{"id":643,"date":"2026-01-26T06:02:21","date_gmt":"2026-01-26T06:02:21","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=643"},"modified":"2026-09-16T01:49:27","modified_gmt":"2026-09-16T01:49:27","slug":"wb-35q-184-3av3-bending-plate","status":"publish","type":"products","link":"https:\/\/yieou.com\/zh\/product\/wb-35q-184-3av3-bending-plate\/","title":{"rendered":"WB-35Q\/184 3AV3 \u5f2f\u66f2\u677f"},"content":{"rendered":"<h3 class=\"wp-block-heading\">\u4ea7\u54c1\u6982\u8ff0<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/zh\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">WB-35Q\/184 3AV3 \u7edd\u7f18\u5f2f\u66f2\u677f<\/a> \u662f\u4e00\u79cd\u7edd\u7f18\u652f\u6491\u548c\u4fdd\u62a4\u7ec4\u4ef6\uff0c\u4e13\u4e3a\u9ad8\u538b\u7535\u6c14\u8bbe\u5907\u8bbe\u8ba1\u3002\u91c7\u7528\u963b\u71c3\u7edd\u7f18\u590d\u5408\u6750\u6599\u4e00\u4f53\u6210\u578b\u5236\u9020\uff0c\u63d0\u4f9b\u53ef\u9760\u7684\u673a\u68b0\u5f3a\u5ea6\u548c\u7535\u6c14\u7edd\u7f18\u6027\u80fd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8be5\u4ea7\u54c1\u4e3b\u8981\u7528\u4e8e <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a>\u65ad\u8def\u5668\u9762\u677f\u4ee5\u53ca\u76f8\u5173\u7684\u9ad9\u538b\u8bbe\u5907\uff0c\u4ee5\u652f\u6491\u6bcd\u7ebf\u548c\u89e6\u70b9\u7cfb\u7edf\uff0c\u540c\u65f6\u63d0\u4f9b\u7edd\u7f18\u548c\u706d\u5f27\u4fdd\u62a4\u3002\u5176\u7a33\u5b9a\u7684\u7ed3\u6784\u6709\u52a9\u4e8e\u63d0\u9ad8\u9ad9\u538b\u914d\u7535\u7cfb\u7edf\u7684\u8fd0\u884c\u5b89\u5168\u6027\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u6280\u672f\u89c4\u683c<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u53c2\u6570<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead><tbody><tr><td>\u4ea7\u54c1\u578b\u53f7<\/td><td>WB-35Q\/184 3AV3<\/td><\/tr><tr><td>\u603b\u9ad8\u5ea6<\/td><td>540 \u6beb\u7c73<\/td><\/tr><tr><td>\u5b89\u88c5\u677f\u957f\u5ea6<\/td><td>582 \u6beb\u7c73<\/td><\/tr><tr><td>\u5b89\u88c5\u677f\u5bbd\u5ea6<\/td><td>120\u6beb\u7c73<\/td><\/tr><tr><td>\u5b89\u88c5\u677f\u539a\u5ea6<\/td><td>10 \u6beb\u7c73<\/td><\/tr><tr><td>\u5b89\u88c5\u5b54\u89c4\u683c<\/td><td>4 \u00d7 M10, 25 mm hole depth<\/td><\/tr><tr><td>Mounting Hole Centre Distance<\/td><td>533 mm longitudinally and 60 mm transversely<\/td><\/tr><tr><td>Side Projection<\/td><td>52 \u6beb\u7c73<\/td><\/tr><tr><td>\u8868\u9762\u7c97\u7cd9\u5ea6<\/td><td>Ra 0.2 \u03bcm on critical contact surfaces<\/td><\/tr><tr><td>\u5e76\u884c\u5bb9\u5dee<\/td><td>0.15 mm on critical mounting surfaces<\/td><\/tr><tr><td>\u6750\u6599<\/td><td>\u963b\u71c3\u7edd\u7f18\u590d\u5408\u6750\u6599<\/td><\/tr><tr><td>Flame-Retardant Performance<\/td><td>Complies with applicable industry flame-retardant requirements<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u4ea7\u54c1\u7279\u70b9<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">Reliable Electrical Insulation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The product is manufactured from high-insulation, flame-retardant material that effectively separates live conductors from surrounding components. It helps reduce the risk of electrical tracking, short circuits, and insulation failure, improving the safety of both equipment and personnel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u9ad8\u673a\u68b0\u5f3a\u5ea6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The one-piece moulded structure offers strong resistance to bending, impact, and mechanical deformation. It can provide stable support for busbars, contact systems, and other internal components during long-term equipment operation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5b89\u88c5\u4fbf\u6377<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Four standard M10 mounting holes are integrated into the structure. The standardized mounting dimensions allow the product to be installed efficiently in compatible high-voltage switchgear, circuit breaker cabinets, and related equipment frames.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Flame-Retardant Construction<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The product is manufactured from flame-retardant insulating material and includes the corresponding flame-retardant marking. Under abnormal heating or short-circuit conditions, the material helps limit flame propagation and supports the fire-safety requirements of electrical equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Controlled Dimensional Accuracy<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Critical contact and mounting surfaces are manufactured with controlled surface roughness, parallelism, and dimensional tolerances. This helps maintain accurate positioning, stable contact, and reliable assembly while reducing vibration and mechanical wear during operation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Strong Environmental Resistance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The insulating composite material provides good resistance to ageing, oil contamination, electrical corona, and common indoor environmental conditions. It is suitable for long-term use in indoor high-voltage electrical equipment.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5e94\u7528<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The WB-35Q\/184 3AV3 Insulating Bending Plate is suitable for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>35 kV high-voltage switchgear<\/li>\n\n\n\n<li>High-voltage circuit breaker cabinets<\/li>\n\n\n\n<li>Busbar insulation and mechanical support<\/li>\n\n\n\n<li>Contact system insulation and support<\/li>\n\n\n\n<li>Arc-separation and electrical isolation structures<\/li>\n\n\n\n<li>Indoor AC metal-enclosed switchgear<\/li>\n\n\n\n<li>\u73af\u7f51\u67dc<\/li>\n\n\n\n<li>3AV3 series compatible cabinet structures<\/li>\n\n\n\n<li>High-voltage power distribution equipment<\/li>\n\n\n\n<li>Electrical systems requiring insulation between live conductors and equipment frames<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The product can be used as an insulating support and protective barrier in applications where live conductors require both mechanical positioning and electrical separation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u64cd\u4f5c\u6761\u4ef6<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">\u73af\u5883\u6e29\u5ea6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The recommended operating temperature range is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>-40\u00b0C \u81f3 +85\u00b0C<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The product is intended primarily for indoor high-voltage electrical equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Installation Altitude<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The standard installation altitude should not exceed:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2,000 metres above sea level<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For installations above 2,000 metres, insulation coordination, equipment derating, or a customized product design may be required.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u76f8\u5bf9\u6e7f\u5ea6<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Daily average relative humidity: no more than 95%<\/li>\n\n\n\n<li>Monthly average relative humidity: no more than 90%<\/li>\n\n\n\n<li>Operating conditions should be non-condensing<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Prolonged exposure to condensation or excessive moisture should be avoided.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pollution Conditions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The product is suitable for indoor environments with pollution level 2 or below.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avoid installation in locations exposed to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Severe dust accumulation<\/li>\n\n\n\n<li>Corrosive gases<\/li>\n\n\n\n<li>Salt spray<\/li>\n\n\n\n<li>Conductive contamination<\/li>\n\n\n\n<li>Flammable or explosive substances<\/li>\n\n\n\n<li>Continuous water exposure<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For high-pollution or special operating environments, customized insulation measures may be required.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5b89\u88c5\u8981\u6c42<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The mounting surface must be flat, clean, and free from dust, oil, metal particles, burrs, and other contaminants.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ensure that the product fits closely against the equipment frame without excessive installation stress. Forced installation or misaligned mounting holes may damage the insulating structure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use suitable standard bolts and tighten them according to the specified torque requirements. Excessive tightening may crack or deform the insulating material, while insufficient tightening may cause loosening or vibration during operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">After installation, check the electrical clearance between live components and the insulating plate. The completed assembly should meet the applicable safety requirements for 35 kV switchgear, including the relevant requirements of GB\/T 3906.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The product structure and mounting holes must not be modified without technical approval.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Inspection and Maintenance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Inspect the product regularly for signs of:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Surface cracks<\/li>\n\n\n\n<li>Mechanical deformation<\/li>\n\n\n\n<li>Electrical tracking<\/li>\n\n\n\n<li>Carbonization<\/li>\n\n\n\n<li>Arc erosion<\/li>\n\n\n\n<li>Surface burning<\/li>\n\n\n\n<li>Severe ageing<\/li>\n\n\n\n<li>Loose mounting hardware<\/li>\n\n\n\n<li>Contamination or moisture accumulation<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Replace the product immediately if cracking, serious erosion, deformation, carbonization, or significant insulation deterioration is found.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When cleaning the product, use a clean, dry, soft cloth. Do not use abrasive tools, corrosive solvents, or cleaning agents that may damage the insulating surface.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The inspection frequency should be determined according to the equipment operating conditions, environmental pollution level, and maintenance schedule.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5b89\u5168\u6ce8\u610f\u4e8b\u9879<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This product is an insulating component and must not be installed, removed, adjusted, or inspected while the equipment is energized.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before carrying out installation or maintenance work:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Disconnect the equipment from all power sources<\/li>\n\n\n\n<li>Confirm that the circuit is fully de-energized<\/li>\n\n\n\n<li>Discharge any residual voltage<\/li>\n\n\n\n<li>Apply the required grounding measures<\/li>\n\n\n\n<li>Follow all applicable high-voltage safety procedures<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Protect the product from impact, compression, dropping, and improper stacking during transportation and storage. Mechanical damage may reduce both its structural strength and insulation performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do not drill additional holes, grind the surface, cut the structure, or otherwise modify the product without authorization.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For applications involving high altitude, severe pollution, high humidity, or other special operating conditions, confirm the required technical configuration with the supplier before installation.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"374\" height=\"371\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/WB-35Q-184-3AV3-Bending-Plate.png\" alt=\"WB-35Q-184-3AV3-\u5f2f\u66f2\u677f\" class=\"wp-image-644\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/WB-35Q-184-3AV3-Bending-Plate.png 374w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/WB-35Q-184-3AV3-Bending-Plate-300x298.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/WB-35Q-184-3AV3-Bending-Plate-150x150.png 150w\" sizes=\"(max-width: 374px) 100vw, 374px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The WB-35Q\/184 3AV3 Insulating Bending Plate is an insulating support and protective component designed for high-voltage electrical equipment. [&hellip;]<\/p>\n","protected":false},"featured_media":644,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[34],"class_list":["post-643","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-insulation-components-series"],"acf":{"products_imagines":[644,645],"short_describe":"<p><span style=\"color: #334155; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif; font-size: 16px; white-space: pre-wrap;\">The WB-35Q\/184 3AV3 Insulating Bending Plate is an insulating support and protective component designed for high-voltage electrical equipment.<\/span><\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/products\/643","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media\/645"},{"embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media\/644"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media\/644"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media?parent=643"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/product_category?post=643"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}