{"id":408,"date":"2026-01-23T06:48:01","date_gmt":"2026-01-23T06:48:01","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=408"},"modified":"2026-09-08T09:10:06","modified_gmt":"2026-09-08T09:10:06","slug":"quick-release-intermediate-connector-with-flange","status":"publish","type":"products","link":"https:\/\/yieou.com\/sk\/product\/quick-release-intermediate-connector-with-flange\/","title":{"rendered":"15kV R\u00fdchloup\u00ednac\u00ed stredov\u00fd konektor (s pr\u00edrubou)"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Preh\u013ead produktu<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/sk\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\">The 15kV Quick Release Intermediate Connector <\/a>(with Flange, 15kV Quick release intermediate <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrical_connector\" target=\"_blank\" rel=\"noopener\">konektor<\/a> with flange) is a dedicated rapid-connection device designed specifically for live-line bypass operations in 10kV\/15kV medium-voltage power distribution systems. Both ends employ standardized quick-connect\/disconnect interfaces, and a fixed mounting flange is integrated at the center. This design enables rapid mating of two bypass cable segments with secure fixed installation, establishing a temporary bypass power supply circuit. The connector combines both connection and mounting functions, and is compatible with bracket-mounted installation scenarios. It serves as a core component in medium-voltage distribution live-line bypass operations.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Funkcie produktu<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Elektrick\u00e9 a vodiv\u00e9 vlastnosti<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Konektor vyu\u017e\u00edva vysoko \u010dist\u00e9 meden\u00e9 vodiv\u00e9 jadro, ktor\u00e9 poskytuje vynikaj\u00facu vodivos\u0165 s extr\u00e9mne n\u00edzkym prechodov\u00fdm odporom. Podporuje menovit\u00fd pr\u00fad 200A\/630A pre trval\u00fa prev\u00e1dzku bez tepeln\u00e9ho n\u00e1rastu alebo oxid\u00e1cie, \u010d\u00edm sp\u013a\u0148a po\u017eiadavky aplik\u00e1ci\u00ed nap\u00e1jania s vysok\u00fdm pr\u00fadov\u00fdm obtokom.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vodiv\u00fd jadro vyu\u017e\u00edva elastick\u00fa kontaktn\u00fa \u0161trukt\u00faru s ve\u013ekou kontaktnou plochou a rovnomern\u00fdm kontaktn\u00fdm tlakom, schopn\u00fa odola\u0165 \u010dast\u00fdm cyklom sp\u00e1jania\/rozp\u00e1jania. V\u00fdkon kontaktov zost\u00e1va stabiln\u00fd bez rizika uvo\u013enenia alebo zl\u00e9ho kontaktu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5185\u7f6e\u7535\u573a\u4f18\u5316\u7ed3\u6784\u53ef\u5747\u5300\u5206\u5e03\u754c\u9762\u7535\u573a\uff0c\u6709\u6548\u6291\u5236\u5c40\u90e8\u653e\u7535\u3002\u957f\u671f\u8fd0\u884c\u65e0\u7535\u6c14\u8150\u8680\u6216\u4ecb\u7535\u51fb\u7a7f\u98ce\u9669\uff0c\u786e\u4fdd\u7535\u6c14\u6027\u80fd\u7a33\u5b9a\u53ef\u9760\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kon\u0161truk\u010dn\u00e9 a bezpe\u010dnostn\u00e9 prvky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Obe koncovky vyu\u017e\u00edvaj\u00fa \u0161tandardizovan\u00e9 r\u00fdchloup\u00ednacie\/uvo\u013e\u0148ovacie rozhrania, ktor\u00e9 pr\u00edsne sp\u013a\u0148aj\u00fa priemyseln\u00e9 normy. S\u00fa plne zamenite\u013en\u00e9 s be\u017en\u00fdmi 15kV obtokov\u00fdmi k\u00e1blami a r\u00fdchloup\u00ednac\u00edmi zariadeniami, \u010d\u00edm pon\u00fakaj\u00fa siln\u00fa kompatibilitu a prisp\u00f4sobivos\u0165 pri kon\u0161trukcii obtokov\u00fdch obvodov r\u00f4znych konfigur\u00e1ci\u00ed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Stredovo integrovan\u00e1 pevn\u00e1 pr\u00edrubov\u00e1 kon\u0161trukcia umo\u017e\u0148uje priame skrutkov\u00e9 upevnenie k dr\u017eiakom alebo krytom zariaden\u00ed, \u010d\u00edm zais\u0165uje stabiln\u00fa mont\u00e1\u017e konektora a zabra\u0148uje uvo\u013eneniu rozhrania sp\u00f4soben\u00e9mu vibr\u00e1ciami alebo nap\u00e4t\u00edm k\u00e1bla po\u010das prev\u00e1dzky.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Integrovan\u00fd modul\u00e1rny dizajn obsahuje r\u00fdchloup\u00ednac\u00ed spojovac\u00ed mechanizmus, ktor\u00fd nevy\u017eaduje \u017eiadne \u010fal\u0161ie n\u00e1stroje, \u010do umo\u017e\u0148uje r\u00fdchle sp\u00e1janie a odp\u00e1janie dvoch segmentov obtokov\u00e9ho k\u00e1bla a v\u00fdrazne skracuje \u010das v\u00fdstavby obtokov\u00fdch oper\u00e1ci\u00ed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vstavan\u00e1 samozatv\u00e1racia kon\u0161trukcia proti sp\u00e4tn\u00e9mu vysunutiu sa automaticky uzamkne po \u00faplnom zasunut\u00ed rozhrania, \u010d\u00edm sa zabr\u00e1ni uvo\u013eneniu alebo odpojeniu po\u010das prev\u00e1dzky a zv\u00fd\u0161i sa spo\u013eahlivos\u0165 pripojen\u00ed obvodov. Plne izolovan\u00fd ochrann\u00fd dizajn poskytuje vysok\u00fa integritu vonkaj\u0161ej izol\u00e1cie, \u010do umo\u017e\u0148uje bezpe\u010dn\u00fd kontakt s krytom po\u010das prev\u00e1dzky pod nap\u00e4t\u00edm bez rizika \u00farazu elektrick\u00fdm pr\u00fadom.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Environment\u00e1lna a poveternostn\u00e1 odolnos\u0165<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Konektor vykazuje vynikaj\u00facu odolnos\u0165 vo\u010di poveternostn\u00fdm vplyvom, vhodn\u00fd pre \u0161irok\u00fd prev\u00e1dzkov\u00fd teplotn\u00fd rozsah od -40\u00b0C do +90\u00b0C. Vodiv\u00fd stred aj izola\u010dn\u00e1 vrstva si zachov\u00e1vaj\u00fa pln\u00fd v\u00fdkon pri extr\u00e9mnych teplot\u00e1ch bez rizika prasknutia alebo skrehnutia, v\u010faka \u010domu je vhodn\u00fd pre vonkaj\u0161ie aj vn\u00fatorn\u00e9 prev\u00e1dzkov\u00e9 prostredia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Konektor je dimenzovan\u00fd na stupe\u0148 krytia IP67 proti vlhkosti, vode, prachu, kontamin\u00e1cii a slanej hmle, \u010do umo\u017e\u0148uje dlhodob\u00fa stabiln\u00fa prev\u00e1dzku v n\u00e1ro\u010dn\u00fdch prostrediach vr\u00e1tane vlhk\u00fdch, pra\u0161n\u00fdch a slan\u00fdch podmienok, s odolnos\u0165ou vo\u010di vniknutiu da\u017e\u010fovej vody a kondenz\u00e1tu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Konektor je odoln\u00fd proti st\u00e1rnut\u00ed a korozi. Povrch vodiv\u00e9ho j\u00e1dra je poc\u00ednovan\u00fd nebo post\u0159\u00edb\u0159en\u00fd, aby se zabr\u00e1nilo oxida\u010dn\u00ed korozi. \u017divotnost p\u0159esahuje 10 let p\u0159i bez\u00fadr\u017ebov\u00e9m provozu, co\u017e sni\u017euje dlouhodob\u00e9 provozn\u00ed a servisn\u00ed n\u00e1klady.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mechanick\u00e9 a kompatibiln\u00e9 funkcie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Konektor poskytuje vysok\u00fa mechanick\u00fa pevnos\u0165 s odolnos\u0165ou proti n\u00e1razom a vibr\u00e1ci\u00e1m, schopn\u00fd odola\u0165 mechanick\u00e9mu nam\u00e1haniu pri preprave, in\u0161tal\u00e1cii a prev\u00e1dzke bez rizika deform\u00e1cie alebo po\u0161kodenia. Pr\u00edrubov\u00e1 kon\u0161trukcia zais\u0165uje bezpe\u010dn\u00e9 upevnenie schopn\u00e9 odola\u0165 definovan\u00fdm \u0165ahov\u00fdm a kr\u00fatiacim za\u0165a\u017eeniam, vhodn\u00e9 pre scen\u00e1re in\u0161tal\u00e1cie s pevn\u00fdm dr\u017eiakom.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kompatibiln\u00e9 s obtokov\u00fdmi k\u00e1blami 10kV\/15kV, obtokov\u00fdmi sp\u00edna\u010dmi, prep\u00e1jac\u00edmi k\u00e1blami a r\u00f4znymi in\u00fdmi zariadeniami na obtokov\u00fa prev\u00e1dzku, \u010do poskytuje siln\u00fa v\u0161estrannos\u0165 a flexibiln\u00fa konfigur\u00e1ciu pre obtokov\u00e9 obvody r\u00f4znych d\u013a\u017eok.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Modul\u00e1rny dizajn podporuje opakovan\u00e9 sp\u00e1janie\/odp\u00e1janie, u\u013eah\u010duje pohodln\u00fa \u00fadr\u017ebu a zni\u017euje n\u00e1klady na invest\u00edcie do zariaden\u00ed pre obtokov\u00e9 prev\u00e1dzky.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Technick\u00e9 parametre<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Kateg\u00f3ria parametra<\/td><td>Predmet<\/td><td>Technick\u00e1 \u0161pecifik\u00e1cia<\/td><\/tr><tr><td>Menovit\u00e9 elektrick\u00e9 parametre<\/td><td>Prev\u00e1dzkov\u00e9 nap\u00e4tie syst\u00e9mu (Un)<\/td><td>10kV\/15kV<\/td><\/tr><tr><td><\/td><td>Menovit\u00e9 nap\u00e4tie (Ue)<\/td><td>15kV<\/td><\/tr><tr><td><\/td><td>Maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie (Um)<\/td><td>17,5 kV<\/td><\/tr><tr><td><\/td><td>Menovit\u00e1 frekvencia (fn)<\/td><td>50Hz\/60Hz<\/td><\/tr><tr><td><\/td><td>| Nap\u00e4tie pri sk\u00fa\u0161ke odolnosti vo\u010di sie\u0165ovej frekvencii<\/td><td>42kV\/5min (such\u00fd test), bez prierazu, bez preskoku<\/td><\/tr><tr><td><\/td><td>| Nap\u00e4tie pri odolnosti vo\u010di impulzn\u00e9mu prep\u00e4tiu<\/td><td>95kV (\u0161pi\u010dkov\u00e9), bez prierazu, bez preskoku<\/td><\/tr><tr><td><\/td><td>\u00darove\u0148 \u010diasto\u010dn\u00e9ho v\u00fdboja<\/td><td>\u226410pC (pri 1,5U\u2080)<\/td><\/tr><tr><td><\/td><td>Menovit\u00fd pr\u00fad<\/td><td>200A\/630A (volite\u013en\u00e9)<\/td><\/tr><tr><td><\/td><td>| Menovit\u00fd skratov\u00fd v\u00fddr\u017en\u00fd pr\u00fad<\/td><td>20kA\/2s, 25kA\/2s (volite\u013en\u00e9)<\/td><\/tr><tr><td><\/td><td>| Odpor kontaktu<\/td><td>\u226420\u03bc\u03a9<\/td><\/tr><tr><td>Kon\u0161truk\u010dn\u00e9 a materi\u00e1lov\u00e9 parametre<\/td><td>Prim\u00e1rny materi\u00e1l<\/td><td>Pokovovan\u00fd c\u00ednom\/postriebren\u00e1 me\u010f (vodiv\u00e9 jadro), vysokopevnostn\u00fd izola\u010dn\u00fd materi\u00e1l (puzdro), nehrdzavej\u00faca oce\u013e (uzamykac\u00ed mechanizmus\/pr\u00edruba)<\/td><\/tr><tr><td><\/td><td>Hodnotenie stup\u0148a ochrany<\/td><td>IP67<\/td><\/tr><tr><td><\/td><td>| Rozhranie \u0161tandard<\/td><td>15kV r\u00fdchlospojky\/rozpojky na oboch koncoch, stredovo upevnen\u00e1 pevn\u00e1 pr\u00edruba, v s\u00falade s priemyseln\u00fdmi normami pre zariadenia na obch\u00e1dzkov\u00fa prev\u00e1dzku<\/td><\/tr><tr><td><\/td><td>| Kompatibiln\u00e9 vybavenie<\/td><td>10kV\/15kV bypass k\u00e1ble, bypass sp\u00edna\u010de, prep\u00e1jacie k\u00e1ble a in\u00e9 r\u00fdchloup\u00ednacie bypass prev\u00e1dzkov\u00e9 zariadenia<\/td><\/tr><tr><td><\/td><td>| Pr\u00edloha \u0161pecifik\u00e1cia<\/td><td>\u0160tandardn\u00e1 mont\u00e1\u017ena pr\u00edruba (kompatibiln\u00e1 s univerz\u00e1lnym dr\u017eiakom\/mont\u00e1\u017enymi otvormi zariadenia; mo\u017enos\u0165 prisp\u00f4sobenia)<\/td><\/tr><tr><td>Environment\u00e1lne parametre<\/td><td>Pou\u017eite\u013en\u00e1 v\u00fd\u0161ka<\/td><td>\u22642000 m (dostupn\u00e9 prisp\u00f4sobenie pre vysok\u00fa nadmorsk\u00fa v\u00fd\u0161ku)<\/td><\/tr><tr><td><\/td><td>| Okolit\u00e1 teplota<\/td><td>-40 \u00b0C a\u017e +90 \u00b0C (prev\u00e1dzkov\u00e1), -40 \u00b0C a\u017e +70 \u00b0C (skladovacia)<\/td><\/tr><tr><td><\/td><td>Relat\u00edvna vlhkos\u0165<\/td><td>\u2264100% (nekondenzuj\u00faca)<\/td><\/tr><tr><td><\/td><td>| Seizmick\u00e1 hodnota<\/td><td>8. ro\u010dn\u00edk<\/td><\/tr><tr><td>Platn\u00e9 normy<\/td><td><\/td><td>GB\/T 12706, DL\/T 1476 \u7535\u529b\u5b89\u5168\u5de5\u5668\u5177\u548c\u8bbe\u5907\u9884\u9632\u6027\u8bd5\u9a8c\u89c4\u7a0b, DL\/T 814 \u914d\u7535\u81ea\u52a8\u5316\u7ec8\u7aef<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Rozsah pou\u017eitia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pou\u017eite\u013en\u00e1 \u00farove\u0148 nap\u00e4tia: 10kV\/15kV strednonap\u00e4\u0165ov\u00e9 rozvodn\u00e9 syst\u00e9my striedav\u00e9ho pr\u00fadu; vhodn\u00e9 pre scen\u00e1re obch\u00e1dzkov\u00e9ho prev\u00e1dzky s maxim\u00e1lnym prev\u00e1dzkov\u00fdm nap\u00e4t\u00edm 17,5kV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pou\u017eite\u013en\u00e9 prev\u00e1dzkov\u00e9 scen\u00e1re:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pri r\u00fdchlom sp\u00e1jan\u00ed dvoch segmentov obtokov\u00e9ho k\u00e1bla po\u010das \u00fadr\u017eby a \u00faprav vedenia pod nap\u00e4t\u00edm na distribu\u010dn\u00fdch vedeniach a zariadeniach 10kV\/15kV, na pred\u013a\u017eenie d\u013a\u017eky obtokov\u00e9ho obvodu;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Obch\u00e1dzkov\u00e9 obvody vy\u017eaduj\u00face in\u0161tal\u00e1ciu s pevn\u00fdm dr\u017eiakom (napr. trvalo namontovan\u00e9 obch\u00e1dzkov\u00e9 rozhrania v k\u00e1blov\u00fdch tuneloch a distribu\u010dn\u00fdch miestnostiach), umo\u017e\u0148uj\u00face stabiln\u00fa in\u0161tal\u00e1ciu konektora;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9002\u7528\u4e8e\u57ce\u5e02\u914d\u7535\u7f51\u7535\u7f06\u7ebf\u8def\u3001\u5de5\u77ff\u4f01\u4e1a\u4f9b\u7535\u7cfb\u7edf\u3001\u65b0\u80fd\u6e90\uff08\u5149\u4f0f\/\u98ce\u7535\uff09\u5347\u538b\u7ad9\u914d\u7535\u8bbe\u5907\u7684\u5e26\u7535\u65c1\u8def\u4f5c\u4e1a\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Funk\u010dn\u00fd \u00fa\u010del: Poskytn\u00fa\u0165 izolovan\u00e9 oddelenie a vodiv\u00e9 prepojenie medzi dvoma segmentmi r\u00fdchlospojovac\u00edch obtokov\u00fdch k\u00e1blov, pri\u010dom s\u00fa\u010dasne umo\u017en\u00ed pevn\u00e9 upevnenie konektora pomocou pr\u00edrubovej kon\u0161trukcie, \u010d\u00edm pon\u00faka flexibiln\u00e9 a stabiln\u00e9 rie\u0161enie pre budovanie obvodov pri pr\u00e1cach na \u017eivo v distribu\u010dn\u00fdch syst\u00e9moch stredn\u00e9ho nap\u00e4tia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Prev\u00e1dzkov\u00e9 podmienky<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160tandardn\u00e9 prev\u00e1dzkov\u00e9 podmienky<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fd\u0161ka: \u22642000 m<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okolit\u00e1 teplota: -40 \u00b0C a\u017e +90 \u00b0C; prev\u00e1dzkov\u00e1 teplota zariadenia sp\u013a\u0148a pr\u00edslu\u0161n\u00e9 normy;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Relat\u00edvna vlhkos\u0165: \u2264100 % (nekondenzuj\u00faca);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podmienky prostredia: Bez koroz\u00edvnych plynov, hor\u013eav\u00fdch\/v\u00fdbu\u0161n\u00fdch m\u00e9di\u00ed a siln\u00fdch vibr\u00e1ci\u00ed alebo otrasov;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sp\u00f4sob in\u0161tal\u00e1cie: Mont\u00e1\u017e pomocou stredov\u00fdch pr\u00edrubov\u00fdch skrutiek na dr\u017eiak alebo kryt zariadenia; oba konce s\u00fa priamo spojen\u00e9 s pr\u00edslu\u0161n\u00fdmi rozhraniami obtokov\u00e9ho k\u00e1bla pomocou zas\u00favacieho pripojenia; je povolen\u00e1 horizont\u00e1lna alebo vertik\u00e1lna in\u0161tal\u00e1cia; priestor na in\u0161tal\u00e1ciu mus\u00ed umo\u017e\u0148ova\u0165 oper\u00e1cie sp\u00e1jania\/rozp\u00e1jania a po\u017eiadavky na mont\u00e1\u017e pr\u00edruby.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160peci\u00e1lne prev\u00e1dzkov\u00e9 podmienky (vy\u017eaduje sa prisp\u00f4sobenie)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nadmorsk\u00e1 v\u00fd\u0161ka presahuj\u00faca 2000 m;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Okolit\u00e1 teplota mimo rozsah -40 \u00b0C a\u017e +90 \u00b0C;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0164a\u017eko zne\u010disten\u00e9, slanou hmlou alebo chemicky koroz\u00edvne prostredia;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vysok\u00e9 vibr\u00e1cie alebo prev\u00e1dzkov\u00e9 podmienky s vysok\u00fdmi otrasmi;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nestandardn\u00e9 \u0161pecifik\u00e1cie rozhrania alebo nestandardn\u00e9 vzory mont\u00e1\u017enych otvorov pr\u00edruby;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0160peci\u00e1lne menovit\u00e9 pr\u00fady alebo po\u017eiadavky na pr\u00fadov\u00fa za\u0165a\u017eite\u013enos\u0165.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">In\u0161tal\u00e1cia a \u00fadr\u017eba<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na in\u0161tal\u00e1ciu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pred in\u0161tal\u00e1ciou skontrolujte v\u00fdrobok, \u010di neobsahuje praskliny, po\u0161kodenia a dutiny; overte, \u010di je izola\u010dn\u00fd kryt neporu\u0161en\u00fd. Skontrolujte, \u010di s\u00fa vodiv\u00fd stred, uzamykac\u00ed mechanizmus a pr\u00edruba bez hrdze, deform\u00e1ci\u00ed a \u010di uzamykac\u00ed mechanizmus funguje hladko a spo\u013eahlivo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vy\u010distite oba rozhrania konektorov a zodpovedaj\u00face povrchy rozhrania obtokov\u00e9ho k\u00e1bla, odstr\u00e1\u0148te mastnotu, prach a cudzie \u010dastice, aby ste zabezpe\u010dili such\u00e9 a \u010dist\u00e9 rozhrania. Vy\u010distite mont\u00e1\u017eny povrch dr\u017eiaka\/krytu zariadenia, aby ste zabezpe\u010dili jeho rovnos\u0165 a \u010distotu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aplikujte rovnomern\u00fa vrstvu \u0161pecializovan\u00e9ho silik\u00f3nov\u00e9ho maziva na vonkaj\u0161\u00ed povrch oboch rozhran\u00ed, aby ste zabr\u00e1nili po\u0161kodeniu izola\u010dnej vrstvy po\u010das in\u0161tal\u00e1cie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Produkt pripevnite k dr\u017eiaku\/krytu zariadenia cez pr\u00edrubu a dotiahnite skrutky na predp\u00edsan\u00fd kr\u00fatiaci moment. Bezpe\u010dne pripojte oba konce produktu k zodpovedaj\u00facim rozhraniam obtokov\u00e9ho k\u00e1bla, \u010d\u00edm zabezpe\u010d\u00edte \u00fapln\u00e9 zasunutie. Zapnite samozatv\u00e1rac\u00ed mechanizmus proti vysunutiu. Po dokon\u010den\u00ed skontrolujte, \u010di nedoch\u00e1dza k uvo\u013eneniu alebo nes\u00faladu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po in\u0161tal\u00e1cii vykonajte sk\u00fa\u0161ku izola\u010dn\u00e9ho odporu a sk\u00fa\u0161ku odolnosti vo\u010di nap\u00e4tiu v sie\u0165ovej frekvencii. Produkt m\u00f4\u017ee by\u0165 uveden\u00fd do prev\u00e1dzky a\u017e po \u00faspe\u0161nom absolvovan\u00ed t\u00fdchto sk\u00fa\u0161ok.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Po\u017eiadavky na \u00fadr\u017ebu<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pravidelne kontrolujte v\u00fdrobok, \u010di na \u0148om nie s\u00fa praskliny, po\u0161kodenia, stopy po vybit\u00ed a nahromaden\u00e9 ne\u010distoty; overte pevn\u00e9 spojenie na rozhraniach obtokov\u00fdch k\u00e1blov bez uvo\u013enenia; skontrolujte, \u010di skrutky pr\u00edrubov\u00e9ho upevnenia nevykazuj\u00fa \u017eiadne uvo\u013enenie alebo kor\u00f3ziu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pravidelne testujte izola\u010dn\u00fd odpor a odpor kontaktov, aby ste potvrdili, \u017ee v\u00fdkon sp\u013a\u0148a po\u017eiadavky, a aby ste v\u010das odhalili potenci\u00e1lne poruchy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vy\u010distite povrch a rozhrania produktu, odstr\u00e1\u0148te nahromaden\u00fd prach a ne\u010distoty; udr\u017eiavajte such\u00e9 a \u010dist\u00e9 izola\u010dn\u00e9 povrchy; vyh\u00fdbajte sa vystaveniu mastnote alebo chemick\u00fdm l\u00e1tkam, ktor\u00e9 m\u00f4\u017eu sp\u00f4sobi\u0165 kor\u00f3ziu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ak produkt vykazuje abnormality vr\u00e1tane praskl\u00edn, po\u0161kodenia, vybitia, prehrievania alebo odporu kontaktu presahuj\u00faceho stanoven\u00e9 limity, okam\u017eite ho vyra\u010fte z prev\u00e1dzky a vyme\u0148te. Prev\u00e1dzka chybnej jednotky je pr\u00edsne zak\u00e1zan\u00e1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Spojovanie a odpojovanie rozhran\u00ed sa mus\u00ed vykon\u00e1va\u0165 pomocou \u0161pecializovan\u00fdch izola\u010dn\u00fdch prev\u00e1dzkov\u00fdch n\u00e1strojov. Priama manu\u00e1lna manipul\u00e1cia s nap\u00e1jan\u00fdmi rozhraniami je pr\u00edsne zak\u00e1zan\u00e1. V\u0161etky oper\u00e1cie musia pr\u00edsne dodr\u017eiava\u0165 predpisy o bezpe\u010dnosti distrib\u00facie elektrickej energie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Opatrenia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobok mus\u00ed by\u0165 in\u0161talovan\u00fd, uveden\u00fd do prev\u00e1dzky a udr\u017eiavan\u00fd kvalifikovan\u00fdmi elektroin\u0161talat\u00e9rmi s certifik\u00e1ciou pre pr\u00e1ce na vysokonap\u00e4\u0165ov\u00fdch zariadeniach pod nap\u00e4t\u00edm. Prev\u00e1dzka neopr\u00e1vnen\u00fdmi osobami je pr\u00edsne zak\u00e1zan\u00e1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00fdrobok sa mus\u00ed pou\u017e\u00edva\u0165 so zariaden\u00edm na obtokov\u00fa prev\u00e1dzku a mont\u00e1\u017enymi dr\u017eiakmi zodpovedaj\u00facej \u0161pecifik\u00e1cie. Pou\u017e\u00edvanie nezhodn\u00fdch zariaden\u00ed s r\u00f4znymi nap\u00e4\u0165ov\u00fdmi alebo pr\u00fadov\u00fdmi hodnotami je pr\u00edsne zak\u00e1zan\u00e9, preto\u017ee to m\u00f4\u017ee vies\u0165 k zlyhaniu izol\u00e1cie a bezpe\u010dnostn\u00fdm rizik\u00e1m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Neopr\u00e1vnen\u00e1 demont\u00e1\u017e alebo \u00faprava produktu je zak\u00e1zan\u00e1 a sp\u00f4sob\u00ed stratu z\u00e1ruky a bezpe\u010dnostn\u00fdch z\u00e1ruk. Pou\u017e\u00edvanie ne\u0161pecializovan\u00fdch n\u00e1strojov na n\u00e1siln\u00fa in\u0161tal\u00e1ciu alebo demont\u00e1\u017e rozhran\u00ed alebo pr\u00edrub je pr\u00edsne zak\u00e1zan\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pri in\u0161tal\u00e1cii je potrebn\u00e9 d\u00f4sledne zabr\u00e1ni\u0165 po\u0161kodeniu izola\u010dn\u00e9ho povrchu. Silik\u00f3nov\u00e9 mazivo sa mus\u00ed nanies\u0165 rovnomerne, aby sa neohrozil izola\u010dn\u00fd v\u00fdkon a \u00fa\u010dinnos\u0165 tesnenia. Mont\u00e1\u017ene skrutky pr\u00edruby sa musia dotiahnu\u0165 na predp\u00edsan\u00fd kr\u00fatiaci moment, aby sa zabr\u00e1nilo uvo\u013eneniu, ktor\u00e9 by mohlo sp\u00f4sobi\u0165 vibr\u00e1cie konektora alebo rozpojenie rozhrania.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po\u010das skladovania mus\u00ed by\u0165 v\u00fdrobok uchov\u00e1van\u00fd v suchom, dobre vetranom a chladnom prostred\u00ed, mimo priameho slne\u010dn\u00e9ho \u017eiarenia, vysok\u00fdch tepl\u00f4t, vlhkosti a za\u0165a\u017eenia tlakom. Kontakt s ostr\u00fdmi predmetmi, ktor\u00e9 by mohli po\u0161kodi\u0165 izola\u010dn\u00fa vrstvu, je pr\u00edsne zak\u00e1zan\u00fd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pri prip\u00e1jan\u00ed alebo odp\u00e1jan\u00ed nap\u00e1jan\u00fdch rozhran\u00ed musia by\u0165 pr\u00edsne dodr\u017eiavan\u00e9 v\u0161etky bezpe\u010dnostn\u00e9 predpisy distrib\u00facie energie, musia by\u0165 zaveden\u00e9 primeran\u00e9 bezpe\u010dnostn\u00e9 ochrann\u00e9 opatrenia a nepr\u00edpustn\u00e9 oper\u00e1cie s\u00fa pr\u00edsne zak\u00e1zan\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ozna\u010denie modelu<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Identifik\u00e1tor modelu<\/th><th>Popis<\/th><\/tr><\/thead><tbody><tr><td>15kV<\/td><td>Pou\u017eite\u013en\u00e1 \u00farove\u0148 syst\u00e9mov\u00e9ho nap\u00e4tia; menovit\u00e9 nap\u00e4tie 15 kV; maxim\u00e1lne prev\u00e1dzkov\u00e9 nap\u00e4tie 17,5 kV<\/td><\/tr><tr><td>R\u00fdchloup\u00ednac\u00ed stredov\u00fd konektor s pr\u00edrubou<\/td><td>Pr\u00edrubov\u00fd r\u00fdchlospojkov\u00fd stredov\u00fd konektor na r\u00fdchle sp\u00e1janie a pevn\u00e9 upevnenie dvoch segmentov obtokov\u00e9ho k\u00e1bla<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Platn\u00e9 normy a certifik\u00e1cie<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Medzin\u00e1rodn\u00fd \u0161tandard: IEC 60840 Met\u00f3dy sk\u00fa\u0161ania a po\u017eiadavky na silov\u00e9 k\u00e1ble s extrudovanou izol\u00e1ciou a ich pr\u00edslu\u0161enstvo pre menovit\u00e9 nap\u00e4tia nad 30 kV (Um=36 kV) do 150 kV (Um=170 kV);<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fd\u5bb6\u6807\u51c6\uff1aGB\/T 12706 \u989d\u5b9a\u7535\u538b1kV\uff08Um=1.2kV\uff09\u81f335kV\uff08Um=40.5kV\uff09\u6324\u5851\u7edd\u7f18\u7535\u529b\u7535\u7f06\u53ca\u5176\u9644\u4ef6\uff1bDL\/T 1476 \u7535\u529b\u5b89\u5168\u5de5\u5177\u548c\u8bbe\u5907\u9884\u9632\u6027\u8bd5\u9a8c\u89c4\u7a0b\uff1bDL\/T 814 \u914d\u7535\u81ea\u52a8\u5316\u7ec8\u7aef\uff1b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ea7\u54c1\u5df2\u901a\u8fc7\u56fd\u5bb6\u7535\u529b\u5b89\u5168\u5de5\u5668\u5177\u8d28\u91cf\u76d1\u7763\u68c0\u9a8c\u4e2d\u5fc3\u578b\u5f0f\u8bd5\u9a8c\uff0c\u7b26\u5408\u56fd\u5bb6\u7535\u529b\u884c\u4e1a\u6807\u51c6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Odd\u00edl X. Popredajn\u00fd servis<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Z\u00e1ru\u010dn\u00e1 doba: 18 mesiacov od d\u00e1tumu v\u00fdroby, alebo 12 mesiacov od d\u00e1tumu uvedenia do prev\u00e1dzky, pod\u013ea toho, \u010do nastane sk\u00f4r;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Po\u010das z\u00e1ru\u010dnej doby s\u00fa v\u00fdrobn\u00e9 chyby sp\u00f4soben\u00e9 probl\u00e9mami s kvalitou bezplatne opraven\u00e9 alebo vymenen\u00e9;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Konzult\u00e1cie k technickej podpore, in\u0161tal\u00e1cii a prisp\u00f4sobeniu s\u00fa k dispoz\u00edcii (pre \u0161peci\u00e1lne \u0161pecifik\u00e1cie a prisp\u00f4sobenie \u0161peci\u00e1lnym prev\u00e1dzkov\u00fdm podmienkam).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pozn\u00e1mky k dokumentu<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u624b\u518c\u4e2d\u7684\u6280\u672f\u53c2\u6570\u57fa\u4e8e\u6807\u51c6\u64cd\u4f5c\u6761\u4ef6\u3002\u7279\u6b8a\u64cd\u4f5c\u6761\u4ef6\u9700\u8981\u6839\u636e\u5b9e\u9645\u8981\u6c42\u8fdb\u884c\u5b9a\u5236\u3002\u4ea7\u54c1\u6280\u672f\u534f\u8bae\u548c\u578b\u5f0f\u8bd5\u9a8c\u8bc1\u4e66\u4e3a\u6700\u7ec8\u4f9d\u636e\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pr\u00edloha: N\u00e1kres obrysu produktu<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"621\" height=\"552\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/15kV-Quick-release-intermediate-connectorwith-flange-3.png\" alt=\"15kV Quick release intermediate connector with flange\" class=\"wp-image-411\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/15kV-Quick-release-intermediate-connectorwith-flange-3.png 621w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/15kV-Quick-release-intermediate-connectorwith-flange-3-300x267.png 300w\" sizes=\"(max-width: 621px) 100vw, 621px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The 15kV Quick Release Intermediate Connector (with Flange, 15kV Quick release intermediate connector with flange) is a dedicated [&hellip;]<\/p>\n","protected":false},"featured_media":409,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[13],"class_list":["post-408","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-quick-plug-series"],"acf":{"products_imagines":[409,410,411],"short_describe":"","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products\/408","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/411"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/410"},{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/409"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media\/409"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/media?parent=408"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/sk\/wp-json\/wp\/v2\/product_category?post=408"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}