{"id":327,"date":"2026-01-23T02:59:43","date_gmt":"2026-01-23T02:59:43","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=327"},"modified":"2026-09-15T06:26:12","modified_gmt":"2026-09-15T06:26:12","slug":"insulated-protective-cap","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/insulated-protective-cap\/","title":{"rendered":"JY JYM-600 15kV 24kV 600A Izola\u010dn\u00e1 ochrann\u00e1 \u010diapka"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>I. Preh\u013ead produktu<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">JY JYM-600 15kV 24kV 600A Izola\u010dn\u00e1 ochrann\u00e1 \u010diapka<\/a> je odpojite\u013en\u00e9 k\u00e1blov\u00e9 pr\u00edslu\u0161enstvo navrhnut\u00e9 \u0161pecificky pre strednonap\u00e4\u0165ov\u00e9 distribu\u010dn\u00e9 syst\u00e9my 15kV\/24kV (\u00farove\u0148 10kV\/20kV). Vyzna\u010duje sa plne izolovanou, plne utesnenou a dotykovo pr\u00edstupnou kon\u0161trukciou, kompatibilnou so \u0161tandardn\u00fdmi priechodkami\/rozhraniami 15kV\/24kV 600A. Poskytuje izol\u00e1ciu, tesnenie a uzem\u0148ovaciu ochranu pre ne\u010dinn\u00e9 alebo n\u00e1hradn\u00e9 k\u00e1blov\u00e9 rozhrania, \u010d\u00edm \u00fa\u010dinne zabra\u0148uje n\u00e1hodn\u00e9mu kontaktu, vlhkosti a hromadeniu ne\u010dist\u00f4t, a z\u00e1rove\u0148 uvo\u013e\u0148uje indukovan\u00e9 nap\u00e4tie. \u0160iroko pou\u017e\u00edvan\u00e9 v prstencov\u00fdch hlavn\u00fdch jednotk\u00e1ch, prefabrikovan\u00fdch transform\u00e1torovniach, k\u00e1blov\u00fdch odbo\u010dn\u00fdch skriniach a inom vybaven\u00ed, je k\u013e\u00fa\u010dov\u00fdm pr\u00edslu\u0161enstvom na zaistenie bezpe\u010dnosti rozhran\u00ed v strednonap\u00e4\u0165ov\u00fdch distribu\u010dn\u00fdch syst\u00e9moch.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II. Product Characteristics<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Izolacijske in za\u0161\u010ditne lastnosti<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Vyroben\u00e9 z <strong>vysoko\u010dist\u00e1 EPDM etyl\u00e9n-propyl\u00e9n-di\u00e9nov\u00fd kau\u010duk<\/strong> prostredn\u00edctvom integr\u00e1lneho vstrekovania nem\u00e1 \u017eiadne \u0161vy ani vzduchov\u00e9 medzery, vynikaj\u00faci izola\u010dn\u00fd v\u00fdkon, vydr\u017e\u00ed menovit\u00e9 nap\u00e4tie syst\u00e9mu 15kV\/24kV a kr\u00e1tkodob\u00e9 prep\u00e4tie, sp\u013a\u0148a prev\u00e1dzkov\u00e9 po\u017eiadavky maxim\u00e1lneho pracovn\u00e9ho nap\u00e4tia 17,5kV\/24kV a m\u00e1 dostato\u010dn\u00fa izola\u010dn\u00fa rezervu.<\/li>\n\n\n\n<li>V\u010faka vstavanej optimalizovanej \u0161trukt\u00fare elektrick\u00e9ho po\u013ea je elektrick\u00e9 pole rovnomerne rozlo\u017een\u00e9, \u010d\u00edm \u00fa\u010dinne potl\u00e1\u010da \u010diasto\u010dn\u00e9 v\u00fdboje. Pri dlhodobej prev\u00e1dzke nehroz\u00ed elektrick\u00e1 er\u00f3zia ani prieraz a mno\u017estvo \u010diasto\u010dn\u00fdch v\u00fdbojov je \u226410pC (pod 1,5U\u2080).<\/li>\n\n\n\n<li>Dod\u00e1va sa s uzem\u0148ovac\u00edm k\u00e1blom, ktor\u00fd umo\u017e\u0148uje spo\u013eahliv\u00e9 uzemnenie, efekt\u00edvne uvo\u013e\u0148uje indukovan\u00e9 nap\u00e4tie rozhrania, eliminuje riziko statickej elektriny a zais\u0165uje bezpe\u010dnos\u0165 prev\u00e1dzky a \u00fadr\u017eby.<\/li>\n\n\n\n<li>Plne utesnen\u00e1 kon\u0161trukcia a krytie IP67 zabra\u0148uj\u00fa vniknutiu vlhkosti, prachu a cudz\u00edch predmetov do rozhrania, \u010d\u00edm sa predch\u00e1dza degrad\u00e1cii izol\u00e1cie sp\u00f4sobenej hromaden\u00edm vlhkosti a ne\u010dist\u00f4t.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Structural and Safety Features<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Plne izolovan\u00e1, dotykov\u00e1 kon\u0161trukcia m\u00e1 vysok\u00fa pevnos\u0165 vonkaj\u0161ej izol\u00e1cie, \u010do umo\u017e\u0148uje priamy kontakt s vonkaj\u0161\u00edm pl\u00e1\u0161\u0165om po\u010das prev\u00e1dzky bez rizika \u00farazu elektrick\u00fdm pr\u00fadom a odstra\u0148uje bezpe\u010dnostn\u00e9 rizik\u00e1 n\u00e1hodn\u00e9ho kontaktu so \u017eiv\u00fdmi rozhraniami.<\/li>\n\n\n\n<li>\u0160tandardizovan\u00fd dizajn rozhrania je kompatibiln\u00fd so \u0161tandardn\u00fdmi obj\u00edmkami\/kolenov\u00fdmi typmi 15kV\/24kV 600A <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" target=\"_blank\" rel=\"noopener\">konektory<\/a>, \u010d\u00edm\u017e je instalace pohodln\u00e1. Lze jej zasunout p\u0159\u00edmo do rozhran\u00ed bez dal\u0161\u00edho n\u00e1\u0159ad\u00ed.<\/li>\n\n\n\n<li>M\u00e1 zabudovan\u00fa kon\u0161trukciu proti uvo\u013eneniu a prev\u00e1dzkov\u00fd kr\u00fa\u017eok, ktor\u00e9 zabra\u0148uj\u00fa uvo\u013eneniu a p\u00e1du po in\u0161tal\u00e1cii. Je tie\u017e kompatibiln\u00fd so \u0161pecializovanou izolovanou prev\u00e1dzkovou ty\u010dou, ktor\u00e1 umo\u017e\u0148uje prev\u00e1dzku pripojenia a odpojenia pod nap\u00e4t\u00edm a zlep\u0161uje pohodlie pri \u00fadr\u017ebe.<\/li>\n\n\n\n<li>Dizajn zabra\u0148uje nespr\u00e1vnemu zasunutiu v\u010faka jedine\u010dnej ve\u013ekosti rozhrania, ktor\u00fa je mo\u017en\u00e9 pou\u017ei\u0165 iba s pr\u00edslu\u0161nou \u0161pecifik\u00e1ciou rozhrania, \u010d\u00edm sa eliminuje riziko nespr\u00e1vnej in\u0161tal\u00e1cie.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. Odolnos\u0165 vo\u010di \u017eivotn\u00e9mu prostrediu a poveternostn\u00fdm vplyvom<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>M\u00e1 vynikaj\u00facu odolnos\u0165 vo\u010di poveternostn\u00fdm vplyvom a dok\u00e1\u017ee sa prisp\u00f4sobi\u0165 \u0161irok\u00e9mu rozsahu tepl\u00f4t od -40\u2103 do +90\u2103. Pru\u017enos\u0165 a izola\u010dn\u00e9 vlastnosti gumy neklesaj\u00fa pri vysok\u00fdch a n\u00edzkych teplot\u00e1ch a nehroz\u00ed riziko prasknutia alebo skrehnutia. Je vhodn\u00fd pre r\u00f4zne vonkaj\u0161ie a vn\u00fatorn\u00e9 prostredia.<\/li>\n\n\n\n<li>Je odoln\u00fd vo\u010di vlhkosti, vode, \u0161kvrn\u00e1m a so\u013enej hmle a dok\u00e1\u017ee dlho stabilne pracova\u0165 v n\u00e1ro\u010dn\u00fdch prostrediach, ako s\u00fa podzemn\u00e9, vlhk\u00e9 a pra\u0161n\u00e9 podmienky, a neboj\u00ed sa da\u017e\u010fa ani kondenz\u00e1cie.<\/li>\n\n\n\n<li>Odoln\u00fd vo\u010di starnutiu, UV \u017eiareniu a oz\u00f3novej kor\u00f3zii, s \u017eivotnos\u0165ou viac ako 30 rokov. Nevy\u017eaduje \u017eiadnu \u00fadr\u017ebu a zni\u017euje n\u00e1sledn\u00e9 prev\u00e1dzkov\u00e9 a servisn\u00e9 n\u00e1klady.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4. Mechanical and Adaptation Characteristics<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>M\u00e1 vysok\u00fa mechanick\u00fa pevnos\u0165, je odoln\u00e9 vo\u010di n\u00e1razom a vibr\u00e1ci\u00e1m a odol\u00e1va mechanick\u00e9mu nam\u00e1haniu po\u010das prepravy, in\u0161tal\u00e1cie a prev\u00e1dzky bez rizika deform\u00e1cie alebo po\u0161kodenia. Jeho seizmick\u00e1 odolnos\u0165 dosahuje \u00farove\u0148 8.<\/li>\n\n\n\n<li>Je kompatibiln\u00fd so \u0161tandardn\u00fdmi rozhraniami k\u00e1blov\u00e9ho pr\u00edslu\u0161enstva 15kV\/24kV 600A a m\u00f4\u017ee by\u0165 zamenite\u013en\u00fd s priechodkami, kolenn\u00fdmi spojkami a prep\u00e4\u0165ov\u00fdmi odpormi rovnak\u00fdch \u0161pecifik\u00e1ci\u00ed, s vysokou kompatibilitou.<\/li>\n\n\n\n<li>Rozhranie je \u0161tandardizovan\u00e9 a zodpoved\u00e1 norme IEEE 386 a relevantn\u00fdm dom\u00e1cim norm\u00e1m, pri\u010dom sa d\u00e1 prisp\u00f4sobi\u0165 rozhraniam hlavn\u00fdch distribu\u010dn\u00fdch zariaden\u00ed 15kV\/24kV.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>III. Technick\u00e9 parametre<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Parameter categories<\/td><td>project<\/td><td>Technical indicators<\/td><\/tr><tr><td>Rated electrical parameters<\/td><td>Pou\u017eite\u013en\u00e9 nap\u00e4tie syst\u00e9mu<\/td><td>10kV\/20kV (maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie 17,5kV\/24kV)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Rated current rating<\/td><td>600A (menovit\u00e9 pr\u00fadov\u00e9 za\u0165a\u017eenie rozhrania adapt\u00e9ra)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Power frequency withstand voltage<\/td><td>42kV\/5min (15kV such\u00fd test), 65kV\/5min (24kV such\u00fd test), bez prierazu, bez preskoku.<\/td><\/tr><tr><td>&nbsp;<\/td><td>Lightning impulse withstand voltage<\/td><td>95kV (15kV \u0161pi\u010dkovo) a 125kV (24kV \u0161pi\u010dkovo), bez prierazu a bez preskoku.<\/td><\/tr><tr><td>&nbsp;<\/td><td>Partial discharge quantity<\/td><td>\u226410pC (below 1.5U\u2080)<\/td><\/tr><tr><td>&nbsp;<\/td><td>\u0160pecifik\u00e1cie uzem\u0148ovacieho vodi\u010da<\/td><td>Me\u010f opleten\u00fd dr\u00f4t, \u22654mm\u00b2, d\u013a\u017eka je prisp\u00f4sobite\u013en\u00e1.<\/td><\/tr><tr><td>Structural and material parameters<\/td><td>Main material<\/td><td>EPDM (etyl\u00e9n-propyl\u00e9n-di\u00e9nov\u00fd monom\u00e9r) guma (izola\u010dn\u00e1 vrstva), poc\u00ednovan\u00e1 me\u010f (uzem\u0148ovacia svorka)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Protection level<\/td><td>IP67<\/td><\/tr><tr><td>&nbsp;<\/td><td>\uc778\ud130\ud398\uc774\uc2a4 \ud45c\uc900<\/td><td>15kV\/24kV 600A americk\u00fd \u0161tandardn\u00fd k\u00e1bel pr\u00edslu\u0161enstvo rozhranie<\/td><\/tr><tr><td>&nbsp;<\/td><td>uzem\u0148ovacia met\u00f3da<\/td><td>Dod\u00e1va sa s uzem\u0148ovac\u00edm k\u00e1blom a m\u00f4\u017ee by\u0165 priamo uzemnen\u00fd.<\/td><\/tr><tr><td>Environmental parameters<\/td><td>Applicable altitude<\/td><td>\u22642000m (Customization available for high altitudes)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Ambient temperature<\/td><td>-40\u2103\/ +90\u2103 (operating temperature), -40\u2103\/ +70\u2103 (storage temperature)<\/td><\/tr><tr><td>&nbsp;<\/td><td>relative humidity<\/td><td>\u2264100% (bez kondenz\u00e1cie)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Seismic resistance level<\/td><td>Level 8<\/td><\/tr><tr><td>Implementation Standards<\/td><td>&nbsp;<\/td><td>IEEE 386, GB\/T 12706, GB\/T 11022, DL\/T 404<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IV. Rozsah platnosti<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Applicable voltage levels<\/strong> : 10kV\/ 15kV\/20kV\/ 24kV stredn\u00e9 nap\u00e4tie pre rozvodn\u00e9 syst\u00e9my striedav\u00e9ho pr\u00fadu, kompatibiln\u00e9 s rozhraniami k\u00e1blov\u00fdch pr\u00edslu\u0161enstiev s maxim\u00e1lnym prev\u00e1dzkov\u00fdm nap\u00e4t\u00edm 17,5kV\/24kV.<\/li>\n\n\n\n<li><strong>Pou\u017eite\u013en\u00e9 scen\u00e1re vybavenia<\/strong> :<\/li>\n\n\n\n<li>15kV\/24kV\u73af\u7f51\u67dc\u3001\u9884\u88c5\u5f0f\u53d8\u7535\u7ad9\u3001\u7535\u7f06\u5206\u652f\u7bb1\u3001\u7f8e\u5f0f\u9884\u88c5\u5f0f\u53d8\u7535\u7ad9\u7b49\u914d\u7535\u8bbe\u5907\u7684\u7a7a\u8f7d\/\u5907\u7528\u63a5\u53e3\uff1b<\/li>\n\n\n\n<li>Do\u010dasne nekori\u0161teni priklju\u010dci kabelskih zavr\u0161etaka u kabelskim vodovima koriste se za izolaciju, brtvljenje i za\u0161titu uzemljenja;<\/li>\n\n\n\n<li>mestsk\u00e9 distribu\u010dn\u00e9 siete elektrickej energie, nap\u00e1jacie distribu\u010dn\u00e9 syst\u00e9my priemyseln\u00fdch a bansk\u00fdch podnikov a rozhrania nap\u00e1jania pre nov\u00e9 energetick\u00e9 (fotovoltaick\u00e9\/vetern\u00e9) zosil\u0148ovacie stanice;<\/li>\n\n\n\n<li>\uc548\uc804 \ubcf4\ud638 \uc7a5\ube44 \uc778\ud130\ud398\uc774\uc2a4 \uc2e4\ub0b4\/\uc2e4\uc678 \ubc30\uc804\uc2e4, \uc9c0\ud558 \uc720\ud2f8\ub9ac\ud2f0 \ud130\ub110, \ucf00\uc774\ube14 \ud130\ub110 \ub4f1 \ub2e4\uc591\ud55c \uc2dc\ub098\ub9ac\uc624<\/li>\n\n\n\n<li><strong>Function and Purpose<\/strong> : 15kV\/24kV 600A \ucf00\uc774\ube14 \uc561\uc138\uc11c\ub9ac \uc778\ud130\ud398\uc774\uc2a4\uc758 \uc808\uc5f0, \ubc00\ubd09 \ubc0f \uc811\uc9c0 \ubcf4\ud638\ub97c \uc81c\uacf5\ud558\uace0, \uc6b0\ubc1c\uc801\uc778 \uc811\ucd09, \uc2b5\uae30 \ubc0f \uba3c\uc9c0 \ucd95\uc801\uc744 \ubc29\uc9c0\ud558\uba70, \uc720\ub3c4 \uc804\uc555\uc744 \uc81c\uac70\ud558\uace0, \ubc30\uc804 \uc2dc\uc2a4\ud15c \uc778\ud130\ud398\uc774\uc2a4\uc758 \uc548\uc804\uc744 \ubcf4\uc7a5\ud569\ub2c8\ub2e4.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>V. Usage Conditions<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Normal operating conditions<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>V\u00fd\u0161ka: \u22642000 m<\/li>\n\n\n\n<li>Ambient temperature: -40\u2103~+90\u2103; equipment operating temperature complies with relevant standards.<\/li>\n\n\n\n<li>Relative humidity: \u2264100% (no condensation);<\/li>\n\n\n\n<li>Environmental conditions: No corrosive gases, no flammable or explosive media, no severe vibration or impact;<\/li>\n\n\n\n<li>Sp\u00f4sob in\u0161tal\u00e1cie: Kompatibiln\u00e9 so \u0161tandardn\u00fdm rozhran\u00edm 15kV\/24kV 600A, prijate\u013en\u00e1 je horizont\u00e1lna alebo vertik\u00e1lna in\u0161tal\u00e1cia a priestor na in\u0161tal\u00e1ciu mus\u00ed sp\u013a\u0148a\u0165 prev\u00e1dzkov\u00e9 po\u017eiadavky.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Special usage conditions (customization required)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The altitude exceeds 2000m;<\/li>\n\n\n\n<li>The ambient temperature exceeds the range of -40\u2103 to +90\u2103;<\/li>\n\n\n\n<li>Severely polluted, salt spray, and chemically corrosive environments;<\/li>\n\n\n\n<li>High vibration and high impact conditions;<\/li>\n\n\n\n<li>Nestandardn\u00e9 \u0161pecifik\u00e1cie rozhrania a \u0161peci\u00e1lne po\u017eiadavky na uzemnenie.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VI. In\u0161tal\u00e1cia a \u00fadr\u017eba<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Po\u017eiadavky na in\u0161tal\u00e1ciu<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pred in\u0161tal\u00e1ciou skontrolujte vzh\u013ead v\u00fdrobku, \u010di neobsahuje praskliny, po\u0161kodenia, bubliny a nepo\u0161koden\u00e9 izola\u010dn\u00e9 povrchy; skontrolujte, \u010di je uzem\u0148ovac\u00ed vodi\u010d neporu\u0161en\u00fd a bez hrdze, a \u010di je v\u0161etko pr\u00edslu\u0161enstvo kompletn\u00e9.<\/li>\n\n\n\n<li>Vy\u010distite povrch rozhrania, ktor\u00e9 sa m\u00e1 nain\u0161talova\u0165, odstr\u00e1\u0148te olej, prach a cudzie predmety a uistite sa, \u017ee rozhranie je such\u00e9 a \u010dist\u00e9.<\/li>\n\n\n\n<li>Na vn\u00fatorn\u00fa stenu rozhrania izola\u010dn\u00e9ho uz\u00e1veru rovnomerne naneste \u0161peci\u00e1lne silik\u00f3nov\u00e9 mazivo, aby ste predi\u0161li po\u0161kodeniu izola\u010dnej vrstvy po\u010das in\u0161tal\u00e1cie.<\/li>\n\n\n\n<li>Slowly push the insulating cap into the interface to ensure it is fully in place and lock the anti-detachment structure; connect the grounding lead to the grounding grid, and the grounding resistance should be \u22644\u03a9.<\/li>\n\n\n\n<li>Po in\u0161tal\u00e1cii skontrolujte, \u010di je izola\u010dn\u00e1 krytka bezpe\u010dne nasaden\u00e1, bez uvo\u013enenia alebo naklonenia, a \u010di je uzem\u0148ovacie pripojenie spo\u013eahliv\u00e9.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Po\u017eiadavky na \u00fadr\u017ebu<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pravidelne kontrolujte vzh\u013ead izola\u010dnej \u010diapo\u010dky; skontrolujte praskliny, zn\u00e1mky v\u00fdboja a nahromadenie ne\u010dist\u00f4t a uistite sa, \u017ee uzem\u0148ovac\u00ed vodi\u010d je bezpe\u010dne pripojen\u00fd bez uvo\u013enenia.<\/li>\n\n\n\n<li>Pravidelne testujte izola\u010dn\u00fd odpor, aby ste sa uistili, \u017ee v\u00fdkon sp\u013a\u0148a po\u017eiadavky a aby ste v\u010das odhalili potenci\u00e1lne chyby.<\/li>\n\n\n\n<li>Vy\u010distite povrch izola\u010dnej \u010diapo\u010dky, aby ste odstr\u00e1nili nahromaden\u00fd prach a ne\u010distoty, udr\u017eujte izola\u010dn\u00fd povrch such\u00fd a \u010dist\u00fd a zabr\u00e1\u0148te kor\u00f3zii od oleja a chemik\u00e1li\u00ed.<\/li>\n\n\n\n<li>Ak izola\u010dn\u00fd uz\u00e1ver vykazuje ak\u00e9ko\u013evek abnormality, ako s\u00fa praskliny, po\u0161kodenia alebo uvo\u013enenie, mus\u00ed sa okam\u017eite zastavi\u0165 a vymeni\u0165. Prev\u00e1dzka s chybami je pr\u00edsne zak\u00e1zan\u00e1.<\/li>\n\n\n\n<li>Na vkladanie a vyberanie izola\u010dn\u00fdch krytiek sa musia pou\u017e\u00edva\u0165 \u0161peci\u00e1lne izolovan\u00e9 n\u00e1stroje. Je pr\u00edsne zak\u00e1zan\u00e9 manipulova\u0165 s nap\u00e1jan\u00fdmi rozhraniami hol\u00fdmi rukami. Po\u010das prev\u00e1dzky je potrebn\u00e9 pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distrib\u00facie elektrickej energie.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VII. Upozornenia<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Produkt mus\u00ed by\u0165 in\u0161talovan\u00fd, odladen\u00fd a udr\u017eiavan\u00fd profesion\u00e1lnymi elektroin\u0161talat\u00e9rmi s kvalifik\u00e1ciou pre v\u00fdstavbu strednonap\u00e4\u0165ov\u00fdch rozvodov. Prev\u00e1dzka neprofesion\u00e1lnymi osobami je pr\u00edsne zak\u00e1zan\u00e1.<\/li>\n\n\n\n<li>Produkt mus\u00ed by\u0165 pou\u017e\u00edvan\u00fd s pr\u00edslu\u0161n\u00fdmi \u0161pecifik\u00e1ciami rozhrania. Je pr\u00edsne zak\u00e1zan\u00e9 pou\u017e\u00edva\u0165 rozhrania s r\u00f4znymi \u00farov\u0148ami nap\u00e4tia alebo pr\u00fadu, inak to povedie k zlyhaniu izol\u00e1cie a bezpe\u010dnostn\u00fdm nehod\u00e1m.<\/li>\n\n\n\n<li>Izola\u010dn\u00e9 krytky sa nesm\u00fa bez povolenia rozobera\u0165 ani upravova\u0165, inak zanikne z\u00e1ruka a bezpe\u010dnostn\u00e1 z\u00e1ruka. Je pr\u00edsne zak\u00e1zan\u00e9 pou\u017e\u00edva\u0165 na ich n\u00e1siln\u00fa in\u0161tal\u00e1ciu alebo demont\u00e1\u017e ne\u0161pecializovan\u00e9 n\u00e1stroje.<\/li>\n\n\n\n<li>The grounding of the insulating cap must be reliable, with a grounding resistance of \u22644\u03a9; otherwise, the induced voltage cannot be effectively released, posing a safety hazard.<\/li>\n\n\n\n<li>Skladovanie by malo prebieha\u0165 v suchom, vetranom a chladnom prostred\u00ed, pri\u010dom sa treba vyhn\u00fa\u0165 priamemu slne\u010dn\u00e9mu \u017eiareniu, vysok\u00fdm teplot\u00e1m, vlhkosti a stla\u010deniu. Je pr\u00edsne zak\u00e1zan\u00e9 kontaktova\u0165 ostr\u00e9 predmety, ktor\u00e9 by mohli po\u0161kodi\u0165 izola\u010dn\u00fa vrstvu.<\/li>\n\n\n\n<li>Pri nasadzovan\u00ed alebo odp\u00e1jan\u00ed izola\u010dn\u00fdch krytiek po\u010das prev\u00e1dzky pod nap\u00e4t\u00edm je nevyhnutn\u00e9 pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distrib\u00facie elektrickej energie, prija\u0165 primeran\u00e9 bezpe\u010dnostn\u00e9 opatrenia a pr\u00edsne zak\u00e1za\u0165 ak\u00e9ko\u013evek neopr\u00e1vnen\u00e9 oper\u00e1cie.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VIII. Model Description<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Model Identification<\/td><td>meaning<\/td><\/tr><tr><td>JY<\/td><td>K\u00f3d produktovej s\u00e9rie<\/td><\/tr><tr><td>JYM<\/td><td>K\u00f3d s\u00e9rie izola\u010dnej \u010diapky<\/td><\/tr><tr><td>\u25a1<\/td><td>Nap\u00e4tia (15\/24, predstavuj\u00face 15kV\/24kV)<\/td><\/tr><tr><td>600<\/td><td>Pr\u00fadov\u00e9 hodnotenie adapt\u00e9ra<\/td><\/tr><tr><td>Izolovan\u00e1 ochrann\u00e1 \u010diapka<\/td><td>Izola\u010dn\u00e1 ochrann\u00e1 krytka, \u0161tandardn\u00e1 ochrann\u00e1 s\u00fa\u010diastka rozhrania s uzem\u0148ovac\u00edm vodi\u010dom<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IX. Implementation Standards and Certification<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Medzin\u00e1rodn\u00fd \u0161tandard: IEEE 386 \u201eOdpojite\u013en\u00fd k\u00e1bel pre stredn\u00e9 nap\u00e4tie <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" target=\"_blank\" rel=\"noopener\">Konektor<\/a> \ud45c\uc900<\/li>\n\n\n\n<li>N\u00e1rodn\u00e9 normy: GB\/T 12706 \u201eVysokotlakov\u00e9 k\u00e1ble a pr\u00edslu\u0161enstvo s menovit\u00fdm nap\u00e4t\u00edm od 1 kV (Um=1,2 kV) do 35 kV (Um=40,5 kV)\u201c, GB\/T 11022 \u201eSpolo\u010dn\u00e9 technick\u00e9 po\u017eiadavky na vysokonap\u00e4\u0165ov\u00e9\u201c <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a> a kontroln\u00fdch zariaden\u00ed\u201c, DL\/T 404 \u201e3,6 kV ~ 40,5 kV AC kovom uzatv\u00e1ran\u00e9 rozv\u00e1dza\u010de a kontroln\u00e9 zariadenia\u201c;<\/li>\n\n\n\n<li>\u4ea7\u54c1\u5df2\u901a\u8fc7\u56fd\u5bb6\u9ad8\u538b\u7535\u5668\u8d28\u91cf\u76d1\u7763\u68c0\u9a8c\u4e2d\u5fc3\u578b\u5f0f\u8bd5\u9a8c\uff0c\u7b26\u5408\u56fd\u5bb6\u7535\u5668\u5b89\u5168\u6807\u51c6\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>X. Popredajn\u00fd servis<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Product warranty period: 18 months from the date of manufacture, or 12 months from the date of commissioning (whichever comes first).<\/li>\n\n\n\n<li>During the warranty period, products will be repaired or replaced free of charge if quality issues arise.<\/li>\n\n\n\n<li>We provide technical support, installation guidance, and customized services (adaptation to special specifications and working conditions).<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Document Description<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The technical parameters in this manual are based on standard operating conditions. Special operating conditions need to be customized according to actual needs. The final specifications shall be subject to the product technical agreement and type test report.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Appendix: Product outline diagram<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>I. Product Overview JY JYM-600 15kV 24kV 600A Insulated Protective Cap is a detachable cable accessory designed specifically for 15kV\/24kV [&hellip;]<\/p>\n","protected":false},"featured_media":329,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[9],"class_list":["post-327","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-american-cable-accessories"],"acf":{"products_imagines":[329,330,331],"short_describe":"<p><strong>Scope of Delivery<\/strong> Insulated protective cap Clearing paper Silicone lubricant Installation instruction sheet Quality certificate<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/331"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/330"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/329"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/329"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=327"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}