{"id":741,"date":"2026-01-26T07:34:59","date_gmt":"2026-01-26T07:34:59","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=741"},"modified":"2026-09-09T07:37:43","modified_gmt":"2026-09-09T07:37:43","slug":"35kv-130-320-sensor","status":"publish","type":"products","link":"https:\/\/yieou.com\/zh\/product\/35kv-130-320-sensor\/","title":{"rendered":"35kV-130-320 High-Voltage Sensor"},"content":{"rendered":"<h2 class=\"wp-block-heading\">\u4ea7\u54c1\u6982\u8ff0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/zh\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">The 35kV-130\u00d7320 High-Voltage Sensor<\/a>, corresponding to the model <strong>CG5-35Q\/130\u00d7320<\/strong>, is an epoxy resin cast capacitive <a href=\"https:\/\/en.wikipedia.org\/wiki\/Sensor\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Sensor\" target=\"_blank\" rel=\"noopener\">sensor<\/a> designed for 35 kV indoor high-voltage electrical systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The product integrates three core functions: voltage presence indication, electrical interlocking against incorrect operation, and post-insulator support. It is widely used in high-voltage switchgear, ring main units, and other complete electrical equipment and is a key component for ensuring the safe operation of power distribution systems.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u4ea7\u54c1\u7279\u70b9<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Excellent Insulation Performance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The sensor is manufactured from high-quality epoxy resin using an integrated vacuum-casting process. Its optimized shed structure increases the creepage distance and improves electric field distribution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The product provides high dielectric strength, arc resistance, corona resistance, and a low partial discharge level of no more than 5 pC. It can withstand system overvoltage and helps reduce the risk of electrical flashover.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u96c6\u6210\u7ed3\u6784\u8bbe\u8ba1<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The capacitive voltage-sensing rod and <a href=\"https:\/\/yieou.com\/zh\/products\/\">\u67f1\u5f0f\u7edd\u7f18\u5b50<\/a> are integrated into a single structure. The sensor can replace a conventional <a href=\"https:\/\/yieou.com\/zh\/products\/\">\u67f1\u5f0f\u7edd\u7f18\u5b50<\/a> in compatible applications without requiring an additional insulating support.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This integrated design simplifies the internal switchgear structure, reduces installation space, and provides high mechanical strength with reliable resistance to vibration and impact.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Reliable Interlocking Protection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The sensor extracts a voltage signal from the high-voltage circuit and supplies it to the voltage presence indicator and electromagnetic interlocking system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It can provide forced interlocking for switchgear operating handles, access doors, mesh doors, and earthing switches. As long as the high-voltage circuit remains energized, the interlocking function remains active, helping prevent accidents caused by incorrect operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The indication and interlocking circuits operate independently and do not interfere with each other.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5f3a\u5927\u7684\u73af\u5883\u9002\u5e94\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The epoxy resin material provides reliable resistance to ageing, heat and humidity, contamination, and electrical tracking.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Its hydrophobic insulating surface supports stable operation across a temperature range of -35\u00b0C to +40\u00b0C, making the sensor suitable for most indoor high-voltage distribution environments.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u514d\u7ef4\u62a4\u8bbe\u8ba1<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The fully sealed cast structure contains no exposed live parts and provides reliable protection against moisture, dust, and condensation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Under normal operating conditions, the sensor requires minimal routine maintenance and offers a long service life.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6280\u672f\u89c4\u683c<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u53c2\u6570<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead><tbody><tr><td>\u989d\u5b9a\u7535\u538b<\/td><td>35\u5343\u4f0f<\/td><\/tr><tr><td>Maximum System Voltage<\/td><td>40.5\u5343\u4f0f<\/td><\/tr><tr><td>\u989d\u5b9a\u9891\u7387<\/td><td>50 \u8d6b\u5179<\/td><\/tr><tr><td>\u5c3a\u5bf8<\/td><td>130 mm diameter \u00d7 320 mm overall height<\/td><\/tr><tr><td>\u989d\u5b9a\u7edd\u7f18\u6c34\u5e73<\/td><td>40.5\/95\/200 kV<\/td><\/tr><tr><td>\u5de5\u9891\u8010\u538b<\/td><td>95 kV for 1 minute under dry conditions<\/td><\/tr><tr><td>\u96f7\u7535\u51b2\u51fb\u8010\u53d7\u7535\u538b<\/td><td>200 kV peak, 1.2\/50 \u03bcs<\/td><\/tr><tr><td>\u5c40\u90e8\u653e\u7535<\/td><td>\u22645 pC at 1.1 Um\/\u221a3<\/td><\/tr><tr><td>\u722c\u7535\u8ddd\u79bb<\/td><td>\u22651,050 mm, meeting the indoor pollution requirements of 35 kV systems<\/td><\/tr><tr><td>Capacitive Voltage Division Ratio<\/td><td>Customizable to match standard voltage presence indicators; typical value: 35 kV\/100 V<\/td><\/tr><tr><td>Rated Bending Load<\/td><td>\u22658\u5343\u725b<\/td><\/tr><tr><td>Tensile Load Performance<\/td><td>Withstands the rated tensile load for 1 minute without damage<\/td><\/tr><tr><td>\u7edd\u7f18\u6750\u6599<\/td><td>Epoxy resin<\/td><\/tr><tr><td>\u9002\u7528\u6807\u51c6<\/td><td>GB\/T 25038-2010, DL\/T 538-2006, IEC 60270<\/td><\/tr><tr><td>Material Standard Reference<\/td><td>GB\/T 20840.1-2010<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u5e94\u7528<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Applicable Equipment<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The sensor is suitable for indoor high-voltage electrical equipment with a rated voltage of 35 kV, a maximum system voltage of 40.5 kV, and a rated frequency of 50 Hz, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>35 kV high-voltage switchgear, including KYN61-40.5<\/li>\n\n\n\n<li>\u73af\u7f51\u67dc<\/li>\n\n\n\n<li>European-type and American-type box substations<\/li>\n\n\n\n<li>Disconnectors<\/li>\n\n\n\n<li>Earthing switches<\/li>\n\n\n\n<li>Circuit breakers<\/li>\n\n\n\n<li>Other indoor high-voltage distribution equipment requiring voltage indication and electrical interlocking<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e3b\u8981\u529f\u80fd<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Real-time indication of the energized status of high-voltage circuits<\/li>\n\n\n\n<li>Voltage signal transmission to a high-voltage presence indicator<\/li>\n\n\n\n<li>Forced interlocking of switchgear access doors and operating handles<\/li>\n\n\n\n<li>Prevention of incorrect operation while the circuit is energized<\/li>\n\n\n\n<li>Insulating and mechanical support for high-voltage conductors<\/li>\n\n\n\n<li>Capacitive voltage division and auxiliary power extraction<\/li>\n\n\n\n<li>Optional support for partial discharge monitoring applications<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u64cd\u4f5c\u6761\u4ef6<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u73af\u5883\u6761\u4ef6<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ambient temperature: -25\u00b0C to +40\u00b0C<\/li>\n\n\n\n<li>Minimum temperature for special regions: -35\u00b0C<\/li>\n\n\n\n<li>Installation altitude: no more than 1,000 m<\/li>\n\n\n\n<li>For installations above 1,000 m, insulation correction must be carried out according to GB\/T 11022<\/li>\n\n\n\n<li>Daily average relative humidity: no more than 95% RH<\/li>\n\n\n\n<li>Monthly average relative humidity: no more than 90% RH<\/li>\n\n\n\n<li>Daily average water vapour pressure: no more than 2.2 kPa<\/li>\n\n\n\n<li>Monthly average water vapour pressure: no more than 1.8 kPa<\/li>\n\n\n\n<li>The installation environment should be free from severe contamination, condensation, and excessive dust<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u5b89\u88c5\u6761\u4ef6<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Installation location: indoor<\/li>\n\n\n\n<li>The environment must be free from flammable or explosive substances, corrosive gases, and severe vibration<\/li>\n\n\n\n<li>Installation orientation: vertical<\/li>\n\n\n\n<li>The high-voltage terminal must be connected to the high-voltage busbar or conductor<\/li>\n\n\n\n<li>The low-voltage terminal must be connected to the voltage presence indicator<\/li>\n\n\n\n<li>The grounding terminal at the bottom of the sensor must be reliably grounded<\/li>\n\n\n\n<li>Grounding resistance: \u22644 \u03a9<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Prohibited Applications<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The standard product must not be used in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Exposed outdoor environments<\/li>\n\n\n\n<li>Locations subject to strong ultraviolet radiation<\/li>\n\n\n\n<li>Environments with severe chemical corrosion or salt spray<\/li>\n\n\n\n<li>Locations containing flammable or explosive gases<\/li>\n\n\n\n<li>Installations above 1,000 m without insulation correction<\/li>\n\n\n\n<li>Power systems exceeding the specified voltage or frequency range<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b89\u88c5\u4e0e\u7ef4\u62a4<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u5b89\u88c5\u8981\u6c42<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Before installation, inspect the sensor for cracks, damage, bubbles, deformation, or other visible defects. The insulating surface must be clean and free from contamination.<\/li>\n\n\n\n<li>Install the sensor vertically inside the switchgear.<\/li>\n\n\n\n<li>Connect the high-voltage terminal securely to the busbar or high-voltage conductor.<\/li>\n\n\n\n<li>Connect the low-voltage terminal to the corresponding terminal of the voltage presence indicator.<\/li>\n\n\n\n<li>Connect the grounding terminal at the bottom of the sensor reliably to the switchgear grounding busbar.<\/li>\n\n\n\n<li>The cross-sectional area of the grounding conductor must be at least 6 mm\u00b2.<\/li>\n\n\n\n<li>After installation, conduct an insulation withstand voltage test. The sensor may be put into operation only after the insulation performance has been confirmed as acceptable.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u7ef4\u62a4\u8981\u6c42<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Routine inspection:<\/strong> Check the sensor for surface damage, discharge marks, loose terminals, and abnormal temperature rise.<\/li>\n\n\n\n<li><strong>Periodic testing:<\/strong> Conduct insulation resistance and power-frequency withstand voltage tests every one to two years.<\/li>\n\n\n\n<li><strong>Cleaning:<\/strong> Clean the insulating surface using a dry, soft cloth. Do not use organic solvents that may damage the epoxy resin.<\/li>\n\n\n\n<li><strong>Fault handling:<\/strong> If partial discharge, insulation breakdown, cracking, or other serious abnormalities are detected, immediately de-energize the equipment and replace the sensor. Repair while energized is strictly prohibited.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u5305\u88c5\u3001\u8fd0\u8f93\u548c\u50a8\u5b58<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Packaging<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The product is packed in a moisture-resistant and shock-resistant carton with internal foam cushioning. A protective bag is placed over the product to prevent impact and moisture during transportation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Transportation<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Avoid severe vibration, overturning, rain exposure, and mechanical impact.<\/li>\n\n\n\n<li>Do not transport the product together with corrosive substances.<\/li>\n\n\n\n<li>Handle the packaged product carefully and keep it upright where required.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Storage<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Store the product indoors in a dry and well-ventilated environment free from corrosive gases.<\/li>\n\n\n\n<li>Storage temperature: -10\u00b0C to +40\u00b0C<\/li>\n\n\n\n<li>Relative humidity: \u226485% RH<\/li>\n\n\n\n<li>Keep the product away from heat sources, ignition sources, and direct sunlight.<\/li>\n\n\n\n<li>Do not stack more than three layers.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u6ce8\u610f\u4e8b\u9879<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>This product is a high-voltage electrical component. Installation and maintenance must be carried out by qualified electrical personnel in strict accordance with high-voltage safety procedures.<\/li>\n\n\n\n<li>Do not remove, repair, or touch the sensor while the equipment is energized.<\/li>\n\n\n\n<li>The rated voltage of the sensor is 35 kV. Operation above the specified voltage level is prohibited.<\/li>\n\n\n\n<li>During installation, ensure that the safety clearances between the sensor, switchgear enclosure, and adjacent live components comply with GB 3906.<\/li>\n\n\n\n<li>The product has passed the required type and routine tests before delivery. Unauthorized disassembly or modification is prohibited.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">\u6a21\u578b\u63cf\u8ff0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>35\u5343\u4f0f-130\u00d7320<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>35 kV:<\/strong> Rated voltage level<\/li>\n\n\n\n<li><strong>130:<\/strong> Diameter of the sensor body in millimetres<\/li>\n\n\n\n<li><strong>320:<\/strong> Overall sensor height in millimetres<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Corresponding standard model: CG5-35Q\/130\u00d7320<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"390\" height=\"390\" src=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/35kV-130-320-Sensor.png\" alt=\"35kv-130-320-sensor\" class=\"wp-image-742\" srcset=\"https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/35kV-130-320-Sensor.png 390w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/35kV-130-320-Sensor-300x300.png 300w, https:\/\/yieou.com\/wp-content\/uploads\/2026\/01\/35kV-130-320-Sensor-150x150.png 150w\" sizes=\"(max-width: 390px) 100vw, 390px\" \/><\/figure>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The 35kV-130\u00d7320 High-Voltage Sensor, corresponding to the model CG5-35Q\/130\u00d7320, is an epoxy resin cast capacitive sensor designed for [&hellip;]<\/p>\n","protected":false},"featured_media":742,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[34],"class_list":["post-741","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-insulation-components-series"],"acf":{"products_imagines":[742,743],"short_describe":"<p><span style=\"color: #334155; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif; font-size: 16px; white-space: pre-wrap;\">The 35kV-130&times;320 High-Voltage Sensor, corresponding to the model <\/span><strong style=\"max-width: none; margin-right: auto; margin-left: auto; color: #334155; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif; font-size: 16px; white-space: pre-wrap;\">CG5-35Q\/130&times;320<\/strong><span style=\"color: #334155; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif; font-size: 16px; white-space: pre-wrap;\">, is an epoxy resin cast capacitive sensor designed for 35 kV indoor high-voltage electrical systems.<\/span><\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/products\/741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media\/743"},{"embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media\/742"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media\/742"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media?parent=741"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/product_category?post=741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}