{"id":376,"date":"2026-01-23T05:14:26","date_gmt":"2026-01-23T05:14:26","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=376"},"modified":"2026-09-15T05:25:36","modified_gmt":"2026-09-15T05:25:36","slug":"jy-ekl-4-panel-type-fault-indicator","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/jy-ekl-4-panel-type-fault-indicator\/","title":{"rendered":"JY EKL-4 Panelov\u00fd typ indik\u00e1tora por\u00fach"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>I. Preh\u013ead produktu<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">Indikator poruchy typu panelu JY EKL-4 (SJWL-EKL-4)<\/a> je centralizovan\u00e9 monitorovacie zariadenie por\u00fach navrhnut\u00e9 \u0161peci\u00e1lne pre distribu\u010dn\u00e9 syst\u00e9my stredn\u00e9ho nap\u00e4tia 10 kV. Sklad\u00e1 sa z panelov\u00e9ho hostite\u013ea, senzorov por\u00fach vedenia a spojovac\u00edch vodi\u010dov. M\u00f4\u017ee by\u0165 in\u0161talovan\u00fd na paneli zariaden\u00ed, ako s\u00fa prstencov\u00e9 hlavn\u00e9 jednotky, prefabrikovan\u00e9 rozvodne a k\u00e1blov\u00e9 odbo\u010dn\u00e9 skrine, na monitorovanie skratov\u00fdch a zemn\u00fdch por\u00fach viacer\u00fdch k\u00e1blov\u00fdch veden\u00ed v re\u00e1lnom \u010dase. Ke\u010f d\u00f4jde k poruche, chybn\u00e9 vedenie sa intuit\u00edvne zobraz\u00ed prostredn\u00edctvom LED indik\u00e1torov na paneli. M\u00e1 tie\u017e roz\u0161\u00edren\u00e9 funkcie, ako je pam\u00e4\u0165 por\u00fach a dia\u013ekov\u00e1 komunik\u00e1cia. Je to k\u013e\u00fa\u010dov\u00e9 zariadenie na zlep\u0161enie efekt\u00edvnosti diagnostiky por\u00fach a \u00farovne inteligentnej prev\u00e1dzky a \u00fadr\u017eby distribu\u010dn\u00fdch syst\u00e9mov.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>II. Product Characteristics<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. V\u00fdkon detekcie a indik\u00e1cie por\u00fach<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Viacriadkov\u00e9 centralizovan\u00e9 monitorovanie<\/strong> : \ub3d9\uc2dc\uc5d0 3\uac1c\uc758 \ucf00\uc774\ube14 \ub77c\uc778\uc758 \ub2e8\ub77d \ubc0f \uc9c0\ub77d \uace0\uc7a5\uc744 \uac10\uc2dc\ud560 \uc218 \uc788\uc73c\uba70, 3\uc0c1 4\uc120\uc2dd \ub610\ub294 3\uc0c1 3\uc120\uc2dd \ubc30\uc804 \uc2dc\uc2a4\ud15c\uacfc \ud638\ud658\ub429\ub2c8\ub2e4. \ub192\uc740 \uace0\uc7a5 \uc2dd\ubcc4 \uc815\ud655\ub3c4\uc640 \ub0ae\uc740 \uc624\uacbd\ubcf4\uc728\uc744 \uac00\uc9c0\uace0 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n\n\n\n<li><strong>Detekcia dvoch ch\u00fdb<\/strong> Extern\u00fd sn\u00edma\u010d por\u00fach deteguje n\u00e1hle zmeny pr\u00fadu skratu a pr\u00fadu zvodov\u00e9ho. Indik\u00e1ciu m\u00f4\u017eu spusti\u0165 skraty aj zemn\u00e9 poruchy, pri\u010dom typ poruchy je mo\u017en\u00e9 rozl\u00ed\u0161i\u0165 a zobrazi\u0165.<\/li>\n\n\n\n<li><strong>Intuit\u00edvna a centralizovan\u00e1 indik\u00e1cia<\/strong> Hlavn\u00fd panel pou\u017e\u00edva LED kontrolky na zobrazenie stavu poruchy ka\u017edej linky. Ke\u010f d\u00f4jde k poruche, pr\u00edslu\u0161n\u00e1 kontrolka linky zostane svieti\u0165, \u010do umo\u017e\u0148uje pracovn\u00edkom \u00fadr\u017eby r\u00fdchlo lokalizova\u0165 chybn\u00fa linku na paneli zariadenia.<\/li>\n\n\n\n<li><strong>Pam\u00e4\u0165 ch\u00fdb a reset<\/strong> Po odstr\u00e1nen\u00ed poruchy vedenia sa indik\u00e1tor m\u00f4\u017ee automaticky resetova\u0165, alebo sa pam\u00e4\u0165 por\u00fach vyma\u017ee manu\u00e1lnym stla\u010den\u00edm tla\u010didla. Z\u00e1znamy o poruch\u00e1ch sa daj\u00fa dlhodobo uchov\u00e1va\u0165, \u010do je vhodn\u00e9 na sledovanie por\u00fach.<\/li>\n\n\n\n<li><strong>Roz\u0161\u00edren\u00e9 komunika\u010dn\u00e9 funkcie<\/strong> : Volite\u013en\u00e9 komunika\u010dn\u00e9 rozhranie RS485\/Modbus je mo\u017en\u00e9 prida\u0165 na nahr\u00e1vanie inform\u00e1ci\u00ed o poruch\u00e1ch do backendov\u00e9ho monitorovacieho syst\u00e9mu, realiz\u00e1ciu dia\u013ekov\u00e9ho monitorovania a alarmu por\u00fach a zlep\u0161enie \u00farovne inteligentnej prev\u00e1dzky a \u00fadr\u017eby.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Kon\u0161truk\u010dn\u00e9 a in\u0161tala\u010dn\u00e9 charakteristiky<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Dvojdielny modul\u00e1rny dizajn<\/strong> : Sklad\u00e1 sa z panelov\u00e9ho hostite\u013ea, extern\u00fdch senzorov por\u00fach a prepojovac\u00edch k\u00e1blov. Senzory sa nacvak\u00e1vaj\u00fa na k\u00e1blov\u00fa linku a hostite\u013e sa in\u0161taluje na panel zariadenia. In\u0161tal\u00e1cia je pohodln\u00e1 a d\u00e1 sa vykona\u0165 bez preru\u0161enia nap\u00e1jania.<\/li>\n\n\n\n<li><strong>Plne utesnen\u00e1 kon\u0161trukcia sn\u00edma\u010da<\/strong> : Kryt sn\u00edma\u010da por\u00fach je vyroben\u00fd z vysokopevnostn\u00e9ho technick\u00e9ho plastu s kryt\u00edm IP67, v\u010faka \u010domu je odoln\u00fd vo\u010di vlhkosti, vode, ne\u010distot\u00e1m a so\u013enej hmle a je schopn\u00fd dlhodobej stabilnej prev\u00e1dzky v n\u00e1ro\u010dn\u00fdch prostrediach, ako s\u00fa vonkaj\u0161ie priestory, vlhkos\u0165 a prach.<\/li>\n\n\n\n<li><strong>N\u00edzka spotreba energie a dlh\u00e1 \u017eivotnos\u0165<\/strong> Panelov\u00fd hostite\u013e pou\u017e\u00edva n\u00edzkoenergetick\u00e9 elektronick\u00e9 komponenty a m\u00f4\u017ee by\u0165 nap\u00e1jan\u00fd intern\u00fdm nap\u00e1jac\u00edm zdrojom alebo vstavanou bat\u00e9riou. Senzor m\u00e1 pas\u00edvny dizajn a \u017eivotnos\u0165 viac ako 10 rokov, nevy\u017eaduje \u010dast\u00fa \u00fadr\u017ebu.<\/li>\n\n\n\n<li><strong>Siln\u00e1 odolnos\u0165 proti ru\u0161eniu<\/strong> Vstavan\u00fd obvod proti ru\u0161eniu dok\u00e1\u017ee \u00fa\u010dinne odol\u00e1va\u0165 elektrick\u00e9mu a elektromagnetick\u00e9mu ru\u0161eniu indukovan\u00e9mu na veden\u00ed, predch\u00e1dza\u0165 poruch\u00e1m, zlep\u0161ova\u0165 spo\u013eahlivos\u0165 detekcie por\u00fach a je vhodn\u00fd pre prostredia so siln\u00fdm elektromagnetick\u00fdm ru\u0161en\u00edm, ako s\u00fa prstencov\u00e9 skrine a skri\u0148ov\u00e9 transform\u00e1torov\u00e9 stanice.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. Odolnos\u0165 vo\u010di \u017eivotn\u00e9mu prostrediu a poveternostn\u00fdm vplyvom<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Siln\u00e1 \u0161irok\u00e1 teplotn\u00e1 prisp\u00f4sobivos\u0165<\/strong> : Dok\u00e1\u017ee sa prisp\u00f4sobi\u0165 \u0161irok\u00e9mu teplotn\u00e9mu rozsahu od -40\u2103 do +85\u2103. Elektronick\u00e9 komponenty s\u00fa stabiln\u00e9 pri vysok\u00fdch a n\u00edzkych teplot\u00e1ch, bez rizika zlyhania alebo poruchy. Je vhodn\u00fd pre r\u00f4zne vonkaj\u0161ie a vn\u00fatorn\u00e9 scen\u00e1re.<\/li>\n\n\n\n<li><strong>Vynikaj\u00faca odolnos\u0165 vo\u010di vlhkosti a ne\u010distot\u00e1m<\/strong> Senzor m\u00e1 plne utesnen\u00fa kon\u0161trukciu krytu, ktor\u00e1 zabra\u0148uje vniknutiu vlhkosti a prachu; panelov\u00fd hostite\u013e m\u00e1 prachotesn\u00fd dizajn, ktor\u00fd je vhodn\u00fd do pra\u0161n\u00e9ho prostredia vo vn\u00fatri rozvodn\u00fdch zariaden\u00ed.<\/li>\n\n\n\n<li><strong>Vynikaj\u00faci \u00fa\u010dinok proti starnutiu<\/strong> Vonkaj\u0161\u00ed pl\u00e1\u0161\u0165 je vyroben\u00fd z technick\u00fdch plastov odoln\u00fdch vo\u010di UV \u017eiareniu a starnutiu, ktor\u00e9 vydr\u017eia dlhodob\u00e9 vonkaj\u0161ie pou\u017eitie bez praskania alebo krehnutia. Vn\u00fatorn\u00e9 komponenty zariadenia maj\u00fa vynikaj\u00facu odolnos\u0165 proti starnutiu a \u017eivotnos\u0165 viac ako 10 rokov.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>III. Technick\u00e9 parametre<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Parameter categories<\/td><td>project<\/td><td>Technical indicators<\/td><\/tr><tr><td>Platn\u00e9 parametre veden\u00ed<\/td><td>Applicable system voltage (Un)<\/td><td>10kV<\/td><\/tr><tr><td>&nbsp;<\/td><td>Pou\u017eite\u013en\u00fd vonkaj\u0161\u00ed priemer k\u00e1bla<\/td><td>16~30mm (in\u00e9 ve\u013ekosti je mo\u017en\u00e9 prisp\u00f4sobi\u0165)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Pou\u017eite\u013en\u00fd pr\u00fad v obvode<\/td><td>10~630A<\/td><\/tr><tr><td>Parametre za zaznavanje napak<\/td><td>Po\u010det monitorovan\u00fdch riadkov<\/td><td>Trasa 3<\/td><\/tr><tr><td>&nbsp;<\/td><td>Skratov\u00fd prev\u00e1dzkov\u00fd pr\u00fad<\/td><td>200~1000A (nastavite\u013en\u00e9)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Pr\u00fad pri zemnom skrate<\/td><td>10~100A (\uc870\uc808 \uac00\ub2a5)<\/td><\/tr><tr><td>&nbsp;<\/td><td>\u010cas odozvy pri poruche<\/td><td>\u22640.1s<\/td><\/tr><tr><td>&nbsp;<\/td><td>Met\u00f3da resetovania<\/td><td>Automatick\u00e9 zresetovanie \/ Manu\u00e1lne zresetovanie<\/td><\/tr><tr><td>&nbsp;<\/td><td>Met\u00f3da in\u0161trukcie<\/td><td>Centr\u00e1lne zobrazenie kontroliek LED na paneli<\/td><\/tr><tr><td>Elektrick\u00e9 parametre<\/td><td>pracovn\u00fd nap\u00e1jac\u00ed zdroj<\/td><td>AC\/DC 220V (nap\u00e1jan\u00e9 zo sie\u0165ovej z\u00e1suvky zariadenia) \/ Nap\u00e1jan\u00e9 vstavanou l\u00edtiovou bat\u00e9riou<\/td><\/tr><tr><td>&nbsp;<\/td><td>Statick\u00e1 spotreba energie<\/td><td>\u22641W<\/td><\/tr><tr><td>&nbsp;<\/td><td>Komunika\u010dn\u00e9 rozhranie<\/td><td>Volite\u013en\u00e9 RS485\/Modbus (roz\u0161\u00edren\u00e1 funk\u010dnos\u0165)<\/td><\/tr><tr><td>\u0160trukt\u00farne a environment\u00e1lne parametre<\/td><td>Main material<\/td><td>Vysokopevnostn\u00e9 technick\u00e9 plasty (kryt sn\u00edma\u010da\/hlavnej jednotky), kov (pracky)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Protection level<\/td><td>Senzor IP67, hostite\u013e IP40<\/td><\/tr><tr><td>&nbsp;<\/td><td>Applicable altitude<\/td><td>\u22642000m (Customization available for high altitudes)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Ambient temperature<\/td><td>-40\u2103\/ +85\u2103 (prev\u00e1dzkov\u00e1 teplota), -40\u2103\/ +70\u2103 (skladovacia teplota)<\/td><\/tr><tr><td>&nbsp;<\/td><td>relative humidity<\/td><td>\u2264100% (bez kondenz\u00e1cie)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Seismic resistance level<\/td><td>Level 8<\/td><\/tr><tr><td>Implementation Standards<\/td><td>&nbsp;<\/td><td>DL\/T 1073 \u201c\u914d\u7535\u7f51\u6545\u969c\u6307\u793a\u5668\u6280\u672f\u6761\u4ef6\u201d, GB\/T 17626 \u201c\u7535\u78c1\u517c\u5bb9 \u8bd5\u9a8c\u548c\u6d4b\u91cf\u6280\u672f\u201d, and GB\/T 11022 \u201c\u9ad8\u538b\u5f00\u5173\u8bbe\u5907\u548c\u63a7\u5236\u8bbe\u5907. \u7b2c2\u90e8\u5206: \u5171\u540c\u6280\u672f\u8981\u6c42\u201d <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">Rozvodn\u00e9 zariadenia<\/a> a riadiace zariadenia<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IV. Rozsah platnosti<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Platn\u00e9 nap\u00e4tie<\/strong> 10kV AC strednonap\u00e4\u0165ov\u00fd distribu\u010dn\u00fd syst\u00e9m, kompatibiln\u00fd s k\u00e1blov\u00fdmi vedeniami s maxim\u00e1lnym prev\u00e1dzkov\u00fdm nap\u00e4t\u00edm 12kV.<\/li>\n\n\n\n<li><strong>Pou\u017eite\u013en\u00e9 scen\u00e1re vybavenia<\/strong> :<\/li>\n\n\n\n<li>Na paneloch rozvodn\u00fdch zariaden\u00ed, ako s\u00fa 10kV vn\u00fatorn\u00e9 jednotky, prefabrikovan\u00e9 transformovne, k\u00e1blov\u00e9 odbo\u010dn\u00e9 skrine a prefabrikovan\u00e9 transformovne americk\u00e9ho typu, sa centr\u00e1lne monitoruj\u00fa skraty a zemn\u00e9 poruchy viacer\u00fdch k\u00e1blov\u00fdch veden\u00ed.<\/li>\n\n\n\n<li>Mestsk\u00e9 rozvodn\u00e9 k\u00e1ble, syst\u00e9my distrib\u00facie energie pre priemyseln\u00e9 a bansk\u00e9 podniky a rozvodn\u00e9 vedenia pre nov\u00e9 energetick\u00e9 (fotovoltaick\u00e9\/vetern\u00e9) rozvodne;<\/li>\n\n\n\n<li>\uc911\uc559 \uc9d1\uc911\uc2dd \uc804\ub825 \ubd84\ubc30 \uc7a5\ube44 \uace0\uc7a5 \ubaa8\ub2c8\ud130\ub9c1 (\uc2e4\ub0b4 \uc804\ub825 \ubd84\ubc30\uc2e4, \uc9c0\ud558 \uc720\ud2f8\ub9ac\ud2f0 \ud130\ub110, \ucf00\uc774\ube14 \ud130\ub110 \ub4f1 \ub2e4\uc591\ud55c \uc2dc\ub098\ub9ac\uc624 \ud3ec\ud568)<\/li>\n\n\n\n<li><strong>Function and Purpose<\/strong> : \uc911\uc559\uc5d0\uc11c 10kV \ubc30\uc804 \uc124\ube44\uc758 \ub2e4\uc911 \ucf00\uc774\ube14 \ub77c\uc778\uc5d0\uc11c \ub2e8\ub77d \ubc0f \uc9c0\ub77d \uc704\uce58\ub97c \ubaa8\ub2c8\ud130\ub9c1\ud558\uace0 \ud45c\uc2dc\ud558\uc5ec \uc720\uc9c0\ubcf4\uc218 \uc778\ub825\uc774 \uc2e0\uc18d\ud558\uac8c \uace0\uc7a5\uc744 \uc9c4\ub2e8\ud558\uace0 \uace0\uc7a5 \ucc98\ub9ac \uc2dc\uac04\uc744 \ub2e8\ucd95\ud558\uba70 \ubc30\uc804 \uc2dc\uc2a4\ud15c\uc758 \uc804\ub825 \uacf5\uae09 \uc2e0\ub8b0\ub3c4\ub97c \ud5a5\uc0c1\uc2dc\ud0a4\ub294 \ub370 \ub3c4\uc6c0\uc744 \uc90d\ub2c8\ub2e4. \ud655\uc7a5\ub41c \ud1b5\uc2e0 \uae30\ub2a5\uc740 \uc6d0\uaca9 \uace0\uc7a5 \ubaa8\ub2c8\ud130\ub9c1 \ubc0f \uacbd\ubcf4\ub97c \uc2e4\ud604\ud558\uace0 \ubc30\uc804 \uc2dc\uc2a4\ud15c\uc758 \uc9c0\ub2a5\ud615 \uc6b4\uc601 \ubc0f \uc720\uc9c0\ubcf4\uc218\ub97c \uc9c0\uc6d0\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>V. Usage Conditions<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Normal operating conditions<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>V\u00fd\u0161ka: \u22642000 m<\/li>\n\n\n\n<li>Okolit\u00e1 teplota: -40\u2103~+85\u2103; prev\u00e1dzkov\u00e1 teplota zariadenia zodpoved\u00e1 pr\u00edslu\u0161n\u00fdm norm\u00e1m.<\/li>\n\n\n\n<li>Relative humidity: \u2264100% (no condensation);<\/li>\n\n\n\n<li>Environmental conditions: No corrosive gases, no flammable or explosive media, no severe vibration or impact;<\/li>\n\n\n\n<li>Sp\u00f4sob in\u0161tal\u00e1cie: Senzor sa zacvakne a nain\u0161taluje na k\u00e1blov\u00fa linku, zatia\u013e \u010do hlavn\u00e1 jednotka sa namontuje na panel a nain\u0161taluje na panel rozvodn\u00e9ho zariadenia. Miesto in\u0161tal\u00e1cie by malo by\u0165 vhodn\u00e9 na pozorovanie stavu indik\u00e1cie a \u00fadr\u017ebu.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Special usage conditions (customization required)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The altitude exceeds 2000m;<\/li>\n\n\n\n<li>Okolit\u00e1 teplota presahuje rozsah -40\u2103 a\u017e +85\u2103;<\/li>\n\n\n\n<li>Severely polluted, salt spray, and chemically corrosive environments;<\/li>\n\n\n\n<li>Siln\u00e9 podmienky elektromagnetick\u00e9ho ru\u0161enia;<\/li>\n\n\n\n<li>Nestandardn\u00e9 \u0161pecifik\u00e1cie vonkaj\u0161ieho priemeru k\u00e1bla;<\/li>\n\n\n\n<li>Sledovanie po\u010dtu riadkov a prisp\u00f4sobenie komunika\u010dn\u00fdch funkci\u00ed \u0161pecifick\u00fdm potreb\u00e1m.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VI. In\u0161tal\u00e1cia a \u00fadr\u017eba<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Po\u017eiadavky na in\u0161tal\u00e1ciu<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pred in\u0161tal\u00e1ciou skontrolujte vzh\u013ead produktu, \u010di nie je prasknut\u00fd alebo po\u0161koden\u00fd, a uistite sa, \u017ee sn\u00edma\u010de, hlavn\u00e1 jednotka a pripojovacie k\u00e1ble s\u00fa neporu\u0161en\u00e9. Otestujte funkciu indik\u00e1cie poruchy, aby ste sa uistili, \u017ee je norm\u00e1lna, a kontrolky by sa mali spr\u00e1vne rozsvieti\u0165, ke\u010f nie je \u017eiadna porucha.<\/li>\n\n\n\n<li>Vy\u010distite povrch k\u00e1blovej linky od oleja, prachu a cudz\u00edch predmetov. Nain\u0161talujte sn\u00edma\u010d por\u00fach na k\u00e1blov\u00fa linku, pri\u010dom sa uistite, \u017ee je klip bezpe\u010dne nain\u0161talovan\u00fd a \u017ee sn\u00edma\u010d dobre prilieha ku k\u00e1blu. Na ka\u017ed\u00fa linku nain\u0161talujte jeden sn\u00edma\u010d.<\/li>\n\n\n\n<li>Namontujte hostite\u013esk\u00fd panel na panel rozvodn\u00e9ho zariadenia, pevne ho pripevnite a zabezpe\u010dte, aby mont\u00e1\u017ena poloha bola vhodn\u00e1 na pozorovanie stavu kontroliek.<\/li>\n\n\n\n<li>Pou\u017eite \u0161pecializovan\u00fd prepojovac\u00ed k\u00e1bel na pripojenie sn\u00edma\u010da k pr\u00edslu\u0161n\u00e9mu rozhraniu na hostite\u013eskom paneli, pri\u010dom sa uistite, \u017ee je zapojenie bezpe\u010dn\u00e9 a nedoch\u00e1dza k uvo\u013enen\u00fdm spojeniam alebo zl\u00fdm kontaktom.<\/li>\n\n\n\n<li>Po in\u0161tal\u00e1cii zapnite a otestujte, aby ste simulovali skrat a zemn\u00e9 poruchy. Skontrolujte, \u010di pr\u00edslu\u0161n\u00e9 kontrolky svietia norm\u00e1lne, \u010di je funkcia automatick\u00e9ho resetovania norm\u00e1lna a \u010di je komunika\u010dn\u00e1 funkcia (ak existuje) norm\u00e1lna.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Po\u017eiadavky na \u00fadr\u017ebu<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pravidelne kontrolujte vzh\u013ead senzorov a hlavnej jednotky, aby ste sa uistili, \u017ee nie s\u00fa prasknut\u00e9, po\u0161koden\u00e9 alebo zne\u010disten\u00e9, \u017ee in\u0161tal\u00e1cia je pevn\u00e1 a nie je uvo\u013enen\u00e1, a \u017ee pripojovacie vodi\u010de nie s\u00fa star\u00e9 alebo po\u0161koden\u00e9.<\/li>\n\n\n\n<li>Pravidelne testujte funkciu indik\u00e1cie poruchy. Pri spusten\u00ed poruchy by sa pr\u00edslu\u0161n\u00e9 kontroln\u00e9 svetlo na linke malo norm\u00e1lne rozsvieti\u0165. Po odstr\u00e1nen\u00ed poruchy by sa kontroln\u00e9 svetlo malo automaticky resetova\u0165. Manu\u00e1lna funkcia resetovania by mala tie\u017e fungova\u0165 norm\u00e1lne.<\/li>\n\n\n\n<li>Vy\u010distite povrchy sn\u00edma\u010da a hlavnej jednotky od prachu a ne\u010dist\u00f4t, udr\u017eujte kryt such\u00fd a \u010dist\u00fd a zabr\u00e1\u0148te kor\u00f3zii od oleja a chemik\u00e1li\u00ed.<\/li>\n\n\n\n<li>\ud638\uc2a4\ud2b8 \uc804\uc6d0 \uacf5\uae09\uc774 \uc815\uc0c1\uc778\uc9c0, \ud1b5\uc2e0 \uae30\ub2a5(\uc788\ub294 \uacbd\uc6b0)\uc774 \uc548\uc815\uc801\uc778\uc9c0, \ub370\uc774\ud130 \uc5c5\ub85c\ub4dc\uac00 \uc815\uc0c1\uc778\uc9c0 \ud655\uc778\ud558\uc2ed\uc2dc\uc624.<\/li>\n\n\n\n<li>Ke\u010f zariadenie zlyh\u00e1, neindikuje alebo m\u00e1 komunika\u010dn\u00e9 abnormality, pr\u00ed\u010dina sa mus\u00ed okam\u017eite vy\u0161etri\u0165 a opravi\u0165. Ak oprava nie je mo\u017en\u00e1, zariadenie sa mus\u00ed vymeni\u0165. Prev\u00e1dzka s poruchou je pr\u00edsne zak\u00e1zan\u00e1.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VII. Upozornenia<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Produkt mus\u00ed by\u0165 in\u0161talovan\u00fd, odladen\u00fd a udr\u017eiavan\u00fd profesion\u00e1lnymi elektroin\u0161talat\u00e9rmi s kvalifik\u00e1ciou pre v\u00fdstavbu strednonap\u00e4\u0165ov\u00fdch rozvodov. Prev\u00e1dzka neprofesion\u00e1lnymi osobami je pr\u00edsne zak\u00e1zan\u00e1.<\/li>\n\n\n\n<li>\u4ea7\u54c1\u5fc5\u987b\u914d\u5408\u76f8\u5e94\u89c4\u683c\u7684\u7ebf\u7f06\u53ca\u914d\u7535\u8bbe\u5907\u4f7f\u7528\uff0c\u4e25\u7981\u5b89\u88c5\u5728\u4e0d\u540c\u7535\u538b\u7b49\u7ea7\u7684\u7ebf\u8def\u4e0a\uff0c\u5426\u5219\u5c06\u5bfc\u81f4\u8bbe\u5907\u635f\u574f\u53ca\u5b89\u5168\u4e8b\u6545\u3002<\/li>\n\n\n\n<li>Bez povolenia sa zariadenie nesmie rozobera\u0165 ani upravova\u0165, inak zanikne z\u00e1ruka a bezpe\u010dnostn\u00e1 z\u00e1ruka. Je pr\u00edsne zak\u00e1zan\u00e9 pou\u017e\u00edva\u0165 na n\u00e1siln\u00e9 rozoberanie ne\u0161pecializovan\u00e9 n\u00e1stroje.<\/li>\n\n\n\n<li>Senzory by mali by\u0165 in\u0161talovan\u00e9 mimo spojov k\u00e1blov, ohybov a zdrojov siln\u00e9ho elektromagnetick\u00e9ho ru\u0161enia. Hlavn\u00e1 jednotka by mala by\u0165 in\u0161talovan\u00e1 mimo komponentov produkuj\u00facich teplo, aby sa zabr\u00e1nilo vysok\u00fdm teplot\u00e1m ovplyv\u0148uj\u00facim v\u00fdkon zariadenia.<\/li>\n\n\n\n<li>Pri skladovan\u00ed umiestnite na such\u00e9, vetran\u00e9 a chladn\u00e9 miesto, vyh\u00fdbajte sa priamemu slne\u010dn\u00e9mu \u017eiareniu, vysokej teplote, vlhkosti a tlaku. Nedovo\u013ete, aby pri\u0161lo do kontaktu s ostr\u00fdmi predmetmi, ktor\u00e9 by mohli po\u0161kodi\u0165 vonkaj\u0161\u00ed pl\u00e1\u0161\u0165 a spojovacie vodi\u010de.<\/li>\n\n\n\n<li>Poruchov\u00e1 kontrolka je iba zariadenie na monitorovanie por\u00fach a nem\u00f4\u017ee nahradi\u0165 zariadenie rel\u00e9ovej ochrany. Poruchy na veden\u00ed je st\u00e1le potrebn\u00e9 rie\u0161i\u0165 v s\u00falade s predpismi o bezpe\u010dnosti distrib\u00facie elektrickej energie.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VIII. Model Description<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Model Identification<\/td><td>meaning<\/td><\/tr><tr><td>JY<\/td><td>K\u00f3d produktovej s\u00e9rie<\/td><\/tr><tr><td>EKL-4 \/ SJWL-EKL-4<\/td><td>S\u00e9riov\u00fd k\u00f3d indik\u00e1tora por\u00fach panelov\u00e9ho typu<\/td><\/tr><tr><td>Indik\u00e1tor poruchy panelu<\/td><td>Panelov\u00fd indik\u00e1tor por\u00fach pre centralizovan\u00e9 monitorovanie por\u00fach viacer\u00fdch k\u00e1blov\u00fdch veden\u00ed v zariadeniach distrib\u00facie elektrickej energie 10kV.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IX. Implementation Standards and Certification<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u56fd\u5bb6\u6807\u51c6\uff1aDL\/T 1073 \u914d\u7535\u7f51\u6545\u969c\u6307\u793a\u5668\u6280\u672f\u6761\u4ef6\uff0cGB\/T 17626 \u7535\u78c1\u517c\u5bb9 \u8bd5\u9a8c\u548c\u6d4b\u91cf\u6280\u672f\uff0cGB\/T 11022 \u9ad8\u538b\u5f00\u5173\u8bbe\u5907\u548c\u63a7\u5236\u8bbe\u5907\u6807\u51c6\u5171\u7528\u6280\u672f\u8981\u6c42\uff1b<\/li>\n\n\n\n<li>\u4ea7\u54c1\u5df2\u901a\u8fc7\u56fd\u5bb6\u7535\u529b\u8bbe\u5907\u8d28\u91cf\u76d1\u7763\u68c0\u9a8c\u4e2d\u5fc3\u578b\u5f0f\u8bd5\u9a8c\uff0c\u7b26\u5408\u56fd\u5bb6\u7535\u529b\u884c\u4e1a\u6807\u51c6\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>X. Popredajn\u00fd servis<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Product warranty period: 18 months from the date of manufacture, or 12 months from the date of commissioning (whichever comes first).<\/li>\n\n\n\n<li>During the warranty period, products will be repaired or replaced free of charge if quality issues arise.<\/li>\n\n\n\n<li>Poskytujeme technick\u00fa podporu, pokyny k in\u0161tal\u00e1cii a prisp\u00f4soben\u00e9 slu\u017eby (\u0161pecifick\u00fd vonkaj\u0161\u00ed priemer k\u00e1bla, po\u010det monitorovac\u00edch liniek a prisp\u00f4sobenie komunika\u010dn\u00fdch funkci\u00ed).<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Document Description<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The technical parameters in this manual are based on standard operating conditions. Special operating conditions need to be customized according to actual needs. The final specifications shall be subject to the product technical agreement and type test report.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Appendix: Product outline diagram<\/strong><strong><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"362\" height=\"344\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-EKL-4-Panel-Type-Fault-Indicator.png\" alt=\"JY-EKL-4-Panel-Type-Fault-Indicator\" class=\"wp-image-377\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-EKL-4-Panel-Type-Fault-Indicator.png 362w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/JY-EKL-4-Panel-Type-Fault-Indicator-300x285.png 300w\" sizes=\"(max-width: 362px) 100vw, 362px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>I. Product Overview The JY EKL-4 (SJWL-EKL-4) Panel Type Fault Indicator is a centralized fault monitoring device designed specifically for [&hellip;]<\/p>\n","protected":false},"featured_media":377,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[11],"class_list":["post-376","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-special-accessories-for-substation"],"acf":{"products_imagines":[377],"short_describe":"<p><strong>Technical Parameters<\/strong> Short circuit fault current: 600A Ground fault operating current: 20A Applicable voltage level: 6-35KV Applicable lead current: I&le;1000A Ambient temperature: -35 &deg;C &le; T &le; +75 %C Auto reset time: 8H (1 H ~ 24H optional) The number of action: &gt; 5000 times Installation size: Display Panel Host hole size 91.5mm(Tolerance 4-0.3mm) X43.5mm (tolerance 0.3mm) Display box size: 90 (L) x 42 (W) mm Protection class: Display IP40 sensor IP65<\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/376","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/377"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/377"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=376"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=376"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}