzem\u0148ovac\u00edm vodi\u010dom, ktor\u00fd umo\u017e\u0148uje spo\u013eahliv\u00e9 uzemnenie, efekt\u00edvne uvo\u013e\u0148uje pr\u00fad pri poruche a indukovan\u00e9 nap\u00e4tie a zlep\u0161uje bezpe\u010dnos\u0165 syst\u00e9mu.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Structural and Safety Features<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>V\u010faka plne izolovanej, dotykovej kon\u0161trukcii a vysokej pevnosti vonkaj\u0161ej izol\u00e1cie sa d\u00e1 vonkaj\u0161\u00ed pl\u00e1\u0161\u0165 po\u010das prev\u00e1dzky priamo dot\u00fdka\u0165 bez rizika \u00farazu elektrick\u00fdm pr\u00fadom, \u010d\u00edm sa zabezpe\u010d\u00ed bezpe\u010dnos\u0165 \u00fadr\u017ebov\u00e9ho person\u00e1lu.<\/li>\n\n\n\n<li>Z\u00fa\u017een\u00fd integrovan\u00fd dizajn obsahuje \u0161tandardn\u00e9 rozhranie 15kV 600A na jednom konci a \u0161tandardn\u00e9 rozhranie 15kV 200A na druhom, \u010do umo\u017e\u0148uje konverziu medzi dvoma r\u00f4znymi menovit\u00fdmi pr\u00fadmi. Jednoducho sa in\u0161taluje a nevy\u017eaduje \u017eiadne \u010fal\u0161ie adapt\u00e9ry.<\/li>\n\n\n\n<li>Dizajn zabra\u0148uje nespr\u00e1vnemu pripojeniu a uvo\u013eneniu. Rozmery rozhrania na oboch koncoch s\u00fa presne zladen\u00e9 s pr\u00edslu\u0161n\u00fdmi \u0161pecifikovan\u00fdmi doplnkami. M\u00f4\u017ee by\u0165 sp\u00e1rovan\u00fd iba s doplnkami zodpovedaj\u00facej triedy, \u010d\u00edm sa eliminuje riziko nespr\u00e1vneho pripojenia, uvo\u013enenia a p\u00e1du.<\/li>\n\n\n\n<li>Dod\u00e1va sa s uzem\u0148ovac\u00edm vodi\u010dom, ktor\u00fd umo\u017e\u0148uje uzemnenie zariadenia. M\u00f4\u017ee by\u0165 tie\u017e vybaven\u00fd zariaden\u00edm na zobrazenie nap\u00e4tia na monitorovanie stavu pod nap\u00e4t\u00edm a elimin\u00e1ciu rizika nespr\u00e1vnej obsluhy.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Odolnos\u0165 vo\u010di \u017eivotn\u00e9mu prostrediu a poveternostn\u00fdm vplyvom<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>M\u00e1 vynikaj\u00facu odolnos\u0165 vo\u010di poveternostn\u00fdm vplyvom a dok\u00e1\u017ee sa prisp\u00f4sobi\u0165 \u0161irok\u00e9mu rozsahu tepl\u00f4t od -40\u2103 do +90\u2103. Pru\u017enos\u0165 a izola\u010dn\u00e9 vlastnosti gumy neklesaj\u00fa pri vysok\u00fdch a n\u00edzkych teplot\u00e1ch a nehroz\u00ed riziko prasknutia alebo skrehnutia. Je vhodn\u00fd pre r\u00f4zne vonkaj\u0161ie a vn\u00fatorn\u00e9 prostredia.<\/li>\n\n\n\n<li>\u9632\u6f6e\u3001\u9632\u6c34\u3001\u9632\u6c61\u3001\u9632\u76d0\u96fe\uff0cIP67\u9632\u62a4\u7b49\u7ea7\uff0c\u53ef\u5728\u5730\u4e0b\u3001\u6f6e\u6e7f\u3001\u591a\u5c18\u7b49\u6076\u52a3\u73af\u5883\u4e0b\u957f\u671f\u7a33\u5b9a\u8fd0\u884c\uff0c\u65e0\u60e7\u96e8\u6c34\u6216\u51b7\u51dd\u8150\u8680\u3002<\/li>\n\n\n\n<li>Odoln\u00fd vo\u010di starnutiu, UV \u017eiareniu a oz\u00f3novej kor\u00f3zii, s \u017eivotnos\u0165ou viac ako 30 rokov. Nevy\u017eaduje \u017eiadnu \u00fadr\u017ebu a zni\u017euje n\u00e1sledn\u00e9 prev\u00e1dzkov\u00e9 a servisn\u00e9 n\u00e1klady.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Mechanical and Adaptation Characteristics<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>M\u00e1 vysok\u00fa mechanick\u00fa pevnos\u0165, je odoln\u00e9 vo\u010di n\u00e1razom a vibr\u00e1ci\u00e1m a odol\u00e1va mechanick\u00e9mu nam\u00e1haniu po\u010das prepravy, in\u0161tal\u00e1cie a prev\u00e1dzky bez rizika deform\u00e1cie alebo po\u0161kodenia. Jeho seizmick\u00e1 odolnos\u0165 dosahuje \u00farove\u0148 8.<\/li>\n\n\n\n<li>Je kompatibiln\u00fd s rozhraniami priechodiek zariaden\u00ed 15kV 600A a rozhraniami k\u00e1blov\u00fdch pr\u00edslu\u0161enstiev 15kV 200A, \u010do umo\u017e\u0148uje kompatibiln\u00e9 pou\u017eitie zariaden\u00ed a pr\u00edslu\u0161enstiev s r\u00f4znymi menovit\u00fdmi pr\u00fadmi a m\u00e1 siln\u00fa univerz\u00e1lnos\u0165.<\/li>\n\n\n\n<li>Rozhranie je \u0161tandardizovan\u00e9 a zodpoved\u00e1 norme IEEE 386 a relevantn\u00fdm dom\u00e1cim norm\u00e1m. Je mo\u017en\u00e9 ho prisp\u00f4sobi\u0165 rozhraniu 600A priechodiek hlavn\u00fdch americk\u00fdch distribu\u010dn\u00fdch zariaden\u00ed 15kV a pripoji\u0165 k 200A k\u00e1blov\u00fdm pr\u00edslu\u0161enstv\u00e1m.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>III. Technick\u00e9 parametre<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Parameter categories<\/td><td>project<\/td><td>Technical indicators<\/td><\/tr><tr><td>Rated electrical parameters<\/td><td>Menovit\u00e9 nap\u00e4tie syst\u00e9mu (Un)<\/td><td>10kV<\/td><\/tr><tr><td>&nbsp;<\/td><td>Rated voltage (Ue)<\/td><td>15kV (maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie 17,5kV)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Menovit\u00fd pr\u00fad (Ie)<\/td><td>600A<\/td><\/tr><tr><td>&nbsp;<\/td><td>V\u00fdstupn\u00fd pr\u00fad<\/td><td>200A<\/td><\/tr><tr><td>&nbsp;<\/td><td>Rated frequency (fn)<\/td><td>50Hz\/60Hz<\/td><\/tr><tr><td>&nbsp;<\/td><td>Power frequency withstand voltage<\/td><td>42kV\/5min (such\u00fd test), bez prierazu, bez preskoku<\/td><\/tr><tr><td>&nbsp;<\/td><td>Lightning impulse withstand voltage<\/td><td>95kV (peak value), no breakdown, no flashover<\/td><\/tr><tr><td>&nbsp;<\/td><td>Partial discharge quantity<\/td><td>\u226410pC (below 1.5U\u2080)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Rated short-circuit withstand current<\/td><td>20kA\/2s (vstup)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Contact resistance<\/td><td>\u226450\u03bc\u03a9<\/td><\/tr><tr><td>Structural and material parameters<\/td><td>Main material<\/td><td>EPDM (etyl\u00e9n-propyl\u00e9n-di\u00e9nov\u00fd kau\u010duk) (izola\u010dn\u00e1 vrstva), poc\u00ednovan\u00e1 me\u010f (vodiv\u00e9 kontakty)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Protection level<\/td><td>IP67<\/td><\/tr><tr><td>&nbsp;<\/td><td>\uc778\ud130\ud398\uc774\uc2a4 \ud45c\uc900<\/td><td>15kV 600A \ubbf8\uad6d \ud45c\uc900 \uc7a5\ube44 \ubd80\uc2f1 \uc778\ud130\ud398\uc774\uc2a4<\/td><\/tr><tr><td>&nbsp;<\/td><td>uzem\u0148ovacia met\u00f3da<\/td><td>Dod\u00e1va sa so \u017elto-zelen\u00fdm dvojfarebn\u00fdm uzem\u0148ovac\u00edm k\u00e1blom na priame uzemnenie.<\/td><\/tr><tr><td>Environmental parameters<\/td><td>Applicable altitude<\/td><td>\u22642000m (Customization available for high altitudes)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Ambient temperature<\/td><td>-40\u2103\/ +90\u2103 (operating temperature), -40\u2103\/ +70\u2103 (storage temperature)<\/td><\/tr><tr><td>&nbsp;<\/td><td>relative humidity<\/td><td>\u2264100% (bez kondenz\u00e1cie)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Seismic resistance level<\/td><td>Level 8<\/td><\/tr><tr><td>Implementation Standards<\/td><td>&nbsp;<\/td><td>IEEE 386, GB\/T 12706, DL\/T 404, GB\/T 11022<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IV. Rozsah platnosti<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Platn\u00e9 nap\u00e4tie<\/strong> 10kV striedav\u00fd strednonap\u00e4\u0165ov\u00fd distribu\u010dn\u00fd syst\u00e9m, kompatibiln\u00fd s rozhraniami priechodiek americk\u00e9ho typu, s maxim\u00e1lnym prev\u00e1dzkov\u00fdm nap\u00e4t\u00edm 17,5kV.<\/li>\n\n\n\n<li><strong>Pou\u017eite\u013en\u00e9 scen\u00e1re vybavenia<\/strong> :<\/li>\n\n\n\n<li>600A 15kV \u7f8e\u5f0f\u73af\u7f51\u67dc\u3001\u7bb1\u5f0f\u53d8\u7535\u7ad9\u3001\u7535\u7f06\u5206\u652f\u7bb1\u3001\u7f8e\u5f0f\u7bb1\u5f0f\u53d8\u538b\u5668\u7b49\u914d\u7535\u8bbe\u5907\u7684\u5957\u7ba1\u63a5\u53e3\uff0c\u53ef\u8f6c\u6362\u4e3a200A\u63a5\u53e3\u4f7f\u7528\uff1b<\/li>\n\n\n\n<li>Rie\u0161enie probl\u00e9mu kompatibility a adapt\u00e1cie medzi priechodkami zariadenia 600 A a k\u00e1blov\u00fdmi pr\u00edslu\u0161kami 200 A (koncov\u00e9 s\u00fapravy, prep\u00e4\u0165ov\u00e9 ochrany, izola\u010dn\u00e9 krytky at\u010f.);<\/li>\n\n\n\n<li>mestsk\u00e9 rozvodn\u00e9 siete k\u00e1blov\u00fdch veden\u00ed, rozvodn\u00e9 syst\u00e9my pre priemyseln\u00e9 a bansk\u00e9 podniky a rozvodn\u00e9 zariadenia americk\u00e9ho typu pre nov\u00e9 energetick\u00e9 (fotovoltaick\u00e9\/vetern\u00e9) transformovne;<\/li>\n\n\n\n<li>S\u00fa\u010dasn\u00e1 konverzia \u00farovn\u00ed pre rozhrania zariaden\u00ed v r\u00f4znych scen\u00e1roch, ako s\u00fa vn\u00fatorn\u00e9\/vonkaj\u0161ie rozvodne, podzemn\u00e9 in\u017einierske tunely a k\u00e1blov\u00e9 tunely.<\/li>\n\n\n\n<li><strong>Funkcia a aplik\u00e1cia<\/strong> : Umo\u017e\u0148uje izol\u00e1ciu a utesnenie konverzn\u00fdch spojen\u00ed medzi rozhraniami s dvoma r\u00f4znymi menovit\u00fdmi pr\u00fadmi, 600 A a 200 A, pri\u010dom z\u00e1rove\u0148 poskytuje funkcie uzemnenia, izola\u010dnej izol\u00e1cie a adapt\u00e1cie rozhrania, \u010d\u00edm pon\u00faka bezpe\u010dn\u00e9 a spo\u013eahliv\u00e9 rie\u0161enie menovit\u00e9ho pr\u00fadu kompatibiln\u00e9 s americk\u00fdmi strednonap\u00e4\u0165ov\u00fdmi distribu\u010dn\u00fdmi syst\u00e9mami.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>V. Usage Conditions<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Normal operating conditions<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>V\u00fd\u0161ka: \u22642000 m<\/li>\n\n\n\n<li>Ambient temperature: -40\u2103~+90\u2103; equipment operating temperature complies with relevant standards.<\/li>\n\n\n\n<li>Relative humidity: \u2264100% (no condensation);<\/li>\n\n\n\n<li>Environmental conditions: No corrosive gases, no flammable or explosive media, no severe vibration or impact;<\/li>\n\n\n\n<li>Met\u00f3da in\u0161tal\u00e1cie: Kompatibiln\u00e9 so \u0161tandardn\u00fdm americk\u00fdm rozhran\u00edm priechodky zariadenia 15kV 600A, prijate\u013en\u00e1 je horizont\u00e1lna\/vertik\u00e1lna in\u0161tal\u00e1cia a in\u0161tala\u010dn\u00fd priestor mus\u00ed sp\u013a\u0148a\u0165 prev\u00e1dzkov\u00e9 po\u017eiadavky pr\u00edslu\u0161enstva 200A.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Special usage conditions (customization required)<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The altitude exceeds 2000m;<\/li>\n\n\n\n<li>The ambient temperature exceeds the range of -40\u2103 to +90\u2103;<\/li>\n\n\n\n<li>Severely polluted, salt spray, and chemically corrosive environments;<\/li>\n\n\n\n<li>High vibration and high impact conditions;<\/li>\n\n\n\n<li>Nestandardn\u00e9 \u0161pecifik\u00e1cie rozhrania obj\u00edmky americk\u00e9ho zariadenia;<\/li>\n\n\n\n<li>\u0160peci\u00e1lne uzem\u0148ovacie po\u017eiadavky a vysok\u00e1 \u00farove\u0148 zne\u010distenia.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VI. In\u0161tal\u00e1cia a \u00fadr\u017eba<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Po\u017eiadavky na in\u0161tal\u00e1ciu<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pred in\u0161tal\u00e1ciou skontrolujte vzh\u013ead v\u00fdrobku, \u010di neobsahuje praskliny, po\u0161kodenia, bubliny a nepo\u0161koden\u00e9 izola\u010dn\u00e9 povrchy; skontrolujte, \u010di je uzem\u0148ovac\u00ed vodi\u010d neporu\u0161en\u00fd a bez hrdze, a \u010di je v\u0161etko pr\u00edslu\u0161enstvo kompletn\u00e9.<\/li>\n\n\n\n<li>Vy\u010distite povrch rozhrania obj\u00edmky 600A zariadenia od oleja, prachu a cudz\u00edch predmetov a zabezpe\u010dte, aby rozhranie bolo such\u00e9 a \u010dist\u00e9.<\/li>\n\n\n\n<li>Na vn\u00fatorn\u00fa stenu vstupn\u00e9ho konca meni\u010da rovnomerne naneste \u0161peci\u00e1lne silik\u00f3nov\u00e9 mazivo, aby ste predi\u0161li po\u0161kodeniu izola\u010dnej vrstvy po\u010das in\u0161tal\u00e1cie.<\/li>\n\n\n\n<li>Slowly push the adapter into the equipment sleeve interface to ensure it is fully in place and lock the positioning structure; connect the grounding lead to the grounding grid, with a grounding resistance \u22644\u03a9.<\/li>\n\n\n\n<li>Pripojte v\u00fdstupn\u00fd koniec meni\u010da k zodpovedaj\u00facemu 200A lomen\u00e9mu k\u00e1blu <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" target=\"_blank\" rel=\"noopener\">konektor<\/a>, zvodi\u010d prep\u00e4tia, izola\u010dn\u00e1 krytka a \u010fal\u0161ie pr\u00edslu\u0161enstvo, \u010d\u00edm sa zabezpe\u010d\u00ed, \u017ee pr\u00edslu\u0161enstvo je spr\u00e1vne nain\u0161talovan\u00e9 a poistka proti uvo\u013eneniu je zaisten\u00e1.<\/li>\n\n\n\n<li>After installation, insulation resistance and power frequency withstand voltage tests are conducted. Only after passing these tests can the equipment be put into operation.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Po\u017eiadavky na \u00fadr\u017ebu<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pravidelne kontrolujte vzh\u013ead adapt\u00e9ra; skontrolujte praskliny, zn\u00e1mky v\u00fdboja a nahromadenie ne\u010dist\u00f4t. Uistite sa, \u017ee uzem\u0148ovac\u00ed vodi\u010d a pripojenia na oboch koncoch s\u00fa pevn\u00e9 a nie s\u00fa uvo\u013enen\u00e9.<\/li>\n\n\n\n<li>Pravidelne testujte izola\u010dn\u00fd odpor, aby ste sa uistili, \u017ee v\u00fdkon sp\u013a\u0148a po\u017eiadavky a aby ste v\u010das odhalili potenci\u00e1lne chyby.<\/li>\n\n\n\n<li>Vy\u010distite povrch adapt\u00e9ra od prachu a ne\u010dist\u00f4t a udr\u017eujte izola\u010dn\u00fd povrch such\u00fd a \u010dist\u00fd, aby ste zabr\u00e1nili kor\u00f3zii od oleja a chemik\u00e1li\u00ed.<\/li>\n\n\n\n<li>Ak konvertor alebo jeho pr\u00edslu\u0161enstvo vykazuje abnormality, ako s\u00fa praskliny, po\u0161kodenie, vytekanie alebo prehrievanie, okam\u017eite presta\u0148te pou\u017e\u00edva\u0165 a vyme\u0148te ho. Je pr\u00edsne zak\u00e1zan\u00e9 prev\u00e1dzkova\u0165 ho, ke\u010f je po\u0161koden\u00fd.<\/li>\n\n\n\n<li>Pri odp\u00e1jan\u00ed a prip\u00e1jan\u00ed pr\u00edslu\u0161enstva sa musia pou\u017e\u00edva\u0165 \u0161peci\u00e1lne izolovan\u00e9 n\u00e1stroje. Je pr\u00edsne zak\u00e1zan\u00e9 manipulova\u0165 s nap\u00e1jan\u00fdmi rozhraniami hol\u00fdmi rukami. Po\u010das prev\u00e1dzky sa musia pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distrib\u00facie energie.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VII. Upozornenia<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Produkt mus\u00ed by\u0165 in\u0161talovan\u00fd, odladen\u00fd a udr\u017eiavan\u00fd profesion\u00e1lnymi elektroin\u0161talat\u00e9rmi s kvalifik\u00e1ciou pre v\u00fdstavbu strednonap\u00e4\u0165ov\u00fdch rozvodov. Prev\u00e1dzka neprofesion\u00e1lnymi osobami je pr\u00edsne zak\u00e1zan\u00e1.<\/li>\n\n\n\n<li>Produkt mus\u00ed by\u0165 pou\u017e\u00edvan\u00fd s obj\u00edmkami americk\u00e9ho typu a k\u00e1blov\u00fdm pr\u00edslu\u0161enstvom 200A zodpovedaj\u00facich \u0161pecifik\u00e1ci\u00ed. Je pr\u00edsne zak\u00e1zan\u00e9 pou\u017e\u00edva\u0165 rozhrania s r\u00f4znym nap\u00e4t\u00edm alebo pr\u00fadov\u00fdm hodnoten\u00edm, inak to povedie k zlyhaniu izol\u00e1cie a bezpe\u010dnostn\u00fdm nehod\u00e1m.<\/li>\n\n\n\n<li>Adapt\u00e9r sa nesmie neopr\u00e1vnene rozobera\u0165 ani upravova\u0165, inak zanikne z\u00e1ruka a bezpe\u010dnostn\u00e1 z\u00e1ruka. Je pr\u00edsne zak\u00e1zan\u00e9 pou\u017e\u00edva\u0165 ne\u0161pecializovan\u00e9 n\u00e1stroje na jeho n\u00e1siln\u00fa in\u0161tal\u00e1ciu alebo demont\u00e1\u017e.<\/li>\n\n\n\n<li>V\u00fdstupn\u00fd termin\u00e1l meni\u010da je mo\u017en\u00e9 pripoji\u0165 iba k pr\u00edslu\u0161enstvu s pr\u00fadov\u00fdm hodnoten\u00edm 200 A. Je pr\u00edsne zak\u00e1zan\u00e9 prip\u00e1ja\u0165 pr\u00edslu\u0161enstvo s pr\u00fadov\u00fdm hodnoten\u00edm 600 A, inak d\u00f4jde k po\u0161kodeniu zariadenia pre\u0165a\u017een\u00edm.<\/li>\n\n\n\n<li>Skladovanie by malo prebieha\u0165 v suchom, vetranom a chladnom prostred\u00ed, pri\u010dom sa treba vyhn\u00fa\u0165 priamemu slne\u010dn\u00e9mu \u017eiareniu, vysok\u00fdm teplot\u00e1m, vlhkosti a stla\u010deniu. Je pr\u00edsne zak\u00e1zan\u00e9 kontaktova\u0165 ostr\u00e9 predmety, ktor\u00e9 by mohli po\u0161kodi\u0165 izola\u010dn\u00fa vrstvu.<\/li>\n\n\n\n<li>Pri prev\u00e1dzke pr\u00edslu\u0161enstva na nap\u00e1jan\u00fdch obvodoch je nevyhnutn\u00e9 pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distrib\u00facie energie, implementova\u0165 primeran\u00e9 bezpe\u010dnostn\u00e9 opatrenia a pr\u00edsne zak\u00e1za\u0165 ak\u00e9ko\u013evek neopr\u00e1vnen\u00e9 oper\u00e1cie.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VIII. Model Description<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Model Identification<\/td><td>meaning<\/td><\/tr><tr><td>JY<\/td><td>K\u00f3d produktovej s\u00e9rie<\/td><\/tr><tr><td>ZHT<\/td><td>K\u00f3d s\u00e9rie prevodn\u00edka za\u0165a\u017eenia<\/td><\/tr><tr><td>15kV<\/td><td>Platn\u00e9 \u00farovne nap\u00e4tia syst\u00e9mu, maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie 17,5 kV<\/td><\/tr><tr><td>600\/200<\/td><td>Vstup je kompatibiln\u00fd s pr\u00fadov\u00fdm hodnoten\u00edm 600 A a v\u00fdstup je kompatibiln\u00fd s pr\u00fadov\u00fdm hodnoten\u00edm 200 A.<\/td><\/tr><tr><td>Integrovan\u00e1 priechodka s preru\u0161en\u00edm toku<\/td><td>Integrovan\u00fd prevodn\u00edk z\u00e1\u0165a\u017ee typu bez preru\u0161enia pr\u00fadu na prisp\u00f4sobenie a konverziu rozhran\u00ed s r\u00f4znymi menovit\u00fdmi pr\u00fadmi.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IX. Implementation Standards and Certification<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Medzin\u00e1rodn\u00fd \u0161tandard: IEEE 386 \u201e\u0160tandard odpojite\u013en\u00fdch k\u00e1blov\u00fdch konektorov pre stredn\u00e9 nap\u00e4tie\u201c<\/li>\n\n\n\n<li>N\u00e1rodn\u00e9 normy: GB\/T 12706 \u201eVysokotlakov\u00e9 k\u00e1ble a pr\u00edslu\u0161enstvo s menovit\u00fdm nap\u00e4t\u00edm od 1 kV (Um=1,2 kV) do 35 kV (Um=40,5 kV)\u201c, GB\/T 11022 \u201eSpolo\u010dn\u00e9 technick\u00e9 po\u017eiadavky na vysokonap\u00e4\u0165ov\u00e9\u201c <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear <\/a>a kontroln\u00fdch zariaden\u00ed\u201c, DL\/T 404 \u201e3,6 kV ~ 40,5 kV AC kovom uzatv\u00e1ran\u00e9 rozv\u00e1dza\u010de a kontroln\u00e9 zariadenia\u201c;<\/li>\n\n\n\n<li>\u4ea7\u54c1\u5df2\u901a\u8fc7\u56fd\u5bb6\u9ad8\u538b\u7535\u5668\u8d28\u91cf\u76d1\u7763\u68c0\u9a8c\u4e2d\u5fc3\u578b\u5f0f\u8bd5\u9a8c\uff0c\u7b26\u5408\u56fd\u5bb6\u7535\u5668\u5b89\u5168\u6807\u51c6\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>X. Popredajn\u00fd servis<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Product warranty period: 18 months from the date of manufacture, or 12 months from the date of commissioning (whichever comes first).<\/li>\n\n\n\n<li>During the warranty period, products will be repaired or replaced free of charge if quality issues arise.<\/li>\n\n\n\n<li>We provide technical support, installation guidance, and customized services (adaptation to special specifications and working conditions).<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Document Description<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The technical parameters in this manual are based on standard operating conditions. Special operating conditions need to be customized according to actual needs. The final specifications shall be subject to the product technical agreement and type test report.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Appendix: Product outline diagram<\/strong><strong><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"362\" height=\"360\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-ZHT-15kV-600-200-Integral-Deadbreak-Bushing-1.png\" alt=\"JY ZHT-15kV 600\/200 \u043f\u0440\u0435\u043e\u0431\u0440\u0430\u0437\u0443\u0432\u0430\u0442\u0435\u043b \u043d\u0430 \u043d\u0430\u0442\u043e\u0432\u0430\u0440\u0432\u0430\u043d\u0435\" class=\"wp-image-324\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-ZHT-15kV-600-200-Integral-Deadbreak-Bushing-1.png 362w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-ZHT-15kV-600-200-Integral-Deadbreak-Bushing-1-300x298.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-ZHT-15kV-600-200-Integral-Deadbreak-Bushing-1-150x150.png 150w\" sizes=\"(max-width: 362px) 100vw, 362px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>I. Product Overview The JY ZHT-15kV 600\/200A Load converter (Integral Deadbreak Bushing) is a non-load breaking current rating conversion accessory [&hellip;]<\/p>\n","protected":false},"featured_media":324,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[10],"class_list":["post-323","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-600a-cable-accessories"],"acf":{"products_imagines":[324,325],"short_describe":"<p><strong> Scope of Delivery<\/strong> Integral Deadbreak Bushing Two-head Screw Hex Wrench Clearing Paper Silicone Lubricant Covering cap Installation Instruction Sheet Quality Certificate<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/325"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/324"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/324"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=323"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}