{"id":400,"date":"2026-01-23T06:35:36","date_gmt":"2026-01-23T06:35:36","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=400"},"modified":"2026-09-10T01:32:51","modified_gmt":"2026-09-10T01:32:51","slug":"bypass-operation-equipment-adapter-cable-3","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/bypass-operation-equipment-adapter-cable-3\/","title":{"rendered":"15kV \ubc14\uc774\ud328\uc2a4 \uc6b4\uc804 \uc7a5\ube44 \u2014 \uc5b4\ub311\ud130 \ucf00\uc774\ube14 (\ud035 \ud50c\ub7ec\uadf8 + \ubc30\uc218 \ud074\ub7a8\ud504)"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Preh\u013ead produktu<\/h2>\n\n\n\n<p class=\"sg-ai-highlighted-block wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">Adapt\u00e9rov\u00fd k\u00e1bel (r\u00fdchla z\u00e1str\u010dka + odtokov\u00e1 svorka) <\/a>je \u0161pecializovan\u00e9 pripojenie <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_cable\" target=\"_blank\" rel=\"noopener\">cable<\/a> navrhnut\u00e9 \u0161peci\u00e1lne pre prev\u00e1dzky obch\u00e1dzania pod nap\u00e4t\u00edm v distribu\u010dn\u00fdch syst\u00e9moch stredn\u00e9ho nap\u00e4tia 10kV\/15kV. Jeden koniec je vybaven\u00fd r\u00fdchloup\u00ednac\u00edm\/uvo\u013e\u0148ovac\u00edm rozhran\u00edm pre priame spojenie s obch\u00e1dzac\u00edm r\u00fdchloup\u00ednac\u00edm zariaden\u00edm; druh\u00fd koniec je vybaven\u00fd vysokonap\u00e4\u0165ovou uzem\u0148ovacou svorkou, ktor\u00fa je mo\u017en\u00e9 priamo pripoji\u0165 na hol\u00e9 vysokonap\u00e4\u0165ov\u00e9 vodi\u010de alebo k\u00e1ble. Tento dizajn umo\u017e\u0148uje r\u00fdchle pripojenie medzi vysokonap\u00e4\u0165ov\u00fdmi vedeniami a obch\u00e1dzac\u00edm zariaden\u00edm, \u010d\u00edm sa vytv\u00e1ra do\u010dasn\u00fd obch\u00e1dzkov\u00fd nap\u00e1jac\u00ed obvod, \u010do z neho rob\u00ed kritick\u00e9 zariadenie pre prev\u00e1dzky pod nap\u00e4t\u00edm v distribu\u010dn\u00fdch syst\u00e9moch stredn\u00e9ho nap\u00e4tia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Funkcie produktu<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Elektrick\u00fd a izola\u010dn\u00fd v\u00fdkon<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vyroben\u00e9 z vysokopevnostn\u00e9ho izolovan\u00e9ho k\u00e1bla s menovit\u00fdm nap\u00e4t\u00edm 15 kV. Vodi\u010d je lankov\u00fd meden\u00fd dr\u00f4t vysokej \u010distoty s vynikaj\u00facou elektrickou vodivos\u0165ou, n\u00edzkym prechodov\u00fdm odporom a menovit\u00fdm pr\u00fadov\u00fdm za\u0165a\u017een\u00edm 200 A\/630 A. Dlhodob\u00e1 prev\u00e1dzka generuje minim\u00e1lne teplo, so silnou odolnos\u0165ou proti kor\u00f3zii a oxid\u00e1cii.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Izola\u010dn\u00fd pl\u00e1\u0161\u0165 pou\u017e\u00edva vysokov\u00fdkonn\u00fa gumu EPDM (etyl\u00e9n-propyl\u00e9n-di\u00e9nov\u00fd monom\u00e9r) s vynikaj\u00facimi izola\u010dn\u00fdmi vlastnos\u0165ami. Odol\u00e1va menovit\u00e9mu nap\u00e4tiu syst\u00e9mu 15 kV, ako aj kr\u00e1tkodob\u00fdm prep\u00e4tiam, pri\u010dom sp\u013a\u0148a prev\u00e1dzkov\u00e9 po\u017eiadavky maxim\u00e1lneho pracovn\u00e9ho nap\u00e4tia 17,5 kV s \u00farov\u0148ou \u010diasto\u010dn\u00fdch v\u00fdbojov \u226410 pC (pri 1,5 U\u2080).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vstavan\u00e1 polovodi\u010dov\u00e1 tienen\u00e1 vrstva rovnomerne rozklad\u00e1 elektrick\u00e9 pole, \u010d\u00edm \u00fa\u010dinne potl\u00e1\u010da \u010diasto\u010dn\u00e9 v\u00fdboje. K\u00e1bel nepredstavuje riziko elektrickej er\u00f3zie ani dielektrick\u00e9ho prierazu po\u010das dlhodobej prev\u00e1dzky, \u010d\u00edm zabezpe\u010duje stabiln\u00fd a spo\u013eahliv\u00fd izola\u010dn\u00fd v\u00fdkon.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Odtokov\u00e1 svorka je vyroben\u00e1 z vysokopevnostn\u00e9ho vodiv\u00e9ho materi\u00e1lu s ve\u013ekou kontaktnou plochou, n\u00edzkym kontaktn\u00fdm odporom a schopnos\u0165ou zn\u00e1\u0161a\u0165 vysok\u00e9 pr\u00fadov\u00e9 za\u0165a\u017eenie. Up\u00ednanie je pevn\u00e9 a odoln\u00e9 vo\u010di uvo\u013eneniu a prehriatiu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kon\u0161truk\u010dn\u00e9 a bezpe\u010dnostn\u00e9 prvky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dva konce maj\u00fa odli\u0161n\u00e9 dizajny rozhran\u00ed. Jeden koniec je vybaven\u00fd r\u00fdchlospojovac\u00edm\/r\u00fdchlorozp\u00ednac\u00edm rozhran\u00edm, ktor\u00e9 je univerz\u00e1lne kompatibiln\u00e9 s hlavn\u00fdmi obtokov\u00fdmi r\u00fdchloup\u00ednac\u00edmi zariadeniami, \u010do umo\u017e\u0148uje r\u00fdchle spojenie bez \u010fal\u0161\u00edch n\u00e1strojov. Druh\u00fd koniec je vysokonap\u00e4\u0165ov\u00e1 odvod\u0148ovacia svorka, ktor\u00fa je mo\u017en\u00e9 priamo aplikova\u0165 na hol\u00e9 vysokonap\u00e4\u0165ov\u00e9 vodi\u010de alebo k\u00e1ble, \u010do umo\u017e\u0148uje jednoduch\u00fa in\u0161tal\u00e1ciu a v\u00fdrazne skracuje \u010das v\u00fdstavby.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Integrovan\u00e1 utesnen\u00e1 kon\u0161trukcia vyu\u017e\u00edva \u0161pecializovan\u00e9 tesniace prvky na rozhraniach, ktor\u00e9 poskytuj\u00fa ochranu proti vlhkosti, vode a kontamin\u00e1cii s kryt\u00edm IP67, \u010do umo\u017e\u0148uje dlhodob\u00fa stabiln\u00fa prev\u00e1dzku vo vlhkom, pra\u0161nom, vonkaj\u0161om a inom n\u00e1ro\u010dnom prostred\u00ed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Integrovan\u00e1 uzem\u0148ovacia\/ekvipotenci\u00e1lna spojovacia \u0161trukt\u00fara umo\u017e\u0148uje spo\u013eahliv\u00e9 uzemnenie, efekt\u00edvne rozpty\u013euje indukovan\u00e9 nap\u00e4tia a chybov\u00e9 pr\u00fady na zv\u00fd\u0161enie bezpe\u010dnosti syst\u00e9mu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Plne izolovan\u00e1 kon\u0161trukcia poskytuje vysok\u00fa pevnos\u0165 vonkaj\u0161ej izol\u00e1cie, \u010do umo\u017e\u0148uje dot\u00fdka\u0165 sa krytu priamo po\u010das prev\u00e1dzky bez rizika \u00farazu elektrick\u00fdm pr\u00fadom, \u010d\u00edm sa zabezpe\u010duje bezpe\u010dnos\u0165 prev\u00e1dzkov\u00e9ho a \u00fadr\u017ebov\u00e9ho person\u00e1lu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Environment\u00e1lna a poveternostn\u00e1 odolnos\u0165<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vynikaj\u00faca odolnos\u0165 vo\u010di poveternostn\u00fdm vplyvom, prisp\u00f4sobite\u013en\u00e1 \u0161irok\u00e9mu teplotn\u00e9mu rozsahu od -40 \u00b0C do +90 \u00b0C. Izol\u00e1cia k\u00e1bla a v\u00fdkon vodi\u010da sa pri vysok\u00fdch alebo n\u00edzkych teplot\u00e1ch nezhor\u0161uj\u00fa, bez rizika praskania alebo krehnutia, vhodn\u00e9 pre vonkaj\u0161ie aj vn\u00fatorn\u00e9 pou\u017eitie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9632\u6f6e\u3001\u9632\u6c34\u3001\u9632\u6c61\u3001\u8010\u76d0\u96fe\uff0c\u53ef\u5728\u6f6e\u6e7f\u3001\u591a\u5c18\u3001\u76d0\u96fe\u7b49\u6076\u52a3\u73af\u5883\u4e0b\u957f\u671f\u7a33\u5b9a\u8fd0\u884c\uff0c\u4e0d\u53d7\u96e8\u6c34\u6216\u51b7\u51dd\u6c34\u5f71\u54cd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Proti starnutiu, odoln\u00e9 vo\u010di UV \u017eiareniu a oz\u00f3novej kor\u00f3zii, s \u017eivotnos\u0165ou presahuj\u00facou 10 rokov, bez\u00fadr\u017ebovou prev\u00e1dzkou a zn\u00ed\u017een\u00fdmi dlhodob\u00fdmi prev\u00e1dzkov\u00fdmi a n\u00e1kladmi na \u00fadr\u017ebu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mechanick\u00e9 a kompatibiln\u00e9 funkcie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vysok\u00e1 mechanick\u00e1 pevnos\u0165 s odolnos\u0165ou vo\u010di \u0165ahu, ohybu a n\u00e1razu. K\u00e1bel odol\u00e1va \u0165ahov\u00fdm a ohybov\u00fdm nam\u00e1haniam, ktor\u00e9 sa vyskytuj\u00fa po\u010das prev\u00e1dzky, bez rizika deform\u00e1cie alebo po\u0161kodenia, vhodn\u00fd pre komplexn\u00e9 prev\u00e1dzkov\u00e9 prostredia v ter\u00e9ne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Odtokov\u00e1 svorka vyu\u017e\u00edva elastick\u00fd up\u00ednac\u00ed dizajn, kompatibiln\u00fd s hol\u00fdmi vysokonap\u00e4\u0165ov\u00fdmi vodi\u010dmi alebo k\u00e1blami r\u00f4znych \u0161pecifik\u00e1ci\u00ed. Up\u00ednanie je pevn\u00e9 so spo\u013eahliv\u00fdm kontaktom, odoln\u00e9 vo\u010di sk\u013aznutiu a uvo\u013eneniu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">R\u00fdchloup\u00ednacie\/uvo\u013e\u0148ovacie rozhranie je univerz\u00e1lne kompatibiln\u00e9 s be\u017en\u00fdmi obtokov\u00fdmi r\u00fdchloup\u00ednac\u00edmi zariadeniami, \u010do pon\u00faka siln\u00fa kompatibilitu s obtokov\u00fdmi k\u00e1blami, obtokov\u00fdmi prep\u00edna\u010dmi a in\u00fdmi zariadeniami r\u00f4znych \u0161pecifik\u00e1ci\u00ed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Technick\u00e9 parametre<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Kateg\u00f3ria parametra<\/td><td>Predmet<\/td><td>Technick\u00e1 \u0161pecifik\u00e1cia<\/td><\/tr><tr><td>Menovit\u00e9 elektrick\u00e9 parametre<\/td><td>Syst\u00e9mov\u00e9 nap\u00e4tie (Un)<\/td><td>10kV\/15kV<\/td><\/tr><tr><td><\/td><td>Menovit\u00e9 nap\u00e4tie (Ue)<\/td><td>15kV<\/td><\/tr><tr><td><\/td><td>| Maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie (Um)<\/td><td>17,5 kV<\/td><\/tr><tr><td><\/td><td>Menovit\u00e1 frekvencia (fn)<\/td><td>50Hz\/60Hz<\/td><\/tr><tr><td><\/td><td>| V\u00fdkonov\u00e9 frekven\u010dn\u00e9 odoln\u00e9 nap\u00e4tie<\/td><td>42kV\/5min (such\u00fd test), bez prierazu, bez preskoku<\/td><\/tr><tr><td><\/td><td>| Nap\u00e4tie pri odolnosti vo\u010di impulzn\u00e9mu prep\u00e4tiu<\/td><td>95kV (\u0161pi\u010dkov\u00e9), bez prierazu, bez preskoku<\/td><\/tr><tr><td><\/td><td>\u00darove\u0148 \u010diasto\u010dn\u00e9ho v\u00fdboja<\/td><td>\u226410pC (pri 1,5U\u2080)<\/td><\/tr><tr><td><\/td><td>| Menovit\u00e1 pr\u00fadov\u00e1 \u00farove\u0148<\/td><td>200A\/630A (volite\u013en\u00e9)<\/td><\/tr><tr><td><\/td><td>| Menovit\u00fd skratov\u00fd v\u00fddr\u017en\u00fd pr\u00fad<\/td><td>20kA\/2s, 25kA\/2s (volite\u013en\u00e9)<\/td><\/tr><tr><td><\/td><td>| Odpor kontaktu<\/td><td>\u226450\u03bc\u03a9<\/td><\/tr><tr><td>Kon\u0161truk\u010dn\u00e9 a materi\u00e1lov\u00e9 parametre<\/td><td>Prim\u00e1rny materi\u00e1l<\/td><td>Poc\u00ednovan\u00fd meden\u00fd dr\u00f4t (vodi\u010d), EPDM guma (izola\u010dn\u00e1 vrstva), poc\u00ednovan\u00e1 me\u010f (r\u00fdchloup\u00ednacie rozhranie\/odvod\u0148ovacia svorka)<\/td><\/tr><tr><td><\/td><td>Hodnotenie stup\u0148a ochrany<\/td><td>IP67<\/td><\/tr><tr><td><\/td><td>| Rozhranie \u0161tandard<\/td><td>Jeden koniec r\u00fdchlospojka\/r\u00fdchloodpojovacie rozhranie, jeden koniec vysokonap\u00e4\u0165ov\u00e1 odvod\u0148ovacia svorka, v s\u00falade s priemyseln\u00fdmi normami pre zariadenia na obch\u00e1dzkov\u00fa prev\u00e1dzku<\/td><\/tr><tr><td><\/td><td>| Kompatibiln\u00e9 vybavenie<\/td><td>10kV\/15kV\u65c1\u8def\u8fd0\u884c\u5feb\u901f\u63d2\u62d4\u8bbe\u5907\uff0c\u88f8\u9ad8\u538b\u5bfc\u4f53\/\u7535\u7f06<\/td><\/tr><tr><td>Environment\u00e1lne parametre<\/td><td>Pou\u017eite\u013en\u00e1 v\u00fd\u0161ka<\/td><td>\u22642000 m (dostupn\u00e9 prisp\u00f4sobenie pre vysok\u00fa nadmorsk\u00fa v\u00fd\u0161ku)<\/td><\/tr><tr><td><\/td><td>| Okolit\u00e1 teplota<\/td><td>-40 \u00b0C a\u017e +90 \u00b0C (prev\u00e1dzkov\u00e1 teplota), -40 \u00b0C a\u017e +70 \u00b0C (skladovacia teplota)<\/td><\/tr><tr><td><\/td><td>Relat\u00edvna vlhkos\u0165<\/td><td>\u2264100% (nekondenzuj\u00faca)<\/td><\/tr><tr><td><\/td><td>| Seizmick\u00e1 hodnota<\/td><td>8. ro\u010dn\u00edk<\/td><\/tr><tr><td>Platn\u00e9 normy<\/td><td><\/td><td>GB\/T 12706, DL\/T 1476 \u7535\u529b\u5b89\u5168\u5de5\u5177\u548c\u4eea\u5668\u9884\u9632\u6027\u8bd5\u9a8c\u89c4\u7a0b, DL\/T 814 \u914d\u7535\u81ea\u52a8\u5316\u7ec8\u7aef<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Rozsah pou\u017eitia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pou\u017eite\u013en\u00e9 nap\u00e4\u0165ov\u00e9 \u00farovne: 10kV\/15kV strednonap\u00e4\u0165ov\u00e9 distribu\u010dn\u00e9 syst\u00e9my AC, kompatibiln\u00e9 s distribu\u010dn\u00fdmi zariadeniami s maxim\u00e1lnym prev\u00e1dzkov\u00fdm nap\u00e4t\u00edm 17,5kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pou\u017eite\u013en\u00e9 prev\u00e1dzkov\u00e9 scen\u00e1re:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dadr\u017eba a moderniz\u00e1cia pod nap\u00e4t\u00edm na hol\u00fdch vysokonap\u00e4\u0165ov\u00fdch vodi\u010doch a k\u00e1bloch 10kV\/15kV, sl\u00fa\u017eiace ako prechodov\u00e9 spojenie medzi vysokonap\u00e4\u0165ov\u00fdmi vedeniami a obtokov\u00fdmi k\u00e1blami;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u017div\u00e9 obch\u00e1dzkov\u00e9 oper\u00e1cie na mestsk\u00fdch nadzemn\u00fdch distribu\u010dn\u00fdch vedeniach, k\u00e1blov\u00fdch vedeniach, distribu\u010dn\u00fdch syst\u00e9moch priemyseln\u00fdch a bansk\u00fdch podnikov a distribu\u010dn\u00fdch zariadeniach v transforma\u010dn\u00fdch staniciach obnovite\u013en\u00fdch zdrojov energie (fotovoltaika\/vetern\u00e1 energia) <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a>;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do\u010dasn\u00e9 z\u00e1lo\u017en\u00e9 nap\u00e1janie pre distribu\u010dn\u00e9 zariadenia vo viacer\u00fdch scen\u00e1roch vr\u00e1tane vn\u00fatorn\u00fdch\/vonkaj\u0161\u00edch distribu\u010dn\u00fdch miestnost\u00ed, podzemn\u00fdch in\u017einierskych tunelov a k\u00e1blov\u00fdch tunelov.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Funk\u010dn\u00fd \u00fa\u010del: Dosiahnu\u0165 izola\u010dn\u00e9 oddelenie a vodiv\u00e9 spojenie medzi vysokonap\u00e4\u0165ov\u00fdmi vedeniami a obch\u00e1dzan\u00fdm zariaden\u00edm, \u010d\u00edm sa r\u00fdchlo vytvor\u00ed do\u010dasn\u00fd obch\u00e1dzkov\u00fd nap\u00e1jac\u00ed obvod. T\u00fdm sa zabezpe\u010d\u00ed nepretr\u017eit\u00e9 nap\u00e1janie z\u00e1kazn\u00edkov po\u010das \u00fadr\u017eby a moderniz\u00e1cie distribu\u010dn\u00fdch veden\u00ed a zariaden\u00ed, \u010d\u00edm sa poskytne bezpe\u010dn\u00e9 a spo\u013eahliv\u00e9 rie\u0161enie pripojenia pre pr\u00e1ce pod nap\u00e4t\u00edm v strednonap\u00e4\u0165ov\u00fdch distribu\u010dn\u00fdch syst\u00e9moch.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Prev\u00e1dzkov\u00e9 podmienky<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Norm\u00e1lne prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nadmo\u0159sk\u00e1 v\u00fd\u0161ka: \u22642000 m<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okolit\u00e1 teplota: -40 \u00b0C a\u017e +90 \u00b0C; prev\u00e1dzkov\u00e1 teplota zariadenia sp\u013a\u0148a pr\u00edslu\u0161n\u00e9 normy<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Relat\u00edvna vlhkos\u0165: \u2264100 % (nekondenzuj\u00faca)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Environment\u00e1lne podmienky: \u017diadne koroz\u00edvne plyny, \u017eiadne hor\u013eav\u00e9 alebo v\u00fdbu\u0161n\u00e9 m\u00e9di\u00e1, \u017eiadne siln\u00e9 vibr\u00e1cie alebo otrasy<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sp\u00f4sob in\u0161tal\u00e1cie: Odvod\u0148ovacia svorka aplikovan\u00e1 na hol\u00e9 vysokonap\u00e4\u0165ov\u00e9 vodi\u010de\/k\u00e1ble; r\u00fdchloup\u00ednacie rozhranie pripojen\u00e9 priamo k rozhraniu obch\u00e1dzan\u00e9ho zariadenia zasunut\u00edm\/vytiahnut\u00edm; povolen\u00e1 horizont\u00e1lna alebo vertik\u00e1lna in\u0161tal\u00e1cia; priestor na in\u0161tal\u00e1ciu mus\u00ed sp\u013a\u0148a\u0165 prev\u00e1dzkov\u00e9 po\u017eiadavky<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160peci\u00e1lne prev\u00e1dzkov\u00e9 podmienky (vy\u017eaduje sa prisp\u00f4sobenie)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nadmorsk\u00e1 v\u00fd\u0161ka presahuj\u00faca 2000 m<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okolit\u00e1 teplota mimo rozsah -40 \u00b0C a\u017e +90 \u00b0C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0164a\u017eko zne\u010disten\u00e9, slanou hmlou alebo chemicky koroz\u00edvne prostredia<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vysok\u00e9 vibr\u00e1cie alebo prev\u00e1dzkov\u00e9 podmienky s vysok\u00fdmi n\u00e1razmi<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nestandardn\u00e9 \u0161pecifik\u00e1cie rozhrania alebo \u0161peci\u00e1lne po\u017eiadavky na d\u013a\u017eku k\u00e1bla<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0160peci\u00e1lne menovit\u00e9 pr\u00fady alebo po\u017eiadavky na pr\u00fadov\u00fa za\u0165a\u017eite\u013enos\u0165<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">In\u0161tal\u00e1cia a \u00fadr\u017eba<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na in\u0161tal\u00e1ciu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pred in\u0161tal\u00e1ciou skontrolujte vzh\u013ead produktu, \u010di neobsahuje praskliny, po\u0161kodenia a dutiny; overte, \u010di povrch izol\u00e1cie nie je po\u0161koden\u00fd. Skontrolujte odtokov\u00fa svorku a rozhranie r\u00fdchleho konektora, \u010di nie s\u00fa skorodovan\u00e9 a zdeformovan\u00e9; potvr\u010fte, \u017ee elastick\u00e9 upnutie odtokovej svorky je spo\u013eahliv\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vy\u010distite povrch hol\u00fdch vysokonap\u00e4\u0165ov\u00fdch vodi\u010dov\/k\u00e1blov, odstr\u00e1\u0148te mastnotu, prach a cudzie \u010dastice, aby bola up\u00ednacia plocha such\u00e1 a \u010dist\u00e1. Vy\u010distite rozhranie r\u00fdchlokonektora a zodpovedaj\u00face rozhranie zariadenia na obtok, odstr\u00e1\u0148te mastnotu, prach a cudzie \u010dastice, aby boli rozhrania such\u00e9 a \u010dist\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Na vonkaj\u0161iu stenu r\u00fdchloup\u00ednacieho rozhrania naneste rovnomern\u00fa vrstvu \u0161pecializovan\u00e9ho silik\u00f3nov\u00e9ho maziva, aby ste zabr\u00e1nili po\u0161kodeniu izola\u010dnej vrstvy po\u010das in\u0161tal\u00e1cie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pevne pripnite odtokov\u00fa svorku na hol\u00fd vysokonap\u00e4\u0165ov\u00fd vodi\u010d\/k\u00e1bel, \u010d\u00edm zabezpe\u010d\u00edte dostato\u010dn\u00fa kontaktn\u00fa plochu a spo\u013eahliv\u00fd kontakt. Bezpe\u010dne pripojte r\u00fdchloup\u00ednacie rozhranie k rozhraniu obtokov\u00e9ho zariadenia, \u010d\u00edm zabezpe\u010d\u00edte \u00fapln\u00e9 zasunutie. Zaistite mechanizmus proti ne\u00famyseln\u00e9mu vysunutiu. Po in\u0161tal\u00e1cii overte, \u010di nedoch\u00e1dza k uvo\u013eneniu alebo nes\u00faladu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po in\u0161tal\u00e1cii vykonajte sk\u00fa\u0161ku izola\u010dn\u00e9ho odporu a sk\u00fa\u0161ku odolnosti vo\u010di nap\u00e4tiu s frekvenciou siete pred uveden\u00edm do prev\u00e1dzky.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na \u00fadr\u017ebu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pravidelne kontrolujte vonkaj\u0161\u00ed povrch k\u00e1bla, \u010di nie je popraskan\u00fd, po\u0161koden\u00fd, \u010di nevykazuje zn\u00e1mky v\u00fdboja alebo nahromadenia ne\u010dist\u00f4t; overte, \u010di je odvod\u0148ovacia svorka pevne utiahnut\u00e1 bez uvo\u013enenia a \u010di je pripojenie r\u00fdchloup\u00ednacieho rozhrania spo\u013eahliv\u00e9 a bez kor\u00f3zie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pravidelne testujte izola\u010dn\u00fd odpor, aby ste potvrdili, \u017ee v\u00fdkon sp\u013a\u0148a po\u017eiadavky, a aby ste v\u010das odhalili potenci\u00e1lne poruchy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vy\u010distite povrch k\u00e1blov a rozhran\u00ed, odstr\u00e1\u0148te nahromaden\u00fd prach a ne\u010distoty. Udr\u017eujte izola\u010dn\u00fd povrch such\u00fd a \u010dist\u00fd, zabr\u00e1\u0148te degrad\u00e1cii od mastnoty a chemick\u00fdch l\u00e1tok.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ak sa na k\u00e1bli alebo rozhraniach objavia praskliny, po\u0161kodenia, vybitie, prehriatie alebo in\u00e9 abnormality, okam\u017eite vyra\u010fte jednotku z prev\u00e1dzky a vyme\u0148te ju. Prev\u00e1dzka so zn\u00e1mymi chybami je pr\u00edsne zak\u00e1zan\u00e1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vkladanie\/vyberanie r\u00fdchloup\u00ednacieho rozhrania a up\u00ednanie\/uvo\u013e\u0148ovanie odtokovej svorky sa mus\u00ed vykon\u00e1va\u0165 pomocou \u0161pecializovan\u00fdch izolovan\u00fdch prev\u00e1dzkov\u00fdch n\u00e1strojov. Prev\u00e1dzka pod nap\u00e4t\u00edm hol\u00fdmi rukami je pr\u00edsne zak\u00e1zan\u00e1. V\u0161etky oper\u00e1cie musia pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distrib\u00facie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Bezpe\u010dnostn\u00e9 opatrenia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Produkt mus\u00ed by\u0165 nain\u0161talovan\u00fd, uveden\u00fd do prev\u00e1dzky a udr\u017eiavan\u00fd kvalifikovan\u00fdm elektrotechnick\u00fdm person\u00e1lom s certifik\u00e1ciou pre pr\u00e1ce na zariadeniach stredn\u00e9ho nap\u00e4tia pod nap\u00e4t\u00edm. Prev\u00e1dzka neopr\u00e1vnen\u00fdm person\u00e1lom je pr\u00edsne zak\u00e1zan\u00e1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobok sa mus\u00ed pou\u017e\u00edva\u0165 v spojen\u00ed s obch\u00e1dzkov\u00fdm prev\u00e1dzkov\u00fdm zariaden\u00edm a vysokonap\u00e4\u0165ov\u00fdmi vedeniami zodpovedaj\u00facich \u0161pecifik\u00e1ci\u00ed. Pou\u017e\u00edvanie nezhodn\u00fdch zariaden\u00ed s r\u00f4znym nap\u00e4t\u00edm alebo pr\u00fadov\u00fdmi hodnotami je pr\u00edsne zak\u00e1zan\u00e9, preto\u017ee to povedie k zlyhaniu izol\u00e1cie a bezpe\u010dnostn\u00fdm incidentom.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">K\u00e1bel sa nesmie rozobera\u0165 ani upravova\u0165 bez povolenia, preto\u017ee t\u00fdm zanikne z\u00e1ruka a bezpe\u010dnostn\u00e9 z\u00e1ruky. Pou\u017e\u00edvanie ne\u0161pecializovan\u00fdch n\u00e1strojov na n\u00e1siln\u00fa in\u0161tal\u00e1ciu alebo demont\u00e1\u017e rozhran\u00ed alebo dren\u00e1\u017enych svoriek je pr\u00edsne zak\u00e1zan\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po\u010das in\u0161tal\u00e1cie je pr\u00edsne zak\u00e1zan\u00e9 po\u0161kodenie izola\u010dn\u00e9ho povrchu. Silik\u00f3nov\u00e9 mazivo sa mus\u00ed nanies\u0165 rovnomerne, aby sa neohrozil v\u00fdkon izol\u00e1cie a \u00fa\u010dinnos\u0165 tesnenia. Odvod\u0148ovacia svorka mus\u00ed by\u0165 pevne utiahnut\u00e1 s spo\u013eahliv\u00fdm kontaktom, aby sa zabr\u00e1nilo prehriatiu a v\u00fdboju v d\u00f4sledku zl\u00e9ho kontaktu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po\u010das skladovania mus\u00ed by\u0165 v\u00fdrobok uchov\u00e1van\u00fd v suchom, dobre vetranom a chladnom prostred\u00ed, mimo priameho slne\u010dn\u00e9ho \u017eiarenia, vysok\u00fdch tepl\u00f4t, vlhkosti a stla\u010denia. Kontakt s ostr\u00fdmi predmetmi, ktor\u00e9 by mohli po\u0161kodi\u0165 izola\u010dn\u00fa vrstvu, je pr\u00edsne zak\u00e1zan\u00fd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pri pr\u00e1cach na zariadeniach pod nap\u00e4t\u00edm, ktor\u00e9 zah\u0155\u0148aj\u00fa dren\u00e1\u017enu svorku a rozhranie r\u00fdchlo-z\u00e1suvky, je potrebn\u00e9 pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distrib\u00facie, zabezpe\u010di\u0165 primeran\u00e9 bezpe\u010dnostn\u00e9 ochrann\u00e9 opatrenia a neopr\u00e1vnen\u00e9 pr\u00e1ce s\u00fa pr\u00edsne zak\u00e1zan\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ozna\u010denie modelu<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Identifik\u00e1tor modelu<\/th><th>V\u00fdznam<\/th><\/tr><\/thead><tbody><tr><td>15kV<\/td><td>Pou\u017eite\u013en\u00e1 \u00farove\u0148 syst\u00e9mov\u00e9ho nap\u00e4tia; menovit\u00e9 nap\u00e4tie 15 kV, maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie 17,5 kV<\/td><\/tr><tr><td>R\u00fdchla obj\u00edmka + odtokov\u00e1 svorka<\/td><td>Typ rozhrania; jeden koniec r\u00fdchlospojka\/r\u00fdchloodpojite\u013en\u00e9 rozhranie, jeden koniec vysokonap\u00e4\u0165ov\u00e1 odvod\u0148ovacia svorka<\/td><\/tr><tr><td>Adapt\u00e9rov\u00fd k\u00e1bel<\/td><td>Prechodov\u00fd k\u00e1bel na pripojenie medzi vysokonap\u00e4\u0165ov\u00fdmi vedeniami a zariadeniami pre obtokov\u00fa prev\u00e1dzku<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Platn\u00e9 normy a certifik\u00e1cie<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Medzin\u00e1rodn\u00fd \u0161tandard: IEC 60840 Met\u00f3dy sk\u00fa\u0161ania a po\u017eiadavky na silov\u00e9 k\u00e1ble s extrudovanou izol\u00e1ciou a ich pr\u00edslu\u0161enstvo pre menovit\u00e9 nap\u00e4tia nad 30 kV (Um=36 kV) do 150 kV (Um=170 kV)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fd\u5bb6\u6807\u51c6\uff1aGB\/T 12706 \u989d\u5b9a\u7535\u538b1kV\uff08Um=1.2kV\uff09\u81f335kV\uff08Um=40.5kV\uff09\u6324\u5851\u7edd\u7f18\u7535\u529b\u7535\u7f06\u53ca\u9644\u4ef6\uff1bDL\/T 1476 \u7535\u529b\u5b89\u5168\u5de5\u5668\u5177\u548c\u4eea\u8868\u9884\u9632\u6027\u8bd5\u9a8c\u89c4\u7a0b\uff1bDL\/T 814 \u914d\u7535\u81ea\u52a8\u5316\u7ec8\u7aef<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ea7\u54c1\u5df2\u901a\u8fc7\u56fd\u5bb6\u7535\u529b\u5b89\u5168\u5de5\u5668\u5177\u8d28\u91cf\u76d1\u7763\u68c0\u9a8c\u4e2d\u5fc3\u578b\u5f0f\u8bd5\u9a8c\uff0c\u7b26\u5408\u56fd\u5bb6\u7535\u529b\u884c\u4e1a\u6807\u51c6\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Popredajn\u00fd servis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Z\u00e1ru\u010dn\u00e1 doba: 18 mesiacov od d\u00e1tumu v\u00fdroby, alebo 12 mesiacov od d\u00e1tumu uvedenia do prev\u00e1dzky, pod\u013ea toho, \u010do nastane sk\u00f4r<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V z\u00e1ru\u010dnej lehote bud\u00fa v\u00fdrobky s v\u00fdrobn\u00fdmi chybami bezplatne opraven\u00e9 alebo vymenen\u00e9<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Technick\u00e1 podpora, pokyny k in\u0161tal\u00e1cii a slu\u017eby prisp\u00f4sobenia s\u00fa k dispoz\u00edcii (\u0161peci\u00e1lne \u0161pecifik\u00e1cie a prisp\u00f4sobenia pre \u0161peci\u00e1lne prev\u00e1dzkov\u00e9 podmienky)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Documentation Notes<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u624b\u518c\u4e2d\u7684\u6280\u672f\u53c2\u6570\u57fa\u4e8e\u6807\u51c6\u64cd\u4f5c\u6761\u4ef6\u3002\u7279\u6b8a\u64cd\u4f5c\u6761\u4ef6\u9700\u8981\u6839\u636e\u5b9e\u9645\u8981\u6c42\u8fdb\u884c\u5b9a\u5236\u3002\u4ea7\u54c1\u6280\u672f\u534f\u8bae\u548c\u578b\u5f0f\u8bd5\u9a8c\u62a5\u544a\u5e94\u4f5c\u4e3a\u6700\u7ec8\u6743\u5a01\u53c2\u8003\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pr\u00edloha: N\u00e1kres obrysu produktu<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"461\" height=\"459\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/Adapter-cable-double-quick-plug2.png\" alt=\"adapt\u00e9r-k\u00e1bel-r\u00fdchlospojka-alig\u00e1tor\" class=\"wp-image-401\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/Adapter-cable-double-quick-plug2.png 461w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/Adapter-cable-double-quick-plug2-300x300.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/Adapter-cable-double-quick-plug2-150x150.png 150w\" sizes=\"(max-width: 461px) 100vw, 461px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The Adapter Cable (Quick Plug + Drainage Clamp) is a dedicated connecting cable designed specifically for live-line bypass [&hellip;]<\/p>\n","protected":false},"featured_media":401,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[13],"class_list":["post-400","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-quick-plug-series"],"acf":{"products_imagines":[401],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/400","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/401"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/401"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=400"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=400"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}