{"id":770,"date":"2026-01-26T08:11:44","date_gmt":"2026-01-26T08:11:44","guid":{"rendered":"http:\/\/yieou.com\/?post_type=products&#038;p=770"},"modified":"2026-09-10T07:31:59","modified_gmt":"2026-09-10T07:31:59","slug":"voltage-presence-indicating-device-sensor-2","status":"publish","type":"products","link":"https:\/\/yieou.com\/zh\/product\/voltage-presence-indicating-device-sensor-2\/","title":{"rendered":"CG5-10Q\/95\u00d7130 (135, 140, 145, 150, 170) \u5ba4\u5185\u9ad8\u538b\u5e26\u7535\u663e\u793a\u5668\u4f20\u611f\u5668"},"content":{"rendered":"<h2 class=\"wp-block-heading\">\u4ea7\u54c1\u6982\u8ff0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/yieou.com\/zh\/products\/\" data-type=\"link\" data-id=\"https:\/\/yieou.com\/products\/\">CG5-10Q\u7cfb\u5217\u6237\u5185\u9ad8\u538b\u5e26\u7535\u663e\u793a\u5668\u4f20\u611f\u5668<\/a>\uff0c\u4ee5\u4e0b\u7b80\u79f0\u201c\u4f20\u611f\u5668\u201d\uff0c\u662f\u4e13\u4e3a10\u5343\u4f0f\u53ca\u4ee5\u4e0b\u6237\u5185\u9ad8\u538b\u7535\u6c14\u7cfb\u7edf\u8bbe\u8ba1\u7684\u4e00\u6b3e\u5173\u952e\u914d\u5957\u90e8\u4ef6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When used with a high-voltage presence indicator, the sensor detects the energized status of a high-voltage circuit in real time and transmits the signal to the indicator for clear visual display. This helps prevent electrical misoperation and protects both maintenance personnel and high-voltage distribution equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8be5\u4ea7\u54c1\u91c7\u7528\u73af\u6c27\u6811\u8102\u6574\u4f53\u6d47\u6ce8\u5de5\u827a\u5236\u9020\uff0c\u5177\u6709\u4f18\u826f\u7684\u7535\u6c14\u7edd\u7f18\u6027\u3001\u673a\u68b0\u5f3a\u5ea6\u548c\u73af\u5883\u9002\u5e94\u6027\uff0c\u5e7f\u6cdb\u5e94\u7528\u4e8e\u5ba4\u5185\u9ad8\u538b <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\" target=\"_blank\" rel=\"noopener\">switchgear<\/a>\u73af\u7f51\u67dc\u3001\u7bb1\u5f0f\u53d8\u7535\u7ad9\u53ca\u5176\u4ed6\u914d\u7535\u8bbe\u5907\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u4ea7\u54c1\u7279\u70b9<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Excellent Insulation Performance<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Manufactured through integrated vacuum casting using high-quality epoxy resin, with no bubbles or cracks.<\/li>\n\n\n\n<li>Provides high dielectric strength and can withstand the long-term operating voltage of a 10 kV system.<\/li>\n\n\n\n<li>Meets the applicable insulation requirements of GB\/T 1985 and related standards.<\/li>\n\n\n\n<li>The optimized shed structure increases the creepage distance and electrical clearance, improving resistance to pollution flashover and wet flashover in demanding indoor environments.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u9ad8\u673a\u68b0\u5f3a\u5ea6<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The integrated cast structure provides excellent resistance to impact and vibration.<\/li>\n\n\n\n<li>Capable of withstanding mechanical stress during switchgear transportation, installation, and operation.<\/li>\n\n\n\n<li>Resistant to cracking and deformation.<\/li>\n\n\n\n<li>The stable mounting structure is compatible with different switchgear dimensions and remains secure during long-term operation.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u5f3a\u5927\u7684\u73af\u5883\u9002\u5e94\u6027<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Resistant to ageing, high and low temperatures, and humidity.<\/li>\n\n\n\n<li>Suitable for stable operation over a wide temperature range from -40\u00b0C to +70\u00b0C.<\/li>\n\n\n\n<li>The epoxy resin material provides good chemical resistance against common indoor dust and mildly corrosive gases.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">High Operational Safety<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>When used with a compatible voltage presence indicator, the sensor supports real-time voltage monitoring and electrical interlocking.<\/li>\n\n\n\n<li>Helps prevent incorrect operations such as operating a disconnector under load or entering an energized compartment.<\/li>\n\n\n\n<li>The fully insulated structure contains no exposed live parts, reducing the risk of induced voltage and accidental electric shock.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Convenient Installation and Low Maintenance<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Standardized mounting dimensions are available in 95 \u00d7 130, 95 \u00d7 135, 95 \u00d7 140, 95 \u00d7 145, 95 \u00d7 150, and 95 \u00d7 170 mm configurations.<\/li>\n\n\n\n<li>Compatible with multiple switchgear mounting arrangements.<\/li>\n\n\n\n<li>Easy to install and replace.<\/li>\n\n\n\n<li>The product is designed for maintenance-free operation under normal conditions, helping reduce operating and maintenance costs.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u6280\u672f\u89c4\u683c<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Rated Parameters<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u53c2\u6570<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead><tbody><tr><td>\u989d\u5b9a\u7535\u538b (Un)<\/td><td>10\u5343\u4f0f<\/td><\/tr><tr><td>\u989d\u5b9a\u9891\u7387 (fn)<\/td><td>50 \u8d6b\u5179<\/td><\/tr><tr><td>\u6700\u5927\u5de5\u4f5c\u7535\u538b (Um)<\/td><td>12\u5343\u4f0f<\/td><\/tr><tr><td>\u989d\u5b9a\u7edd\u7f18\u6c34\u5e73<\/td><td>Power-frequency withstand voltage: 42 kV for 1 minute; lightning impulse withstand voltage: 75 kV peak<\/td><\/tr><tr><td>\u722c\u7535\u8ddd\u79bb<\/td><td>\u2265230 mm, meeting the insulation requirements of 10 kV systems<\/td><\/tr><tr><td>Applicable System<\/td><td>Indoor three-phase AC 10 kV high-voltage system<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u7ed3\u6784\u548c\u5c3a\u5bf8\u53c2\u6570<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6a21\u578b<\/th><th>\u5b89\u88c5\u5c3a\u5bf8<\/th><th>\u603b\u9ad8\u5ea6<\/th><th>Maximum Outside Diameter<\/th><th>Installation Type<\/th><\/tr><\/thead><tbody><tr><td>CG5-10Q\/95\u00d7130<\/td><td>95 \u00d7 130 mm<\/td><td>130 mm<\/td><td>110\u6beb\u7c73<\/td><td>Embedded or post-mounted<\/td><\/tr><tr><td>CG5-10Q\/95\u00d7135<\/td><td>95 \u00d7 135 mm<\/td><td>135 mm<\/td><td>110\u6beb\u7c73<\/td><td>Embedded or post-mounted<\/td><\/tr><tr><td>CG5-10Q\/95\u00d7140<\/td><td>95 \u00d7 140 mm<\/td><td>140 mm<\/td><td>110\u6beb\u7c73<\/td><td>Embedded or post-mounted<\/td><\/tr><tr><td>CG5-10Q\/95\u00d7145<\/td><td>95 \u00d7 145 mm<\/td><td>145 mm<\/td><td>110\u6beb\u7c73<\/td><td>Embedded or post-mounted<\/td><\/tr><tr><td>CG5-10Q\/95\u00d7150<\/td><td>95 \u00d7 150 mm<\/td><td>150 mm<\/td><td>110\u6beb\u7c73<\/td><td>Embedded or post-mounted<\/td><\/tr><tr><td>CG5-10Q\/95\u00d7170<\/td><td>95 \u00d7 170 mm<\/td><td>170 mm<\/td><td>110\u6beb\u7c73<\/td><td>Embedded or post-mounted<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Special dimensions can be customized according to project requirements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u73af\u5883\u53c2\u6570<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u53c2\u6570<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead><tbody><tr><td>\u73af\u5883\u6e29\u5ea6<\/td><td>-40\u00b0C \u81f3 +70\u00b0C<\/td><\/tr><tr><td>\u76f8\u5bf9\u6e7f\u5ea6<\/td><td>Daily average \u226495%; monthly average \u226490%, non-condensing<\/td><\/tr><tr><td>Installation Altitude<\/td><td>\u22641,000 m; high-altitude versions available<\/td><\/tr><tr><td>Seismic Resistance<\/td><td>Suitable for seismic intensity up to Level 8<\/td><\/tr><tr><td>\u9632\u62a4\u7b49\u7ea7<\/td><td>IP65 for the cast body<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Matching and Performance Parameters<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Compatible voltage presence indicators: DXN-T, DXN-Q, and other indoor high-voltage presence indicator series.<\/li>\n\n\n\n<li>Capacitance: 10\u201330 pF, customizable according to the matched indicator.<\/li>\n\n\n\n<li>Dielectric loss factor: \u22640.005 at power frequency.<\/li>\n\n\n\n<li>Partial discharge: \u226410 pC at 1.1 Um\/\u221a3.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u5e94\u7528<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Applicable Equipment<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Indoor 10 kV high-voltage switchgear, including KYN28, XGN, and HXGN series.<\/li>\n\n\n\n<li>Ring main units.<\/li>\n\n\n\n<li>Box-type substations.<\/li>\n\n\n\n<li>High-voltage distribution cabinets.<\/li>\n\n\n\n<li>Other indoor high-voltage power distribution equipment.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Applicable Locations<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Power plants and substations.<\/li>\n\n\n\n<li>Industrial and mining enterprises.<\/li>\n\n\n\n<li>Residential communities.<\/li>\n\n\n\n<li>Commercial complexes.<\/li>\n\n\n\n<li>Other 10 kV power distribution systems.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The product is suitable for indoor high-voltage electrical installations requiring voltage presence monitoring and electrical interlocking to prevent incorrect operation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Unsuitable Applications<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The standard product is not suitable for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Exposed outdoor installation.<\/li>\n\n\n\n<li>Strongly corrosive environments.<\/li>\n\n\n\n<li>Environments with electromagnetic interference exceeding the specified range.<\/li>\n\n\n\n<li>High-voltage systems rated above 12 kV.<\/li>\n\n\n\n<li>Indoor environments with severe condensation, water accumulation, or explosive dust without additional protection.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Customized versions are available for special operating conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u64cd\u4f5c\u6761\u4ef6<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u6b63\u5e38\u8fd0\u884c\u6761\u4ef6<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ambient temperature: -40\u00b0C to +70\u00b0C.<\/li>\n\n\n\n<li>Daily temperature variation: no more than 25\u00b0C.<\/li>\n\n\n\n<li>Installation altitude: no more than 1,000 m.<\/li>\n\n\n\n<li>Daily average relative humidity: no more than 95%.<\/li>\n\n\n\n<li>Monthly average relative humidity: no more than 90%.<\/li>\n\n\n\n<li>The installation environment should be free from condensation, severe dust, violent vibration, explosion hazards, corrosive gases, and heavy pollution.<\/li>\n\n\n\n<li>Indoor installation only.<\/li>\n\n\n\n<li>The sensor should be installed vertically, with an inclination angle of no more than 5\u00b0.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For installations above 1,000 m, insulation correction should be carried out according to GB\/T 11022, and a customized high-altitude version should be selected.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Special Operating Conditions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Customized products are required for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>High-altitude areas from 1,000 to 4,000 m, requiring an increased creepage distance and optimized insulation structure.<\/li>\n\n\n\n<li>High-temperature, high-humidity, or condensation-prone environments, requiring anti-condensation measures and specialized epoxy resin.<\/li>\n\n\n\n<li>Heavily polluted environments, requiring an increased creepage distance and pollution-resistant shed structure.<\/li>\n\n\n\n<li>Strong-vibration environments, requiring reinforced mounting and improved seismic resistance.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Installation and Operating Requirements<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u5b89\u88c5\u8981\u6c42<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Pre-installation inspection:<\/strong> Confirm that the sensor is free from cracks, damage, bubbles, and deformation. Verify that the model, dimensions, and mounting-hole spacing match the switchgear.<\/li>\n\n\n\n<li><strong>Mounting:<\/strong> Secure the sensor with bolts and ensure that it is firmly connected to the switchgear enclosure and high-voltage busbar.<\/li>\n\n\n\n<li><strong>Wiring:<\/strong> Connect the secondary terminal securely to the voltage presence indicator. Ensure that all insulation wrapping and terminal protection are complete.<\/li>\n\n\n\n<li><strong>Secondary circuit insulation resistance:<\/strong> \u2265100 M\u03a9.<\/li>\n\n\n\n<li><strong>Electrical clearance:<\/strong> After installation, confirm that the clearances and creepage distances between live parts, the switchgear enclosure, and grounded structures meet the requirements of the 10 kV system.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Operating Requirements<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The sensor must be used with a qualified high-voltage presence indicator and must not be operated independently.<\/li>\n\n\n\n<li>Installation, removal, or maintenance while the sensor is energized is strictly prohibited.<\/li>\n\n\n\n<li>Regularly inspect the sensor body and wiring for looseness, damage, contamination, or discharge marks.<\/li>\n\n\n\n<li>If cracking, discharge, insulation breakdown, or other abnormalities occur, immediately de-energize the equipment and replace the sensor.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u7ef4\u62a4\u4e0e\u4fdd\u517b<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Routine inspection:<\/strong> Inspect the sensor monthly for cracks, discharge marks, contamination, and loose wiring.<\/li>\n\n\n\n<li><strong>Periodic testing:<\/strong> Conduct insulation resistance and power-frequency withstand voltage tests every one to three years. Continue operation only after the test results are confirmed as acceptable.<\/li>\n\n\n\n<li><strong>Cleaning:<\/strong> Clean the sensor surface using a dry cloth. Do not use wet cloths or corrosive cleaning agents.<\/li>\n\n\n\n<li><strong>Storage:<\/strong> Store the product indoors in a dry, ventilated environment free from corrosive gases. Protect it from direct sunlight, compression, and impact.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u9002\u7528\u6807\u51c6<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GB\/T 1985, <em>High-Voltage Alternating-Current Disconnectors and Earthing Switches<\/em><\/li>\n\n\n\n<li>GB\/T 11022, <em>Common Specifications for High-Voltage Switchgear and Controlgear Standards<\/em><\/li>\n\n\n\n<li>DL\/T 538, <em>Technical Specifications for High-Voltage Presence Indicating Devices<\/em><\/li>\n\n\n\n<li>JB\/T 10686, <em>Sensors for High-Voltage Presence Indicating Devices<\/em><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u6ce8\u610f\u4e8b\u9879<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>This product is a high-voltage electrical component. Installation and maintenance must be carried out by qualified electrical personnel in strict accordance with electrical safety procedures.<\/li>\n\n\n\n<li>Unauthorized disassembly or modification is prohibited, as it may damage the insulation structure and cause a safety hazard.<\/li>\n\n\n\n<li>Avoid severe impact, dropping, or compression during transportation and handling to prevent cracking of the epoxy resin body.<\/li>\n\n\n\n<li>The recommended service life is generally 20 years. Replacement is recommended when the product exceeds its specified service life to maintain operational safety.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">\u6a21\u578b\u63cf\u8ff0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>CG5-10Q\/95\u00d7130<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>CG5:<\/strong> Indoor high-voltage presence indicator sensor series.<\/li>\n\n\n\n<li><strong>10Q:<\/strong> Rated voltage of 10 kV; Q indicates an indoor spherical or post-type structure.<\/li>\n\n\n\n<li><strong>95\u00d7130:<\/strong> Mounting dimensions in millimetres. Other available specifications include 95 \u00d7 135, 95 \u00d7 140, 95 \u00d7 145, 95 \u00d7 150, and 95 \u00d7 170 mm.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Product Overview The CG5-10Q Series Indoor High-Voltage Presence Indicating Device Sensor, hereinafter referred to as the \u201csensor,\u201d is a key [&hellip;]<\/p>\n","protected":false},"featured_media":772,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_category":[15],"class_list":["post-770","products","type-products","status-publish","has-post-thumbnail","hentry","product_category-casing-series"],"acf":{"products_imagines":[771,772],"short_describe":"<p><span style=\"color: #334155; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif; font-size: 16px; white-space: pre-wrap;\">The CG5-10Q Series Indoor High-Voltage Presence Indicator Sensor, hereinafter referred to as the &ldquo;sensor,&rdquo; is a key supporting component designed for indoor high-voltage electrical systems rated at 10 kV and below.<\/span><\/p>","pdf_file":"","related_products":{"products":""},"technical_parameter":"","outline_and_installation_dimension":""},"_links":{"self":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/products\/770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/types\/products"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media\/772"},{"embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media\/771"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media\/772"}],"wp:attachment":[{"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/media?parent=770"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/yieou.com\/zh\/wp-json\/wp\/v2\/product_category?post=770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}