产品概述
TG1-10Q/210 (125×125) 套管 这是一种室内高压环氧树脂穿墙套管,采用 APG(自动压力凝胶)工艺一体化制造。
它适用于10千伏中压配电系统,用于导电母线穿过的地方。 switchgear 隔板、墙壁或其他接地结构。该产品提供电气绝缘、机械支撑和安全的母线连接。
It is widely used in withdrawable switchgear, ring main units, and other complete power distribution equipment.
产品特点
Excellent Insulation Performance
The bushing is manufactured from high-purity epoxy resin as a one-piece structure without internal bubbles or visible defects.
It provides excellent dielectric strength and corona resistance and can withstand the long-term operating voltage of a 10 kV system, meeting the insulation requirements of medium-voltage electrical equipment.
高机械强度
The rigid integrated structure provides reliable resistance to impact, vibration, cracking, and deformation.
It can withstand busbar installation stress and mechanical loads generated during equipment operation.
强大的环境适应性
The product offers good resistance to contamination, moisture, and ageing. It can operate reliably for long periods under normal indoor conditions.
No special maintenance is required. Periodic cleaning of surface contamination is normally sufficient.
Advanced Manufacturing and Structural Design
The APG pressure gelation process produces a dense internal structure and stable product performance.
The shed structure increases the creepage distance and improves the insulation margin. The square flange is designed to match standard switchgear mounting openings, making installation convenient and reliable.
Safe and Reliable
The flame-retardant material does not support flame propagation or release harmful gases under normal specified conditions.
The product complies with applicable fire-safety requirements for electrical equipment and has passed recognized testing and inspection procedures.
技术规格
| 参数 | 规格 | 描述 |
|---|---|---|
| 模型 | TG1-10Q/210 (125×125) | Standard industry model |
| 额定电压 | 10千伏 | Maximum operating voltage: 12 kV |
| 额定频率 | 50 赫兹 | Compatible with 15–60 Hz systems |
| 法兰尺寸 | 125 × 125 mm | Square mounting flange for standard switchgear openings |
| 总高度 | 210 mm | Total axial length |
| Applicable Busbar | Copper busbar up to 102 × 12 mm | Inner opening suitable for corresponding busbar sizes |
| 绝缘材料 | Epoxy resin | Manufactured using the APG process; standard red insulating body |
| 工频耐压 | 42 kV for 1 minute | Rated power-frequency withstand level |
| 雷电冲击耐受电压 | 75 kV peak | Standard lightning impulse withstand level |
| 爬电距离 | ≥210 mm | Meets the insulation requirements of 10 kV systems |
| 热等级 | F类 | Maximum long-term temperature: 155°C; short-term resistance up to 300°C |
| 适用标准 | GB/T 12944.1 and GB/T 12944.2 | National standards for high-voltage wall bushings |
应用
Applicable Equipment and Systems
The product is suitable for indoor three-phase AC power distribution systems rated at 10 kV and below with a frequency of 50 Hz, including:
- Withdrawable switchgear
- 环网柜
- KYN28 high-voltage switchgear
- Substation distribution equipment
- Power distribution room equipment
- Other complete medium-voltage switchgear assemblies
- Applications where conductive components pass through partitions, walls, or grounded structures
兼容母线
The bushing is suitable for copper or aluminium busbars with dimensions up to 102 × 12 mm.
The busbar passes through the inner opening to provide a continuous electrical connection while maintaining insulation from surrounding grounded structures.
适用行业
The product is suitable for power distribution systems in:
- Electric power facilities
- Industrial and mining enterprises
- Rail transit systems
- Renewable energy facilities
- Commercial and infrastructure projects
操作条件
正常运行条件
- Ambient temperature: -25°C to +40°C
- Daily average ambient temperature: no more than +35°C
- Installation altitude: no more than 1,000 m
- Altitude correction is required according to applicable standards for installations above 1,000 m
- Relative humidity: no more than 85% at +20°C
- Condensation is not permitted
- The environment should be free from gases, vapours, dust, explosive substances, and corrosive media that may seriously affect insulation performance
- Severe vibration and mechanical impact should be avoided
- Indoor vertical or horizontal installation
- The mounting flange should be secured to the switchgear partition
Special Operating Conditions
Customized products are required for:
- High-altitude environments
- High-temperature and high-humidity environments
- Heavily polluted environments
- Extremely high or low temperatures
- Applications requiring special corrosion protection
- Applications requiring explosion-resistant configurations
安装与维护
安装要求
- Pre-installation inspection: Confirm that the bushing is free from cracks, damage, bubbles, and other visible defects. Check that the flange is flat and that all dimensions meet the installation requirements.
- Mounting opening: The switchgear partition opening must match the 125 × 125 mm flange dimensions, with suitable mounting holes reserved for the fastening bolts.
- Installation and fastening: Insert the bushing through the partition and secure the flange with bolts. Ensure that the flange fits closely against the mounting surface without looseness.
- Busbar installation: Pass the busbar through the inner opening and maintain an even clearance between the busbar and the inner wall. Avoid localized mechanical stress.
- Electrical clearance: After installation, ensure that the safety distances between the live components at both ends of the bushing and grounded structures meet the requirements of the 10 kV system.
维护要求
- Routine inspection: Regularly inspect the bushing for surface contamination, discharge marks, cracks, and loose flange connections.
- Cleaning: Clean the insulating surface with a dry, soft cloth. Do not use corrosive cleaning agents that may damage the insulation.
- Periodic testing: Conduct insulation resistance and power-frequency withstand voltage tests according to the preventive testing requirements for electrical equipment.
- Replacement conditions: Replace the bushing immediately if insulation breakdown, severe surface discharge, mechanical cracking, or other serious damage is found.
注意事项
- Do not use the product above its rated voltage or outside the specified environmental conditions, as this may cause insulation failure.
- Installation and maintenance must be carried out with the equipment de-energized and in strict accordance with high-voltage electrical safety procedures.
- Avoid impact, compression, and dropping during transportation and storage to prevent damage to the insulating body.
- Store the product in a dry and ventilated environment.
- The product is intended for indoor use only and must not be installed directly in exposed outdoor environments. A customized outdoor version is required for outdoor applications.
- Do not strike, force, or excessively compress the bushing during installation, as this may cause hidden internal cracks.
质量保证
The product complies with applicable national standards and undergoes complete factory inspection before delivery. A quality inspection report can be provided.
The warranty period is subject to the terms agreed in the contract. After-sales support is provided for product quality issues occurring under normal operating conditions, excluding damage caused by improper handling, unauthorized modification, or operation outside the specified conditions.